Search talk: command to read device name

 
<< < 1 .. 160 161 162 163 164 .. 189 > >> (Page 162 of 189)

Post by esave on Stepper Drive with Ethercat CODESYS Forge talk (Post)
I bought and installed SoftMotion Light now. When I try to add a SoftMotion Light Axis to my stepper drive and I go online it shows: "The license is missing or invalid". See picture What am I doing wrong? This is the right way right? First add your EtherCat XML-File from your stepper driver and then add the SoftMotion Light axis right? Thanks for your help esave
Last updated: 2024-04-25

Post by eschwellinger on Raspberry PI 5 not working CODESYS Forge talk (Post)
there is a new problem with latest bootloader version. The problem seems to be: Version from2024-04-20 does not work-> 2024-01-15 version works the workaround is a rollback to January version: cp /lib/firmware/raspberrypi/bootloader-2712/stable/pieeprom-2024-01-15.bin ./pieeprom.bin rpi-eeprom-config pieeprom.bin > bootconf.txt rpi-eeprom-config --out pieeprom-new.bin --config bootconf.txt pieeprom.bin sudo rpi-eeprom-update -d -f ./pieeprom-new.bin sudo reboot
Last updated: 2024-04-29

Post by herbasso88 on WebVisu flickering CODESYS Forge talk (Post)
Good morning, I'm new on Codesys Forge, so I'm not sure if this is the right place to talk about my problem. When I open my WebVisu pages with Microsoft Edge, or Chrome, the background and also some rectangles blinking without reason!!! The application is developed with Codesys 3.5.17.10 and run on Codesys HMI, same version (3.5.17.10). After several experiments I discover that the problem happens when I made dynamic the "End of area" property of a meter object, but I can't understand why this blinking problem happens. Also, the problem is only at the WebVisu page, the "normal" VISU pages (the ones opened when Codesys HMI start) work always perfectly. Another strange thing is that the problem happens only if on the same page, where there is the meter object, there is also a trend object!?!? Codesys HMI is running on a Virtual Machine (VMware Workstation 15 player, v.15.5.6) running Windows 10 Pro N 64-bit. The blinking problem happen also if I convert the project to Codesys 3.5.20.0. This version of Codesys and Codesys HMI are installed on a Virtual Machine running Windows Server 2019 Standard 64-bit. In attachment the archive of my project. The attached project has only one page, if "Enable Counter" is not pressed the "End of area" variable of the meter is not updated in the software, and everything work well, normal VISU and WebVisu; if "Enable Counter" is pressed, the "End of area" variable of the meter is updated in the software, and the WebVisu page start blinking. I tried also to enable the "Support client animations and overlay..." property at VisualizationManager, this seems stop the blinking problem, but that property also destroy my WebPage, moving almost all the graphical object, that also seem not working anymore. I really need help to understand what I'm doing wrong, I have to develop a bigger project and I have to understand if trend objects and animated meters cannot stay in the same page. In the final project the WebVisu will be very important because the customer will use this way to access the application to monitor the process. Regards
Last updated: 2024-05-06

Post by yannickasselin on How to sort JSON object in codesys CODESYS Forge talk (Post)
Just adding: sSubscriberdata := ''; Right before your memcopy should fix the extra characters. It is because your are copying 36 characters into a string which can contain more than 36 characters and there is garbage left in the extra characters. Regarding the parsing of json, I usually build a structure that mirrors the json data and use the available methods in the IIoT library to parse the data and fill the structure.
Last updated: 2024-05-08

Post by hjohnson123 on Automatically selecting a visualization element CODESYS Forge talk (Post)
I'm looking to automatically select a text field element in my visualization. I'm not sure if this is possible, as I don't know how to get the data on specific elements. I am wanting automatic selection of the text field, as I am using a keyboard-input barcode scanner, which should always input the barcode into the text field whenever a barcode is scanned. Does anyone know if this can be done?
Last updated: 2024-05-21

Post by schnepper on Minor UI bug: cannot create SFC POU after creating a Function POU CODESYS Forge talk (Post)
After creating a Function POU, it is not possible to then create an SFC POU. Steps to recreate: * Create a new Function POU. SFC is not allowed for Functions, so SFC does not show in the Implementation language dropdown. * Click Add Object -> POU... Function is selected for Type. * Select Program * SFC is not present in the Implementation language dropdown
Last updated: 2024-05-23

Post by plunje on Sensor not set CODESYS Forge talk (Post)
A got a larger project but this very small example makes it clear. I have a button, and after it's clicked a lamp should flip on and stays on, and when the mouse-button is released it should stay on. When I try that in the PLC_PRG it works, but when I change it to a function block (seet attched demo proj) it isn't. I'm fairly new to PLC programming but are very experienced C# engineer, but this goes above my head...
Last updated: 2024-05-26

Post by bartg on Open a POU in the editor via scripting CODESYS Forge talk (Post)
Hi, I would like to automate opening some specific pous and visualisations in the codesys environment I found out that I can open it by using : system.commands["42f6acb9-bd6e-42e7-94bb-6e2a03973b83"].execute() But the POU has to be selected in the Devices or POUs navigator. Does anyone know how I can select a specific POU in the navigator? Or how I can open a specific POU? I can retreive the guid of the POU. Thx
Last updated: 2024-05-30

Post by culius on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Thank you very much for your reply. That helped, it is editable if the library is at root level. Unfortunately, I noticed that I am not using the MQTT client SL, but the AzureMQTTClient from the Azure IoT Hub Client SL library. At first glance, there is no parameter to increase the message size. Does anyone know how to increase this in the library or is it simply not possible here?
Last updated: 2024-06-08

Post by ph0010421 on Windows 11 and SP17 CODESYS Forge talk (Post)
Hello New W11 machine. I've tried installing and the 'Codesys installer' appeared, which basically failed. This was the exe from the Store. I've now tried installing with an old copy of SP17, which didn't try and use the Codesys installer, but has hung at the 'Install all packages added to the setup' stage. Has the exe been updated to use the Codesys installer? What is the installer? Do we think it'll work on w11? thanks, Paul
Last updated: 2024-06-12

Post by rene-h on VU.FbOpenDialog - TargetVisu - 2 x WebVisu CODESYS Forge talk (Post)
Hello, i am trying to find a way how to open Dialogs on a Single Visu. The options from VU.Globals are Target and WebVisu, but Webvisu opens the Dialog on both WebVisus and it should be separated. CurrentVisu can only be used when the Dialog is called from the Visu, but its all done in the Code. One Webvisu is for the User and one is for diagnostic reasons, and they should not be interfered from each other. Maybe someone can help me with this. Thanks
Last updated: 2024-06-13

Post by rabaggett on No Visu on RasPi CODESYS Forge talk (Post)
Hello, I have been having trouble getting a visualization to show up on the RasPi. I have previously used both WAGO touchscreen and Windows ControlWin and had no trouble. The visu does not show on the Raspi screen on start of the program and attempts to view in a browser both on the Raspi (Chromium) and from my laptop (Brave,Chrome,Firefox) running Codesys development fail. The visu shows correctly in Codesys development when online. (Win 11) The control code that is active is operating correctly. Raspi Codesys runtime is licensed. What am I missing? Thanks!
Last updated: 2024-06-20

Post by wollvieh on License Activation Problems CODESYS Forge talk (Post)
on a raspberry pi delete the folder and its content before licensing. /var/opt/codesys/cmactlicense If you plug this SD card in another raspi ( which has another hw-serial number) you'll get a second empty softcontainer. This could lead to an unlicensed PFC (it could only handle one container) The solution is: To delete the /var/opt/codesys/cmactlicense directory and content of it and then aktivate the lizenz via WibuCmRau file and Lizenzmanager.
Last updated: 2024-06-24

Post by rafael on Access to user group IDs CODESYS Forge talk (Post)
Hello, I'm trying to access the group IDs of the connected user. "CurrentUserGroupId" var shows only the first group ID that the user is assigned, I need the other group IDs that the user is in. I find some structs but I can't find where they are used, like "VUM_User" scruct from visuusermgmt, where can I find this vars? https://content.helpme-codesys.com/en/libs/VisuUserMgmt2%20Interfaces/Current/VUM_User.html abyUserGroupIDs seens perfect but I can't find a GVL where it is used.
Last updated: 2024-07-08

Post by mikek10 on Error IoDrvEthernetIP: Connection Failure. (16#1) How to solve CODESYS Forge talk (Post)
Your connection configuration should look something like the attachment. Consuming assembly O->T will be the hex of the assembly you want to reference for output data - I want 102 (DO Data Only) shown in the Wago web page 102 = 16#66. Producing assembly (T->O) is the assembly you require for input data - again shown in the Wago web page - I want 108 (DI Data Only) or 16#6C Then set the number of bytes as per the data in the Wago web page too (both 2 in my case)
Last updated: 2024-07-22

Post by kleeswi on Visualization scaling problem with B&R T30 panel CODESYS Forge talk (Post)
I have found a work around. I have written a python scripts that runs on user login (entry in .bashrc) which overwrites the webvisu.htm and webvisu.cfg.json file with the configuration for the B&R T30 panel (resolution and disable scaling). First I tried to add this setting to the the CODESYSControl.cfg, but that does not work following the big CODESYS Control V3 Manual. [CmpTargetVisu] Application.WindowPositionX=0 Application.WindowPositionY=0 Application.WindowSizeWidth=800 Application.WindowSizeHeight=480
Last updated: 2024-07-30

Post by stuartjr on POU Private variables CODESYS Forge talk (Post)
Pretty sure I know the answer, but thought I would ask just in case. Is there a way to set variables declared in a POU to private so that they can not be accessed from other POUs. I tried using the library pragma, but that just stops the variables being displayed in the selection tree. My compiler version is 2.3.9.62 if that's relevant, and I'm using an ABB AC500 V2 PLC. Cheers
Last updated: 2024-07-31

Post by mase on Python script: Launch Codesys, Execute Script, Exit Codesys CODESYS Forge talk (Post)
Hi, sorry I can´t help you with your issue, but I hope you can give me a hint on getting GUID for other objects than POUs. Your code states "Guid("6f9dac99-8de1-4efc-8465-68ac443b7d08")". We can I find the GUID / ObjectIds`? I wasn´t able to get details about the GUID of DataTypes (STRUCT/ENUM,..)m, Functions (FUN), GLOBALS and TYPES. I want to create markdown of all available project elements. Thanks for your help
Last updated: 2024-08-06

Post by trusty-squire on How to adapt Codesys Control SL to custom board CODESYS Forge talk (Post)
For general usage, these links might help you out. If you are looking at using I2C interfaces, examples from the Raspberry Pi will probably be useful, even if your board isn't a Raspberry Pi. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_rts_serial_com.html https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_raspberry.html If you're developing your own drivers, I can't help you there, although the link you provided will help. If you drill in deeper, the I2C page for example shows function block and method usage, etc. Good luck!
Last updated: 2024-08-09

Post by mubeta on STRUCT AT %MW1000 CODESYS Forge talk (Post)
This is normal and correct since in CoDeSys static addressing of variables uses the IEC method. A LONG tag has the size of 8 bytes, so %ML0 coincides with %MB0 ... %MB7; %ML1000 with %MB8000 ... %MB8007. (Similar reason for word and other formats). Also the reason the compiler won't let you map the structure to a %MW depends on the fact that the individual base elements are manipulated to 64 bits regardless of the smaller size. That said, it makes me strange that you cannot write a parser without making use of static memory allocation.
Last updated: 2024-08-13

Post by carohe on %t SystemTime in Variable CODESYS Forge talk (Post)
Hello, if you enter %t as a "Text" on a rectangle and do not link a variable in "Text variable", it automatically displays the system time. My question is, where do if find a variable, that contains exactly this time? I tried numerous variants using GetLocalDateTime or GetSysTime but I always have to manage timezones myself (which I do not want to do). I only want a variable with the date an time from my windows system, where the visualization is running. Where can I find this variable?
Last updated: 2024-08-20

Post by szotyi on Array of Program CODESYS Forge talk (Post)
Hi! What is the proper and the easiest way to call programs through looping of array of programs, or pointer of program? instead of calling the programs one by one: prog1(inputX: 11); prog2(inputY: 12); prog3(inputZ: 13); similar like: VAR programsToCall : ARRAY [1..3] OF PROGRAM; END_VAR programsToCall[1] := prog1(inputX: 11); programsToCall[2] := prog2(inputY: 12); programsToCall[3] := prog3(inputZ: 13); FOR i := 1 TO 3 DO programsToCall[i] (); END_FOR Thanks.
Last updated: 2024-08-28

Post by paulpotat on cm4 runtime problem CODESYS Forge talk (Post)
It looks like it works with 4.13.0.0 indeed. However when installing the runtime, it's not possible to select the multicore option (see attachment). But once the 4.13.0.0 runtime is installed, the logs seems to indicate that the runtime is running in multicore mode. Looking at "htop" output, it seems like it actually is running on multiple CPU. This is very misleading, is it normal or is this a bug ? Thank you for your answer @eschwellinger, BR
Last updated: 2024-09-02

Post by joep on overruling kinematic limits of [-90°, 90°] in bipod_rotary CODESYS Forge talk (Post)
Hi All, for my robotics application we are building a 2-axis parallel scara using the kin_bipod_rotary kinematics. Codesys implemented limits of [-90°, 90°] according to the documentation: https://content.helpme-codesys.com/en/libs/SM3_Transformation/Current/SM3_Transformation/Function-Blocks/Positioning-Kinematics/Parallel-Systems/Kin_Bipod_Rotary.html Would it be possible to overrule these limits somehow, our mechanical limits are more in the range of [-110°, 135°] In this range we also don't encounter point where singularity is an issue. Hopeful someone knows a solution, Best regards, Joep
Last updated: 2024-09-04

Post by alex-at-xana on EThercat Dynamic configuration CODESYS Forge talk (Post)
Ah - forgot another question as it may be related to the PLL problem: I am executing a 4ms cycle. I do not call (from what I know) the Ethercat_MAster periodically in my program. The bus cycle task is set to the Ethercat task. I would assume that the master should send 250 frames per second. Yet, the status of the master says it transmits 500 frames per second which would indicate that the master is called twice. Any ideas there?
Last updated: 2024-09-10

<< < 1 .. 160 161 162 163 164 .. 189 > >> (Page 162 of 189)

Showing results of 4715