Post by jerry-sorrells on Find Function: Object reference not set to an instance of an object.
CODESYS Forge
talk
(Post)
Build: CODESYS 3.5 SP19 Patch 1 (64-bit) Host OS: Windows 10 Target: Linux SL I have a project with programs in Structured Text and Ladder Diagram. When I try to use the Find function, it works for the Active Editor; however, when I try to use Find for the Entire Project, I get the error "Object reference not set to the instance of an object." I know what this error means in the context of the program, but I have no idea why the find function is returning this error. The variable I am searching does not matter: it happens with all variables. Any help with this will be greatly appreciated. I generally use the Find function quite often as I am developing and not having it is really slowing me down.
Last updated: 2023-10-23
Post by tomast on WAGO 750-8212 nad Sinamics v20 modbus RTU speed control
CODESYS Forge
talk
(Post)
Hi Guys, I am new to this forum and i would like to ask od anyone got communication with Siemens v20 vfd working via Modbus RTU? I followed many websites and finally got the communication working but have problema with read/write registers. For example if i try to read holding register 40011 which is accel time i get noth but when i set the offset 0x0000 en length 113 i get ale the registers. I cannot get speed control working. I read someth about stw (control Word) and hsw but have some problems to understand it en get it working. It would be really nice if someone could help me with it. Thx
Last updated: 2024-03-05
Post by khaledkhalil on Import OPC UA model to Codesys
CODESYS Forge
talk
(Post)
I have added a models in SiOME which a software to design nodes and add instances. and created a resultant xml file. I tried to import the xml file to Codesys through OPC UA information model Repository the problem i don't know how to view my objects which i have designed. and map it to my PLC to make viewable on my server UaExpert. I watched the tutorial video https://youtu.be/aJhzN3Uk-Do?feature=shared. But it only give you how to add the Information model, and my resultant model doesn't have information type. So how in Codesys i can view a model which i have designed in SiOME and mapped my instances (Objects, Variable or methods) with my Variables in PLC I saw people do it in Tia Portal or other Software, but i have no clue how to do it on CODESYS
Last updated: 2024-03-12
Post by shrikantp007 on new to codesys help on modbus with ardunio modbus rtu
CODESYS Forge
talk
(Post)
Hello , I am new to codesys ,working with it for just 15-17 days so ,i think i am able to installed it and configure it ,not i want to use ardunio program (smart dustbin ,college project using motor and Ultrasonic Module HC-SR04 and servo motor). i use ardunio program to write code with chatgpt to work ardunio as a modbus rtu as i dont have ethernet or wifi shild ,i wrote program in ariduno but now don have idea what change i have to make in codesys to comunicate as modbus slave it give error with bus error ,where i can get all errors ? Thanks in advance :)
Last updated: 2024-07-21
Post by yannickasselin on codesys VLAN tagging
CODESYS Forge
talk
(Post)
Hi, I am looking for exactly the same thing. I would think that using a layer 2/3 managed switch should work but I am not convinced. I would like to test it in order to see if it would be possible to run many Codesys Docker instances on a server and run only 1 ethernet cable from the server to a managed switch closer to the machines beeing controlled instead of having to run multiple long ethernet cables. I was going to buy a managed switch in order to test it but I want to first make sure it is possible and I want to figure out exactly what kind of switch I would need. Is this even possible? I think this is a feature that would be very useful paired with "Codesys Virtual Control SL". Thank you
Last updated: 2024-09-07
Post by trent on Automation server - trends stop recording - need to manually reconnect
CODESYS Forge
talk
(Post)
Hi All, I use the analysis page in automation server to capture historical trends from my PLC - i only sample one point per hour but it does the job (for now) One issue I have is I often log on to analysis page to find the system has stopped recording trends from my PLC. To fix this, I need to choose "state information" in the "List view" under PLC and click "Reconnect" When I do this I see my variables listed under "parameters" under "PLC Details" start updating again and the trend in Data analyzer continues to update. My Question, Why do I need to manually reconnect? Is there a way to get automation server to automatically reconnect to the PLC so I continue to capture data from the PLC? Regards, Trent
Last updated: 2024-10-22
Post by timvh on CANbus issue
CODESYS Forge
talk
(Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14
Post by albertisa on GPIO Konfiguration auf SK-AM64B
CODESYS Forge
talk
(Post)
Hallo, seit einigen Tagen versuche ich erfolglos eine Ansteuerung der GPIOs des SK-AM64B Entwicklungsboards (Texas Instruments) über Codesys zu bewerkstelligen. Bei dem Versuch GPIOs anzusteuern, ohne die devdesc.xml bzw. den iodriver anzupassen, wird mir von Codesys die Fehlermeldung "Bus läuft nicht" (siehe Screenshot) angezeigt. Welche Vorgehensweise wird zur Konfiguration der IO empfohlen? Ist eine Anpassung der devdesc.xml und des IOdrivers notwendig? Wie wird am besten bei der Anpassung der genannten Dateien vorgegangen? Folgende Dokumentation ist mir bekannt, hat mir aber noch nicht weitergeholfen: https://forge.codesys.com/drv/io-drivers/doc/Generic/
Last updated: 2023-09-19
Post by nano on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
hello jdj this question can be answered well with a pretty good forge documentation: https://forge.codesys.com/drv/io-drivers/doc/Generic/ u r also able to create in codesys directly an iec-code by using the i2c-interface as driver using the codesys ide and st depending on the stepperdriver, used in yöur hat, its possible that an driver is already available in the device-repository. which mcp-device is used on the hat?
Last updated: 2024-03-01
Post by deeps on web visu on IFM
CODESYS Forge
talk
(Post)
I have an IFM cr1077 display. I would like to show B&R mapp view on IFM visualization. I used coedsys web browser elemnt for this. I could see IFM working fine in Internet web browser but IFM device shows white screen and freezes. I think there is problem with IFM showing the web browser. Is my understanding of the web visu right? am I doing any mistake here?
Last updated: 2023-08-18
Post by jeffgamsby on Accessing ModbusTCP addresses from python
CODESYS Forge
talk
(Post)
Hi, I am new to modbusTCP and I am trying to access Input registers from codesys (3.5.SP13). The offset is 16#0000 and I am trying to access Channel 1[24] %IW24 to pull analog values. I am using pyModbusTCP and I need to supply a modbus address and the number of registers to read. What does 16#0000 mean in terms of the actual offset, how do I translate this number plus the channel to access this info via python? Any help would be appreciated, thank you.
Last updated: 2023-09-20
Post by davidbo on RPI How to login for a copy of the SD image
CODESYS Forge
talk
(Post)
I had one RPI device where I could login. I copied the SD-flash over to another SC-flash. This new SD-flash was inserted in the new device. I can boot the new device but I cannot login why? How can I install an application on this new device? Control 4.4.0.0 cat os-release PRETTY_NAME="Raspbian GNU/Linux 11 (bullseye)" NAME="Raspbian GNU/Linux" VERSION_ID="11" VERSION="11 (bullseye)" VERSION_CODENAME=bullseye ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs"
Last updated: 2023-10-18
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by simover on TCP/IP client
CODESYS Forge
talk
(Post)
I want to send a string to a tics TCP/IP server. I got i working with the Net Base lib. for communication good with this tcis i need to by array of byte I want to include a string in the third position of the array TCIS_Send[1] :=254; //this valus is fix for evry communication TCIS_Send[2] :=80; //this valus is fix for evry communication TCIS_Send[3] := ; here I put my and my string is lik this 5806509-DRAP10#AB#3452302073 TCIS_Send[4] :=252; //this valus is fix for evry communication
Last updated: 2023-12-18
Post by josephbourgeois on Tracking out product
CODESYS Forge
talk
(Post)
Hi everyone! I synchronize the operation of the tripod and the conveyor. I have a problem with the product tracking algorithm on the conveyor (PCS_1). Sometimes I need to stop tracking a product on command without completing the operation. I do this using MC_GroupStop. But when I need to start moving in WCS again (using fb movelinearabsolute), I get a tripod kinematics error - SMC_CP_INVALID_ORIENTATION (Invalid orientation (non-orthonormal matrix or non-unit quaternion, internal error)). MC_ResetGroup does not help. What could be the problem? Has anyone encountered this?
Last updated: 2024-02-05
Post by josephbourgeois on tracking out product
CODESYS Forge
talk
(Post)
Hi everyone! I synchronize the operation of the tripod and the conveyor. I have a problem with the product tracking algorithm on the conveyor (PCS_1). Sometimes I need to stop tracking a product on command without completing the operation. I do this using MC_GroupStop. But when I need to start moving in WCS again (using fb movelinearabsolute), I get a tripod kinematics error - SMC_CP_INVALID_ORIENTATION (Invalid orientation (non-orthonormal matrix or non-unit quaternion, internal error)). MC_ResetGroup does not help. What could be the problem? Has anyone encountered this?
Last updated: 2024-02-05
Post by amy123 on CSV Utility CANNOT_OPEN_DIRECTORY
CODESYS Forge
talk
(Post)
Hello, I tried using the CSV Utility SL Example from the CODESYS IIoT Libraries SL. No matter what path I try, I can not get the InitSave to work from CSVWRitersSTExample, line 2. It always gives the error 'CANNOT_OPEN_DIRECTORY'. I am running this on an Windows Azure VM, with Codesys Control Win V3 x64. I added a folder called 'temp' to my C: so that the default 'C:/temp' would work. However it gives CANNOT_OPEN_DIRECTORY. I tried updating to 'C:\temp' with the same result. Any help would be greatly appreciated!
Last updated: 2024-02-14
Post by androidzz on Json Builder problem?
CODESYS Forge
talk
(Post)
Dear reader, I am using the codesys JSON utilities SL, 1.9.0.0 library. And then specifically the FB JSONBuilder. I need to create a main object with at least 2 objects in it. The first object is no problem, but I cannot insert the second object into the main object. See attached my code and the result I get. I am assuming that I am doing something wrong with the parent index but have tried a lot and can't get it done. Kind regards, Rob
Last updated: 2024-03-11
Post by gregorpl on Tosibox With EATON XV300
CODESYS Forge
talk
(Post)
HEllo, I need to connect with PLC XV300 , the problem is for me not simple. The PLC have remote control by Tosibox VPN tunel. I can see the screen from PLC, but i also want to se Input and Output the PLC . I try to scan the network by useing tosibox Gateway but its not working. Where i should looking the problem ? DO i need added special library ?
Last updated: 2024-03-12
Post by installwhat on raspistepper error after install
CODESYS Forge
talk
(Post)
I've had issues getting the raspistepper installed, all due to errors upon installation. The closest I get is the pictured error. The functions are in the sm3_shared library. I can add this library but that leaves 2 issues. I don't actually know, and I really want to understand this, why the required dependencies haven't been installed correctly. If I add the library it's only available with through the namespace. What can I do to both understand and resolve this? Thanks edit codesys 64 3.5.20.0 - same error on other versions too sm3 raspi stepper 0.0.0.5
Last updated: 2024-04-20
Post by esave on Softmotion Axis Controll
CODESYS Forge
talk
(Post)
Hello everybody I have two of these EtherCat CiA402 stepper driver from Leadshine: https://www.leadshine.com/product-detail/EM3E-556E.html I want to controll them. I already have implemented them in Codesys with Softmotion. I see the position, the velocity and the status word so I can read everything. See picture 1. But when I want to write something like MC_Power or MC_MoveAbsolut with the SM3_Basic library it wont work and with the MC_Reset POU it shows: "SMC_R_DRIVE_DOESNT_ANSWER". See picture 2. Can somebody help me? Thanks a lot esave
Last updated: 2024-05-24
Post by bartg on Open a POU in the editor via scripting
CODESYS Forge
talk
(Post)
Hi, I would like to automate opening some specific pous and visualisations in the codesys environment I found out that I can open it by using : system.commands["42f6acb9-bd6e-42e7-94bb-6e2a03973b83"].execute() But the POU has to be selected in the Devices or POUs navigator. Does anyone know how I can select a specific POU in the navigator? Or how I can open a specific POU? I can retreive the guid of the POU. Thx
Last updated: 2024-05-30
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
CODESYS Forge
talk
(Thread)
Hi, I try to send and receive data using a UDP connection via SysSocket 3.5.17.0. While sending data works fine, I have problems with the receiving part. I am able to capture the received data of client side in wireshark But unable to capture it on the codesys
Last updated: 2024-06-03
Post by tba123 on Script engine, git checkout, Project Environment
CODESYS Forge
talk
(Post)
Hi, I clone a git repository with VersionUpdateFlags.SilentMode, works fine But now I want to checkout a specific commit (with branch_copy command). When using the branch_copy command there is no VersionUpdateFlags and I get this annoying "Project Environment" prompt, blocking further execution of my script without user input. I already tried something like system.prompt_answers[???] = PromptResult.Cancel but I don´t know the string I need here.. The goal is to have a script that clones a repository and compiles every tag + create compiled libraries.
Last updated: 2024-06-10
Post by arcadium on TargetVisu element stacking on top of each other
CODESYS Forge
talk
(Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.