Post by jeindhoven on Deploying to raspberry pi 5 hangs
CODESYS Forge
talk
(Post)
Yep sure, though now that i think of it, its a pi 4. My bad. The whole ordeal was necessary to use the VGA666 adapter. That needs the old graphical system and GPIO directly on the CPU. Edit: Putty on the virtual development machine connects fine. But i did change the login/pw. The account is still a sudo'er so that should be all right. Edit2: Sorry i get a "Comment rate limit exceeded" from the forum. Then i'll add it as edit here. So i have tried the stock raspberry pi image on a different pi5 (truly 5 this time). Packages updated. Standard password. Same symptoms, no runtime deployed and long hang time. Versions of this pi: pi@raspberrypi:~ $ uname -a Linux raspberrypi 6.12.25+rpt-rpi-2712 #1 SMP PREEMPT Debian 1:6.12.25-1+rpt1 (2025-04-30) aarch64 GNU/Linux pi@raspberrypi:~ $ lsb_release -a No LSB modules are available. Distributor ID: Debian Description: Debian GNU/Linux 12 (bookworm) Release: 12 Codename: bookworm pi@raspberrypi:~ $ apt list --installed | grep openssh-server openssh-server/stable,now 1:9.2p1-2+deb12u6 arm64 [installed,automatic] Attached is the Device information and error text that Codesys comes up with. Edit 3 (Comment rate limit, otherwise it would be a new post) Now i have tried booting an older native Windows 10 machine (no virtualization), and it just works as expected. I have now a raspberry pi 4 and raspberry pi 5 with version 4.16.0.0 of the control application. Windows 10 native: build 19045 (same as virtualised Win 10), same .NET version, same CODESYS version. It seems that running CODESYS virtualized somehow messes with the deployment?
Last updated: 2025-06-23
Post by jami on Reading multiple lines from csv file
CODESYS Forge
talk
(Post)
Hello, i am trying to read multiple lines from csv file with caa file library and oscat. I have wrote 7 lines in the csv with separation '$R$L'. In my "extracting values" part I check line feeds and chars. After that I convert my buffer to string with oscat but I'm only able to read the first line from the csv. No matter if I even change start position where I start converting the buffer, I only get the first line. Here's my code for the reading and extracting value parts: 4: (*Reading the file*) fileread.hFile := filehandle; fileread.pBuffer := ADR(buffer); filesize1:=SIZEOF (buffer); fileread.szbuffer:=filesize1; fileread.udiTimeOut := 100000; fileread(xExecute := TRUE); IF fileRead.xDone THEN iFilesize:=TO_INT(fileread.szSize); writestate:=3; fileRead.xExecute := FALSE; END_IF 5: (*Extracting values*) //here i check the number of line feeds and chars. It works WHILE i < ifilesize DO c:=buffer[i]; IF c= 10 THEN IF lineindex<=99 THEN lineIndex := lineIndex + 1; END_IF ELSIF c <> 13 THEN IF charIndex <= 1000 THEN charIndex := charIndex + 1; END_IF END_IF i := i + 1; END_WHILE // Here i convert the buffer to string and transfer it to filelines:ARRAY[0..99] of string[254]. trig(CLK:=BUTTON); IF trig.Q THEN fileLines[i2]:=oscat_basic.BUFFER_TO_STRING(PT:=ADR(buffer), Size:=TO_UINT(fileread.szBuffer), start:=TO_UINT(bufferStart), stop:=TO_UINT(filesize1)); i2:=i2+1; bufferstart:=bufferstart+80; END_IF If anyone has idea how to read multiple lines, it would be nice. Even if you have example codes that work, that would help a lot.
Last updated: 2025-07-18
Post by akrawczyk on Dynamically enabling/disabling Modbus slave devices in runtime (performance issue with timeouts)
CODESYS Forge
talk
(Post)
Hi everyone, I'm working on a CODESYS-based project running on a Weintek cMT2078X HMI with a built-in CODESYS runtime. The system communicates with multiple Modbus RTU slave devices, arranged in a cascade. The number of connected units can vary between 2 and 8, depending on the installation. Each slave has 17 Modbus channels, which are polled cyclically every 5 seconds. The issue is that when fewer devices are physically connected (e.g. only 3 out of 8), the Modbus master still attempts to communicate with all configured slaves. This leads to massive delays due to timeouts (currently 200ms per channel). For one disconnected device, thatβs: 17 Γ 200ms = 3.4 seconds of delay per polling cycle, and this quickly multiplies with each additional missing slave. This behavior significantly degrades the system's performance and responsiveness. We attempted a workaround where we tried to trigger polling based on a variable in the PLC program, but this caused instability and even led to hardware hangs/freezes on the cMT2078X β likely due to clashes in how the Modbus polling engine and program logic interact at runtime. My main questions are: Is there a way in CODESYS to dynamically enable/disable Modbus slave devices at runtime, using a BOOL or INT variable (e.g. indicating number of active slaves)? Can devices or channels be conditionally polled or temporarily disabled without removing them from the device tree? Are there any best practices or examples for handling variable numbers of Modbus slaves in scalable systems like this? Would splitting communication across tasks or interfaces help reduce the impact of timeouts? Any advice, documentation references, or architectural suggestions would be extremely helpful. I'm looking for a robust way to dynamically scale slave polling without degrading system stability or performance. Thanks in advance!
Last updated: 2025-08-11
Post by jasonhogan on Login problem with FileTransfer on Raspberry Pi 5
CODESYS Forge
talk
(Post)
Thatβs a classic CODESYS quirk. As soon as you enable AllowFileTransferServices=1, the web server locks down and demands authentication for everything, including WebVisu sessions. Since you're on a Raspberry Pi / Linux, trying to make the built-in CODESYS web server do both secure file handling and unauthenticated kiosk visu is usually a losing battle. A couple of ways to get around this: The cleaner route (separate the jobs): Turn AllowFileTransferServices back off in the config so your kiosk WebVisu opens freely without any login prompts. Then, handle the file download outside of CODESYS β just run a dead-simple Nginx/lighttpd file server or a tiny Python script on the Pi pointed at your export folder (/var/opt/codesys/...). That way your PLC security stays intact, and the kiosk screen just works. If you really want it through CODESYS: Check your Device -> Users and Groups in the IDE. Make sure the Everyone / Anonymous user group actually has explicit view permissions checked for the Visualization. Sometimes when file services are toggled, anonymous users lose the default visu-read rights and get booted straight to the login dialog. URL / Browser trick for kiosk: If the Pi is just opening a local browser on startup, you can sometimes pass the basic credentials in the browser launch script or use a small reverse proxy on localhost to inject the headers automatically so you don't see the popup. Honestly, running a lightweight HTTP/FTP endpoint on Linux (option 1) is by far the least headache.
Last updated: 2026-08-15
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.