Post by simotion on Codesys Softmotion Win V3 x64
CODESYS Forge
talk
(Post)
I have a project in Codesys v3.5 sp19 patch2 that contains softmotion virtual axes. I want to simulation the code (softmotion) on the simulated plc on the pc. The controller in the project is a Codesys Softmotion Win V3 x64. I have started up the Codesys Softmotion Win 64 on the pc. However it seems a 3.5 sp14 controller. When trying to download the project, I get a message that target system is different from connected system (3.5.19 vs 3.5.14). How do I set the connected system to 3.5.20 (there seems no way to set the target system to 3.5.14
Last updated: 2023-10-04
Post by kumareasu on Runtime System Update
CODESYS Forge
talk
(Post)
When I change the hardware Do I need to buy licence After three years ? Please refer the jpg file.
Last updated: 2023-11-26
Post by snhatton on Saving variable values on power cycle (RevPi Connect)
CODESYS Forge
talk
(Post)
Have you tried using the persistence manager which uses the file system of the controller to store persistent variables?
Last updated: 2023-12-04
Post by eschwellinger on Licensing info not available.
CODESYS Forge
talk
(Post)
you need a license server on the host or on any system in your environment.
Last updated: 2024-09-23
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
I have noticed that a rm file1.txt command on a shell has an impact on the cycle time for a TASK writing to file2.txt. Seen in the Monitor fane of the Task configuration Furthermore if a TASK makes a system call like rm, its cycle time increases of course but it seems to have an invisible impact on other TASKs too. I have a TASK for handling communication over the CANbus (SPI) where it stops sending "Heartbeats" for many seconds when another TASK does a system rm. Why is that not seen on the Monitor fane? Is even codesyscontrol paused when system calls are made? The CPU load is about 30-40%
Last updated: 2024-09-23
Post by eschwellinger on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
Which version exactly do you use?
Last updated: 2024-09-23
Post by eschwellinger on Persistence Manager: Config File not found?
CODESYS Forge
talk
(Post)
I would check with the CODESYS file browser if these files exits on your system (PlcLogic directory)
Last updated: 2024-11-02
Post by ballen on Datasource OPC UA client system failure
CODESYS Forge
talk
(Post)
Have you had any luck figuring this issue out?
Last updated: 2025-01-16
Post by alawwirbilal on Codesys for raspberry pi 5 not working exactly
CODESYS Forge
talk
(Post)
Note: this runtime system is used thanks in advanced!!
Last updated: 2025-03-06
Post by pernockham on *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv
CODESYS Forge
talk
(Post)
*** The system may be in an inconsistent state, please reboot *** *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv Every time at the instant that I Login to the system a message that the "system may be in an inconsistent state, please reboot" is written in the log. If I logout and repeat login a new entry is set. My system is a "Control for linux SL" running on a debian linux host. Im running it on my desk without any IO attached so message might be caused from that, but I doubt i have seen it before. Rebooting makes no difference. Anyone that have a clue of how I should interpret this error message?
Last updated: 2025-09-26
Post by eschwellinger on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05
CODESYS Forge
talk
(Post)
https://de.codesys.com/das-system/releases-updates-lifecycle/release-plan-roadmap.html ... 20.2
Last updated: 2024-02-02
Post by nilo on How to get the system time in milliseconds?
CODESYS Forge
talk
(Post)
Hi, thanks for sharing your final results. may I ask why are you diving by 10?
Last updated: 2024-02-28
Post by peterned on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that?
CODESYS Forge
talk
(Post)
Hi, I have a XY system and use a CNC file to move it. Everything works OK, except for the following: when CNC execution starts, the system rushes at high speed to (X=0, Y=0) point, and only then goes to the first line of the CNC file. If one of the axes is near 0, the system jumps and immediately stops with an error. In the CNC file settings (screenshot attached) I specified low default values for speed/acceleration and a start position different from 0,0 - but all that is ignored. Any idea how to avoid that move to 0,0 ? Thanks.
Last updated: 2024-04-26
Post by peterned on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that?
CODESYS Forge
talk
(Post)
Thanks Georg, that fixed it.
Last updated: 2024-05-07
Post by micik on CAA File- FILE_OPERATION_DENIED error
CODESYS Forge
talk
(Post)
Thank you wollview, it is clear now, it is due to security reasons that access to the file system is restricted.
Last updated: 2024-05-16
Post by paro on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications
CODESYS Forge
talk
(Post)
CmpApp https://forge.codesys.com/prj/codesys-example/application-man/home/Home/
Last updated: 2024-06-17
Post by somlioy on CODESYS Control for PFC100 SL Firmware upgrade
CODESYS Forge
talk
(Post)
Hi We delivered a system with a PFC100 using the CODESYS Control for PFC100 SL runtime a few years back. The system has once been decommissioned and are now to be commissioned again. Back then, there were only single licenses for the runtime. Can I now upgrade the firmware and runtime without purchasing a new license?
Last updated: 2025-02-27
Post by open on How to create a stopwatch?
CODESYS Forge
talk
(Post)
Hi @ph0010421 and @Ton, Is it possible to program a stopwatch to measure a system running time when it is turn on, and pause when the system is turn off. I tried your examples when stopped, the elapsed time will then be calculated, but i need the time to be continuously counting. Warmest regards,
Last updated: 2023-12-11
Post by umdee on Error when monitoring LAD programs
CODESYS Forge
talk
(Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19
Post by simotion on Inheritance of axis
CODESYS Forge
talk
(Post)
I have developped a function block 'Axis' the inherits from 'AXIS_REF_SM3' -> FUNCTION_BLOCK Axis EXTENDS AXIS_REF_SM3 In my global variable list I define a variable MasterDrive of type Axis and assign Axis1. Axis1 is a virtual drive (AXIS_REF_VIRTUAL_SM3). This type should inherit from AXIS_REF_VIRTUAL. VAR_GLOBAL MasterDrive : Axis := Axis1; However I get the error 'Cannot convert type'. What is the way to obtain what I want : function block inheriting AXIS_REF_SM3 and initialising this function block with a Softmotion virtual or real axis?
Last updated: 2023-12-07
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by jbu0105 on Dynamic limits invaild
CODESYS Forge
talk
(Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22
Post by micik on CAA File, how to check whether file exists or not
CODESYS Forge
talk
(Post)
Hello, what would be the most efficient way to check whether the file exists or not. I don't want to use file.Open function, it seems like rather inefficiet operaton. I considered GetAttribute function, but this function doesn't accept filename (with path) as an input. Basically I need to check first time when program is loaded to the runtime i.e. when application is started for the first time, whether a file exists on the specific location or not.