Post by m83coding on Raspberry Pi Codesys SPI Master
CODESYS Forge
talk
(Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26
Post by amy123 on Any guides on using Codesys containers in Docker?
CODESYS Forge
talk
(Post)
I had an issue aswell, I was trying to use docker and got stuck on the specific line ' Downloading https://download.microsoft.com/download/9/5/A/95A9616B-7A37-4AF6-BC36-D6EA96C8DAAE/dotNetFx40_Full_x86_x64.exe' within install2.sh - which is actually from the https://raw.githubusercontent.com/Winetricks/winetricks/master/src/winetricks, winetricks_selfupdate(). Would love to know if anyone has a known solution. Only other thing I can think is to download winetricks +.net, update the winetricks to point to the downloaded .net? Granted Im not too savy with Docker so I have been struggling on figuring that part out- would love any suggestions!
Last updated: 2024-05-19
Post by stewnguth on New License not working.
CODESYS Forge
talk
(Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23
Post by viksym on Get text from textlist
CODESYS Forge
talk
(Post)
Does anybody know how to get a specific text from a text list within a program. Obviously it works in a visualization, but because I will have an HMI that has it's own system and I will have to send variables to this HMI via an OPC UA connection, I need to be able to get a text into a string. I tried using the VisuElems like this, but it only returns an empty "" and nothing else. IF trig THEN sText := VisuElems.cmpDynamictext.DynamicTextGetDefaultText(ADR(sTextList), ADR(sAlarmID))^; //sText := VisuElems.cmpDynamictext.DynamicTextGetText(ADR(sTextList), ADR(sAlarmID))^; trig := FALSE; END_IF Any help and idea is highly appreciated because I am getting desperate here.
Last updated: 2024-05-31
Post by mborchert on PFC100 Error "Bus not running"
CODESYS Forge
talk
(Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17
Post by rohan on Child Application Alarm
CODESYS Forge
talk
(Post)
Hi All, I'm trying to develop a multi-application project that allows me to switch between applications. I currently have a parent application and several child applications, as this is the only way for them to share CAN/Ethernet communication. I've noticed that I am only able to create an Alarm Configuration for the parent application. But the children application do not seem to be displaying alarms on the Alarm Table in the visualisation for when an alarm is raised. Does anyone know of a fix, solution or a way around this? I am utilising Codesys v3.5 SP16 Patch 5 64Bit
Last updated: 2024-06-21
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27
Post by artem1223 on Synaxis of library declarations in the ST
CODESYS Forge
talk
(Post)
Codesys 3.5 17.30, plc - crevis GN-9373. I need to use RTC of pls for write in registers (need to check difference of writen 100 and 200 registers). For this i try to use SysTimeRtc (SysTimeRtc.SysTimeRtcGet) but its not working. After it i tryed to use SysTimeGetMs and something like this but still not working. Library? Mb but check project, SysTime with SysTimeRtc already, all what i know - already is here. Its my first try to learn ST (early used fbd and ladder, yeah), pls help with it. Mb problem with a syntaxis, but im not sure.
Last updated: 2025-11-26
Post by timvh on Version management
CODESYS Forge
talk
(Post)
This depends on what you want to achieve with installing the latest version and how you manage your projects and repositories. Maybe you also want to update your device (right click on it to update) or maybe your device is depending on certain versions of libraries (go to the library manager in your project and download the missing libraries). An option is also to first create a projectarchive of the current project you have before you install a new version of CODESYS. Then you can open this projectarchive in the new CODESYS version. Especially if you install the latest version of CODESYS in a Sandbox.
Last updated: 2025-12-15
Post by eschwellinger on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21
CODESYS Forge
talk
(Post)
yes, this is a known issue which will be fixed with 3.5.23.0 .. soll will take some time. You need to switch back the runtime running not as dedicated user, like it was before 4.21.0.0 How to switch back you'll find here. ('Change service user' in the deploy tool) https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_dedicated_user.html to sumerize both problems: 1. missing entries in CODESYSControl_Usr.cfg was the problem on Raspberry PI Runtime 2. Arm64 SL is running rootless by default since 4.21.0.0 ( Pi not by default you need to switch manually if needed due this GPIO restriction)
Last updated: 2026-07-22
Post by ranadheer on Assistance for MQTT configure with external broker (Mosquitto)
CODESYS Forge
talk
(Post)
Hi everyone Am trying to make establish MQTT connection , where am using IIOT example for this as a demo mode. where i had given IP-address of of local Linux application as a 172.31.239.67 and port number as 1883 in the PLC_PRG itself, and preparing the publish message by manually as " this is from published message", and this should receive at the subscriber side. Aim: To make communicate external publisher to the CODESYS by using MQTT protocol. By any chance having reference documents about this implementation please share here. and suggest the process to make it possible. I had uploaded reference project file after updating address in th PLG_PRG, kindly assist to configure with the broker
Last updated: 2025-12-03
Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program?
CODESYS Forge
talk
(Post)
Still looking for a solution. I have gathered more information that might help: Device: ABB AC500 PM556-TP-ETH Firmware version: 2.4.2.14993 (dated 2014) Open ports confirmed: 502 (Modbus TCP), 1200 and 1201 (CODESYS runtime). SSH (22) and HTTP (80) are not reachable. No SD card in the PLC. I can connect via Automation Builder using the current IP and Online Login works, but I have no original source project available. Automation Builder requires a full PLC download to apply IP changes, which we want to avoid as it would overwrite the running program. Any guidance on how to change the IP without a full download would be greatly appreciated. I am also open to solutions using third party tools, DCP protocol, or scripts. Thank you
Last updated: 2026-05-22
Post by timvh on EXCEPTION [watchdog] how to find position cause
CODESYS Forge
talk
(Post)
Monitor what your current cycle time is (in the Task Configuration when you are online). If this is sometimes close to 200ms, then change your code (e.g. limit the loops, or prevent copying a lot of data between objects). Or just set the Watchdog time (or sensitivity) higher if you don't care that it sometimes takes longer than 200ms. If you want to find out which objects in your application consume the most time, then buy a PDE (Professional Developer Edition) license. With this you get a license for the Profiler. This can help you a lot to find the root cause, because it will create a nice overview of all objects, their calls and the time (percentage) it takes to execute it.
Last updated: 2026-02-09
Post by dat422 on CODESYS crashes when adding standard OPC UA Information Model to Communication Manager
CODESYS Forge
talk
(Post)
Hi all, I am experiencing a problem when trying to add a standard OPC UA Information Model to the Communication Manager. When I try to add the following standard information models to a new or existing project http://opcfoundation.org/UA (15.07.2020) http://opcfoundation.org/UA/DI (02.06.2020) CODESYS crashes every time during the process. Adding an OPC UA Server itself works without any problem. The crash only happens when adding the standard OPC UA Information Model. CODESYS version: CODESYS V3.5 SP20 Patch 4 (64 bit) Has anyone experienced the same issue or knows a possible workaround? Thank you in advance.
Last updated: 2026-03-19
Post by vstrom on Codesys v3.5.22.10 - Fail to create a project Archive
CODESYS Forge
talk
(Post)
Hi to all, I've created a project using the File->New Project-> Standard Project command. Then I've add the object "Visualization Manager" and then tried to create a project archive (File->Project Archive->Save Archive), but it fails with the error "Access to the path 'C:\Program Files\CODESYS 3.5.22.10\CODESYS\Common\3hxi4iod.put' is denied". The idicated file don't exist. First time of use of the new Codesys versionù, I've reinstalled the developement software but nothing change. If I don't add the Visualization part, the archive is created, it's seems to be a problem with the HMI part. Any ideas? Thanks
Last updated: 2026-04-22
Post by williamcorlin on The future and proper use of CAA.BOLT, CAA.SEMA,..
CODESYS Forge
talk
(Post)
I've been moving in the same direction. For new libraries, I'm trying to minimize dependencies on APIs that look like they're being phased out unless the documentation explicitly recommends them. For synchronization primitives like CAA.BOLT and CAA.SEMA, I'd love to see an official replacement or abstraction layer that's guaranteed to remain stable across runtimes. That would make library development much cleaner than relying on platform-specific SysLib* implementations or conditional compilation everywhere. Until there's clearer guidance, my approach has been to isolate the locking mechanism behind a small wrapper interface. If CODESYS changes the recommended API in the future, only that wrapper needs to be updated instead of every library that uses it. It isn't perfect, but it's made maintenance much easier. https://forge.codesys.com/forge/talk/Engineering/thread/e6c20a740e/ https://zapgames.io/
Last updated: 2026-07-14
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Hello everyone, I have a very simple program for the process, but it's driving me crazy and I can't see the problems I'm left with: Short topological description: Dual Core Berghof controller with softmotion runtime version 3.5.19.30; Two axes with servodrive on canopen bus, clocked distributed from master; Ethercat I/O node; 2 ms ethercat task, 2 ms canopen bus cycle time; I/O objects of the canopen master and canopen drives connected to the ethercat task cycle; Problem 1: Two separate programs each manage their own axis and drive, with separate state machines. A first axis moves primarily in velocity, except having to position itself absolutely at a predetermined point at the end of the job; the second axis, on the other hand, is a paper unwinder that changes, for each job cycle, from actions in absolute, relative, and cam displacement with the master axis. Well, the state machine of both axes was written in such a way as to call running the useful FB and change it on state change in this way: CASE i_stateMachine OF 0: o_Power(Enable := TRUE, bRegulatorOn := FALSE, bDriveStart := FALSE, Axis := o_PaperUnwinderAxis); o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_MoveRel(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_CamSelect(Execute := FALSE, Master := o_MachineAxis, Slave := o_PaperUnwinderAxis, CamTable := cam_PaperUnwinder); o_CamIn(Execute := FALSE, Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Execute := FALSE, Slave := o_PaperUnwinderAxis); o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis); IF ... THEN i_StateMachine := 10; END_IF; 10: o_Power( Enable := TRUE, bRegulatorOn := TRUE, bDriveStart := TRUE, Axis := o_PaperUnwinderAxis ); IF o_Power.Status THEN i_StateMachine := 20; END_IF; 20: (* Avanzamento carta *) o_MoveAbs( Execute := TRUE, Position := o_Somewhere, Velocity := 25.0, Acceleration := 3666.7, Deceleration := 3666.7, Jerk := 48000.0, Direction := MC_DIRECTION.positive, Axis := o_PaperUnwinderAxis ); IF o_MoveAbs.Done THEN o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); i_StateMachine := 30; END_IF 30: d_HomingPosition := ...; o_SetPosition( Execute := TRUE, Position := d_HomingPosition, Mode := FALSE, Axis := o_PaperUnwinderAxis ); (* ... *) IF o_SetPosition.Done = TRUE THEN o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis ); o_LogServer.Append(sMessage := '...', lscClass := LOGSERVER_CLASS.ALWAYS, sdt := o_CommonsMgrData.systime.sdtLocal); i_StateMachine := 40; END_IF; 50: ... The code above is a sketchy example of what I wanted to write. But it gives me a spot problem: in some, the state change results in a drive error, which is unrecoverable except with a reinitialization via SM3_ReinitDrive(). Things are improved a little if in the program I always run the call of all softmotion blocks in this way: o_Power(Axis := o_PaperUnwinderAxis); o_Jog(Axis := o_PaperUnwinderAxis); o_Halt(Axis := o_PaperUnwinderAxis); o_MoveAbs(Axis := o_PaperUnwinderAxis); o_MoveRel(Axis := o_PaperUnwinderAxis); o_CamIn(Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Slave := o_PaperUnwinderAxis); If I don't execute all the calls of all the motion FBs used, when exchanging machine state often (but not always), the axis goes into error with event id THE_FB_WASNT_CALL... Done a little diagnostics it seems that the FBs return the bDone, before they are completely terminated. I tried doing the machine state exchange not with the bDone bit of the FBs, but with the 'standstill' state of the axis. It didn't seem to change anything. Problem 2: During the use SM3_ReinitDrive() I get the erro in the log: "NetID 0: SDO read error for object 16#607C..." Assuming that the device involved it's one of the two servodrive, (no others device are present in the network), I don't found any object 0x607C in the 'possible object list in/out' of the two drive, and I don't understand where this object can be listed. So any ideas and suggestions regarding these two issues will be very, very welcome. If you need the source project, I am willing to send it.
Last updated: 2024-07-17
Post by artplc on 3.5 P20 hangs - no response
CODESYS Forge
talk
(Post)
Subject: Solution: CODESYS Freezes Linked to Large Symbol Configuration (OPC UA) Hello everyone, I was experiencing the same problem as many here: CODESYS (v3.5 SP20+) freezing during compilation and download, especially on projects that use OPC UA for SCADA. The only workaround was to run Build > Clean all before every download. I believe I have found the root cause and a permanent solution. The Problem: The issue is directly related to a large Symbol Configuration. In my project, I only need about 700 tags for OPC UA, but the Symbol Configuration list was showing over 250,000 tags. This is because it automatically includes all variables from Global Variable Lists (GVLs) and other memory areas. When any static variable is changed, the IDE tries to rebuild this enormous list, causing it to freeze for several minutes. The Solution: Instead of letting CODESYS export every variable by default, you can use a pragma to tell it which variables or GVLs to exclude from the symbol export process. Place the following pragma at the top of any GVL or data structure that you do not want to be part of the symbol configuration: 1 {attribute 'symbol' := 'none'} 2 VAR_GLOBAL 3 // All variables in this GVL will now be excluded from the 4 // Symbol Configuration by default. 5 InternalVariable1 : INT; 6 InternalVariable2 : BOOL; 7 END_VAR After adding this pragma to all the GVLs that were not needed for OPC UA, the number of tags in my Symbol Configuration dropped to the correct amount. The compilation and download process is now fast again, with no freezing. This method is much more efficient than manually managing the symbol list in the editor. I hope this helps others who are facing this frustrating issue. Best regards.
Last updated: 2025-08-10
Post by gilbert-mh on CAA net base TCP client cause PLC to crash - Kernel message : N0HZ_local_softirq_pending 80
CODESYS Forge
talk
(Post)
Hello all, I have been trying to implement a TCP client on a Festo PLC (CPX-E-CEC-M1) and it looks like it works well except that after some time (greatly varies between a few hours to more than 100h) my PLC crash. When I look into the log file the only thing I see is that before the crash happens a few kernel warnings : N0HZ_local_softirq_pending 80 and then the crash. I've looked into this warning and from what I could find on the net it seems that this is warning is triggered when the ethernet link is down. I've tried to correct this bug for quite some time and what I know is that : - The crash is caused by my TCP client, when I remove it from my code I see no crash - The crash happens more quickly the more the TCP client is used. - The time before the crash is not directly proportional to the number of communications or their size. But it looks like it is just more likely to happen if the client connect to the server at a higher frequency. - The precedent observation makes it seem unlikely that the crash is caused by some memory overflow because then the crash speed would be more proportional to the amount of data exchanged. SO from these observations, I believe that the crash could be caused by the PLC trying to connect to a server while there is some kind of issue with the ethernet link resulting in the PLC getting stuck in some indefinite state and making it crash. This still seems a bit unlikely to me because if the ethernet is down it simply shouldn't be able to contact the server and the communication would just fail which doesn't cause my PLC to crash. Has anyone encountered the same kind of problem (with the same kernel message) ? I am pretty sure the warning is not the direct cause of the crash but just an indicator that something is wrong with my PLC. Thanks in advance
Last updated: 2024-01-12
Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
CODESYS Forge
talk
(Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol in codesys, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25
Post by pppn on Issue with Forward Open Connections in Ethernet/IP Protocol Stack in Codesys
CODESYS Forge
talk
(Post)
Hello, I am facing an issue with my Ethernet-based project in Codesys. My product was functioning well until I modified the protocol stack and uploaded it to my device. Here are the details of my problem: Project Setup: I am working on an Ethernet-based project to test my product. The project was running without issues before modifying the protocol stack. Issue: After modifying the protocol stack and uploading it to my device, I am encountering an error in Codesys related to the forward open connections. Error status: connection failure, extended: connection in use or duplicate forward open. According to the Ethernet/IP protocol, there are three forward open connections that need to be established. The first two connections are opening without any issues. The third connection, which is an input-only connection, is causing problems. The error message indicates that the connection is already open. Debugging Attempts: I have extensively debugged the protocol stack and found no issues. The product works well when tested with EIP tools but not with Codesys. Exclusive owner connections are working correctly, and only the input-only connection is problematic. Wireshark Traces: Wireshark traces show that the third connection attempts to open but reports that it is already open. Steps to Reproduce: Modify the protocol stack and upload it to the device. Attempt to establish three forward open connections in Codesys. Observe the error on the third connection (input-only). Request: I would appreciate any suggestions or guidance on how to resolve this issue. If there are specific settings or configurations in Codesys that I need to check, please let me know. Additionally, if there are known issues or workarounds related to this problem, I would be grateful for the information. Attachments: Wireshark traces showing the connection attempts and errors Screenshots of the error messages in Codesys codesys version: CODESYS V3.5 SP16 Patch 3 + 64 bit
Last updated: 2024-06-25