Post by etienneneu on Trend x-axis description incorrect display
CODESYS Forge
talk
(Post)
Hello everyone, maybe someone can help me with the following problem. I wanted to insert a trend element in my visualization. The problem is that I have set fixed fonts with a scaling of 1.5 for the individual languages via the visualization manager. This setting means that I have this scaling in every element, which has been quite comfortable so far because I didn't have to set the individual properties in the text fields. But in the trend element, even if I select other font sizes or fonts in the element itself, this font is also overwritten and I get a label on the x-axis that is no longer displayed correctly. Is there a way to prevent the overwriting of the font properties in this element or similar behavior? I mean, I could change the font size of each element manually, but the Visu app is a bit larger and it would be easier to have another option. Best regards Etienne
Last updated: 2024-11-28
Post by manuknecht on Persistence Manager does not save alphabetically first value
CODESYS Forge
talk
(Post)
I have several libraries which contain values that should be saved on a PLC. As apparently no Persistent Variable List is available within Libraries, I use the Persistence Manager to create a Persistence Channel in the Project which imports the library. I then specify the persistence channel in the library using the {attribute 'ac_persist':='PersistenceChannel_CT'} specifier. This generally works very well and gives me exactly the properties I require. However, it came to my attention that the (alphabetially) first value from the library is not saved in the created ASCII file. When checking the content of the Persistence Channel, it shows all the variables as defined in the library. But the created file does not contain the first value and it is not restored after restart or reset. (see attached picture) I disabled Periodic Saving and set xSaveOnChange to TRUE and so the file usually updates immediately after changing one of the values. When changing the first value, it does not update which is consistent with this value not being saved. I also created a sample project and library from scratch which shows the same issue both using a Raspberry Pi and using a Linux machine. Does someone know what the reason for this could be or did someone make similar experiences? Looking forward to hearing your suggestions. Thanks in advance and best wishes Manuel
Last updated: 2023-10-17
Post by toby on Ethernet/IP communication with Omron NX1P2
CODESYS Forge
talk
(Post)
Hey guys, I'm very much a noob with networking, it's my achillies heel, and this is my first networking project using Ethernet/IP. Any help offered is GREATLY appreciated. I'm trying to network a Codesys Project with an Omron NX1P2 PLC. I'm using EIP due to hardware restrains. I've added the fieldbus, EIP scanner (as the master), and made a Network Variable List. On the Sysmac Studio end, I've made the variables and set them to network inputs/outputs, registered them in EIP settings, but when I try to set the target device (the Codesys project), I suspect I need to import an EDS file for the EIP mapping. Back in the Codesys project, I'm not sure how to: - Make an EDS file to share with Sysmac Studio - How to link the target device (Omron PLC) to the EIP fieldbus - How to map the inputs from the Omron PLC. Im sorry for my very open request for help, i'm kind of lost looking through the various forums/video/tutorials as many of them dont match what im trying to do. Any help, or sample programs would be so so greatly appreciated. If you need any further clarifications, please feel free to ask. Thanks in advance, Toby
Last updated: 2024-01-24
Post by svenkaro on Codesyscontrol.service stoppt nach 30s
CODESYS Forge
talk
(Post)
Wie Du schon vermutet hast, es meint, die Hardware/Firmware sei nicht kompatibel ... ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) Architecture: aarch64 Byte Order: Little Endian CPU(s): 4 On-line CPU(s) list: 0-3 Vendor ID: ARM Model name: Cortex-A72 Model: 3 Thread(s) per core: 1 Core(s) per cluster: 4 Socket(s): - Cluster(s): 1 Stepping: r0p3 CPU(s) scaling MHz: 40% CPU max MHz: 1500.0000 CPU min MHz: 600.0000 BogoMIPS: 108.00 Flags: fp asimd evtstrm crc32 cpuid Caches (sum of all): L1d: 128 KiB (4 instances) L1i: 192 KiB (4 instances) L2: 1 MiB (1 instance) Vulnerabilities: Gather data sampling: Not affected Itlb multihit: Not affected L1tf: Not affected Mds: Not affected Meltdown: Not affected Mmio stale data: Not affected Retbleed: Not affected Spec rstack overflow: Not affected Spec store bypass: Vulnerable Spectre v1: Mitigation; __user pointer sanitization Spectre v2: Vulnerable Srbds: Not affected Tsx async abort: Not affected Allerdings habe ich schon reichlich Firmware versionen getestet.
Last updated: 2024-06-21
Post by abauza on Image Pool using in other libraries
CODESYS Forge
talk
(Post)
Hi im Albert, im developing libraries for my PLCs and i have some issues on visualization part. First of all I have done a library that have a image pool with a list of 4 gifs "ImagePoolErrors" (i've tested in other projects and it works) but the problem comes when i create another library that in the visualization part contains images from my image pool library, when i simulate a program that includes a instance of my second library object the visualization images dont show, any of them, i've checked all the references and tried some options of the image properties but without any difference. Here is the screenshots of the first library (that contains Image Pool) and the second library (that includes images of the image pool first library) and the visualization simulation (with the missing image gif issue). Any idea of what i forgotten in the process? If you need any detail of the library or of the project or you need the library file, ask me, thank on advance
Last updated: 2024-08-19
Post by kbazzett on "Sequent Microsystems" industrial automation hat raspberry pi
CODESYS Forge
talk
(Post)
Here is a complete list of the Sequent Microsystems Pi hats that work in Codesys. https://github.com/SequentMicrosystems/SM_CODESYS/tree/main/ "For easy install download the .package file and open it on your computer, Codesys installer will know what to do with it." <- This. The Multi I/O Hat fit my needs because of the Analog I/O 4-20ma and RTD. I used a Raspberry Pi 5 and 64b install. The example project is also worth the download. With the sample project open, right click on the Raspberry Pi device and update to whatever you are using (SL, MC, 64b). Enable I2C on the PI. You can jumper the hats Analog Outputs to Inputs and see it function on the Web Visualization. Very Cool! I spent quite a bit of time trying to find this solution so hopefully this update helps others. Here is the video link on how to setup a Raspberry PI as a Codesys PLC https://youtu.be/RPoPscbo3Kc?si=Th4-n-mQ6g5fdHj8
Last updated: 2024-12-05
Post by dom4u on Using PEAK CAN PCIe card (IPEH-004040) with Codesys Control RTE V3
CODESYS Forge
talk
(Post)
Some findings on this issue: PEAK CAN Driver is the same as in every PCI card from PEAK. I updated the inf file. Here are my steps: 1. Include right VendorID into the *.inf file 2. Disable Windows driver check (Disable WHQL check). This you need because 3S driver is not certified. You will find steps via google or ask chatgpt :) 3. Select: Select driver from a list and navigate to the folder. Say yes to install an uncertified driver. 4. Driver installed and device without errors I did the same with CAN Card from ESD, but here you dont need to include the vendor ID. In ANY CASE it was not successful. The RTIOwdmgeneric is not available in Codesys or anyhow accassable :( I wonder that it fails in two cases, two suppliers, two driver in the same way. How can RTIOwdmgeneric implemented into the project?
Last updated: 7 days ago
Post by ryandmg on Web Client (HMI) Disconnects from Webvisu (Weidmuller u-OS)
CODESYS Forge
talk
(Post)
Hey Everyone, I'm having a bit of a struggle finding settings that will reliably maintain a connection between the webvisu and a touchscreen client. Every so often the HMI disconnects and will perpetually display the red spinning arrow with the "Error Happened, Will resume automatically" text. Power cycling the HMI to force a reconnect will re-establish comms. It seems to happen during periods of inactivity if that's a clue. From what I've gathered so far this seems to have something to do with the webvisu update rate, buffer size as well as the visu task scan rate. We first tried the default settings as follows: Webvisu Update Rate: 200 ms Webvisu Buffer Size: 50,000 Visu Task Scan Rate: 100 ms Priority 31 Other Tasks for Reference: Main Task Scan Rate: 100 ms Priority 1 Alarm Manager Scan Rate: 50 ms Priority 31 Ethercat Task: 4 ms Priority 1 This would disconnect some what regularly. We then made the following changes to try and stabilize: Webvisu Update Rate: 150 ms Webvisu Buffer Size: 75,000 Visu Task Scan Rate: 75 ms Kept other tasks the same. This seems to disconnect even more frequently. Also for reference the network is very small and only consists of the PLC, a small switch and the HMI. We're also not controlling frames from outside the visu program itself. The frame changes are all done natively. Any suggestions to get this to stop disconnecting? Oh and whatever the issue is the log does not record it. Figured I would ask here before opening a ticket. Thanks in advance for your help!
Last updated: 2023-09-06
Post by mondinmr on Why SysPipeWindows is not implemented in RTE?
CODESYS Forge
talk
(Post)
This library would be very useful for IPC communications. Using a UDP socket on localhost is unpredictable, as with slightly loaded machines it does not even guarantee packet delivery locally. Using TCP creates a lot of overhead. Message named pipes would be an excellent solution for Windows RTE. On Linux, since the release of the extension package, there is no issue, as it is sufficient to develop a component. However, although now 90% of our clients understand that Linux runtimes are better in every way compared to Windows RTE, especially from the security aspect (Not in kernel space) and the issues with Windows updates, 10% stubbornly insist (sometimes for trivial commercial reasons) on using Windows. Managing IPC with circular buffers in shared memory is quite ugly, or rather really ugly and unaesthetic. In the manuals, I saw the SysPipeWindows libraries, so I decided to test them, but unfortunately, I noticed that they are not implemented for RTE devices. Technically, I could try to open them as regular files, but SysFileOpen returns 16#27 or 16#39 depending on how I set the name (direction of the slashes). Here is the code to create shared memory and named pipes. Shared memory work great, named pipes no! #ifdef Q_OS_WIN32 SECURITY_ATTRIBUTES sa; SECURITY_DESCRIPTOR sd; InitializeSecurityDescriptor(&sd, SECURITY_DESCRIPTOR_REVISION); SetSecurityDescriptorDacl(&sd, TRUE, NULL, FALSE); sa.nLength = sizeof(SECURITY_ATTRIBUTES); sa.lpSecurityDescriptor = &sd; sa.bInheritHandle = FALSE; const wchar_t* name = L"Global\\ShmTest"; HANDLE hMapFile = CreateFileMapping( INVALID_HANDLE_VALUE, NULL, PAGE_READWRITE, 0, sizeof(SharedData), name); if (hMapFile == NULL) { qCritical("Error creating shared memory"); return 1; } data = static_cast<SharedData*>(MapViewOfFile(hMapFile, FILE_MAP_ALL_ACCESS, 0, 0, sizeof(SharedData))); if (data == NULL) { qCritical("Error mapping shared memory"); return 1; } HANDLE hPipe = CreateNamedPipe( TEXT("\\\\.\\pipe\\MyPipe"), PIPE_ACCESS_DUPLEX, PIPE_TYPE_MESSAGE | PIPE_READMODE_MESSAGE | PIPE_WAIT, PIPE_UNLIMITED_INSTANCES, 1024 * 1024, 1024 * 1024, NMPWAIT_USE_DEFAULT_WAIT, &sa); if (hPipe == INVALID_HANDLE_VALUE) { qCritical("Error creating named pipe"); return -1; } if (!ConnectNamedPipe(hPipe, NULL)) { qCritical("Error connecting to named pipe"); return -1; } checkPipe(hPipe); #endif
Last updated: 2024-02-02
Post by umdee on Error when monitoring LAD programs
CODESYS Forge
talk
(Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Yes, this is the error the sometimes show up. What make me crazy is the fact that it happens randomly and not each times. I know very well where the problem is, in wich one program row it's located. For each actions of the state machine I have all events recorded with log on text file. it is not problematic for me to find the application point of the fault, but I need to understand why occasionally and for no apparent reason, switching the state machine and thus changing the motion FB, sends the axis into failure (but only occasionally). For example, one case that is often problematic is the execution of the Axis Halt instruction. When, after a MoveAbosulte instruction this returns the event as 'done' and indeed the axis is in standstill, the state machine first sets the move instruction to FALSE, and the next cycle sets the Halt request to TRUE. Some of the time everything works out fine. Occasionally, however, in this exchange, the axis goes into fault, also losing the OPERATIONAL state. Meanwhile, I would like to understand why the motion FB instances must still be called even after the Execute is set to FALSE, especially in view of the fact that the next instruction is programmed to abort the previous one, with BufferMode set to 'Aborting'. All these unnecessary FB calls are an unnecessary overhead on the CPU anyway. Is there any precise rule about when to cease calling the various instances? (It should precisely be the 'done' status that says this one has finished its work).
Last updated: 2024-07-18
Post by full0pullpolen on Device User Logon
CODESYS Forge
talk
(Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24
Post by full0pullpolen on Device User Logon
CODESYS Forge
talk
(Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24
Post by full0pullpolen on Device User Logon
CODESYS Forge
talk
(Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24
Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5)
CODESYS Forge
talk
(Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06
Post by ppix on Establishing TLS Connection with MQTT Broker using MQTT Client SL Package
CODESYS Forge
talk
(Post)
I’m currently working on establishing a TLS connection with an MQTT broker using the MQTT Client SL package in CODESYS. While I’ve successfully established communication with the broker without TLS, I'm encountering issues when trying to enable TLS. In the 'MQTT Explorer' application, I can easily upload the server certificate (.crt), client certificate (.crt), and client key (.key). However, in CODESYS, I can’t find a way to upload my client key (.key file). Here's a summary of my current setup: Certificates: I have uploaded both the client and server certificates to the certificate store under the 'Trusted Certificates' folder in the security screen. TLS Context Initialization: Despite setting the _sCommonName as the name of my client certificate, a new self-signed certificate is created and placed within the device’s certificates. I then need to manually move this certificate to the trusted certificates folder. This results in three certificates in my trusted certs folder: client cert, server cert, and the newly created cert. _ciDefaultCertInfo : MQTT.NBS.CERT_INFO := (psInfo := ADR(_sCommonName), udiSize := TO_UDINT(LEN(_sCommonName))); // CN of the certificate (common name) _sCipherList : MQTT.NBS.CIPHER_LIST := STRUCT(psList := ADR('HIGH'), udiSize := 4); // Cipher string see https://www.openssl.org/docs/man1.1.1/man1/ciphers.html _tlsContext : MQTT.NBS.TLSContext := ( sUseCaseName := _sCommonName, // A certificate is stored in the certificate store with the use case name. You can choose any name. Here we use the common name. ePurpose := MQTT.NBS.PURPOSE.CLIENT_SIDE, // For client certificates set this to NBS.PURPOSE.CLIENT_SIDE sTLSVersion := '1.3', // The TLS version sCipherList := _sCipherList, // Set the cipher list sHostname := sHostname, // The hostname of the broker udiVerificationMode := 2, // 2 => Active Peer verification ciCertInfo := _ciDefaultCertInfo, // Set the cert info itfCertVerifer := 0); // 0 => No Verifier mqttClient : MQTT.MQTTClient := (xUseTLS:=TRUE, itfTLSContext := _tlsContext, itfAsyncProperty := _asyncProperty); Additional Details: In the client FB, I’ve set uiPort:= 8883, xUseTLS:= TRUE, and configured itfTLSContext as mentioned above. The certificates are encrypted with SHA256RSA. sHostname is the IP address of my broker. I’ve attached a copy of the client FB, which shows straight lines where variables are assigned and boxes where they are not. I am currently trying this on the only 2 compatible versions of COSDESYS with my controller (V3.5.15.20 and V3.5.18.40) My Question: How do I correctly set up this mTLS connection? What might I be missing? Any guidance or suggestions would be greatly appreciated, especially considering I’ve already successfully established a non-TLS connection with the same broker. Thank you in advance for your help!
Last updated: 2024-06-19
Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port
CODESYS Forge
talk
(Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01
Post by hwillems on Ranges, Lambdas, on Fixed arrays of structs
CODESYS Forge
talk
(Post)
I do datastructures and algorithms in Codesys. For example a Struct of Person with thing's like IdNumber, Name, Age etc. as example. Now i do all kind of calculations, filters. So i have this pretty big Fixed Array with Structs. On this struct i want to do simple stuff you can do easily in C++/Python/Rust etc. For example i want to do this: AvererageAge := Average(Peoples.Age); Then it will return the average of all members ages. Or Sort struct on age etc. Or sort on alphabetical Name. Or use Lambda functions to filter/mutate out things like, filter out everybody above 18 years old. Or remove people who it's name start with "A". Currently i have to write my own custom function for example sorting on Age. And make a super specific function based on that particulare datastructure. Here an Example: (*Before calling this FIlter method, set the mNodeFilterSwitch to the desired filter.*) CASE mNodeFilterSelect OF (********************************[ Status Filters ]***********************************) NodeID: FOR x := ACS_OUT_BEGIN TO ACS_OUT_END BY 1 DO FOR y := ACS_IN_BEGIN TO ACS_IN_END BY 1 DO IF marrNode[y].Status.oiNodeID > marrNode[y + 1].Status.oiNodeID THEN mNodeTemp := marrNode[y + 1]; marrNode[y + 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Started: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarted > marrNode[y - 1].Status.oxStarted THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; Starting: FOR x := DES_OUT_BEGIN TO DES_OUT_END BY -1 DO FOR y := DES_IN_BEGIN TO DES_IN_END BY -1 DO IF marrNode[y].Status.oxStarting > marrNode[y - 1].Status.oxStarting THEN mNodeTemp := marrNode[y - 1]; marrNode[y - 1] := marrNode[y]; marrNode[y] := mNodeTemp; END_IF; END_FOR; END_FOR; END_CASE; I have like 30+ of these in the enum. Not really DRY code right? These are custom made bubble sort filters in a function. You pass in the Datastructure, and say what function you want. (This is an enum collection of sorting functions) And then the Array with Nodes of Structs gets ordered. Why can't we have Iterators and Lambda's and build in standard functions like regular languages? Also i use bubble sort because it's the easiest to implement because i can't get this to code DRY. Problem with ST (Even the new one with classes) that it's very limited for programming datastructures and algorithms. Yes you still not want dynamic memory and you need to choose the correct algorithm so you know the most extreme edge cases regarding the time it takes to execute the algorithms.(Real-time execution) How are other people dealing with this? Here for example saw some software using an adjusted ST language and having FOR EACH possibility: https://www.fernhillsoftware.com/help/iec-61131/structured-text/st-for-each.html You can then build your own custom Iterator functions. I wish the IEC 61131-3 standard would be more expressive and having more standard modern features, but still keep close to the fact of no dynamics memory and real-time systems.
Last updated: 2023-08-31
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Hello everyone, I have a very simple program for the process, but it's driving me crazy and I can't see the problems I'm left with: Short topological description: Dual Core Berghof controller with softmotion runtime version 3.5.19.30; Two axes with servodrive on canopen bus, clocked distributed from master; Ethercat I/O node; 2 ms ethercat task, 2 ms canopen bus cycle time; I/O objects of the canopen master and canopen drives connected to the ethercat task cycle; Problem 1: Two separate programs each manage their own axis and drive, with separate state machines. A first axis moves primarily in velocity, except having to position itself absolutely at a predetermined point at the end of the job; the second axis, on the other hand, is a paper unwinder that changes, for each job cycle, from actions in absolute, relative, and cam displacement with the master axis. Well, the state machine of both axes was written in such a way as to call running the useful FB and change it on state change in this way: CASE i_stateMachine OF 0: o_Power(Enable := TRUE, bRegulatorOn := FALSE, bDriveStart := FALSE, Axis := o_PaperUnwinderAxis); o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_MoveRel(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_CamSelect(Execute := FALSE, Master := o_MachineAxis, Slave := o_PaperUnwinderAxis, CamTable := cam_PaperUnwinder); o_CamIn(Execute := FALSE, Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Execute := FALSE, Slave := o_PaperUnwinderAxis); o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis); IF ... THEN i_StateMachine := 10; END_IF; 10: o_Power( Enable := TRUE, bRegulatorOn := TRUE, bDriveStart := TRUE, Axis := o_PaperUnwinderAxis ); IF o_Power.Status THEN i_StateMachine := 20; END_IF; 20: (* Avanzamento carta *) o_MoveAbs( Execute := TRUE, Position := o_Somewhere, Velocity := 25.0, Acceleration := 3666.7, Deceleration := 3666.7, Jerk := 48000.0, Direction := MC_DIRECTION.positive, Axis := o_PaperUnwinderAxis ); IF o_MoveAbs.Done THEN o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); i_StateMachine := 30; END_IF 30: d_HomingPosition := ...; o_SetPosition( Execute := TRUE, Position := d_HomingPosition, Mode := FALSE, Axis := o_PaperUnwinderAxis ); (* ... *) IF o_SetPosition.Done = TRUE THEN o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis ); o_LogServer.Append(sMessage := '...', lscClass := LOGSERVER_CLASS.ALWAYS, sdt := o_CommonsMgrData.systime.sdtLocal); i_StateMachine := 40; END_IF; 50: ... The code above is a sketchy example of what I wanted to write. But it gives me a spot problem: in some, the state change results in a drive error, which is unrecoverable except with a reinitialization via SM3_ReinitDrive(). Things are improved a little if in the program I always run the call of all softmotion blocks in this way: o_Power(Axis := o_PaperUnwinderAxis); o_Jog(Axis := o_PaperUnwinderAxis); o_Halt(Axis := o_PaperUnwinderAxis); o_MoveAbs(Axis := o_PaperUnwinderAxis); o_MoveRel(Axis := o_PaperUnwinderAxis); o_CamIn(Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Slave := o_PaperUnwinderAxis); If I don't execute all the calls of all the motion FBs used, when exchanging machine state often (but not always), the axis goes into error with event id THE_FB_WASNT_CALL... Done a little diagnostics it seems that the FBs return the bDone, before they are completely terminated. I tried doing the machine state exchange not with the bDone bit of the FBs, but with the 'standstill' state of the axis. It didn't seem to change anything. Problem 2: During the use SM3_ReinitDrive() I get the erro in the log: "NetID 0: SDO read error for object 16#607C..." Assuming that the device involved it's one of the two servodrive, (no others device are present in the network), I don't found any object 0x607C in the 'possible object list in/out' of the two drive, and I don't understand where this object can be listed. So any ideas and suggestions regarding these two issues will be very, very welcome. If you need the source project, I am willing to send it.
Last updated: 2024-07-17
Post by r-niedermayer on OPC UA subscriber not operational
CODESYS Forge
talk
(Post)
Hi. As far as projects in "old version"s are concerned, these can be upgraded to newer versions at any time. To do this, the device must be updated accordingly and the copilers and library versions must be adapted. You can find instructions on how to proceed in the online help/FAQ: https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_changing_compiler_version.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_update_device.html See also 4.3.22.4 "How to open an Example Project" within the following pdf for more details on the single steps: https://forge.codesys.com/lib/counit/tickets/_discuss/thread/3e991befbc/ca97/attachment/Public%20FAQ-v13-20240610_075228.pdf Regaring your OPCUA connection state always showing just "DISABLED", without knowing both sides of the assembly in detail, one can only approach the problem theoretically. We can give a chekclist on how to proceed: Fist, please recheck the communication settings in the OPC UA connection function block to ensure that the server URL, endpoint URL, and other settings are correct and match the configuration of the OPC UA server. Verify that the OPC UA server is running and accessible. -You can try to connect to the OPC UA server using a separate client, such as UAExpert, to ensure that the issue is not related to the OPC UA server itself. Test the security settings in the OPC UA connection function block to ensure that the correct security policy and certificate are selected. If you are using a dynamic connection to the OPC UA server, probe that the connection settings are correctly configured and that the OPC UA client is able to establish a connection to the OPC UA server. Also, please loock into the log files for any errors related to the OPC UA connection function block, these should be listet there. The log files may also provide additional information about the issue and help you to further troubleshoot the problem. FYI - Please see https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_obj_data_source_communication_opc_ua_server.html: Her you can finde the Communication settings via OPC UA Server -> layout Browse Live Server: The client connects to the server and detects the existing variables and types. From Information Model The client reads the data structure (layout) of the OPC UA Server from the information model set here and as a result receives the information about available variables and types. A connection to the server is not required. The list contains the information models installed in the OPC UA Information Model Repository. "Read Connection" Settings from IEC Variable (option set): - The connection settings used by the device are not read here from the dialog, but at runtime from the IEC variable specified here. - For this possibility, please see the Using a Dynamic Connection to an OPC UA Server (https://content.helpme-codesys.com/en/CODESYS%20Communication/_comm_use_dynamic_opc_ua_server_comm_settings.html) The settings for the communication of a Client-data source to an OPC UA Server can also be dynamically configured from the IEC code and can also be changed at runtime. For such a purpose, a structure is available in the DatasourceOpcUAServer library (For a description of the OPC UA Server, there is one included in the standard installation of CODESYS, https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_encrypt_communication_data_sources_opc_ua_client.html)
Last updated: 2024-11-04
Post by kamalsingh on Temu Coupon "$100 Off" ➥ ACU577459,, acq615756 For All Users (Up to 30% Off)
CODESYS Forge
talk
(Post)
USA Temu Coupon Code $100 Off ➥ [acu577459 & acq615756], TEMU Coupon Code "[acu577459 & acq615756]" | $100 Off & 50% Coupon, TEMU Coupon Code "[acu577459 & acq615756]" ,is an all in one opportunity, which also offers $100 Off & 50% Coupon! The TEMU Coupon Code "[acu577459 & acq615756]" & acq523557offers an impressive $100 Coupon and a 50% Coupon on purchases for both new and existing customers. This special offer is a fantastic opportunity to save significantly on your TEMU shopping experience. By using the Coupon Code "[acu577459 & acq615756]", you can unlock the $100 Coupon bundle, which provides $120 worth of savings. This means that you can enjoy a $100 Coupon on your order, as well as access to exclusive deals and additional savings opportunities. ⇦ Exclusive Temu Coupon Codes ,,,[acu577459 & acq615756],,,,, ➤ Offers → Coupons, Student Deals & More ╰┈➤ Best Temu Coupon Codes➤ "[acu577459 & acq615756]" ⇨ "acq523557" ➥ Up to 50% Off USA Temu Coupon "$100 Off" ➥ ACU577459,, acq615756 For All Users (Up to 30% Off) To redeem the TEMU $100 Coupon Code, simply follow these steps: Sign up for a TEMU account on their website or mobile app. Add items worth $100 or more to your shopping cart. During checkout, enter the Coupon Code "[acu577459 & acq615756]" in the designated field. The $100 Coupon will be automatically applied, and you can also enjoy an additional 50% off on your purchase. This Coupon Code is valid for both new and existing TEMU customers, making it a great opportunity for everyone to save on their shopping. The $100 Coupon bundle can be combined with other available Coupons, such as the 30% off code for fashion, home, and beauty categories, allowing you to maximize your savings. ➥ Temu Coupon Code $100 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 40 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 50 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 70 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 90 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 30 Off {[acu577459 & acq615756]} USA ➥ Temu Coupon Code First Order {[acu577459 & acq615756]} USA ➥ Temu Coupon Code Existing User {[acu577459 & acq615756]} USA ➥ Temu Coupon Code 90 Off {[acu577459 & acq615756]} or {[acu577459 & acq615756]} USA ➥ Temu Coupon Code |"$100 Off"| [[acu577459 & acq615756]] For New and Existing Customers USA ➥ Temu Coupon Code |"$100 Off"| [[acu577459 & acq615756]] First-time users USA Temu Coupon Code $100 Off [[acu577459 & acq615756]] For New Users 2024 USA Temu has rapidly gained popularity as a go-to shopping destination, offering a vast array of trending products at unbeatable prices. To welcome new users, Temu is excited to offer the exclusive Temu Coupon code $100 Off [[acu577459 & acq615756]]& acq523557]. Alongside this, existing customers can enjoy significant savings with the [acu577459 & acq615756] Coupon code. Why You Should Embrace Temu Coupon Codes USA Temu has revolutionized online shopping by providing an extensive range of products, from fashion and electronics to home goods and accessories. Coupled with fast delivery and free shipping to numerous countries, Temu has become a preferred choice for budget-conscious shoppers. Now, imagine enjoying these benefits with an additional $100 Off your purchase! That's where our Temu Coupon codes come in. Unveiling Top Temu Coupon Codes for October 2024 USA To maximize your savings, consider these exceptional Temu Coupon codes: [acu577459 & acq615756]: $100 Off for new users - A fantastic welcome offer. [acu577459 & acq615756]: $100 Off for existing customers - A reward for loyalty. [acu577459 & acq615756]: $100 extra off - Boost your savings significantly. [acu577459 & acq615756]: Free gift for new users - A delightful surprise. [acu577459 & acq615756]: $100 Coupon bundle - A comprehensive savings package. Navigating the Path to Temu Savings USA Redeeming your Temu Coupon code is a straightforward process: Create a Temu account or log in to your existing one. Explore Temu's vast collection and add your desired items to your cart. Proceed to checkout and apply your Coupon code at the designated box. Witness the magic unfold as your Coupon is instantly applied to your order total. Unlock Extraordinary Savings with Temu Coupon Code $100 Off [[acu577459 & acq615756]] The Temu Coupon code $100 Off [[acu577459 & acq615756]] is a fantastic opportunity for new users to experience the Temu shopping thrill with significant savings. Imagine purchasing your favourite items at a Couponed price. This Coupon empowers you to enjoy a wide range of products without breaking the bank. Unleash the Power of Temu Coupon Codes USA Flat $100 Coupon: Enjoy a substantial reduction on your entire order. USA $100 Coupon for new users: A generous welcome offer for first-time shoppers. USA $100 Off for existing customers: A reward for your loyalty to Temu. USA $100 Coupon for new customers: A fantastic incentive to try Temu. USA Temu $100 Off for old users: A token of appreciation for your continued support.USA Elevate Your Temu Shopping Experience To optimize your savings journey on Temu, consider these expert tips: Leverage free shipping: Enjoy complimentary delivery on your orders. USA Explore diverse product categories: Uncover hidden gems and unexpected finds. USA Stay alert for daily deals and flash sales: Seize limited-time opportunities. USA Combine Coupons with other Coupons: Maximize your savings potential. USA Share your shopping experience: Leave reviews to help others and potentially earn rewards. USA Utilize social media: Follow Temu on platforms like Instagram and Facebook for exclusive deals and Coupontions. USA Join Temu's email list: Stay informed about the latest offers and product launches. USA Essential Temu Coupon Codes for Unmatched Savings To further enhance your shopping adventure, explore these indispensable Temu Coupon codes: [acu577459 & acq615756]: Temu Coupon $100 Off for new users USA [acu577459 & acq615756]: Temu Coupon code $100 Off for existing customers USA [acu577459 & acq615756]: Temu Coupon codes 100% USA [acu577459 & acq615756]: Temu Coupon $100 Off code USA [acu577459 & acq615756]: Temu Coupon $100 Off first-time user USA Temu Coupon Codes for August 2024: The Key to Massive Coupons This month, Temu offers several enticing Coupon codes tailored to both new and existing users, ensuring everyone can save. Here’s a quick look at the top Temu Coupon codes you can take advantage of this August: [[acu577459 & acq615756]]: Temu Coupon code $100 Off for new users [[acu577459 & acq615756]]: Temu Coupon code 40% off for new customers [[acu577459 & acq615756]]: Temu Coupon code 40% extra off [[acu577459 & acq615756]]: Temu Coupon code for a free gift for new users [[acu577459 & acq615756]]: Temu $100 Coupon bundle for existing and new users These Temu Coupon codes offer a variety of benefits, from substantial Coupons to free gifts and bundled savings. Whether you’re shopping for fashion, electronics, home goods, or more, these codes will ensure you get the best deal possible. Whether you're a seasoned Temu shopper or a new customer, these Coupon codes offer an incredible opportunity to save on your purchases. Remember, the Temu Coupon code $100 Off [[acu577459 & acq615756]] is a limited-time offer. Don't miss out on this fantastic chance to enjoy significant savings! Embark on your Temu shopping spree today and experience the thrill of unbeatable prices. Temu Coupon Code-{[acu577459 & acq615756]} USA Temu Coupon Code: $100 Off{[acu577459 & acq615756]} USA Temu Coupon Code: Free Shipping{[acu577459 & acq615756]} USA Temu $100 Off Code{[acu577459 & acq615756]} USA Temu 50% Coupon Coupon{[acu577459 & acq615756]} USA Temu $120 Coupon Bundle Code{[acu577459 & acq615756]}{[acu577459 & acq615756]} USA Temu Student Coupon Coupon Code{[acu577459 & acq615756]} USA temu existing user Coupon code USA Using Temu's Coupon code [{[acu577459 & acq615756]}] will get you $100 Off, access to exclusive deals, and benefits for additional savings. Save 40% off with Temu Coupon codes. New and existing customer offers. USA temu Coupon code May 2024- {[acu577459 & acq615756]} USA temu new customer offer{[acu577459 & acq615756]} USA temu Coupon code 2024{[acu577459 & acq615756]} USA 100 off Coupon code temu{[acu577459 & acq615756]} USA temu 100% off any order{[acu577459 & acq615756]} USA 100 dollar off temu code{[acu577459 & acq615756]} USA What is Temu $100 Coupon Bundle? USA New Temu $100 Coupon bundle includes $120 worth of Temu Coupon codes. The Temu $100 Coupon code "{[acu577459 & acq615756]}" can be used by new and existing Temu users to get a Coupon on their purchases. Enjoy $100 Off at Temu with Coupon Code [[acu577459 & acq615756]] – Exclusive for October and October 2024! Looking for incredible savings on top-quality products at Temu? Whether you're new to Temu or a seasoned shopper, our special Coupon code [[acu577459 & acq615756]] offers you an exclusive chance to save $100 on your purchases throughout August and October 2024. Here's everything you need to know to take full advantage of this fantastic offer. For New Customers: 1. Sign Up and Save Big: • Download the Temu App: Start by downloading the Temu app from your smartphone's app store or visit the Temu website using your computer. Temu's user-friendly interface ensures a smooth shopping experience. • Create an Account: Register for a new account by providing your basic details. This process is quick and straightforward, and it unlocks your access to a $100 Coupon. • Browse and Add to Cart: Explore Temu's extensive range of products, from stylish fashion items to cutting-edge electronics and home essentials. Add items totaling $100 or more to your cart. This ensures that you meet the minimum purchase requirement to use the Coupon code. 2. Apply Your Coupon Code: • Proceed to Checkout: Once you've filled your cart, go to the checkout page. Here, you'll see a field labeled "Coupon Code" or "Coupon Code." • Enter Code [[acu577459 & acq615756]]: Input the Coupon code [[acu577459 & acq615756]] into the designated field and click "Apply." The $100 Coupon will be automatically applied to your total. • Review and Complete Purchase: Verify that the Coupon has been applied to your order. Complete the payment process and enjoy your shopping spree with a $100 Coupon! Tip for New Customers: This exclusive offer is valid only during August and October 2024. Make sure to use the code [[acu577459 & acq615756]] within this period to maximize your savings. For Existing Customers: 1. Shop and Save with Ease: • Log Into Your Account: If you're a returning Temu shopper, simply log into your existing account on the Temu app or website. • Explore and Add Items: Browse through the extensive product catalog. From the latest gadgets to home decor, add items totaling $100 or more to your cart. • Prepare for Checkout: Proceed to the checkout page where you'll be able to apply your Coupon. 2. Redeem Your Coupon Code: • Enter Coupon Code [[acu577459 & acq615756]]: In the "Coupon Code" field at checkout, enter [[acu577459 & acq615756]] and click "Apply." The $100 Coupon will be applied to your order total. • Check and Complete Purchase: Confirm that the Coupon has been applied correctly to your order. Finalize the payment details to complete your purchase. Tip for Existing Customers: This offer can be combined with other Coupon available during August and October, so keep an eye out for additional savings opportunities!
Last updated: 2024-10-26
Post by honorzen543 on Temu Coupon Code 30% Off [acu729640] For Existing Customers
CODESYS Forge
talk
(Post)
We’re thrilled to introduce the Temu coupon code 30% off, a deal that’s bound to excite all online shoppers! With this amazing offer, you'll save significantly while still enjoying a wide range of products on the Temu platform. Our exclusive coupon code, [acu729640], brings maximum benefits to individuals residing in regions such as the USA, Canada, the Middle East, and several European nations. This code is specially designed to provide international users with unmatched savings and a seamless shopping experience. For those eagerly awaiting 2024, the Temu coupon code 2024 for existing customers is here, accompanied by the fantastic Temu 30% discount coupon. This promotion ensures that both new and existing users get the most out of their shopping journey on Temu. What Is The Temu Coupon Code 30% Off? The Temu coupon 30% off is your gateway to incredible savings on Temu’s app and website. Whether you're a new user or an existing customer, using our 30% off Temu coupon code gives you access to great deals and discounts. [acu729640]: This code grants new users a flat 30% off on their first purchase. [acu729640]: Existing users can enjoy a 30% extra discount when using this code. [acu729640]: New Temu customers can benefit from a flat $100 off. [acu729640]: Unlock a $100 coupon pack usable on multiple purchases. [acu729640]: Exclusive $100 flat discount specifically for new Temu users in the USA, Canada, and Europe. [acu729640]: Existing customers can receive an additional $100 off with a promo code. [acu729640]: Special $100 coupon available for users in the USA, Canada, and Europe. Temu Coupon Code 30% Off For New Users For those new to the Temu platform, the Temu coupon 30% off offers the highest savings potential. Experience a world of rewards and benefits with the Temu coupon code 30 off for existing users, now accessible to all first-time shoppers. [acu729640]: Secure a flat 30% discount as a new user. [acu729640]: Old users receive an additional 30% discount benefit. [acu729640]: Access a $100 coupon bundle for new customers. [acu729640]: Benefit from up to $100 in a coupon bundle for multiple uses. [acu729640]: Free shipping to an impressive list of 68 countries. [acu729640]: First-time users get an extra 50% off on any purchase. How To Redeem The Temu 30% Off Coupon Code For New Customers? Unlocking the Temu 30% off deal is a breeze with our Temu 30 off coupon code. Follow these simple steps for redemption: Visit the Temu app or website and create an account as a new user. Browse through the extensive catalog and add your desired items to the cart. At checkout, enter the coupon code [acu729640] in the designated field. Verify that the 30% discount has been applied to your total. Complete the purchase with your preferred payment method. Temu Coupon Code 30% Off For Existing Users Existing Temu users can continue to enjoy savings with the Temu 30 off coupon code. Our Temu coupon code for existing customers ensures you don’t miss out on top deals. [acu729640]: Existing Temu users receive an extra 30% discount. [acu729640]: Secure a $100 coupon bundle applicable for multiple purchases. [acu729640]: Enjoy a free gift with express shipping across the USA and Canada. [acu729640]: An extra 50% off layered onto existing discounts. [acu729640]: Free shipping across 68 countries globally. How To Use The Temu Coupon Code 30% Off For Existing Customers? To leverage the Temu coupon code 30 off as an existing customer, follow these easy steps with the Temu discount code for existing users: Log in to your Temu account on the app or website. Choose items from a diverse selection and add them to your cart. At checkout, input the code [acu729640] in the coupon code box. Confirm the additional 30% discount on your order. Proceed to pay and complete your purchase. How To Find The Temu Coupon Code 30% Off? Finding the best Temu coupon code 30% off first order and the latest Temu coupons 30% off is a straightforward process. We recommend signing up for the Temu newsletter to receive verified and tested coupon codes directly in your inbox. Additionally, visiting Temu’s social media pages will keep you updated on the latest promos and offers. Trustworthy coupon sites are also a reliable source for discovering the most current and valid Temu coupon codes. How Does Temu 30% Off Coupons Work? The Temu coupon code 30% off first-time user offers a substantial discount on your first purchase, making it an irresistible deal for new Temu shoppers. Simply apply the Temu coupon code 30 percent off at checkout, and watch the savings roll in. This initiative not only facilitates budget-friendly shopping but also introduces new users to the exceptional range of products available on Temu. The coupons work seamlessly, offering significant savings across a vast selection without any hidden conditions. How To Earn 30% Off Coupons In Temu As A New Customer? To earn the Temu coupon code 30% off, new customers need to sign up on the Temu platform and explore the introductory offers. Our Temu 30 off coupon code first order is designed to reward first-time users with an enviable discount. Besides the initial welcome deals, new customers can participate in Temu’s promotional events, referral programs, and social media campaigns to earn additional savings. These efforts ensure customers can consistently enjoy discounts on every purchase. What Are The Advantages Of Using Temu 30% Off Coupons? Temu 30% off coupon code legit: Verified discounts ensuring legitimate savings. Coupon code for Temu 30 off: 30% reduction on your first order. $100 coupon bundle applicable for multiple transactions. Up to 70% discount on popular items sitewide. Extra 30% off for returning Temu customers. Discounts of up to 90% on selected items. Free gift provided for new users. Free delivery to 68 countries worldwide. Temu Free Gift And Special Discount For New And Existing Users With the Temu 30% off coupon code, everyone can take advantage of multiple benefits. The 30% off Temu coupon code brings you closer to special offers and exclusive gifts. [acu729640]: Enjoy a 30% extra discount on your first order. [acu729640]: An additional 30% off any item in your cart. [acu729640]: Free gifts available for new Temu users. [acu729640]: Receive up to 70% off any item on the Temu app. [acu729640]: Free gift with complimentary shipping to 68 countries, including the USA and UK. Pros And Cons Of Using Temu Coupon Code 30% Off Pros: Temu coupon 30% off code: Provides significant savings across the platform. Wide range of applicable products. Available for use in multiple countries. Free shipping benefits enhance value. No expiration date adds flexibility. Cons: Temu free coupon code 30 off might not be combinable with other deals. Limited to certain product categories. Seasonal availability can vary. Terms And Conditions Of The Temu 30% Off Coupon Code In 2024 Temu coupon code 30% off free shipping: Available for all orders with no minimum purchase required. Temu coupon code 30% off reddit: Community-tested and endorsed. No expiration date; use whenever convenient. Valid for both new and existing users in 68 countries. All purchases qualify with no minimum spend required. Final Note With the Temu coupon code 30% off, your shopping experience is about to reach new heights. Whether you're a new or existing customer, the Temu 30% off coupon promises unbeatable value and convenience. FAQs Of Temu 30% Off Coupon How can I use the Temu 30% off coupon code? Visit the Temu website or app, add items to your cart, and enter the coupon code [acu729640] at checkout to enjoy your discount. Can existing customers get a discount with this coupon code? Yes, the coupon provides existing customers with an additional 30% off on their purchases. Is the Temu coupon code valid for international users? Absolutely! The coupon code is available to users in 68 countries, including the USA, Canada, and several European nations. Are there any restrictions on the Temu 30% off coupon code? No, there are no minimum purchase requirements, and the code can be used at any time. How often can I use the Temu coupon code? The Temu coupon code can be used multiple times, especially if you’re a new user benefiting from the first purchase offer.
Last updated: 2024-10-26
Post by kamalsingh on Temu Coupon Code $100 Off → [^•^''acr552049^•^''] First Order in Canada→→
CODESYS Forge
talk
(Post)
Canada Temu Coupon Code $100 Off ➥ [acu577459 & acq615756], TEMU Coupon Code "[acu577459 & acq615756]" | $100 Off & 50% Coupon, TEMU Coupon Code "[acu577459 & acq615756]" ,is an all in one opportunity, which also offers $100 Off & 50% Coupon! The TEMU Coupon Code "[acu577459 & acq615756]" & acq523557offers an impressive $100 Coupon and a 50% Coupon on purchases for both new and existing customers. This special offer is a fantastic opportunity to save significantly on your TEMU shopping experience. By using the Coupon Code "[acu577459 & acq615756]", you can unlock the $100 Coupon bundle, which provides $120 worth of savings. This means that you can enjoy a $100 Coupon on your order, as well as access to exclusive deals and additional savings opportunities. ⇦ Exclusive Temu CouponCodes ,,,[acu577459 & acq615756],,,,, ➤ Offers → Coupons, Student Deals & More ╰┈➤ Best Temu Coupon Codes➤ "[acu577459 & acq615756]" ⇨ "acq523557" ➥ Up to 50% Off Canada To redeem the TEMU $100 Coupon Code, simply follow these steps: Sign up for a TEMU account on their website or mobile app. Add items worth $100 or more to your shopping cart. During checkout, enter the Coupon Code "[acu577459 & acq615756]" in the designated field. The $100 Coupon will be automatically applied, and you can also enjoy an additional 50% off on your purchase. This Coupon Code is valid for both new and existing TEMU customers, making it a great opportunity for everyone to save on their shopping. The $100 Coupon bundle can be combined with other available Coupons, such as the 30% off code for fashion, home, and beauty categories, allowing you to maximize your savings. ➥ Temu Coupon Code $100 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 40 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 50 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 70 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 90 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 30 Off {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code First Order {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code Existing User {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code 90 Off {[acu577459 & acq615756]} or {[acu577459 & acq615756]} Canada ➥ Temu Coupon Code |"$100 Off"| [[acu577459 & acq615756]] For New and Existing Customers Canada ➥ Temu Coupon Code |"$100 Off"| [[acu577459 & acq615756]] First-time users Canada Temu Coupon Code $100 Off [[acu577459 & acq615756]] For New Users 2024 Canada Temu has rapidly gained popularity as a go-to shopping destination, offering a vast array of trending products at unbeatable prices. To welcome new users, Temu is excited to offer the exclusive Temu Coupon code $100 Off [[acu577459 & acq615756]]& acq523557]. Alongside this, existing customers can enjoy significant savings with the [acu577459 & acq615756] Coupon code. Why You Should Embrace Temu Coupon Codes Canada Temu has revolutionized online shopping by providing an extensive range of products, from fashion and electronics to home goods and accessories. Coupled with fast delivery and free shipping to numerous countries, Temu has become a preferred choice for budget-conscious shoppers. Now, imagine enjoying these benefits with an additional $100 Off your purchase! That's where our Temu Coupon codes come in. Unveiling Top Temu Coupon Codes for October 2024 Canada To maximize your savings, consider these exceptional Temu Coupon codes: [acu577459 & acq615756]: $100 Off for new users - A fantastic welcome offer. [acu577459 & acq615756]: $100 Off for existing customers - A reward for loyalty. [acu577459 & acq615756]: $100 extra off - Boost your savings significantly. [acu577459 & acq615756]: Free gift for new users - A delightful surprise. [acu577459 & acq615756]: $100 Coupon bundle - A comprehensive savings package. Navigating the Path to Temu Savings Canada Redeeming your Temu Coupon code is a straightforward process: Create a Temu account or log in to your existing one. Explore Temu's vast collection and add your desired items to your cart. Proceed to checkout and apply your Coupon code at the designated box. Witness the magic unfold as your Coupon is instantly applied to your order total. Unlock Extraordinary Savings with Temu Coupon Code $100 Off [[acu577459 & acq615756]] The Temu Coupon code $100 Off [[acu577459 & acq615756]] is a fantastic opportunity for new users to experience the Temu shopping thrill with significant savings. Imagine purchasing your favourite items at a Couponed price. This Coupon empowers you to enjoy a wide range of products without breaking the bank. Unleash the Power of Temu Coupon Codes Canada Flat $100 Coupon: Enjoy a substantial reduction on your entire order. Canada $100 Coupon for new users: A generous welcome offer for first-time shoppers. Canada $100 Off for existing customers: A reward for your loyalty to Temu. Canada $100 Coupon for new customers: A fantastic incentive to try Temu. Canada Temu $100 Off for old users: A token of appreciation for your continued support.Canada Elevate Your Temu Shopping Experience To optimize your savings journey on Temu, consider these expert tips: Leverage free shipping: Enjoy complimentary delivery on your orders. Canada Explore diverse product categories: Uncover hidden gems and unexpected finds. Canada Stay alert for daily deals and flash sales: Seize limited-time opportunities. Canada Combine Coupons with other Coupons: Maximize your savings potential. Canada Share your shopping experience: Leave reviews to help others and potentially earn rewards. Canada Utilize social media: Follow Temu on platforms like Instagram and Facebook for exclusive deals and Coupontions. Canada Join Temu's email list: Stay informed about the latest offers and product launches. Canada Essential Temu Coupon Codes for Unmatched Savings To further enhance your shopping adventure, explore these indispensable Temu Coupon codes: [acu577459 & acq615756]: Temu Coupon $100 Off for new users Canada [acu577459 & acq615756]: Temu Coupon code $100 Off for existing customers Canada [acu577459 & acq615756]: Temu Coupon codes 100% Canada [acu577459 & acq615756]: Temu Coupon $100 Off code Canada [acu577459 & acq615756]: Temu Coupon $100 Off first-time user Canada Temu Coupon Codes for August 2024: The Key to Massive Coupons This month, Temu offers several enticing Coupon codes tailored to both new and existing users, ensuring everyone can save. Here’s a quick look at the top Temu Coupon codes you can take advantage of this August: [[acu577459 & acq615756]]: Temu Coupon code $100 Off for new users [[acu577459 & acq615756]]: Temu Coupon code 40% off for new customers [[acu577459 & acq615756]]: Temu Coupon code 40% extra off [[acu577459 & acq615756]]: Temu Coupon code for a free gift for new users [[acu577459 & acq615756]]: Temu $100 Coupon bundle for existing and new users These Temu Coupon codes offer a variety of benefits, from substantial Coupons to free gifts and bundled savings. Whether you’re shopping for fashion, electronics, home goods, or more, these codes will ensure you get the best deal possible. Whether you're a seasoned Temu shopper or a new customer, these Coupon codes offer an incredible opportunity to save on your purchases. Remember, the Temu Coupon code $100 Off [[acu577459 & acq615756]] is a limited-time offer. Don't miss out on this fantastic chance to enjoy significant savings! Embark on your Temu shopping spree today and experience the thrill of unbeatable prices. Temu Coupon Code-{[acu577459 & acq615756]} Canada Temu Coupon Code: $100 Off{[acu577459 & acq615756]} Canada Temu Coupon Code: Free Shipping{[acu577459 & acq615756]} Canada Temu $100 Off Code{[acu577459 & acq615756]} Canada Temu 50% Coupon Coupon{[acu577459 & acq615756]} Canada Temu $120 Coupon Bundle Code{[acu577459 & acq615756]}{[acu577459 & acq615756]} Canada Temu Student Coupon Coupon Code{[acu577459 & acq615756]} Canada temu existing user Coupon code Canada Using Temu's Coupon code [{[acu577459 & acq615756]}] will get you $100 Off, access to exclusive deals, and benefits for additional savings. Save 40% off with Temu Coupon codes. New and existing customer offers. Canada temu Coupon code May 2024- {[acu577459 & acq615756]} Canada temu new customer offer{[acu577459 & acq615756]} Canada temu Coupon code 2024{[acu577459 & acq615756]} Canada 100 off Coupon code temu{[acu577459 & acq615756]} Canada temu 100% off any order{[acu577459 & acq615756]} Canada 100 dollar off temu code{[acu577459 & acq615756]} Canada What is Temu $100 Coupon Bundle? Canada New Temu $100 Coupon bundle includes $120 worth of Temu Coupon codes. The Temu $100 Coupon code "{[acu577459 & acq615756]}" can be used by new and existing Temu users to get a Coupon on their purchases. Enjoy $100 Off at Temu with Coupon Code [[acu577459 & acq615756]] – Exclusive for October and October 2024! Looking for incredible savings on top-quality products at Temu? Whether you're new to Temu or a seasoned shopper, our special Coupon code [[acu577459 & acq615756]] offers you an exclusive chance to save $100 on your purchases throughout August and October 2024. Here's everything you need to know to take full advantage of this fantastic offer. For New Customers: 1. Sign Up and Save Big: • Download the Temu App: Start by downloading the Temu app from your smartphone's app store or visit the Temu website using your computer. Temu's user-friendly interface ensures a smooth shopping experience. • Create an Account: Register for a new account by providing your basic details. This process is quick and straightforward, and it unlocks your access to a $100 Coupon. • Browse and Add to Cart: Explore Temu's extensive range of products, from stylish fashion items to cutting-edge electronics and home essentials. Add items totaling $100 or more to your cart. This ensures that you meet the minimum purchase requirement to use the Coupon code. 2. Apply Your Coupon Code: • Proceed to Checkout: Once you've filled your cart, go to the checkout page. Here, you'll see a field labeled "Coupon Code" or "Coupon Code." • Enter Code [[acu577459 & acq615756]]: Input the Coupon code [[acu577459 & acq615756]] into the designated field and click "Apply." The $100 Coupon will be automatically applied to your total. • Review and Complete Purchase: Verify that the Coupon has been applied to your order. Complete the payment process and enjoy your shopping spree with a $100 Coupon! Tip for New Customers: This exclusive offer is valid only during August and October 2024. Make sure to use the code [[acu577459 & acq615756]] within this period to maximize your savings. For Existing Customers: 1. Shop and Save with Ease: • Log Into Your Account: If you're a returning Temu shopper, simply log into your existing account on the Temu app or website. • Explore and Add Items: Browse through the extensive product catalog. From the latest gadgets to home decor, add items totaling $100 or more to your cart. • Prepare for Checkout: Proceed to the checkout page where you'll be able to apply your Coupon. 2. Redeem Your Coupon Code: • Enter Coupon Code [[acu577459 & acq615756]]: In the "Coupon Code" field at checkout, enter [[acu577459 & acq615756]] and click "Apply." The $100 Coupon will be applied to your order total. • Check and Complete Purchase: Confirm that the Coupon has been applied correctly to your order. Finalize the payment details to complete your purchase. Tip for Existing Customers: This offer can be combined with other Coupon available during August and October, so keep an eye out for additional savings opportunities!
Last updated: 2024-10-26
Post by frank1001 on Codesys läuft nicht hoch
CODESYS Forge
talk
(Post)
Bin Neuling bei Codesys. Habe Codesys 64 Bit installiert (3.5.1) Nach dem Starten geht nur ein EIngabefenster auf mit folgenden Inhalt. Weiter passiert nichts. Was kann ich machen ? //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// _/_/_/_/ _/_/_/_/ _/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/ _/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/_/ _/_/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/_/_/_/ // // // // // //// //// //// //// /////// // // // // // // // // // // ///// ////// ////// ////// ////// ////// // ////// /// //// //// ///// ////// ///// // ///// _/ //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuBreakpoints</cmp>, <id>0x00000305</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFileStream</cmp>, <id>0x00000120</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysGraphicGDIPlus</cmp>, <id>0x0000012a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInt</cmp>, <id>0x00000106</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeCommonControls</cmp>, <id>0x00000138</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeControl</cmp>, <id>0x0000012f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPci</cmp>, <id>0x0000010c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPort</cmp>, <id>0x0000010d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindow</cmp>, <id>0x00000117</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindowFileDialog</cmp>, <id>0x0000011a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysTargetSoftMotion</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysReadWriteLock</cmp>, <id>0x0000013e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvCom</cmp>, <id>0x00000006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvShm</cmp>, <id>0x00000068</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvC</cmp>, <id>0x00000066</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIpc</cmp>, <id>0x0000001d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor</cmp>, <id>0x00000014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpObjectMgr</cmp>, <id>0x00000080</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSercos3Master</cmp>, <id>0x0000004c</id> <ver>3.1.2.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSupervisor</cmp>, <id>0x0000008f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuClientControllerHost</cmp>, <id>0x00000132</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpTargetVisuStub</cmp>, <id>0x00000053</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= MultiCore support: [activated], all cores are used 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= Number of available cores: 8 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.1.167</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 0</interface> at router <instance>0</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.56.1</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 3</interface> at router <instance>1</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=2, pszInfo= Running as network server 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=1, pszInfo= Running as network client 2023-09-19T08:02:04.077Z: Cmp=CmpChannelServer, Class=1, Error=0, Info=0, pszInfo= <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2023-09-19T08:02:04.265Z: Cmp=CmpRedundancy, Class=1, Error=0, Info=0, pszInfo= Debug Messages not activated 2023-09-19T08:02:04.266Z: Cmp=CmpRedundancyConnectionIP, Class=1, Error=0, Info=0, pszInfo= Read connection settings... 2023-09-19T08:02:05.456Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvShm</interface> at router <instance>2</instance> registered 2023-09-19T08:02:05.456Z: Cmp=CmpBlkDrvShm, Class=1, Error=0, Info=9, pszInfo= Local address (BlkDrvShm) set to 1 2023-09-19T08:02:05.463Z: Cmp=CmpBlkDrvTcp, Class=1, Error=0, Info=6, pszInfo= Local network address: <ipaddress>192.168.56.1</ipaddress> 2023-09-19T08:02:05.464Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvTcp</interface> at router <instance>3</instance> registered 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= No certificate for the OPC UA server available. 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Security policy allows plain text communication. Secure communication is deactivated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ********** 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= OPC UA Server Started: 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Hostname: SIEMENS, Port: 4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= URL: opc.tcp://SIEMENS:4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Loopbackadapter activated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= All available networkadapters are used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Multithreading activated. 7 workers used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ************ 2023-09-19T08:02:05.513Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'CODESYS_DefaultProvider' (version 0x3051300) registered at the OPC UA server. 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= CODESYS SoftMotion Win V3 x64 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= OS=Windows, CPU=x86, Arch=64Bit, Coding=C 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=6, pszInfo= <version>3.5.19.20</version> <builddate>Aug 1 2023</builddate> 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=5, pszInfo= Copyright CODESYS Development GmbH 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.529Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AddressSpaceFragment Provider' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'OPC UA for IEC-61131-3' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AlarmManager' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>0</instance> address to (00a7) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>1</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>2</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>3</instance> address to (2ddc:c0a8:3801) 2023-09-19T08:02:05.611Z: Cmp=CM, Class=1, Error=0, Info=34, pszInfo= CODESYS Control ready 2023-09-19T08:02:05.796Z: Cmp=CM, Class=2, Error=0, Info=0, pszInfo=!!!! no runtime license - running in demo mode(~2 hours)
Last updated: 2023-09-19
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.