Post by e13740e on Parameterized Property syntax for array element processing
CODESYS Forge
talk
(Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT // One or more index parameters are declared here <index_name> : <index_type>; END_VAR</index_type></index_name></data_type></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY
Last updated: 2025-10-09
Post by vahasa on CAN TPDO / RPDO
CODESYS Forge
talk
(Post)
Hi I'm automation engineering student and I'm not yet quite familiar with CAN-bus. What I am trying to achieve, to send two byte message via CAN from Epec display to Scott Drive inverter. I'm using code template made with Epec Multitool in Codesys 3.5 Problem i'm facing is that drive responds with same COB-ID. In multitool, you can create TPDO/RPDO. And depending on that, display either sends or only receives. This is problem, because for parameter polling from drive, you need to send two byte request to 0x399 and drive responds with eight bytes. If request is longer, drive don't respond. 0x399 is currently setted as RPDO, so display doesn't send anything on startup and I made program that sends messages to 0x399 bytes 0 and 1 and bytes 3-7 are shown in display. If setted as TPDO, display send all eight bytes and therefor drive cannot respond. But, I think because they are defined as RPDO, display won't send message, although monitoring with Codesys, values are changed. Question is, how should COB-ID be configured in Codesys, so it wouldn't automatically start to send message but would send when needed?
Last updated: 2023-12-19
Post by manuknecht on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hello all I am using an AxisGroup with the Gantry2 Kinematics to move a 2D-Gantry system. When creating the AxisGroup, the SoftMotion_PlanningTask is created automatically with a cycle time of 2 ms in my case. I realized that the maximum cycle time of this task can spike to very high values (up to 60 ms) at lower speeds of the motion, leading to synchronization issues and errors on the axes. The same behaviour - though not as drastic - can be observed with virtual axes too. Is this behaviour intended or to be expected? Can the cycle time or type of the SoftMotion_PlanningTask be changed to prevent these errors? Or is there another fix for this issue? I tried changing the cycle type to Freewheeling, which solved the synchronization issues, but caused an error on the AxisGroup after a while, reading SMC_CP_QUEUE_UNDERRUN. Thanks in advance and best regards Manuel
Last updated: 2024-03-07
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by rjwkerkhof on IIot Libraries SL --> Web Socket Client SL Pong issue
CODESYS Forge
talk
(Post)
Dear all, I am developing a Web Socket Client in Codesys 3.5 using the Web Socket Client SL library to retrieve data from a third party. Connecting and reading works fine however after 40 seconds the connection gets interrupted by the server due to keepalive ping timeout. After discussion with third party it seems that the Web Socket Client SL library replys to the Ping request of the Web Socket server BUT does not add the "Application data" = 4 bytes in the body of the Pingframe to the Pongframe. Therefor the server does not recognize the Pongframe send by the Web Socket Client SL library and automatically disconnects. Is this a known issue with the libary or am I doing something wrong? Is there a workaround to add the 4 bytes manually to the Pongframe before replying it to the server? Thanks in advance, Roy
Last updated: 2024-04-09
Post by jrsantab on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
We have finally solved the problem. The version of the Gateway in the computer that worked (3.5.11.0) and the one that didn't (3.5.17.30) was different. We have three different Codesys 3.5 versions installed because we work with different controllers. I believe that, depending on the sequence you follow to install the versions you get a different Gateway version. To solve the problem you first have to disable the "obsolete" services. Open services, serach for (in our case) CODESYS Gateway V3 Version 3.5.11.0 CODESYS ServiceControl Version 3.5.11.0 I stopped the services and changed to Manual Start. Then you have to create the new services. In our case, from a Command Prompt session (cmd): SC CREATE "Codesys GatewayService Rigual" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\GatewayService.exe" and then SC CREATE "CODESYS ServiceControl Version 3.5.17.30" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\CODESYSControlService.exe" remember also to set them as Automatic Start!
Last updated: 2024-04-22
Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog
CODESYS Forge
talk
(Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05
Post by mxj262 on FB having single input but initialized with Array
CODESYS Forge
talk
(Post)
I am adding elements of an ARRAY using pointer to access each element inside a FOR loop and the FOR loop does not stop! What is the right way to use pointers in such case?? I have another loop that is not using pointer and it stops but the loop using pointer keep on adding. METHOD FB_Init: BOOL VAR_INPUT bInitRetains: BOOL; // TRUE: the retain variables are initialized (reset warm / reset cold) bInCopyCode: BOOL; // TRUE: the instance will be copied to the copy code afterward (online change) END_VAR VAR_IN_OUT // basically REFERENCE TO window_buffer: ARRAY [*] OF INT; // array of any size END_VAR THIS^.windowPtr := ADR(window_buffer[0]); THIS^.windowSize := UPPER_BOUND(window_buffer, 1) - LOWER_BOUND(window_buffer, 1) + 1; FUNCTION_BLOCK FB500 VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR windowPtr: POINTER TO INT; windowSize: DINT; currentIndex: UINT; element1:INT; element2:INT; i:INT; j:INT; sum:DINT:=0; END_VAR element1:=windowPtr[0]; // read the first element of the Array dynamic memorry element2:=windowPtr[1]; FOR i:=0 TO (TO_INT(windowSize-1)) BY 1 DO // this loop does not stop Sum:=sum + windowPtr[i]; END_FOR FOR j:=0 TO 5 BY 1 DO // this loop stops j:=j+1; END_FOR https://ibb.co/k3DhkZT
Last updated: 2024-05-06
Post by cmj-icsys on Custom configure tab in device editor
CODESYS Forge
talk
(Post)
Hi everyone, I’m developing a custom CODESYS I/O driver for my company’s device, and I’ve been studying the example projects in CODESYS V3.5 SP20 Patch 5. In the IOMappingExample.project, I noticed that EtherCAT devices provide additional configuration tabs in the Device Editor, such as General, Process Data, etc. However, for custom I/O driver examples (based on IoDrv), the Device Editor only shows the default tabs like <devicename> I/O Mapping or <devicename> Parameters.</devicename></devicename> I’d like to create custom tabs or configuration pages in the Device Editor (e.g., “General Settings”, “Communication”, etc.) to allow users to configure parameters in a more structured way. Could anyone explain: How to define and register custom tabs or UI pages in the Device Editor? What tools or SDKs are needed to create UI elements such as combo boxes or check boxes? How to bind those UI controls to device parameters defined in the XML (device description)? Any example, SDK reference, or documentation link would be really helpful. Thanks in advance!
Last updated: 2025-10-20
Post by manuknecht on XY Chart causes extremely long cycle in Visu Task
CODESYS Forge
talk
(Post)
I am using the visualization element "Cartesian XY Chart" in a visualization template within a library to display recorded position values. I managed to configure the chart as desired and it displays the values like it should. A problem occurs when clicking on the chart to move the cursor, zoom or pan. Upon clicking the visualization element for the first time, the task in which the visualization is run spikes to a cycle time of around 5'000 to 15'000 ms (the configured cycle time is 100 ms). Sometimes this even completely crashes the web-visualization. After this very long cycle, the visu task normalizes again and the chart can be interacted with as usual. Another spike in cycle time occurs once the visualization is switched to a frame that does not contain the chart. I did reduce the data array to only a few values and tried changing the update behaviour of the chart, but it did not change the problems I am facing. Did anyone experience a similar issue or even has a solution for this?
Last updated: 2026-06-16
Post by taywinkel on Virtual Keyboard Support on Login Page
CODESYS Forge
talk
(Post)
I am in the process of getting a visualization to work with the codesys keyboard. I created a custom keyboard which works fantastic for all input fields in the main visualization. I created a user management for my runtime, which gave me the standard blue login page. The codesys keyboard does not show up when trying to enter the usernam or password. I have tried every setting: changing the keyboard back to the standard codesys keyboard, and changing various settings on the visualization manager with no success. I can only use a physical keyboard connected to the device to enter the password. I did try removing the keyboard to no success either. I even tried creating my own login page so I could guarantee the keyboard showed up. This ended in disaster as I could not figure out the very complicated VisuUserManagement and VisuUserManagementDialog library, and documentation is contradictory or lacking. I imagine that an on screen keyboard is essential for many people's projects when using touchscreen panels, so I am wondering what others are doing. I would rather not use an external virtual keyboard (external to codesys) because this causes its own complications (I am working on a linux build with high securities).
Last updated: 2026-03-22
Post by lukasz on Unresolved reference when trying to upload to Codesys Runtime V3
CODESYS Forge
talk
(Post)
Hello! I'm working with Codesys SP21 Patch 4. The project builds without any errors. When trying to upload my project to Codesys Runtime V3 x64 I get a lot of Unresolved Reference errors, all with FU- at the start and then -CLOSELAYER2, -GETBUSINFO, -GETFRAME etc. I also get a error pop-up that I should 'update device' in the project but it's not specified to which version or anything useful really.There's also not much to choose from. When I check Runtime version in the systray I get 3.5.21.40 and it's the same as I have set up in the project as the device. All information I get is that it should be clear from the errors but no useful information is provided in the errors. Do I need to install some library? I checked other posts and for different reference error and this was the answer. Thanks in advance!
Last updated: 2026-03-25
Post by sushela on TEMU COUPON CODE [[acq615756]] get $100 Off + 30% Discount
CODESYS Forge
talk
(Post)
Temu offers an exclusive deal for both new and existing users in Georgia. With the coupon code ([acq615756]), you can enjoy a $300 discount on a wide range of products, whether it's your first order or you've been shopping on Temu for a while. This offer ensures substantial savings for everyone, making Temu a top choice for affordable online shopping. Temu is offering an attractive $100 off coupon code, [acq615756], exclusively for first-time users. This promotion allows new customers to save significantly on their initial purchase, making it an excellent opportunity to explore Temu's extensive product range. Additionally, this code can be combined with an extra 30% discount on select items, further enhancing savings. To redeem the offer, simply create an account, add items to your cart, and enter the coupon code at checkout to enjoy your discount. How to Redeem: Create or log into your Temu account: If you’re new to Temu, sign up; if not, just log in. Browse the products: Add your preferred items to the cart. Apply the code ([acq615756]): During checkout, enter the code to receive a $300 discount. Benefits of Using the Code: Savings on all categories: The $300 discount applies to many categories, from electronics to fashion. No minimum spend: This coupon is ideal as it doesn’t require a minimum purchase amount. Applicable for new and existing users: Unlike most promotions, this one works for both first-time and repeat customers. To get the most out of your shopping experience, download the Temu app and apply our Temu coupon codes for existing users at checkout [[acq615756] or [acq615756]]. Check out these five fantastic Temu coupons for existing users: [acq615756]: New users can get up to 80% extra off. [acq615756]: Get a massive $100 OFF your first order! [acq615756]: Get 20% off on your first order; no minimum spending required. [acq615756]: Take an extra 15% off your first order on top of existing discounts. [acq615756]: Temu UK users can enjoy a $300 discount on your entire first purchase. In the world of online shopping, Temu has become a go-to destination for affordable and quality goods across a wide range of categories, from fashion to electronics. One of the most attractive features of Temu is its frequent offering of discount codes and coupons, allowing shoppers to save even more on their purchases. Among these, the Temu coupon code $100 OFF is particularly enticing, offering substantial savings for savvy shoppers. This article will explore everything you need to know about using this coupon code, including specific region-based codes for Estonia and the USA. using this code will give you a flat $100 OFF and a $300 discount on your Temu shopping. Our Temu coupon code is completely safe and incredibly easy to use so that you can shop confidently. Check out these five fantastic Temu coupon codes for August and September 2024: [acq615756]: Enjoy flat $100 OFF on your first Temu order. [acq615756]: Download the Temu app and get an additional $100 OFF. [acq615756]: Celebrate spring with up to 90% discount on selected items. [acq615756]: Enjoy 90% off on clearance items. [acq615756]: Beat the heat with hot summer savings of up to 90% off. [acq615756]: Temu UK Coupon Code – $100 OFF on appliances at Temu. These Temu coupons are valid for both new and existing customers, so everyone can take advantage of these incredible deals. What is the Temu Coupon Code $100 OFF? The Temu coupon code $100 OFF is a special promotional offer that provides customers with a significant discount on their purchases. Typically, this coupon can be applied at checkout, reducing the total purchase price by $300, provided certain conditions are met. These conditions often include minimum purchase requirements, product category restrictions, or regional limitations. This coupon is highly sought after by frequent shoppers looking to make large purchases or those seeking a great deal on high-ticket items. Temu's existing customer coupon codes are designed just for new customers, offering the biggest discounts and the best deals currently available on Temu. To maximize your savings, download the Temu app apply our new user coupon during checkout. How to Use Temu Coupon Code $100 OFF Using a coupon code on Temu is simple. Follow these steps to unlock your discount: Select Your Items: Add the products you want to buy to your shopping cart. Make sure they meet any requirements, such as minimum purchase amounts or specific categories. Enter the Coupon Code: At checkout, look for the “Coupon Code” or “Promo Code” field. Enter the applicable coupon code for your region or offer. Apply and Save: Click the “Apply” button, and the $300 discount should be deducted from your total. Double-check that the coupon has been successfully applied before finalizing your purchase. Complete Your Purchase: Once the coupon has been applied, proceed with the payment and enjoy your savings. Temu Coupon Code $100 OFF for Estonia [[acq615756]] For shoppers in Estonia, the Temu coupon code $100 OFF can be accessed using the code [[acq615756]]. This code is specifically tailored for Estonian customers and provides a considerable discount on purchases. How to Use the Estonia Coupon Code: Add your chosen items to your cart, ensuring that they meet any minimum purchase requirements. At checkout, enter [[acq615756]] in the coupon field. Click “Apply” to receive the $300 discount. Complete your purchase with the discount applied. Estonian shoppers can use this code to significantly reduce the cost of their orders, making Temu a fantastic option for those looking for deals on everyday essentials or big-ticket items. Temu Coupon Code $100 OFF for USA [[acq615756]] For customers in the USA, the Temu coupon code $100 OFF is available through the code [[acq615756]]. This region-specific code allows US-based customers to enjoy the same level of savings on their orders, giving them access to high-quality products at unbeatable prices. How to Use the USA Coupon Code: Add your desired products to the shopping cart, ensuring the total meets the coupon’s minimum purchase threshold. At checkout, input [[acq615756]] in the designated coupon field. Hit “Apply,” and the $300 discount will be reflected in your order total. Proceed to finalize the transaction with the discount. US shoppers can take advantage of this coupon code to enjoy substantial savings on a wide variety of products, from clothing and home goods to electronics and beauty items. Verified Temu Coupon Codes for August and September 2024 Temu coupon code $100 OFF — ([acq615756]) $100 OFF Temu Coupon code — ([acq615756]) $100 OFF Temu coupon code — ([acq615756]) Flat $100 OFF Temu exclusive code — ([acq615756]) Temu 90% Discount Code — ([acq615756]) Temu $100 OFF coupon code — ([acq615756]) Benefits of Using Temu Coupon Codes There are several benefits to using Temu coupon codes, especially high-value ones like the $100 OFF promotion: Save on Big Purchases: These high-value coupon codes are ideal for larger purchases, significantly reducing your total out-of-pocket costs. Access to Quality Goods at Lower Prices: Temu offers a wide range of products across different categories, and coupon codes help make these products even more affordable. Easy to Use: Applying a coupon code is straightforward and user-friendly, allowing shoppers to quickly enjoy discounts without any hassle. Exclusive Region-Based Offers: As seen with the Estonia and USA codes, Temu offers region-specific deals, allowing shoppers in different parts of the world to enjoy tailored savings. Important Considerations When Using Temu Coupon Codes Before using any coupon code, including the Temu coupon code $100 OFF [[acq615756] or [acq615756]], keep in mind the following: Expiration Dates: Always check the validity of the coupon code. Most codes have expiration dates, and expired codes will not work. Minimum Purchase Requirements: Many high-value coupons require a minimum purchase amount to qualify for the discount. Ensure your cart total meets this requirement before attempting to apply the code. Product or Category Exclusions: Some coupon codes may only apply to specific product categories or may exclude certain items, such as sale items or special collections. One-Time Use: Many promo codes, especially high-value ones like $100 OFF, are often limited to one-time use per customer. Be sure to use them wisely. Temu coupon code 2024 for existing customers reddit [[acq615756]] Temu coupon code 2024 for existing customers usa [[acq615756]] Temu coupon code 2024 for existing customers free shipping [[acq615756]] Temu coupon code 2024 for existing customers first order [[acq615756]] Temu coupon for existing customers [[acq615756]] Temu coupon code 2024 for existing customers September [[acq615756]] Temu coupon code 40 off [[acq615756]] Temu coupon $100 OFF for existing customers [[acq615756]] Temu coupon code 40 off first time user [acq615756] Temu coupon code 40 off free shipping [acq615756] Temu existing user coupon code 2024 [acq615756] Temu 10% off code [acq615756] Temu coupon wheel [acq615756] 50 Off Temu [acq615756] Code Temu [acq615756] Free Temu codes [acq615756] Temu coupons for returning customers [acq615756] Temu coupons - [acq615756] Temu coupon code first order reddit [acq615756] Temu coupon code first order free shipping [acq615756] Temu coupon code 2024 for existing customers [acq615756] Temu coupon codes for existing users [acq615756] Temu coupon code 40 off [acq615756] Temu coupon $100 OFF [acq615756] Free Temu codes [acq615756] Final Thoughts The Temu coupon code $100 OFF [[acq615756] or [acq615756]] is a fantastic opportunity for shoppers to make significant savings on their purchases. Whether you’re shopping from Estonia or the USA, offers substantial discounts that can help you get more value for your money. By taking advantage of these promo codes, you can shop confidently, knowing you’re unlocking the best possible deals on the items you love. be sure to check the terms and conditions associated with each coupon code, and happy shopping!
Last updated: 2024-10-26
Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start
CODESYS Forge
talk
(Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14
Post by fmon on Modbus TCP client reconnection problem
CODESYS Forge
talk
(Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED". Is it normal ? It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus client reconnection. What is different at the first client connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-17
Post by westcountryewe on ac_persistence not working when creating a Boot Application but works with a Direct Download to the PLC
CODESYS Forge
talk
(Post)
I am using V3.5 SP18 Patch 5. I have noticed that when I Create a Boot Application from CODESYS, and upload this to my PLC via a USB stick the AC_Persistence does not work and none of my values that are in my PersistenceChannel are retained. However, if I connect direct to my PLC and I perform a direct download of my CODESYS program, my values that are in my PersistenceChannel are retained and work as they should. This makes me wonder if there are files that are missing when a Boot Application is created. I have tried taking a backup of my configuration files after performing a direct download, which gives me the plclog.zip folder, and appears to have the ac_persistence folder present within the file structure, however when I replace the plclogic.zip with the same folder that was created when I created a Boot Application, it still does not work but I wonder whether this is because the ac_persistence folder isn't stored in the correct location for reading. The .app and .crc files are embedded within the plclogic.zip folder, which obviously when uploading need to be standalone files in the root directory of the USB, so the intention there is clearly to extract the .app and .crc files and put them into the correct location within the USB. I wonder if it could be the same for the ac_persistence folder? I have tried moving it to different locations but none have worked. Has anybody else discovered a fix for this? I know the short-term solution is to do a direct download to the PLC but there are some logistical reasons why this isn't neccesarily the best solution for us.
Last updated: 2024-02-27
Post by wold on CodeMeter Network Server: Keep runtime dongle local-only and export only a second CmStick
CODESYS Forge
talk
(Post)
Hello, I am running a CODESYS Control Runtime on a Raspberry Pi. Two CmSticks are connected to the same system: CmStick A - Runtime license - MultiCore license - KNX license CmStick B - Engineering / Developer licenses My goal is: The runtime on the Raspberry Pi shall use CmStick A locally. Licenses from CmStick A shall NOT be provided by the CodeMeter Network Server. Only licenses from CmStick B shall be available to remote network clients. During troubleshooting I observed that the CodeMeter Network Server collects licenses from both CmSticks. The KNX license appears to be local-only, but the runtime and multicore licenses of the same dongle are still visible through the server. I would like to know if a supported configuration exists for the following scenario: One CmStick remains strictly local to the runtime. A second CmStick on the same machine is exported through the CodeMeter Network Server. Questions: Is it possible to exclude a specific CmStick from being exported by the CodeMeter Network Server? Can this be configured via License Access Permissions (ACL), WebAdmin, or another mechanism? Can export rules be applied per CmStick, per Firm Code, or per Product Code? If supported, could you provide a configuration example or a reference to the relevant documentation? The reason for asking is that after removing a separately installed CodeMeter server component and returning to a local-only setup, the runtime licensing behaviour became stable again. Therefore I am looking for the officially supported way to keep the runtime dongle local while still providing engineering licenses from a second dongle over the network. Thank you.
Last updated: 2026-08-02
Post by olehmann03 on PFC200 - WAGO 750-8202 - MODBUS RTU
CODESYS Forge
talk
(Post)
Hello, I’m working on implementing Modbus RTU communication with a Carel controller (CPCO). I want to use the front RS485 interface through the DB9 connector. The issue is that I can’t get the communication working correctly. Below are the steps I’ve done so far: Connected pins 3 and 8 from the DB9 connector to the +/- RX/TX terminals on the Carel side. In the PLC shell, I set serialmode to RS485. In WBM under Administration > Serial Interface > Assign owner of serial interface, I set the port to unassigned. In the device tree, I created Modbus_COM with the following settings: COM port: 1 Baud rate: 19200 Parity: None Stop bits: 1 Created a Modbus client on this COM interface in RTU mode. Under the status tab, I can see it is in running state. On the client, I created a Modbus server and set the Modbus address of my unit to 1. Defined a few channels as FC03 to read holding registers according to the Carel register map. I checked the communication with the Carel controller using a USB-to-RS485 converter connected to my PC, and communication works correctly there. In the status tab, I can see that the Modbus server is polling, but there is no response from the controller. I also tried multiple times swapping A/B lines on the Carel side, but it did not help. Do you have any suggestions on what else I should check?
Last updated: 2026-05-22
Post by olehmann03 on PFC200 - WAGO 750-8202 - MODBUS RTU
CODESYS Forge
talk
(Post)
Hello, I’m working on implementing Modbus RTU communication with a Carel controller (CPCO). I want to use the front RS485 interface through the DB9 connector. The issue is that I can’t get the communication working correctly. Below are the steps I’ve done so far: Connected pins 3 and 8 from the DB9 connector to the +/- RX/TX terminals on the Carel side. In the PLC shell, I set serialmode to RS485. In WBM under Administration > Serial Interface > Assign owner of serial interface, I set the port to unassigned. In the device tree, I created Modbus_COM with the following settings: COM port: 1 Baud rate: 19200 Parity: None Stop bits: 1 Created a Modbus client on this COM interface in RTU mode. Under the status tab, I can see it is in running state. On the client, I created a Modbus server and set the Modbus address of my unit to 1. Defined a few channels as FC03 to read holding registers according to the Carel register map. I checked the communication with the Carel controller using a USB-to-RS485 converter connected to my PC, and communication works correctly there. In the status tab, I can see that the Modbus server is polling, but there is no response from the controller. I also tried multiple times swapping A/B lines on the Carel side, but it did not help. Do you have any suggestions on what else I should check?
Last updated: 2026-05-22
Post by baltzer on ICertificateVerifier.VerifyCertificate doesn't appear to override an ERR_CERT_HAS_EXPIRED rejection in TCP_Client.Upgrade()
CODESYS Forge
talk
(Post)
Setup: Net Base Services (NBS), TCP_Client + TLSContext, ePurpose := CLIENT_SIDE, connecting to a third-party embedded device (Velux KLF200 home automation gateway) whose factory-installed TLS certificate expired on 2026-07-12 and has no user-facing renewal path. Tested on both CODESYS Control for Raspberry Pi SL (3.5.19.0) and CODESYS Control Win V3 x64, with identical results on both. Goal: Accept the peer's expired certificate via a custom ICertificateVerifier implementation, since the certificate itself can never be replaced. Implementation: FUNCTION_BLOCK FB_MyCertVerifier IMPLEMENTS NBS.ICertificateVerifier VAR udiCallCount : UDINT; aeCurStateLog : ARRAY[0..9] OF NBS.RTS_IEC_RESULT; END_VAR METHOD VerifyCertificate : UDINT VAR_INPUT hCert : NBS.RTS_IEC_HANDLE; eCurState : NBS.RTS_IEC_RESULT; END_VAR IF udiCallCount < 10 THEN aeCurStateLog[udiCallCount] := eCurState; END_IF udiCallCount := udiCallCount + 1; VerifyCertificate := 0; // also tried: VerifyCertificate := eCurState; Wired in via tlsContext.itfCertVerifer := certVerifier at declaration time, alongside itfTLSContext := tlsContext set at TCP_Client's own declaration (per an earlier forum thread here on ensuring inline start-values on FB-typed variables are actually honored when nested one level deep - that fix was needed and worked correctly for getting the handshake to start at all). Observed: - VerifyCertificate is confirmed called exactly once per connection attempt (via the call counter above). - eCurState passed in = 0x709 = ERR_CERT_HAS_EXPIRED - correctly reflecting the actual state of the peer's certificate. - Packet capture confirms the full TLS 1.2 handshake completes correctly at the wire level: ClientHello -> ServerHello -> Certificate -> ServerKeyExchange -> ServerHelloDone -> our ClientKeyExchange/ChangeCipherSpec/Finished -> server's ChangeCipherSpec/Finished. Both sides successfully complete the cryptographic handshake. - Despite this, TCP_Client.Upgrade() subsequently returns NBS.ERROR.CONNECTION_ERROR, and the connection is torn down with a plain TCP FIN (not a TLS alert) roughly 7-8ms after our side ACKs the server's Finished message. - TCP_Client.eErrorID (inherited from LCon) remains NO_ERROR throughout - the failure is only visible via Upgrade()'s return value. - Returning 0 (ERR_OK/ERR_CERT_OK - confirmed via the CmpErrors2 Interfaces documentation that these are literally the same value) makes no difference. - Echoing eCurState back unchanged (on the theory that this callback might work like mbedTLS's native verify callback, where the incoming state is a flags value to be cleared/modified and returned, rather than paired with a separate fixed "accept" sentinel) also makes no difference. - Identical result across udiVerificationMode := 0, 1, and 2. - Importing the peer's certificate into the runtime's trusted certificate store via cert-import trusted makes no difference either. - With itfCertVerifer left at its default (no custom verifier) and udiVerificationMode := 2, the underlying engine sends its own fatal TLS alert (handshake_failure) immediately after receiving the peer's Certificate message - suggesting built-in validation may reject at the record layer independent of whether a custom verifier is even present. Questions: 1. Is there an additional step required for a custom ICertificateVerifier to actually override an ERR_CERT_HAS_EXPIRED (or more generally, any ERR_CERT_*) rejection, or is certificate validation enforced unconditionally for a CLIENT_SIDE TLSContext regardless of what the verifier returns? 2. Is 0/ERR_OK genuinely the correct "accept" return value for VerifyCertificate, or does it expect something else (a specific bit pattern, a different constant, a value that must be computed from hCert itself)? 3. Is there a supported way to connect to a peer presenting a certificate that is both self-signed and expired, short of the peer issuing a new certificate? Happy to share the full packet captures or additional test combinations if useful. Also worth noting for anyone finding this thread later: a maintained Node-RED library for this same device (node-red-contrib-velux-klf200, forked to handle this exact expired-certificate situation) solves it by disabling built-in TLS validation entirely (rejectUnauthorized: false) and doing fingerprint-based pinning by hand after the handshake completes, rather than relying on a validation callback - which may be the more realistic approach here too if ICertificateVerifier genuinely can't override this class of rejection. Thanks in advance /Jørgen Disclosure: most of the CODESYS code and this investigation was developed with the help of Claude (Anthropic's AI assistant) - the state machine design, SLIP/checksum implementation, and debugging methodology (including the packet capture analysis) were worked through in an extended back-and-forth with it. Posting here because we've run out of self-serviceable options and this now looks like it needs input from someone with visibility into NBS's actual implementation.
Last updated: 2026-07-26
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
For those who will step on this thread. Everything is fine, I had only to increase by 1 my place holders number. For sure the system is occupying the number 1 without being declared ... Below the modification I made to get my code working. [SysFile] PlaceholderFilePath.2=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.3=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.4=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.5=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by vformanek on No source code available for profinet library
CODESYS Forge
talk
(Post)
Hello, I have been using CODESYS for a while and after updating to version 3.5.18.50 the code randomly stops with this fault. Why is that ? I have tried to locate the fault in the Call Stack but I dont know what to do now... I have updated the projects properly for the version I am using. This fault started happening after like 14 days of using the new version of CODESYS.
Last updated: 2023-08-23
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello, Exulting the command /opt/CoDeSysControl/Files/run restart debug I get this response from the linux terminal:(ScreenShot1 to ScreenShot7) When I try to reconnect via codesys this line appears at the linux terminal level:(ScreenShot8) A few seconds later, the error window appears on Codesys.(ScreenShot9) I see that following the command /opt/CoDeSysControl/Files/run restart debug there are errors, are they the problem? Sincerely,
Last updated: 2023-08-24
Post by ellcap on Symbol Configuration, I'm doing it wrong
CODESYS Forge
talk
(Post)
if you're here because you are making the same mistake as me, I just resolved it. I mistakenly thought I didn't need to write the word attribute in the column labeled attribute. changed this 'symbol' := 'read' to this attribute 'symbol' := 'read' The last two in this clip are still wrong: I recongize this is probably a big "duh". That's ok. I like to fail out loud in hopes it helps someone else from looking silly.
Last updated: 2023-08-31
Post by janderson on Ethercat scan for devices not picking up EL7041 as a softmotion axis
CODESYS Forge
talk
(Post)
it appears that the different revisions have different PDOs. I am currently trying to use the rev25. I have tried to use the rev24 (the device repository entry not from 'scan for devices') and i keep getting 'invalid output mapping' or 'invalid input mapping' in the ethercat log. I cant even get the bus to run from the device description that comes from 'scan for devices'...
Last updated: 2023-09-18