Post by grepoo on DataSource CodesysApp V3
CODESYS Forge
talk
(Post)
Hi, trying to create a datasource in appV3 but it returns error code 259 (not nearer specified) everytime, no matter the device i am using. Any idea of what it might signify ?
Last updated: 2025-11-19
Post by seler on Custom button with output status
CODESYS Forge
talk
(Post)
I did some work around by adding IN switch on top of OUT bulb picture(SwitchImage) and setting IN switch button to invisible but this is not quite elegant. How to combine it to one visu element?
Last updated: 2025-11-20
Post by patrik on Wish: CODESYSControl.cfg - again
CODESYS Forge
talk
(Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21
Post by rossanoparis on Clarifications regarding the appropriate runtime system to use
CODESYS Forge
talk
(Post)
Hallo all I would appreciate some clarifications regarding the appropriate runtime system to use. I've been using 'KUNBUS CPUs' and 'CODESYS Control for Raspberry Pi MC SL' for the last 4 years. Recently, there have been some changes in the CODESYS licensing policy. [ https://store.codesys.com/en/howto_applicationbasedlicenses ] My questions are mainly two: 1) If I need to start a new project using 'KUNBUS CPUs', which is the correct runtime system to use. 2) Old projects built using 'CODESYS Control for Raspberry Pi MC SL' should be updated to another RT system? Current RT systems ... a)CODESYS Control for Raspberry Pi MC SL b)CODESYS Control for Linux ARM SL c)CODESYS Virtual Control SL May I count on receiving an explanation to understand the differences among the runtime systems listed above? A detailed and well-organized answer would be greatly appreciated. Kind regards Rossano
Last updated: 2024-09-23
Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"?
CODESYS Forge
talk
(Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19
Post by aseitzinger on CODESYS Control for Linux SL on virtual machine?
CODESYS Forge
talk
(Post)
Hello, there in different information available regarding the possibility to run CODESYS Control for Linux SL on a virtual machine. https://forge.codesys.com/trg/linux-sl/home/Home/ says CODESYS Control for Linux SL is a runtime system, which can run on any Debian based X86 PC, VM or Cloud container... https://store.codesys.com/media/n98_media_assets/files/2302000005/3/CODESYS%20Control%20for%20Linux%20SL_de.pdf says CODESYS Control for Linux SL can not be used on virtual hardware Currently I run the package mentioned on a virtualized debian machine running in PROXMOX Virtual Environment 7.4-17 and apart from huge jitter it runs without problems. The CODESYS key is passed as a USB defice to the VM. I wonder why there are different statements regarding the suitability in virtual machines and if the jitter would be reduced by installing CODESYS runtime on the host installing CDS runtime on the host and using a preemptive kernel (if available for the PROXMOX installation leaving CDS runtime where it is (on the virtualized debian machine) and install a preemptive kernel on the host and on the guest... Any advice is appreciated. Greets Arno
Last updated: 2024-01-08
Post by jeindhoven on Deploying to raspberry pi 5 hangs
CODESYS Forge
talk
(Post)
Hi CoDeSys support forum, hope that this is the correct place to ask this. Might be double as i am new to Codesys and dont know all terminology. I am trying to test Codesys with a virtual plc on a raspberry pi 5. Already figured that i need Tools -> Deploy Control SL, enter Communication parameters. Codesys says "Connected". Then tab "Deployment", there i select "CODESYS Control for Raspberri Pi SL" and "4.16.0.0 (all)". Click "Install" and the gui turns grey and unresponsive. The titlebar says "Untitled1.project - CODESYS (Not Responding)" as well. Restarting Codesys and checking shows no package was installed. How to deploy the runtime? Thank you in advance for your time. Edit: After some patience, an error showed up: "Error when sending ssh heartbeat: Session operation has timed out" "Error installing codesyscontrol" Any pointers to what remote command might have failed, or log of some sort, would be welcome. Software versions: Codesys version 3.5.21.10 Raspberry pi 5 (deployment machine): $ uname -a Linux raspberrypi 6.1.21-v8+ #1642 SMP PREEMPT Mon Apr 3 17:24:16 BST 2023 aarch64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 11 (bullseye) Release: 11 Codename: bullseye $ apt list --installed | grep openssh-server openssh-server/oldstable,now 1:8.4p1-5+deb11u3 arm64 Development machine: $ uname -a Linux 2B 6.1.0-35-amd64 #1 SMP PREEMPT_DYNAMIC Debian 6.1.137-1 (2025-05-07) x86_64 GNU/Linux $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm VirtualBox Version 7.0.26 r168464 (Qt5.15.8) Virtual OS: Windows 10 Pro 64-bit (10.0, Build 19045) .NET version 4.0.30319.42000
Last updated: 2025-06-22
Post by otbeka on CAA File Handling: "Read only" error
CODESYS Forge
talk
(Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19
Post by dhumphries on install codesys runtime on linux
CODESYS Forge
talk
(Post)
I'm running the 3.5.18.20 IDE, installed the control for linux SL package from the installer. Following the directions here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_install_runtime_on_controller.html it says: Installing the runtime package with CODESYS on the Linux device Click Tools β Update CODESYS Control for <device> SL.</device> I don't have the update option in my tools menu. I've tried it without opening a project, as well as with a project open that uses the control for linux SL as a device. I have found the update device option by right clicking on the device in the device tree, but this only lets me change the device the project is using not load the runtime on the linux computer. Is there an updated instruction somewhere, or do I need to do some further preparation like install additional packages?
Last updated: 2023-11-04
Post by vamsi on How to configure gateway for programming RPi 2B using Codesys
CODESYS Forge
talk
(Post)
I am using a Raspberry Pi 2B. Installed Codesys V3.5.20.1 64-bit and installed 'CODESYS Control for Raspberry PI 4.12.0.0' I am able to install the packages using the 'Update Raspberry Pi' option, but when I try to log into the RPi, in the Device tab it says 'Sacn fail. Please checl that the gateway is running and that its settings are correct'. My setup looks like this. I connected my RPi to my company LAN and also my laptop to company LAN (using HP Docking station). This setup worked when I installed 'CODESYS Control for Raspberry PI', but now I donot know how to configure the gateway. Could anyone please help me in finding what I have to enter in the gateway configuration? Thanks, Vamsi.
Last updated: 2024-07-10
Post by rmaas on TargetVisu for Linux SL not starting
CODESYS Forge
talk
(Post)
Hello, I am trying to get TargetVisu for Linux working but i am having some troubles. The problem is that after installation it is not starting automatically on boot and i cannot start it from the update Targetvisu tool. When i try i get the following error (see attached screenshot) The file /opt/codesysvisualization/scripts/codesysvisualization_start.sh is missing... Steps performed: - installed fresh Debian 12.7 on virtual machine - installed all required libraries as described here: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_target_visu_for_linux.html - then installed the TargetVisu for Linux SL 4.13.0.0 using the Codesys IDE Does someone know how i can fix this? Best Regards, Rinie
Last updated: 2024-10-02
Post by timvh on Modbus TCP & RTU with Control for Linux SL
CODESYS Forge
talk
(Post)
It seems you have 2 network interfaces. Did you try eth1? Did you already configure the IP address for this interface in Linux? If yes, then maybe undo this. - or only set eth0 in the Nic configuration without anything else (so no IP address, because this is already set in Linux). For more information about the Nic settings, see (probably already read it?): https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_obj_deploy_control_sl_configuration.html PS, if you only want to run CODESYS Control SL, you don't necessarily need the Virtual PLC variant. You could also install and run the CODESYS Control SL Runtime in the Host operating system. This way you should also be able to access the serial port and directly access all ethernet ports. Maybe this is easier?
Last updated: 2024-10-23
Post by gatto on CAA File open Problems
CODESYS Forge
talk
(Post)
Ciao, here same question https://forge.codesys.com/forge/talk/Engineering/thread/2538729618/ in this post https://forge.codesys.com/forge/talk/Engineering/thread/4586a90290/?limit=25#d531 i find : keep in mind that all files which are generated / or read should be exist in the iecfilepath this means: for Windows (Control Win as example) c:\ProgramData\CODESYS\CODESYSControlWinV3x64\268E8ADF\PlcLogic for Linux /var/opt/codesys/PlcLogic I never use codesys on windows but im sure on linux we can manipulate file only inside /var/opt/codesys/Plc Logic. Or you need to modify the file codesyscontrol.cfg for change path permission, but this is another history Buone feste !
Last updated: 2024-12-21
Post by jeroenaero on Targetvisualisation full screen with CmpTargetVisu settings
CODESYS Forge
talk
(Post)
Hi, How can i display targetvisualization in full screen on the target device? I installed Targetvisu For Linux SL 4.16.0.0 on target device which contains Raspberry PI 64bit PIXEL desktop. When i connect my PLC program to the remote targetvisu, the targetvisu displays for 60% horizontally. We contacted CODESYS and they said it is a bug. they had a workaround, and with the settings below added to the file /etc/codesysvisualization/CODESYSVisualizationTV.cfg, the targetvisualization display for 100%, but with the taskbar at the top. VisuClient.BestFit=1 ;VisuClient.ScaleTypeIsotropic=0 VisuClient.FillWholeBackground=1 [CmpTargetVisu] WindowPositionX=0 WindowPositionY=0 WindowSizeWidth=1280 WindowSizeHeight=800 WindowType=2 How can we let it display fullscreen without taskbar?
Last updated: 2025-07-24
Post by valenting on Runtime not working on raspberry pi Bullseye
CODESYS Forge
talk
(Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01
Post by struccc on Application failing to boot after system reboot
CODESYS Forge
talk
(Post)
I started to experience the same issue, after upgrading to 3.5.19 , and still persists with 3.5.20.3 , using CodesysControlWinV3 x64 on Windows. Unfortunately, this is a live application, normally it is running for months without interruption - so it was a surprise at the last cold start... It was not possible to go online with the original version, so I couldn't see the application, or system status, just the log message. First time I manually clean the Application from the PlcLogic directory (there was no coredump file in there), then I could start the runtime service, and do a fresh download, and set the bootproject. I could not try a cold system reboot - it's in a 24/7 production environment, and I was under heavy pressure to start... What I did, I have created a backup from the * complete * runtime directory, from the failed, and fixed version - before and after download. This directory in my case C:\ProgramData\CODESYS\CODESYSControlWinV3x64\55096128 - At the next shutdown, it was sufficient to copy back this backup completely, and could start the runtime service afterwards. Ugly, but local staff with some skills can do it without programming tool... I don't store any live data, configuration, log files, persistent data in this directory - the only reason I need this is to edit the CodesysControl... .cfg file.... And to see the logfiles in emergencies like this. The application concerned doesn't use any retain area. - exactly for these reasons - Maybe that is causing the problem with the newer runtime versions As far as I see, this problem occurs only if the power of the Windows PLC is interrupted without a proper shutdown. Unfortunately, this can happen sometimes. The newer versions, seems tp modify CodesysControl.cfg on the fly, and register the applications, and bootproject information after download. (I don't really see CodesysControl.cfg a proper location for this... but that's just my feeling) So now I had a look at CodesysCotrol.cfg on my laptop and I found: [CmpRetain] ;Retain.SRAM.Size=0x200200 ;Retain.SRAM.Address=0xFA3C5776 ;SimulateSRAM=1 [CmpApp] ;Bootproject.CreateOnDownload=0 ;Bootproject.StoreOnlyOnDownload=0 ;Bootproject.InvalidateByRename=1 ;Bootproject.InvalidateBySetting=1 ;Bootproject.InvalidateNever=0 ;PersistentForce=0 ;RetainType.Applications=InSRAM ;RetainType.Applications=OnPowerfail ;RetainType.Applications=None ;Exception.Hardware.GlobalStop=1 Application.1=MyTestAppNoRetain The last line appeared after download and boot project creation. Maybe... Should set RetainType.Applications=None? I wonder about all these settings, but... Will write separately about it. I hope this helps a little...
Last updated: 2024-11-21
Post by moksan on Unconnected_Send Explicit message with Route Path
CODESYS Forge
talk
(Post)
I have been trying out Unconnected_Send Explicit Message with route path.(The Unconnected_Send service shall use the Connection Manager object in each router to forward the message and to remember the return path. Vol 1.3 / 3-5.6.7) However, I could not see the correct path on Wireshark. I want to see the Unconnected_Send Message Service Code as 0x52 and also the last of the message should have the route path. I want to ask some questions about this topic. The IIoDrvEIPAcylicServices Interface has the IoDrvSendUnconnectedMessage Method. And there is a struct (EIP_SendUnconnectedMessage) for this service. But there is no information about how to implement to project, and if it is successful, does it send a message with 0x52 Unconnected_Send Service Code or not? If that is not a solution, how can I set the Unconnected_Send Explicit Message struct on Codesys? Also how can I send explicit message with route path?
Last updated: 2023-10-17
Post by climblinne on Calling OPC UA Methods from UaExpert
CODESYS Forge
talk
(Post)
Hello, I hope someone could help me. I installed the newest Codesys 3.5 SP 20 Patch 1. When loading the demo files from @i-campbell I can upgrade them to the latest version and everthing works on the OPC-UA client side as expected (object "a" is visible, I can use the "ExampleMethod"). Now I * remove the "Information Model", * delete the "OPC_UA_Symbols Objects", * Add "Information Model" again * add "TestRootObjectType" again and "Generate IEC declarations" * and search for mapped instances (to get instance "a" again) Very good still working as expected. Now I delete the OPC_UA_Symbols and add it again referring to the "objecttest" from 16.9.2020. Also I redo the steps from above. The result is now, that I can't see the "a" object in the "Root/Objects" folder. Why ist this and how can I make it running? I think, it could may be a different version of the UA configuration file. I tried to build my own model definition files and got the same problem (but I am really not an expert). When someone has a actual model, which is also running in the actual Codesys I would be very grateful. Or even better, how to make the correct model in e.g. UA Modeler SW (I followed the description https://documentation.unified-automation.com/uamodeler/1.6.0/html/howprojnet_sec.html).
Last updated: 2024-07-01
Post by ahuckphin on Issues with Modbus Slave with Raspberry Pi
CODESYS Forge
talk
(Post)
I have a DFRobot RS485 temperature & humidity sensor (SEN0438) connected to my Raspberry Pi via a USB to RS485 adapter. I am able to connect and read the sensor data when running a python code locally. However in Codesys, I encounter this error "A bus error has occurred." and "There was no response in time". Could this be because of Modbus Server Channel and Modbus Server Init configuration on my part? Admittedly I am new to Codesys. To get to this stage, I: 1. added some lines to CODESYSControl_User.cfg 2. added "Modbus_COM" in Codesys and set "Serial Port Configuration" under "General" 3. added "Modbus_Master_COM_Port" in Codesys and checked transmission mode is set to "RTU" 4. added "Modbus_Slave_COM_Port" in Codesys and checked server address is set to 1 (also set 1 in my sensor) 5. added 1 channel and 1 init for "Modbus_Slave_COM_Port" under "Modbus Server Channel" and "Modbus Server Init"
Last updated: 2024-07-10
Post by latassan on RaspberryPi 5 gateway problem
CODESYS Forge
talk
(Post)
Hello, I'm trying to use a raspberryPi 5 as a PLC. I fixed its IP address, I can ping it. I've also installed the CODESYS Control for Raspberry Pi 64 SL runtime on it. So I've created a gateway (IP address of the Raspberry, TCP port 1217). I see the green dot next to this gateway. When I do a network scan, I can see my raspberry (see photo). When I try to connect to it, I have to define an administrator profile, which I do. On validation, I see a message: No device is responding to the scan request. I've checked that port 1217 is listening on the raspberry, I've uninstalled the runtime then installed it again, but I can't connect. Also, when I try to configure the user groups before connecting, I see that Offline mode is not supported by the device, even though I'm connected to it in the Deploy Control SL tab. When I try to refresh, I see: Gateway not configured properly. How can I connect to my Raspberry? Have I defined my gateway incorrectly?
Last updated: 2025-06-12
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Sorry for the question, but I'm not completely getting the idea here, could you be more specific, maybe give an example? I'm now in a state where I don't have a softcontainer on my license server anymore (even after reinstalling from the Codesys-IDE). I tried reaching the webserver of Codemeter but when I do that I get redirected to http://"IP":22352 This is not reachable, afterwards I installed lynx on my Debian machine (command line only). From here I could reach the webserver and toggle the network server setting, but unfortunately this did not help. I also tried to changed the remote read setting to 1 (in the Server.ini file). But after a Codemeter reboot this is overwritten to 0. I have the feeling that it should be much easier to get a license to work, am I missing some checkbox somewhere? Is there a tutorial (or manual) that explains the licensing sequence step by step, because I'm pretty stuck.
Last updated: 2025-10-01
Post by spiessli on Softmotion axis to CANopen Maxon IDX drive
CODESYS Forge
talk
(Post)
Thanks for the advise, indeed, this was somewhat, what my intention was. I tried around again with EDSes and DCFs, anyway. It appears that the DCFs end up in a subfolder in the attach device dialog. Astonishingly, when attaching the DCF version I get a device in the device tree, where I can add a SoftMotion axis, whereas when I attach the device not in the subfolder, then I cannot. Further astonishingly, when looking in the CANopen parameters in supported profiles, "402" is listed in the case of the DCF variant, whereas in the EDS variant "0" is shown. Comparing EDS and DCF files I cannot guess, where the difference is coming from. I cannot tell either why I have always attached the EDS variant and apparantly never the DCF variant. As I am not in the lab right now, I cannot test if the connection actually is working. Thanks again, spiessli
Last updated: 2024-01-07
Post by thewizard8 on Raspberry PI4 Serial Port
CODESYS Forge
talk
(Post)
Hi Dear All, I'm using my raspberry PI4 as a CoDeSyS PLC (Build from scratch with custom electronics). I was able to implement all fieldbuses with the exception of Modbus Serial. I'm using the internal Port (GPIO) and I configured it in /etc/Codesyscontrol_user.cfg the following away: [SysCom] Linux.Devicefile.1=/dev/ttyUSB0 Linux.Devicefile.2=/dev/ttyS0 I'm using COM2 on Master configuration. I'm using a interface board from TTL/RS485 (bidirectional board), and it's works perfectly with other devices but not in CoDeSyS. I'm able to send data with python script and read it on my pc using putty, but when I use a modbus slave simulator to interface with codesys I always get red icons on master and slave. (Please find image attached). I'm pretty shure that this might be a bad parameter on my CoDeSyS runtime configurstion file. Can someone help me? I'm stuck and this is for my master degree certification.
Last updated: 2024-03-18
Post by fontrap on cmDongle Raspberry Pi issue
CODESYS Forge
talk
(Post)
Hello mates, I'm working with CODESYS V3.5 SP20 on a Raspberry Pi and I use "Raspberry Pi MC SL" as device on the project. I've installed the Control Standard L (multicore) license on a Wibu System usb-Dongle (cmStick/4.50) that already had another license from another vendor. I follow the online activation procedure from CODESYS documentation. Raspberry Pi has already CodeMeter installed for the other license. When I plugin the dongle on Raspberry and start the Runtime from Raspberry Pi Update in CODESYS I receive the message that I'm on Demo mode because the license is missing. I double checked that the license is activated in the dongle, through the WebAdmin of CodeMeter and the second license runs properly without any issue. I have already try to change the dongle from HID to MSD device and backward but the the Runtime cannot recognize the Dongle. I have also try to stop and start the Runtime through CODESYS without success. Is there anything else I can do to fix this issue?
Last updated: 2024-04-22
Post by jrsantab on Remote connection to ifm PLC & HMI
CODESYS Forge
talk
(Post)
We have finally solved the problem. The version of the Gateway in the computer that worked (3.5.11.0) and the one that didn't (3.5.17.30) was different. We have three different Codesys 3.5 versions installed because we work with different controllers. I believe that, depending on the sequence you follow to install the versions you get a different Gateway version. To solve the problem you first have to disable the "obsolete" services. Open services, serach for (in our case) CODESYS Gateway V3 Version 3.5.11.0 CODESYS ServiceControl Version 3.5.11.0 I stopped the services and changed to Manual Start. Then you have to create the new services. In our case, from a Command Prompt session (cmd): SC CREATE "Codesys GatewayService Rigual" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\GatewayService.exe" and then SC CREATE "CODESYS ServiceControl Version 3.5.17.30" binpath="C:\Program Files\CODESYS 3.5.17.30\GatewayPLC\CODESYSControlService.exe" remember also to set them as Automatic Start!
Last updated: 2024-04-22