Post by royw on Profinet library for C#
CODESYS Forge
talk
(Post)
Hi, I don't know if I'm in the right place or if it's even possible... I'm looking for a way to address a Profinet device with Record Read and Write from my own PC. I actually only need very few commands to configure our device. This means setting the MAC address and a serial number. We would like to do this from a C# program. Now we are looking for a library or something similar. Since you can do it from Codesys, I thought there might be a DLL or something similar that you could use for this. As I said, we don't want real-time queries of the cyclic data but only record read/write. Does anyone have any helpful hint? Thanks in advance
Last updated: 2023-12-22
Post by aria13 on Has anyone fed ESP32 sensor data into CODESYS (via MQTT/Modbus)?
CODESYS Forge
talk
(Post)
Has anyone tried sending live sensor data from an ESP32 into a CODESYS runtime (for example via MQTT gateway or a Modbus bridge) to trigger PLC logic? I was reading an ESP32 → MQTT tutorial (https://www.theengineeringprojects.com/2021/11/esp32-mqtt.html) that shows how easy it is to publish sensor data from an ESP32, and I’m wondering how practical that is when tying the stream into industrial control software like CODESYS. I’ve also seen Arduino forum threads where people relay sensor streams to MQTT brokers and Raspberry Pi projects that bridge MQTT→Modbus, so I’m mainly curious about real-world issues: reliability, message latency, and simple patterns you’d recommend for safe PLC integration. Any tips, examples, or gotchas from folks who’ve done this?
Last updated: 2025-10-29
Post by hppatrick on Datenkonvertierung für ein SPS-AO-Modul
CODESYS Forge
talk
(Post)
Hi Leute , ich bin neu hier im Forum und habe seit kurzer Zeit mein eigenes SPS-Projekt. Ich stoße hin und wieder an Probleme aber habe diese auf kurz oder lang gelöst. Nun zu meinem Problem: Als Projekt habe ich eine Kühlwassersteuerung , die einen Relativdruck einließst, und anhand desssen Werte dann einen Frequenzumrichter ansteuert. Z. Bsp. 5Bar -> FU auf 70Prozent. Ich lese in Codesys den Analogwert mit der Wago A20_750_455_020 ein. Dieser Wert wird umgerechnet mit LIN_TRAFO in 0-10 (Bar)und und wird dann über einen PID Regler geregelt. (Bibliothek UTIL). Dieser Wert wird dann wieder für die Ausgangskarte Umgerechnet (LIN_TRAFO) . Nun zu meinem Problem : Die Ausgangskarte nimmt nur einen Word Datentyp und meine Bausteine haben den REAL Datentyp. Wenn ich einen Konvertierungsbaustein nehme, Schmeist mir Codesys einen Fehler und das Programm wird geschlossen. Könnt Ihr mir helfen? Vielen Dank im Voraus (Datei habe ich angehängt). Die Ausgangskarte ist eine Wago 750-555-08
Last updated: 2024-06-14
Post by mp9876 on Device logon problem following fresh install
CODESYS Forge
talk
(Post)
All screenshots are enclosed in MS Word document. NOTE; 4 questions features at the end. Any assistance would be greatly appreciated! Hi everyone, I am still having device logon problem following a fresh install Here are the STEPS I went through following a FRESH CODESYS Win 64 3.5.19.60 install on a different computer. ‘Gateway not configured properly’ when attempting to REFRESH from the Users and Groups. Then did Gateway manage and confirmed it was ok: This message popped out as it was a fresh install: YES then: Initially went with Administrator twice (user & password) but it did not like it. No device is responding to …: Continued by setting a new user Pressed OK and obtained the following message: Stopped and Restarted PLC at that point: Obtained the following: Attempted to login a 2nd time without success. Then I scanned the network to see if matching device can be detected: Only way to get it detected was to remove the tick in the ‘Hide non-matching devices…’ Attempted a WINK but got a return like this one: REFRESH either @ Users and Groups or @ Access Rights returns: Then created user ‘mp’ at Project level ang logged in: Understandably device user mp9876 was not valid for the Project. Device information A few questions comes to my mind following these connection attempts: 1- Gateway not configured properly message pops out because of a non-compatible device ? 2- Why would the device not be compatible ? 3- Any way to make the device compatible ? 4- Any ideas on how to get this connectivity problem to the device solved ?
Last updated: 2024-03-17
Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by sebastianrapi on Bibliothek: floatingpointutils
CODESYS Forge
talk
(Post)
Hallo Zusammen, ich versuche die Bibliothek FloatingPointUtils.compiled-library-v3 zu benutzen. leider kommt dabei folgende Fehlermeldung: Kein Quellcode für dieses Objekt... (siehe Anhang) Wie kann ich diese Bib einbinden? Kann ich diese irgendwo herunterladen? Mein Ziel ist es ein DWORD (float) in ein REAL umzuwandeln. ICh hoffe, dass ich dies mit der Funktion HexStrToReal machen kann. So wie hier: https://gregstoll.com/~gregstoll/floattohex/ convert to float... Oder gibt es bei Codesys einen anderen Weg? Ich verwende v3.5 SP20 Patch 1 + (32Bit) Grüße Sebastian
Last updated: 2024-10-17
Post by totorovic on Softmotion not working with simulation mode
CODESYS Forge
talk
(Post)
Good morning, I think that the mode Simulation does not support the Softmotion functionnality because it runs the CODESYS process with normal priority wich is not a good thing for real-time behavior. If you want to test your PLC project, please use a Codesys Control Softmotion (and your computer must have the Ethercat driver installed) or much easier, download your code into the C6 Smart. BR
Last updated: 2024-05-13
Post by mariapaola on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3
CODESYS Forge
talk
(Post)
Hi, Would really appreciate your insights in this issue I have. I am currently using a WAGO 750-881 with multiple IO devices. For one of them I already occupied the MODBUS Master configuration tool so I cannot overwrite it for my other devices. I have a total of two serial interfaces WAGO 750-652. The first one is instantiated in COM2 and doesn't need any protocol since the information comes in an specific formatting that need little code to differentiate between needed info. This one is working just fine. The second one is where I have an issue. I have tried to instantiate the port using MODBUS library modb_L05.lib to properly receive the data from an ARDUINO and I am absolutely unable to open the port: Signal DEVICE2.fbModbus.MODBUS_EXT_MASTER.Interface.Com_Port_Ist_Offen is never TRUE, among with all other signals from that interface, while signal DEVICE1.COM2.Com_Port_Ist_Offen is TRUE, and the other signals also read as TRUE or FALSE. I have tried instantiating the second one as the first one, changing COM3 to COM4, I've tried a lot of things but it wont ever open the channel. I don't know if you have any recommendations for me. For both physical modules, both witness LEDs A and E are on. First one is instantiated like this: PROGRAM DEVICE1 VAR wBaudRate : WORD := BAUD_9600; bDataBits : BYTE := 8; bParity : BYTE := 0; bFlowControl : BYTE := 3; (RS422 FullDuplex with continous send) i : INT; COM2 : SERIAL_INTERFACE; xOpenPort2 : BOOL := TRUE; ( Flag to open the Port ) xInitPort2 : BOOL; ( Flag to initiallize the Port ) ReceiveBuffer2 : typRing_Buffer; END_VAR COM2( bCOM_PORT_NR := 2, cbBAUDRATE := wBaudRate, cbsBYTESIZE := bDataBits, cpPARITY := bParity, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := bFlowControl, utRECEIVE_BUFFER := ReceiveBuffer2, ptSEND_BUFFER := ADR(SendString2), xINIT := xInitPort2, xOPEN_COM_PORT := xOpenPort2, iBYTES_TO_SEND := LEN(SendString2)+1, xSTART_SEND := xSendActive2 ); Second one like this: PROGRAM DEVICE2 VAR COM4 : SERIAL_INTERFACE; xInitPort4 : BOOL := TRUE; xOpenPort4 : BOOL := TRUE; ReceiveBuffer4 : typRing_Buffer; fbModbus : MODBUS_EXTENDED_MASTER_RTU; fbError : enumMB_ERROR; stQuery : typModbusExtendedQuery; stResponse : typModbusResponse; au16Data : ARRAY[0..14] OF WORD; i : INT; tPoll : TON; END_VAR COM4( bCOM_PORT_NR := 4, cbBAUDRATE := BAUD_9600, cbsBYTESIZE := 8, cpPARITY := 0, csSTOPBITS := STOPBITS_1, cfFLOW_CONTROL := 2, ( RS-485 half-duplex ) utRECEIVE_BUFFER := ReceiveBuffer4, xINIT := xInitPort4, xOPEN_COM_PORT := xOpenPort4, xSTART_SEND := xSendActive4, ); stQuery.SlaveAddress := 1; stQuery.FunctionCode := 3; stQuery.Read_StartAddress := 0; stQuery.Read_Quantity := 15; (Poll code) fbModbus( ENABLE := TRUE, bCOM_PORT := 4, ( COM4=> 750-652 port ) cbCOM_BAUDRATE := BAUD_9600, cpCOM_PARITY := 0, csCOM_STOPBITS := 1, cbsCOM_BYTESIZE := 8, cfCOM_FLOW_CONTROL := 2, TimeOut := T#500ms, StartFunction := xStart, ExtQuery := stQuery, Response := stResponse, MB_Error => fbError ); FOR i := 0 TO 14 DO au16Data[i] := stResponse.Data[i]; END_FOR;
Last updated: 2025-11-28
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
CODESYS Forge
talk
(Thread)
How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server
Last updated: 2023-08-28
how to transfer raspberrypi runtime license from sdcard to dongle without the original raspi?
CODESYS Forge
talk
(Thread)
how to transfer raspberrypi runtime license from sdcard to dongle without the original raspi?
Last updated: 2021-04-13
What is the best way to upgrade a project to a new version of Codesys?
CODESYS Forge
talk
(Thread)
What is the best way to upgrade a project to a new version of Codesys?
Last updated: 2022-03-01
I want to use the function of PVT to realize move
CODESYS Forge
talk
(Thread)
I want to use the function of PVT to realize move
Last updated: 2013-05-14
How to intercept a variation in the RetainPerstist variables (for saving to file)
CODESYS Forge
talk
(Thread)
How to intercept a variation in the RetainPerstist variables (for saving to file)
Last updated: 2018-08-03
How to set "Always updatevariables" to "enable 2" by default in DeviceDescription.
CODESYS Forge
talk
(Thread)
How to set "Always updatevariables" to "enable 2" by default in DeviceDescription.
Last updated: 2020-12-10
Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
CODESYS Forge
talk
(Thread)
Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs
Last updated: 2023-10-02
is it possible to connect to a newer runtime from HMI runtime 3.5.16
CODESYS Forge
talk
(Thread)
is it possible to connect to a newer runtime from HMI runtime 3.5.16
Last updated: 2024-07-02
The Ultimate Guide to Taxi Services in the UK: From Airports to City Travels
CODESYS Forge
talk
(Thread)
The Ultimate Guide to Taxi Services in the UK: From Airports to City Travels
Last updated: 2024-08-08
Navigating the UK with Ease: Your Guide to Taxi Services from Major Cities to Key Destinations
CODESYS Forge
talk
(Thread)
Navigating the UK with Ease: Your Guide to Taxi Services from Major Cities to Key Destinations
Last updated: 2024-08-08
how to extract the name of an FB to a variable
CODESYS Forge
talk
(Thread)
how to extract the name of an FB to a variable
Last updated: 2024-10-01
Post by romrot on Trying to connect Codesys OPC server to Ignition
CODESYS Forge
talk
(Post)
Trying to connect Codesys OPC server to Ignition, but I get this fault "java.lang.Exception: no anonymous token policy found"
Last updated: 2025-01-21
Unable to add EL6751 to Control RTE V3 on W11 IoT LTSC using Eng. V3.5 SP21
CODESYS Forge
talk
(Thread)
Unable to add EL6751 to Control RTE V3 on W11 IoT LTSC using Eng. V3.5 SP21
Last updated: 2025-09-08
Can't connect to my raspberry pi 3 after I tried to adjust CODESYScontrol.cfg
CODESYS Forge
talk
(Thread)
Can't connect to my raspberry pi 3 after I tried to adjust CODESYScontrol.cfg
Last updated: 2021-06-17
How to connect Codesys Control win v3 to an ethercat device
CODESYS Forge
talk
(Thread)
How to connect Codesys Control win v3 to an ethercat device
Last updated: 2021-04-26
How to generate PDO explicit request with RTR flag to TRUE
CODESYS Forge
talk
(Thread)
How to generate PDO explicit request with RTR flag to TRUE
Last updated: 2018-06-13