Post by davidmic on Is it possible to profile builds?
CODESYS Forge
talk
(Post)
Hi I have a large project (which I can't share here), builds take multiple minutes. My computer is reasonably new (i7-10610U, 32gb ram), and I don't think my company will let me upgrade. Is there any way to profile/inspect the build process? My goal is to figure out why builds take so long, then hopefully I can make them faster.
Last updated: 2024-06-05
Post by matt-purcell on Which Lib to use, connect to a socket with URL instead of IP address
CODESYS Forge
talk
(Post)
I've been searching through these libraries, syssocket and net base services and they all seem to use the same structure for IP address for the connect function, SOCKADDRESS. At a glance, it doesn't look like that'll work, maybe it's just missing in the documentation somewhere?? I'm wondering if anyone has done it.
Last updated: 2024-06-17
Post by denizerm on Deploy Control SL cant find Podman
CODESYS Forge
talk
(Post)
I found something that might be the main cause for this: /etc/os-release features the ID=debian entry on my reference system; When i temporarily override my DUTs os-release to feature ID=debian or similar its able to detect Podman. Is there a way to fix this behaviour?
Last updated: 2025-10-24
Post by kporter on SoftMotion, accessing PDO input data via object ref/pointer
CODESYS Forge
talk
(Post)
Now that SP21 is out, what's the answer? I want to get a pointer to the TxPDO and RxPDO structs. I can generate a STRUCT declaration from the ESI file with a bit of Python. I just need to get the pointer from the ETC_Slave.
Last updated: 2025-10-29
Post by michaelhepiroc on CIA405.RECV_EMCY
CODESYS Forge
talk
(Post)
Hi Reinier, I'm wondering if you managed to get this FB to work? I was just trying it, and found it not to work, I get an EMCY message in the CodeSys program under the Device Status, but the FB doesn't pick up any EMCY messages from the Bus. Cheers.
Last updated: 2025-12-08
Post by gseidel on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hi bertus, thanks for the additional information. Setting bAbort on a restart is not needed. Calling all FBs starting from the decoder up to checkvelocities with bExecute = FALSE and then giving a new rising edge on bExecute is what should be done. Do you also restart the Interpolator? (I don't think that has anything to do with the issue, but still...) Best regards, Georg
Last updated: 2025-12-23
Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken?
CODESYS Forge
talk
(Post)
There is currently a bug with the Raspberry Pi 64 SL where it is unable to Trend Global Retain or PersistantVars. The work around is to use standard Global Variables for Trend Data. This will be patched by Codesys in the near future reference "VIS-6170"
Last updated: 2025-11-13
Post by poliautomacao on Absolute movement controlled by an external encoder.
CODESYS Forge
talk
(Post)
Hello, is it possible to perform an MC_MoveAbsolute movement, and have the servo move using an external encoder (freeEncoder)? In my application, I have slippage on the main shaft of the servo motor, and I would like to add an encoder to measure the actual position of the material.
Last updated: 2026-03-04
Post by reinier-geers on Network variable stops sending
CODESYS Forge
talk
(Post)
I use network variables. But when i change the programm, it wil stop sending. Then is have to add or delete a variable. Then i will be compiled again and sends again. This problem wasw already in 9.20 but seems to be still in 21.0 . Is there a way to solve this ?
Last updated: 2026-04-20
Post by yannickasselin on Question about Demo License limitations for Modbus TCP communication and Fieldbus Instances
CODESYS Forge
talk
(Post)
As far as I know, there is no other limitations than the 2 hours limit. The demo mode should be plenty enough for testing purposes. Regarding instances. In the device tree, 1 master = 1 instance, no matter how many slaves the master is communicating with. But it is also possible that your Codesys runtime act as a slave. In this case, each slave in the device tree is one instance. You can also use the license metric tool in the IDE. This will tell you exactly how many instances you have in your project. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_edt_device_licensed_software_metrics.html
Last updated: 2026-02-28
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Hello, I hv a problem. Couldn't solve this for 2 days now. So I'm quite new at CodeSys and I have to use the spi port x30 on the edgelogix rpi 1000. So what I have to do is just 'add device' at the SPI where I hv to pick the 'SPI master' after that I hv to change the parameters according to the edgelogix I did found in the spidev.h but nothing got updated so I 'add device' again where I pick the PiFace I/O Driver and I put my variables at the I/O Mapping, which i put the input startbit at the in part and led at the out part. I want to make the led blink according to my structured text code but somehow the hardware didn't connected with the CodeSys spi port. Nothing happens. Any idea what I have to do?
Last updated: 2023-08-18
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
i found this error in /opt/CoDeSysControl/Files
Last updated: 2023-08-25
Post by timvh on CANbus issue
CODESYS Forge
talk
(Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
Thanks, I will check the PLC Log when the PLC is connected again. I will update my findings here. Since I don't have access to the Linux Panel PC at the moment, I tested inside my development VM with the same Linux OS. I have no issues or delays connecting to the WebVisu using my Linux VM. Two main differences: 1. My host Computer has a faster processor compared to the panel PC. 2. There are no devices connected in my dev environment. I will continue testing when I have connection to the panel PC.
Last updated: 2023-09-23
Post by eschwellinger on PFC200 Update to 4.9.0.0 - No Connection
CODESYS Forge
talk
(Post)
which PFC Firmware is this? -check with wbm
Last updated: 2023-09-28
Post by ofey on Symbol configuration / GVL
CODESYS Forge
talk
(Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11
Post by ofey on Symbol configuration / GVL
CODESYS Forge
talk
(Post)
Hi! I have som variables that I communicate to a Modbus Master. These variables are declared in a "Global Variable List" where I have assigned them memory addresses. To organize this mapping I want to make a MODBUS list where I show all the variable names together with the memory address. Is there an easy way to export this list from CODESYS? Either through script or some export function maybe?
Last updated: 2023-10-11
Post by rafaelbrito on User management - User Tab missing
CODESYS Forge
talk
(Post)
Click in "Convert to Legacy"
Last updated: 2023-10-17
Post by davidbo on RPI is license server down
CODESYS Forge
talk
(Post)
I try to install license on server license.codesys.com.
Last updated: 2023-10-18
Post by eschwellinger on install codesys runtime on linux
CODESYS Forge
talk
(Post)
could you try to add the command in Tools-customize
Last updated: 2023-11-04
Post by totorovic on Pointer to Softmotion axis
CODESYS Forge
talk
(Post)
I get the same warning message with initialized variable. Codesys 3.5.19.20
Last updated: 2023-11-09
Post by nizrahel on OpC UA server on Raspberry Pi 64 SL runtime
CODESYS Forge
talk
(Post)
Hi all! I'm working on an home project using a Raspberry Pi 3 device with Codesys for Raspberry Pi 64 SL runtime. I would like to create the HMI interface with Siemens WinCC Unified (or Advanced) configuring the Raspberry as OPC UA server. I tryed everything, but I didn't find the way to let the OPC UA connection works using UaExpert. I tryed to use anonymous connection, authenticated connection and the ip address instead of the server name in the path connection. There is no way to connect to the OPC UA server and I was asking myself if this feature is really supported for the runtime version used. Another strange thing I noted, is that is not possible to quickly create an OPC UA certificate in the Security Screen, as show in any tutorials. I have correctly created the Symbol Configuration enabling the OPC UA feature. I attach to this topic some printscreen of the actual configuration (sorry for the italian language interface, but I didn't find the way to switch to english). Thank you very much in advance for your support and advices!
Last updated: 2023-12-03
Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state?
CODESYS Forge
talk
(Post)
It's already there, the service get started as default. I missed to say that sometimes it happens w/o even the system get restarted. Anyway, the main issue here is to know the state of the runtime. We collect a lot of informations about the whole system, and it would be nice to have a way to detect the runtime state.
Last updated: 2024-07-02
Post by wollvieh on Trouble Writing Files to External Paths in CODESYS
CODESYS Forge
talk
(Post)
https://content.helpme-codesys.com/de/CODESYS%20Control/_rtsl_windows_win_v3_dynamic_components.html
Last updated: 2024-07-05
Post by disha on SQLITE connection
CODESYS Forge
talk
(Post)
Are you able to do it? Can you please help me out?
Last updated: 2024-07-08