Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue
CODESYS Forge
talk
(Post)
Ok, so i made some tests in the meantime and i have some conclusions. It apears that the enable bit is activated only when a motion function is executed. I implemented a very simple program with MC_Power and MC_Jog. If i enable everything on MC_Power, the enable GPIO pin stays off. However, as soon as the MC_Jog function is used the enable GPIO pin turns ON and remains ON. In version 0.0.0.4 this is not happening. The GPIO enable pin turns on or off when the MC_Power is enabled or disabled. From this behaviour i understand that in version 0.0.0.6 the GPIO enable bit is activated together with pulse and dir pins when motion starts. When motion stops, enable bit remains with the last state (on in this case) and you cannot turn it off for example. For me this bit is useful because i can turn on and off the stepper drive with MC_Power function. Now i can turn it on, but never off.
Last updated: 2025-04-04
Post by jschu on Dynamical scaling of bar graph without the bar itself
CODESYS Forge
talk
(Post)
Hi there, Task: dynamical changing the scaling of an bar graph, linear scaling whitout showing the bar only the scaling values and Lines for Main and partial steps. Define 4 Limits for Hi and LO Values with different colors Option 1 : use the bar graph whitout showing the actual bar whitout showing the bar, only the scaling values and lines for main and partial steps. Then what to do with the 4 Limits ? I could use 4 moveable Rectangles with the start and end value fo the areas but then the whoel bargraph must be transparent. Best way would be if only the scale ist possible to show as it is possible for the Meter 180° but this option does not exist for the bargraph. Option 2 : user defined HMTL5 Widgets wich may be some allreay has created or where is a dome for using this kind of html5 widget. The expanse for use html is in my eyes to big and gives more option for errors. Have some one experience in this topic or a hint how to do it the easiest way? Thanks for your help.
Last updated: 2025-05-15
Post by elizaduke92 on Temu Ilk Alışveriş Indirim Kodu [acu639380] %40 Indirim Kazanın
CODESYS Forge
talk
(Post)
E-ticaret dünyasında alışveriş yaparken tasarruf etmek herkesin istediği bir şeydir. Bu nedenle, Temu coupon code 40% off ile ilk alışverişinizde büyük indirim fırsatlarını kaçırmamalısınız. Bu özel acu639380 Temu indirim kodu, Türkiye'deki kullanıcılar için maksimum avantajlar sunuyor. Alışveriş yaparken bu kodu kullanarak tasarruf etmenin mutluluğunu yaşayacaksınız. Ayrıca, Temu coupon code 2024 for existing customers ve Temu 40% discount coupon ile mevcut müşterilere de birçok avantaj sağlanmaktadır. Hem yeni hem de mevcut kullanıcılar için harika fırsatlar sunuluyor. Temu Coupon Code 40% Off Nedir? Temu uygulaması ve web sitesinde, hem yeni hem de mevcut müşteriler için harika fırsatlar sunan Temu coupon 40% off kodunu kullanabilirsiniz. Bu kodu kullanarak 40% discount Temu coupon ile tasarruf etmenin keyfini çıkaracaksınız. acu639380: Yeni kullanıcılar için %40 düz indirim. acu639380: Mevcut kullanıcılar için %40 indirim. acu639380: Birden fazla kullanım için 100$ kupon paketi. acu639380: Yeni müşteriler için 100$ düz indirim. acu639380: Mevcut müşteriler için ekstra 100$ indirim kodu. Temu Coupon Code 40% Off Yeni Kullanıcılar İçin Yeni kullanıcılar, Temu uygulamasında indirim kodunu kullanarak en yüksek faydayı elde edebilirler. Temu coupon 40% off ve Temu coupon code 40 off for existing users ile alışveriş deneyiminizi zenginleştirebilirsiniz. acu639380: Yeni kullanıcılar için %40 düz indirim. acu639380: Yeni müşterilere özel 100$ kupon paketi. acu639380: Birden fazla kullanım için 100$ kupon paketi. acu639380: Türkiye'ye ücretsiz kargo imkanı. acu639380: İlk kez alışveriş yapanlar için ekstra %30 indirim. Temu 40% Off İndirim Kodunu Nasıl Kullanırım? Temu 40% off kodunu kullanmak oldukça basittir. İşte adım adım nasıl yapacağınız: Temu uygulamasını veya web sitesini açın. Alışveriş yapacağınız ürünleri sepetinize ekleyin. Sepete gidin ve “İndirim Kodu” bölümüne acu639380 yazın. İndiriminizi görün ve siparişinizi tamamlayın. Temu Coupon Code 40% Off Mevcut Kullanıcılar İçin Mevcut kullanıcılar da Temu uygulamasında indirim kodunu kullanarak avantaj elde edebilirler. Temu 40 off coupon code ve Temu coupon code for existing customers ile alışverişinizi daha keyifli hale getirin. acu639380: Mevcut Temu kullanıcıları için %40 ekstra indirim. acu639380: Birden fazla satın alma için 100$ kupon paketi. acu639380: Türkiye genelinde hızlı kargo ile ücretsiz hediye. acu639380: Mevcut indirimlerin üzerine ekstra %30 indirim. acu639380: Türkiye’ye ücretsiz kargo imkanı. Temu 40% Off İndirim Kodunu Mevcut Kullanıcılar Nasıl Kullanır? Temu coupon code 40 off kullanmak için aşağıdaki adımları izleyin: Temu uygulamasını veya web sitesini açın. Ürünlerinizi sepetinize ekleyin. Sepet sayfasında “İndirim Kodu” bölümüne acu639380 yazın. İndiriminizi görün ve siparişinizi tamamlayın. Temu Coupon Code 40% Off Nasıl Bulunur? Temu coupon code 40% off first order ve latest Temu coupons 40 off bulmak oldukça kolaydır. Temu bültenine abone olarak doğrulanmış kuponları alabilirsiniz. Ayrıca, Temu’nun sosyal medya hesaplarını takip ederek en güncel kampanya ve promosyonları öğrenebilirsiniz. Güvenilir kupon sitelerini ziyaret ederek en yeni ve geçerli Temu kupon kodlarını bulabilirsiniz. Temu 40% Off Kuponları Nasıl Çalışır? Temu coupon code 40% off first time user ile alışveriş yaparken, kullanıcılar %40 indirim kazanabilir. İndirim kodunu kullandığınızda, sepetinizdeki toplam tutar üzerinden indirim uygulanır. Bu kodlar, kullanıcıların alışveriş deneyimlerini daha uygun hale getirmek için tasarlanmıştır. Kupon kodu uygulandığında, kullanıcılar büyük tasarruflar yapabilirler. Yeni Müşteriler İçin Temu 40% Off Kuponlarını Nasıl Kazanabilirsiniz? Temu coupon code 40% off ile yeni müşteriler, alışverişlerinde büyük indirimler kazanabilirler. Yeni kullanıcılar, kayıt sırasında veya ilk alışverişlerinde bu kodu kullanarak tasarruf edebilirler. Kayıt işlemi sırasında, genellikle indirim kodu ile birlikte çeşitli promosyonlar sunulmaktadır. Bu sayede, alışverişlerinizde önemli avantajlar elde edebilirsiniz. Temu 40% Off Kuponlarının Avantajları Nelerdir? Temu 40% off coupon code legit ve coupon code for Temu 40 off kullanmanın birçok avantajı vardır: İlk alışverişte %40 indirim. Birden fazla kullanım için 100$ kupon paketi. Popüler ürünlerde %70'e varan indirim. Mevcut Temu kullanıcıları için ekstra %30 indirim. Seçili ürünlerde %90'a varan indirim. Yeni kullanıcılara ücretsiz hediye. Türkiye’ye ücretsiz kargo imkanı. Temu Ücretsiz Hediye ve Özel İndirimler Temu 40% off coupon code ve 40% off Temu coupon code kullanarak birçok avantaj elde edebilirsiniz. Bu fırsatlarla alışveriş deneyiminizi zenginleştirin. acu639380: İlk alışverişte %40 indirim. acu639380: Mevcut müşterilere %40 indirim. acu639380: Herhangi bir ürün üzerinde ekstra %30 indirim. acu639380: Yeni Temu kullanıcılarına ücretsiz hediye. acu639380: Temu uygulamasında herhangi bir üründe %70'e varan indirim. acu639380: Türkiye'ye ücretsiz kargo ile hediye. Temu İndirim Kodu 40% Off Kullanmanın Artıları ve Eksileri Temu coupon 40% off code ve Temu free coupon code 40 off kullanmanın bazı artıları ve eksileri vardır: Artılar: %40 indirim fırsatı. Ücretsiz kargo imkanı. Birden fazla kullanım avantajı. Hediye kampanyaları. Popüler ürünlerde büyük indirimler. Eksiler: Belirli ürünlerde geçerli olmayabilir. İndirim kodunun kullanılmadığı bazı kampanyalar. Belirli bir süreyle sınırlı olabilir. Temu 40% Off İndirim Kodunun 2024 Şartları ve Koşulları Temu coupon code 40% off free shipping ve Temu coupon code 40% off reddit hakkında bilgi sahibi olun. İşte bu kuponların şartları: İndirim kodlarının son kullanma tarihi yoktur, istedikleri zaman kullanılabilir. Kupon kodları hem yeni hem de mevcut kullanıcılar için geçerlidir. Kullanıcıların indirim kodunu kullanabilmesi için herhangi bir minimum alışveriş tutarı gerekmemektedir. Son Not Temu coupon code 40% off ile harika fırsatları kaçırmayın. Bu indirim kodu, alışverişlerinizde tasarruf yapmanızı sağlıyor. Ayrıca, Temu 40% off coupon kullanarak büyük avantajlar elde edebilir, alışveriş deneyiminizi zenginleştirebilirsiniz. Temu 40% Off İndirim Kodu ile İlgili Sıkça Sorulan Sorular Temu 40% indirim kodunu nasıl kullanabilirim? Temu uygulamasında alışveriş yaparken sepetinizde indirim kodunu girerek kullanabilirsiniz. Bu indirim kodu ne zaman geçerli? İndirim kodu sürekli olarak geçerlidir, yani istediğiniz zaman kullanabilirsiniz. İndirim kodu yalnızca yeni kullanıcılar için mi? Hayır, hem yeni hem de mevcut kullanıcılar için geçerlidir. Temu indirim kodu hangi ürünlerde geçerli? Genellikle tüm ürünlerde geçerli, ancak bazı sınırlamalar olabilir. İndirim kodunun bir son kullanma tarihi var mı? Hayır, bu kodların herhangi bir son kullanma tarihi yoktur.
Last updated: 2024-10-26
Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection
CODESYS Forge
talk
(Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03
Post by bschraud on runtime received SIGABRT
CODESYS Forge
talk
(Post)
Hallo, seit der Umstellung meines Projektes auf die aktuelle Codesys Version mit aktuellen Bibliotheken und Aktualisierung der Runtimer Version bekomme ich im Zeitraum 15min bis 1h nach Neustart des Target Systems folgende Fehlermeldung: runtime received SIGABRT - system may be in an inconsistent state Der Fehler kommt auch nach dem Start des Systems ohne eine Benutzeraktion zuverlässig, aber in unterschiedlichen Zeiträumern. Hier sind die Logs und Daten, die ich dazu ermitteln konnte: $ tail -f /var/opt/codesys/codesyscontrol.log 2025-04-03T06:54:37.659Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 594337835 2025-04-03T06:54:37.660Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 594337835 Returned IEC-ID: 0 2025-04-03T07:01:38.135Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:01:38.135Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-04-03T07:02:18.181Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:02:18.181Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE $ vmstat 1 procs -----------memory---------- ---swap-- -----io---- -system-- ------cpu----- r b swpd free buff cache si so bi bo in cs us sy id wa st 1 0 0 271120 33976 342284 0 0 135 2 2387 4751 10 7 82 1 0 1 0 0 271024 33976 342380 0 0 0 0 10163 20427 10 9 81 0 0 1 0 0 271056 33976 342380 0 0 0 0 8455 16869 9 5 86 0 0 0 0 0 271040 33976 342380 0 0 0 0 8674 17484 9 4 87 0 0 0 0 0 271072 33976 342380 0 0 0 0 10070 20350 7 7 87 0 0 1 0 0 271040 33976 342380 0 0 0 0 10354 20802 10 6 84 0 0 0 0 0 271072 33976 342380 0 0 0 0 8401 16923 8 6 86 0 0 $ vcgencmd measure_temp temp=56.9'C $ uname -a Linux PAC4 5.10.103-v7+ #1529 SMP Tue Mar 8 12:21:37 GMT 2022 armv7l GNU/Linux CODESYS V3.5 SP21 Runtime: Codesys control for Raspberry Pi MC SL V 4.13.0.0 Hinweise auf ein instabiles OS oder instabile Netzwerkverbindungen konnte ich keine finden. In dmesg und im syslog gibt es keine Auffälligkeiten. Die anderen Posts zu diesem Thema wurden nicht beantwortet. Hat jemand einen Tip, wie man an das Problem herangehen kann? Vielen Dank
Last updated: 2025-04-03
Post by vformanek on How to access files correctly in Linux
CODESYS Forge
talk
(Post)
Hello, its still not quite clear to me how to deal with the PLCLogic directory in linux. I have the directory right here: I need to correctly access the files in this folder through CODESYSControl.cfg. Here is my CODESYSControl.cfg where on the first lines there are a few lines: [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 That means that if I am going to use relative paths its going to go to from the PLCLogic directory right ? For example here: Whitch paths should I use. I cant seem to successfully run any of these aproaches ...
Last updated: 2023-09-08
Post by jari-koivuluoma on JSON_Utilities_SL JSONFileWriter error NULL_POINTER
CODESYS Forge
talk
(Post)
FB jsonFileWriter gives a NULL_POINTER error, why? JSONByteArrayWriter works fine so the JSONData FB should be fine. The device is CODESYS Control Win V3 x64 in simulation mode. Codesys version is V3.5 SP16 Patch 5 JSON_Utilities_SL version is 1.3.0.0 Src: ST_TestStruct1a; TXT: WSTRING(10000); MakeJSON : BOOL := TRUE; SrcJSONData: JSON.JSONData; jsonFileWriter : JSON.JSONFileWriter; IF MakeJSON THEN MakeJSON := FALSE; // Struct data to JSONData FB F_TestStructToJSON(ADR(Src),ADR(SrcJSONData)); // Writing to file jsonFileWriter( xExecute := TRUE, sFileName := 'c:\JSONTEST\JSON.txt', eEncoding := JSON.Encoding.UTF_16, xAsyncMode := TRUE, jsonData := SrcJSONData ); // Waiting to finish WHILE jsonFileWriter.xBusy DO ; END_WHILE // To text jsonArrayWriter( xExecute := TRUE, pwData := ADR(TXT), udiSize := SIZEOF(TXT), jsonData := SrcJSONData, xAsyncMode := FALSE, ); END_IF
Last updated: 2023-09-08
Post by lraja on Codesys Programming with phyBOARD®-Pollux i.MX8M Plus
CODESYS Forge
talk
(Post)
Dear All, I am trying to Developing a PLC using phyBOARD®-Pollux i.MX 8M Plus. It is very difficult to find the suitable Codesys control for i.MX8M. I have tried to install CODESYS Control for Linux ARM SL , but unable install it and I am getting the following error, [INFORMATION] Executing SSH command on root@192.168.0.10: Retrieving architecture from package management [ERROR] Expected exit value of command failed: expected 0, received 127 [INFORMATION] Standard output: sh: line 1: dpkg: command not found Kindly check and help phyBOARD®-Pollux i.MX 8M Plus Link : https://www.phytec.eu/en/produkte/single-board-computer/phyboard-pollux/
Last updated: 2023-09-23
Post by bahrt on Mapping GPIO and adding GPIO configurations
CODESYS Forge
talk
(Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are zero in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-16
Post by felipemsgarcia on Edge Gateway online, but PLC is not online
CODESYS Forge
talk
(Post)
Hello, Up until yesterday (2023/11/20) I was able to connect to the PLC remotely with no issues through Edge Gateway. However, today I can see the Edge Gateway online but I can find the PLC even if I do a network scan. Following the same path as janber0206 @ https://forge.codesys.com/forge/talk/automation_server/thread/e78b11d7e9/, I looked into certificates and found that one of the Trusted publisher certificates has expired earlier today (2023/11/21). Please see image. Questions are: Does it affect the connection to the PLC through Edge Gateway? How do I fix it? Thank you very much in advance!
Last updated: 2023-11-21
Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working
CODESYS Forge
talk
(Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22
Post by seppi on Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C.
CODESYS Forge
talk
(Post)
Hello everyone, I want to establish communication between my Arduino and my Raspberry Pi via I²C, but I have no idea how to make it work. However, it should work because there are many examples available, although none of them were programmed using Codesys, but rather using Python. My Raspberry Pi will be the master and is supposed to exchange measurement data such as speed and battery capacity with the slave (Arduino). I would be very grateful if someone could help me with my problem. Here is another link that could be helpful. However, I can't find the mentioned libraries
Last updated: 2023-12-03
Post by mohammadasif on Blink Function definition is wrong in codesys online help
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/en/libs/Util/Current/Signals/BLINK.html in the above link, please correct your website the following: "Output value, starts with FALSE and switches between TRUE and FALSE for the given high and low times" it should actually be: "Output value, starts with TRUE and switches between TRUE and FALSE for the given high and low times" if not please let me know if this has changed in a util library update, in your older website it has the right definition here: https://help.codesys.com/webapp/blink;product=codesys;version=3.5.11.0
Last updated: 2023-12-28
Post by idalu on Profinet PN_Controller Issue, Network Adapter
CODESYS Forge
talk
(Post)
i have a problem with Profinet on my project. I'm using Codesys RTE 3.5.19.50. When i download program to controller the ethernet is ok, PN_Controller is ok but every device i'm trying to connect is red with error "DCP no RealStationName". When i'm trying to Scan for Devices on PN_Controller there are no devices found. I have installed Codesys driver CmpEt1000Drv to my network adapter (i'm sure it is right intel pro 1000 model). I have noticed that when i installed codesys driver i'm no longer able to ping this network adapter (i can ping it when intel driver is installed). On my previous projects with runetimes i can ping it even with codesys driver installed. I have also tried to do downgrade of everything to version 3.5.19.20 and it not helped.
Last updated: 2024-01-17
Post by talpade on WAGO PLC 200 750-8216 Ethernet connection to Codesys 3.5
CODESYS Forge
talk
(Post)
Hello, I have the WAGO PLC 200 750-8210. In addition I have downloaded the "WAGO Devices and Libraries 2.0.4.3" and installed the library into the Codesys v 3.5. I then create a new project on Codesys 3.5 and select the device "750-8216 PFC200 (WAGO)" (which I downloaded from the WAGO library). However when I have connected the ethernet cable from the WAGO device to my computer and on my codesys 3.5 i press "Scan Network" on codesys and it does not detect the device. How can I get it to detect the device? (I have put the ethernet cable from my WAGO to the computer, but it does not show the device).
Last updated: 2024-02-05
Post by riccardo on Web Browser special tools errors
CODESYS Forge
talk
(Post)
Goodmoning everyone, I hope a codesys tecnichian will see this post. I serched on the forum and I found many topic about this tool but very few reaplies. I am tring to use the Web Browser tool, but it doesn't seem to work properly. I put several links in several forms: https://google.com http://google.com/ http://www.google.com http://www.google.com/ http://www.studiojomega.it/ . . . https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm But I obtain always errors; mainly 400 and 404 and in the normal visu this message appears "www.Google.com has refuse the connection". Is the codesys browser able to work as every other browser or has it some limitation? There is some particular precaution to consider when I pass the link to the codesys browser? Thanks in advance, Riccardo
Last updated: 2024-02-29
Post by nilesh on Request for Assistance with Online Logic Changes in PLC System using Codesys
CODESYS Forge
talk
(Post)
Dear Sir, We are writing to seek guidance regarding our current situation with the Opto 22 Groov EPIC PR1 PLC system. Over the past year, we have successfully downloaded and implemented logic using Codesys, and the PLC has been operational without issues. However, we now require minor modifications to the logic. Despite attempting to upload the modified logic, we are unable to see the "online change" option, prompting us to consider a direct logic download. Our concern is that during this process, certain digital outputs or analog outputs might momentarily disrupt operations, which is unacceptable given the system's continuous 24x7 operation. We have explored online changes in other PLC systems, but due to the absence of the last downloaded backup, we are unable to proceed confidently.
Last updated: 2024-03-01
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by albzen on EtherCat Slaves diagnosis
CODESYS Forge
talk
(Post)
Hello everybody, I'm working on a RunTime Plc (Codesys 3.5.16/18.20) connected to an EtherCat bus with many devices. The bus has some communication fault but I don't know how understand which is the device or the cable that has the trouble. To understand the cause of the problem I would like to read the WKC (Working counter) of the devices (0x0300...0x030C), how is explained in EtherCat documents, but it seems that the read of the counter is disabled. Attached there is an extract of the Ethercat document. Can anyone give me some advice about how and with function can I read it. Thank you in advance!
Last updated: 2024-03-29
Post by esave on Softmotion Light Problem: The license is missing or invalid
CODESYS Forge
talk
(Post)
Hello everybody I want to controll a stepper driver from Leadshine (EM3E-556E). The EtherCat slave is CiA 402 compatible. Because of this I bought the Softmotion Light Package from Codesys and implemented it in my project. I rightclicked the EtherCat slave and added the Softmotion Light axis. But now the error message shows: "The license is missing or invalid. The PLC runs in demo mode." What have i done wrong? I use Codesys 3.5.17. Is it possible that the stepper driver is not compatible with the Softmotion license? Thanks for all your help
Last updated: 2024-05-02
Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
CODESYS Forge
talk
(Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08
Post by timl on Application has invalid license metrics
CODESYS Forge
talk
(Post)
Hallo, ich habe eine Control for Linux SL auf der ich einen TCP Modbus Master anlege, mit dem ich einen Slave auslesen möchte. Das Anlegen funktioniert soweit alles, sobald ich beim ModbusTCPSlaveE/A-Abbild in den Channel eine Variable einfüge, damit ich den Channel auslesen kann, kommt es beim übertragen auf die SPS zu einem Ausnahmefehler. Im Anhang noch eine Bilder der Fehlermeldung und der installierten Lizenzen. CODESYS Version ist V3.5 SP19 Patch 4 Meinem Verständnis nach ist die Modbus Lizenz mit in der Control Standard L inbegriffen und auch in der Lizensierten Softwaremetrik sehe ich keine überschreitung meiner Lizenzbegrenzungen. Daher verstehe ich nicht wieso ich diesen Fehler bekomme und eine auslesung via Modbus nicht möglich ist. Gruß Tim
Last updated: 2024-05-08
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22
Post by kthomas on Cant login to Rpi4 but can see it in codesys communications settings.
CODESYS Forge
talk
(Post)
I have been struggling for over a week to program my rapspberry pi 4 with codesys. I purchased the license. I installed the runtime and the gateway, and I can see the pi in the communication settings. But cannot log in. I have checked the status of the pi with sudo systemctl status codesyscontrol and it is running. I have enabled traffic to and from the pi with iptables and checked the logs and all looks good. I just cannot connect through the codesys ide. Can anyone help me before I lose my mind?
Last updated: 2024-06-22