Search talk: word to bytes

 
<< < 1 .. 164 165 166 167 168 > >> (Page 166 of 168)

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by salvadegianluca on List files in a directory with SysDiropen And SysDirRead CODESYS Forge talk (Post)
Good morning; I'm facing an issue that seems being caused by the library itself. I'm trying to create the list of all the files that are stored inside a psecific directory. Unluckily the first file is allways hidden. VAR CONSTANT arysEmptyArray:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING := [(iArrayMAXDimension - iArrayMinDimension)('')]; iArrayMinDimension:INT := 1; iArrayMAXDimension:INT := 99; END_VAR VAR_INPUT sDirectoryToInspect:STRING; sSearchFilter:STRING; END_VAR VAR_IN_OUT xCheckFileInsideDirectory:BOOL; END_VAR VAR arysListOfFoundFiles:ARRAY[iArrayMinDimension..iArrayMAXDimension] OF STRING; sNullString:STRING; iNullIndex:INT := 0; libInfoAboutThePath:DirInfo; libResultOfThePathMonitoring:CmpErrors.RTS_IEC_RESULT; libInstanceToMonitorThePath:CmpErrors.RTS_IEC_HANDLE; sEntityToSearch:STRING; dMaxEntityDimension:DINT := SIZEOF(sEntityToSearch); libFileInfo:DirInfo; sFilteredFileName:STRING; iIndexToScrollArrays:INT; END_VAR IF xCheckFileInsideDirectory THEN arysListOfFoundFiles:=arysEmptyArray; iIndexToScrollArrays:=iArrayMinDimension; libInstanceToMonitorThePath:= SysDirOpen(szDir:= sDirectoryToInspect,szDirEntry:=sNullString,diMaxDirEntry:= iNullIndex,pDirInfo:= ADR(libInfoAboutThePath),pResult:= ADR(libResultOfThePathMonitoring)); WHILE libResultOfThePathMonitoring = Errors.ERR_OK AND iIndexToScrollArrays <= iArrayMAXDimension DO sEntityToSearch:= ''; libResultOfThePathMonitoring:=SysDirRead(hDir:=libInstanceToMonitorThePath,szDirEntry:=sEntityToSearch,diMaxDirEntry:=dMaxEntityDimension,pDirInfo:=ADR(libFileInfo)); sFilteredFileName:= FUN_06_00_FindItemInString_0(sFilter:=sSearchFilter,sSource:=sEntityToSearch); IF sFilteredFileName <> '' THEN arysListOfFoundFiles[iIndexToScrollArrays]:=sFilteredFileName; iIndexToScrollArrays:=iIndexToScrollArrays + 1; END_IF IF libResultOfThePathMonitoring <> Errors.ERR_OK THEN libResultOfThePathMonitoring:= Errors.ERR_OK; END_IF END_WHILE libResultOfThePathMonitoring:=SysDirClose(hDir:= libInstanceToMonitorThePath); xCheckFileInsideDirectory:=FALSE; END_IF How is possible to solve this issue? Any known work around?
Last updated: 2024-09-17

Post by andrax on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
Hi, Communication with the ADS1115 is actually simple. 1. write config 2. write address pointer 3. read conversation register The ADS1115 works like a multiplexer. This means that you do this individually for each channel that you want to read. e.g: Channel 1: write config > write address pointer > read conversation register Channel 2: write config > write address pointer > read conversation register Channel 3: write config > write address pointer > read conversation register Channel 4: write config > write address pointer > read conversation register then you start again from the beginning You can also omit individual channels or read only one. It doesn't matter. I have written the driver so that I can also use it on the TCA9548. The driver is from Stefan Dreyer. In your case, the driver works and communication with the ADS1115 is running. As you can see, the cfgWrong:=FALSE If you could not write or read data, cfgWrong:=TRUE; This means that either something is wrong with your ADS1115 or you have connected something incorrectly. Question: what voltage do you want to measure?
Last updated: 2024-11-08

Post by s1ack on Request a dark mode for CODESYS CODESYS Forge talk (Post)
and other colors have to be licensed? Introducing Code-Based Licensing Code Basic S: White text w/ grey background (ST only) Code Basic M: White text w/ dark gray background (ST Only) Code Basic L: White test w/ black background (ST Only) Code Standard S: 2 Colors of light syntax highlight colors w/ black background. (ST Only) Code Standard M: 4 Colors of light syntax highlight colors w/ black background. (ST only) Code Standard L: 6 Colors of light syntax highlight colors w/ black background. (ST only) Code Performance S: 2 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance M: 4 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) Code Performance L: 6 Colors of light syntax highlight colors w/ user definable background. (Entire IDE) You get the gist... I used to be a big fan of CoDeSys. Recent re-entry after 5 years away, not so much.
Last updated: 2 hours ago

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20

Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5) CODESYS Forge talk (Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02

Post by frank1001 on Codesys läuft nicht hoch CODESYS Forge talk (Post)
Bin Neuling bei Codesys. Habe Codesys 64 Bit installiert (3.5.1) Nach dem Starten geht nur ein EIngabefenster auf mit folgenden Inhalt. Weiter passiert nichts. Was kann ich machen ? //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// _/_/_/_/ _/_/_/_/ _/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/ _/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/_/_/_/_/ _/_/ _/_/ _/_/_/_/_/_/ _/_/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/ _/_/_/_/_/ // // // // // //// //// //// //// /////// // // // // // // // // // // ///// ////// ////// ////// ////// ////// // ////// /// //// //// ///// ////// ///// // ///// _/ //////////////////////////////////////////////////////////// //////////////////////////////////////////////////////////// 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>CmpMemGC</cmp>, <id>0x0000001f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuBreakpoints</cmp>, <id>0x00000305</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysCrypto</cmp>, <id>0x00000141</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysFileStream</cmp>, <id>0x00000120</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysGraphicGDIPlus</cmp>, <id>0x0000012a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInt</cmp>, <id>0x00000106</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeCommonControls</cmp>, <id>0x00000138</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysNativeControl</cmp>, <id>0x0000012f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPci</cmp>, <id>0x0000010c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysPort</cmp>, <id>0x0000010d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindow</cmp>, <id>0x00000117</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System: <cmp>SysWindowFileDialog</cmp>, <id>0x0000011a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysTargetSoftMotion</cmp>, <id>0x00000112</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysCpuMultiCore</cmp>, <id>0x0000013d</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= System|Dynamic: <cmp>SysReadWriteLock</cmp>, <id>0x0000013e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpAuditLog</cmp>, <id>0x000000a1</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvCom</cmp>, <id>0x00000006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvShm</cmp>, <id>0x00000068</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvC</cmp>, <id>0x00000066</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpIpc</cmp>, <id>0x0000001d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor</cmp>, <id>0x00000014</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpObjectMgr</cmp>, <id>0x00000080</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSercos3Master</cmp>, <id>0x0000004c</id> <ver>3.1.2.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.19.20</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpSupervisor</cmp>, <id>0x0000008f</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuClientControllerHost</cmp>, <id>0x00000132</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= <cmp>CmpXMLParser</cmp>, <id>0x00000058</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpTargetVisuStub</cmp>, <id>0x00000053</id> <ver>3.5.19.0</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.025Z: Cmp=CM, Class=1, Error=0, Info=10, pszInfo= Dynamic: <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.19.10</ver> 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= MultiCore support: [activated], all cores are used 2023-09-19T08:02:04.045Z: Cmp=SysCpuMultiCore, Class=1, Error=0, Info=4, pszInfo= Number of available cores: 8 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.1.167</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 0</interface> at router <instance>0</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpBlkDrvUdp, Class=1, Error=0, Info=6, pszInfo= Network interface: <ipaddress>192.168.56.1</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-19T08:02:04.076Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>ether 3</interface> at router <instance>1</instance> registered 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=2, pszInfo= Running as network server 2023-09-19T08:02:04.076Z: Cmp=CmpChannelMgr, Class=1, Error=0, Info=1, pszInfo= Running as network client 2023-09-19T08:02:04.077Z: Cmp=CmpChannelServer, Class=1, Error=0, Info=0, pszInfo= <numofchannels>4</numofchannels> channels available, each of the size <buffersize>100000</buffersize> Bytes 2023-09-19T08:02:04.265Z: Cmp=CmpRedundancy, Class=1, Error=0, Info=0, pszInfo= Debug Messages not activated 2023-09-19T08:02:04.266Z: Cmp=CmpRedundancyConnectionIP, Class=1, Error=0, Info=0, pszInfo= Read connection settings... 2023-09-19T08:02:05.456Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvShm</interface> at router <instance>2</instance> registered 2023-09-19T08:02:05.456Z: Cmp=CmpBlkDrvShm, Class=1, Error=0, Info=9, pszInfo= Local address (BlkDrvShm) set to 1 2023-09-19T08:02:05.463Z: Cmp=CmpBlkDrvTcp, Class=1, Error=0, Info=6, pszInfo= Local network address: <ipaddress>192.168.56.1</ipaddress> 2023-09-19T08:02:05.464Z: Cmp=CmpRouter, Class=1, Error=0, Info=4, pszInfo= Network interface <interface>BlkDrvTcp</interface> at router <instance>3</instance> registered 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= No certificate for the OPC UA server available. 2023-09-19T08:02:05.507Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Security policy allows plain text communication. Secure communication is deactivated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ********** 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= OPC UA Server Started: 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Hostname: SIEMENS, Port: 4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= URL: opc.tcp://SIEMENS:4840 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Loopbackadapter activated. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= All available networkadapters are used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Multithreading activated. 7 workers used. 2023-09-19T08:02:05.508Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= ************ 2023-09-19T08:02:05.513Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'CODESYS_DefaultProvider' (version 0x3051300) registered at the OPC UA server. 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= CODESYS SoftMotion Win V3 x64 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=4, pszInfo= OS=Windows, CPU=x86, Arch=64Bit, Coding=C 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=6, pszInfo= <version>3.5.19.20</version> <builddate>Aug 1 2023</builddate> 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=5, pszInfo= Copyright CODESYS Development GmbH 2023-09-19T08:02:05.522Z: Cmp=CM, Class=1, Error=0, Info=0, pszInfo= ========================================================================= 2023-09-19T08:02:05.529Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AddressSpaceFragment Provider' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'OPC UA for IEC-61131-3' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.530Z: Cmp=CmpOPCUAServer, Class=1, Error=0, Info=0, pszInfo= Provider 'AlarmManager' (version 0x3051314) registered at the OPC UA server. 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>0</instance> address to (00a7) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>1</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>2</instance> address to (0001) 2023-09-19T08:02:05.606Z: Cmp=CmpRouter, Class=1, Error=0, Info=1, pszInfo= Setting router <instance>3</instance> address to (2ddc:c0a8:3801) 2023-09-19T08:02:05.611Z: Cmp=CM, Class=1, Error=0, Info=34, pszInfo= CODESYS Control ready 2023-09-19T08:02:05.796Z: Cmp=CM, Class=2, Error=0, Info=0, pszInfo=!!!! no runtime license - running in demo mode(~2 hours)
Last updated: 2023-09-19

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Here is the output Codesyscontrol.log ;**************************************************************** ;<loggername>/tmp/codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>1000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;**************************************************************** 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <logoptions> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <bEnable>1</bEnable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <type>normal</type> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <timestamp>rtc</timestamp> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <Filter>0x0000000f</Filter> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxEntries>1000</MaxEntries> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFiles>1</MaxFiles> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFileSize>1000000</MaxFileSize> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, </logoptions> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, CODESYS Control for PFC200 SL 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 6, <version>3.5.16.40</version> <builddate>Mar 2 2021</builddate> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 5, Copyright (c) 3S - Smart Software Solutions GmbH 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKbus</cmp>, <id>0x0000008a</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPfcx00</cmp>, <id>0x00000088</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.16.0</ver> 2023-09-12T21:12:16Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>192.168.1.17</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 4</interface> at router <instance>0</instance> registered 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 2, Running as network server 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 1, Running as network client 2023-09-12T21:12:16Z, 0x0000000a, 1, 0, 0, <NumOfChannels>4</NumOfChannels> channels available, each of the size <BufferSize>100000</BufferSize> Bytes 2023-09-12T21:12:16Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2023-09-12T21:12:16Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2023-09-12T21:12:16Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>192.168.1.17</ipaddress> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>2</instance> registered 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Hostname: PFC200, Port: 4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, URL: opc.tcp://PFC200:4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CODESYS_DefaultProvider with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CmpOPCUAProviderIecVarAccess with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:17Z, 0x00000126, 1, 0, 0, Valid license found for OPC UA IecVarAccess provider. 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 7, Retains matched to bootproject of application [<app>Application</app>] 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 6, Bootproject of application [<app>Application</app>] loaded 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to <address>(0011)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 16, 8, Network interface for mainnet=<mainnet>ether 5</mainnet> not found 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to <address>(0000)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>2</instance> address to <address>(2ddc:c0a8:0111)</address> 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 10, Application [<app>Application</app>] started 2023-09-12T21:12:17Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2023-09-12T21:13:37Z, 0x00000001, 1, 0, 0, runtime licensed 2023-09-12T21:17:17Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Channel timeout (<curtime>16012264</curtime>, <lasttime>15982259</lasttime>) 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Closing connection to <address>0329:032e</address> 2023-09-23T14:46:00Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-23T14:48:57Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange]
Last updated: 2023-09-27

Post by ellcap on Did a library update and now can't open project CODESYS Forge talk (Post)
EDIT: Title was a mistake. Should say now I can't compile / download project. Codesys V3.5SP19 Patch 2. Updated the libraries/packages using the Codesys Installer. I'm hit with this error ------ Build started: Application: ------- Typify code... [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0086: No definition found for interface 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): IecVarAccess: C0077: Unknown type: 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): Initialize [IecVarAccess]: C0032: Cannot convert type 'IECVARACCESS(iecvaraccess, 4.4.0.0 (system))' to type 'IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0231: Expression of type 'BOOL' expected in this place [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0077: Unknown type: 'ITFID_IIecVarAccess17' [ERROR] iecvaraccess, 4.4.0.0 (system): QueryInterface [IecVarAccess]: C0046: Identifier 'ITFID_IIecVarAccess17' not defined Compile complete -- 6 errors, 101 warnings Build complete -- 6 errors, 101 warnings : No download possible
Last updated: 2023-09-25

Post by matthew on New Ladder Editor Issues CODESYS Forge talk (Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10

Post by smartcoco on The text list provided outside the library is not available for visualization controls within the library. CODESYS Forge talk (Post)
I have a project called 'DemoProject' and a library called 'DemoLib'. Create a visual control named "DemoVisu" in the library, with a selection box of type "ComboBoxInteger" in the space. Now 'ComboBoxInteger' requires a 'Text list'. This "Text list" is provided when I call the "DemoVisu" control of the "DemoLib" library in "DemoProject". And this text list is in 'DemoProject'. I found that 'ComboBoxInteger' no longer works at this time. Other visual controls that use text lists also have this issue. I hope there is a good solution to this problem.
Last updated: 2023-10-16

Post by grant32 on Codesys ARTI .XML file not creating but working. CODESYS Forge talk (Post)
Hello, I am working on a project with a Beijer Nexto Xpress. I have done this a few times with no issues but for some reason this time when creating a Symbol Configuration the ARTI .xml file is not being created in the Project Folder. However when manually putting the ARTI tags in the HMI program they are connected and work. So I am just not getting the file to import all the tags. I can do it manually which is fine but no matter where the project folder is saved this occurs. Anyone experienced this? Did not see another forum on it.
Last updated: 2023-10-27

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools → Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
I'm getting closer to the error. The combination of STRUCT and ARRAY probably causes the strange behavior. As soon as the ARRAY is followed by a variable, the problem arises. Examples: X: ARRAY[1..2] OF INT; // okay Y: ARRAY[1..2] OF STRUCT; // problem Z: STRUCT; Z.ArrayOfInt[1]; // okay Z.ArrayOfStruct[1].Variable // problem // *update - array of array also causes the error A: ARRAY[1..2] OF ARRAY[1..4] OF BOOL; // problem I can't be the only one who has this problem. Or? Maybe there is a solution. Anyone? Or is it a bug after all?
Last updated: 2023-11-17

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by mark on IO link on IFM AL133x only single digital input on a channel CODESYS Forge talk (Post)
I have a problem with the CODESYS IO-Link SL software. When I insert a IO link master AL1332 and plug a discrete digital input to a channel it reads only 1 of the 2 available inputs on that channel. Is there anyone who sorted out if the second input is also usable? When we configure the module without the CODESYS IO-Link SL software then the second input on the channel can be used. At the moment we use some channels on a module as IO-link port, and some as discrete IO. It would be very nice if we can use both inputs on a channel with the use of CODESYS IO-Link SL.
Last updated: 2023-12-18

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by vformanek on irq-set piority is not working in plc-shell CODESYS Forge talk (Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05

Post by yang123 on EtherCAT Can't reconnect to servo drive CODESYS Forge talk (Post)
I am using Ethercat Master 4.6.0.0 and have use the automatic restart slaves feature. But we found of after the Ethercat communication normal and slave drive power-off and power-on the slave can't reconnect sucess. The PLC Log show the drive was al status "6#34 : Invalid DC Timeout Error" and its was reconnection sucess first but seconced later the drive will show the "16#2C : Fatal Sync error" and then drive will can't reconnection. Other slave are reconnect sucess which was link after the can't reconnect's drive the drive was OMRON R88D-1SN
Last updated: 2024-01-23

Post by mondinmr on Shared Memory Access Issues CODESYS Forge talk (Post)
In Windows I need create shared memory in PC software and connect from CODESYS. If shm is not GLOBAL doesn't work due different users between runtime and PC software. PC software need admin privileges. Name need "Global\\" before key. Very unsafe!!! If CODESYS create shared I cannot find key PC side. In Linux I can create shared memory as standard user, bind in the runtime docker, use keys without any "Global\\". Much more safe!!! If CODESYS create shared you need play with permissions to use app as standard user. I prefer create form PC software as standard user.
Last updated: 2024-01-30

Post by karol-abktech on Raspberry and problem with runtime CODESYS Forge talk (Post)
Hi, My problem is with raspberry pi 4 with 2 GB ram,. Install codesys is correct but runtime works only few seconds or I can connect with device few seconds. I can ping raspberry and in system info I can see " !!!! Warning: no runtime license - running in demo mode(~2 hours)" but it is 2 minutes after runtime. When I press Start runtime I have another few seconds when I can connect to raspberry. After this time I couldn't find device. Of course, reapet start runtime works every time on few second. Raspberry is new and works with fresh install raspberry os 32 bit. Where should I start looking for solve of my problem ?
Last updated: 2024-02-14

Post by valenting on Runtime not working on raspberry pi Bullseye CODESYS Forge talk (Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01

<< < 1 .. 164 165 166 167 168 > >> (Page 166 of 168)

Showing results of 4194