Search talk: library documentation and support

 
<< < 1 .. 180 181 182 183 184 .. 190 > >> (Page 182 of 190)

Post by harryc on Soft Container License issue with ARM64 Linux CODESYS Forge talk (Post)
Hi, We are working to provide our customers with CODESYS operation on our hardware product ( https://elprotech.com/product/el-qe-e-quantum-edge-series/ ). I'm trying to enable a CODESYS license (Soft container) on our product running ARM64 linux. This problem am having looks similar to here: https://forge.codesys.com/forge/talk/Runtime/thread/6d29b6b4de/ and here: https://forge.codesys.com/forge/talk/Runtime/thread/a2d0c63375/; but I am not running docker, and I am not re-installing a license. This is first time install. I have CODESYS Control SL running on my device, as well as CodeMeter. I purchased a license, and installed it to the CODESYS Development system, (Tools >> License Repository) then tried to install to the device (Tools >> License Manager >> o Device >> o Soft container >> Remote [0001] >> OK. This gives me the "License Manager - Overview" dialog, and the message "Licensing info not available. There is no dongle attached to the device." Below shows the running applications, installed packages, and current content of /var/opt/codesys Also attached screenshots of the Development software as I go through the steps to install the license. # # ps | grep -e "code" -e "CodeMeter" 1391 daemon /usr/sbin/CodeMeterLin 1407 root /opt/codesys/bin/codesyscontrol.bin /etc/codesyscontrol/CODESYSControl.cfg 1442 root /opt/codesysedge/bin/codesysedge.bin /etc/codesysedge/Gateway.cfg 29229 root grep -e code -e CodeMeter # dpkg -l Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Architecture Description +++-==============-=============-============-============================================================================================== ii codemeter-lite 8.20.6539.500 arm64 WIBU CodeMeter minimal runtime ii codesyscontrol 4.14.0.0 arm64 codesyscontrol based on SDK 3.5.20.40 , from Fri Nov 29 08:35:37 CET 2024 [265], Release build ii codesysedge 4.14.0.0 arm64 codesysedge based on SDK 3.5.20.40 , from Fri Nov 29 08:34:19 CET 2024 [265], Release build # ls -la /var/opt/codesys total 208 drwxr-xr-x 6 root root 4096 Nov 7 05:31 . drwxr-xr-x 1 root root 4096 Nov 6 08:33 .. -rw-r--r-- 1 root root 23515 Nov 7 07:26 .Audit.log -rw-r--r-- 1 root root 160 Nov 7 05:31 .GroupDatabase.csv -rw-r--r-- 1 root root 160 Nov 7 04:37 .GroupDatabase.csv_ -rw-r--r-- 1 root root 20736 Nov 29 2024 .SoftContainer_CmRuntime.wbb -rw-r--r-- 1 root root 1982 Nov 29 2024 .UFC_SoftContainer_CmRuntime.WibuCmLif -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv_ -rw-r--r-- 1 root root 11807 Nov 7 05:30 .UserMgmtRightsDB.csv drwxr-xr-x 6 root root 4096 Nov 6 08:30 .pki drwxr-xr-x 3 root root 4096 Nov 6 08:30 OPCUAServer drwxr-xr-x 7 root root 4096 Nov 6 08:30 PlcLogic -rw-r--r-- 1 root root 13 Nov 6 08:30 SysFileMap.cfg -rw-r--r-- 1 root root 2640 Nov 29 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Nov 6 08:30 cert -rw-r--r-- 1 root root 94105 Nov 7 07:25 codesyscontrol.log # # uname -a Linux Remote 6.1.22 #5 SMP PREEMPT Tue Nov 18 11:35:46 AEST 2025 aarch64 GNU/Linux #
Last updated: 2025-12-04

Post by elektron785 on GPIO mit Codesys Virtual Control for Linux ARM64 SL CODESYS Forge talk (Post)
Hallo zusammen, ich möchte an einem Entwicklungsboard auf dem der i.MX 8M Plus von NXP aufgesteckt ist die vier zur Verfügung gestellten GPIOs als Ausgänge verwenden. Ich habe mir dazu die Readme-Datei des GPIO-Beispiels von "C:\Program Files\CODESYS 3.5.20.40\CODESYS\CODESYS Control SL Extension Package\4.14.0.0\Examples\GPIO" angeschaut Die Übersicht der verfügbaren GPIOs sieht folgendermaßen aus - wobei ich das auf die reduziert habe, die für mich von Interesse sind: gpiochip0: GPIOs 0-31, parent: platform/30200000.gpio, 30200000.gpio: gpio-0 (SODIMM206 ) gpio-1 (SODIMM208 ) gpio-2 ( ) gpio-3 ( ) gpio-4 ( |sd-vsel ) out hi gpio-5 (SODIMM210 ) gpio-6 (SODIMM212 ) gpio-7 (SODIMM216 ) gpio-8 (SODIMM218 ) gpio-9 ( ) gpio-10 ( ) gpio-11 (SODIMM16 ) gpio-12 (SODIMM155 |regulator-usb1-vbus ) out lo gpio-13 (SODIMM157 ) gpio-14 (SODIMM185 |regulator-usb2-vbus ) out hi gpio-15 (SODIMM91 )** Füge ich nun das GPIO (1 Bit)-Gerät in meinem Codesys-Programm hinzu funktioniert der Bus solange bis ich die Richtung in den GPIO-Parametern von "not used" auf "Output" stelle (siehe Bild gpio_parameter). Dann funktioniert nach Download der Bus nicht mehr. Gibt es noch eine andere Möglichkeit das zu steuern oder muss ich noch Einstellungen tätigen? Für die Zeile mit dem echo (export/unexport) aus dem Beispiel fehlen mir trotz sudo die Zugriffsrechte. "The Kernel Linux has deprecated GPIO user space SysFS. However, the kernel config CONFIGGPIOSYSFS is still enabled on Toradex's BSP to support customers using it in their legacy applications. You can check the configuration by running zcat /proc/config.gz | grep CONFIGGPIOSYSFS. For GPIO access from userspace, the new char device API, also known as libgpiod, must be used." Dies steht in der Verwendung der GPIOs - eine Ausführung des zcat-Kommandos liefert ein =y zurück.
Last updated: 2025-03-17

Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable CODESYS Forge talk (Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29

Post by jzhvymetal77 on IecVarAccessLibrary.IBaseTreeNode methon CODESYS Forge talk (Post)
I had this code working in a previous version of CoDeSys to read variables from a GVL that were added to the Symbol configuration. The problem now is that when I get the _IBaseTreeNode_Parent, it returns a valid interface, but none of the methods or properties work. If you monitor the _IBaseTreeNode in the watch window, it does show the correct child count. However, it fails at step 30, where the child count incorrectly returns zero. In the image, you can see that the watch window displays the correct value that the property should return. Attached is the full project code. FUNCTION_BLOCK Symbols_TO_STR VAR_INPUT i_sPath : STRING(255); i_diIndexChild : DINT; i_diIndexComponent : DINT; END_VAR VAR_OUTPUT q_diChildCount : DINT; q_diComponentCount : DINT; q_sName : STRING(255); q_sValue : STRING(255); q_sType : STRING(80); q_sErrorResult : STRING(80); END_VAR VAR uiStepCopy : UINT; uiStep : UINT; uiStepProcessCopy : UINT; uiStepProcess : UINT; _IBase : IecVarAccessLibrary.IBase; _pIIecVarAccess5 : POINTER TO IecVarAccessLibrary.IIecVarAccess5; _IIecVarAccess5 : IecVarAccessLibrary.IIecVarAccess5; _RTS_IEC_RESULT : IecVarAccessLibrary.RTS_IEC_RESULT; _udiResult : UDINT; _VariableInformationStruct : IecVarAccessLibrary.VariableInformationStruct; _IBaseTreeNode_Parent : IecVarAccessLibrary.IBaseTreeNode; _IBaseTreeNode_Child : IecVarAccessLibrary.IBaseTreeNode; _ITypeDesc_Child : IecVarAccessLibrary.ITypeDesc; _TypeDescAsUnion_Child : IecVarAccessLibrary.TypeDescAsUnion; _arIBaseTreeNode_Child : ARRAY[0..20] OF IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Child : IecVarAccessLibrary.IBaseLibrary.TypeClass; _psSymbolName_Child : POINTER TO STRING; _sSymbolName_Child : STRING(255); _IBaseTreeNode_Component : REFERENCE TO IecVarAccessLibrary.IBaseTreeNode; _TypeClass_Component : IecVarAccessLibrary.IBaseLibrary.TypeClass; _ByteAddress_Component : __XWORD; _ByteOffset_Component : __XWORD; _sArrayIndexName_Component : STRING(20); _diArrayIndexCalc_Component : DINT; _diArrayIndexValue_Component: DINT; _psSymbolName_Component : POINTER TO STRING; _sSymbolName_Component : STRING(255); END_VAR uiStepCopy:=uiStep; uiStepProcessCopy:=uiStepProcess; CASE uiStep OF 10: // GET IBASE FROM CURRENT APP _IBase:= IecVarAccessLibrary.IecVarAccGetFirstInterface2(0); IF _IBase<>0 THEN uiStep:=20; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IecVarAccGetFirstInterface2'); uiStep:=9000; END_IF 20: //QueryInterface IIecVarAccess5 from IBASE _pIIecVarAccess5 := _IBase.QueryInterface(IecVarAccessLibrary.ITFID_IIecVarAccess5, ADR(_RTS_IEC_RESULT)); IF _pIIecVarAccess5<>0 AND _RTS_IEC_RESULT=0 THEN _IIecVarAccess5 := _pIIecVarAccess5^; uiStep:=30; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': QueryInterface_IIecVarAccess5'); uiStep:=9000; END_IF 30: // Get IBaseTreeNode_Parent _IBaseTreeNode_Parent := _IIecVarAccess5.VarAccGetNode3(ADR(i_sPath), ADR(_VariableInformationStruct), ADR(_RTS_IEC_RESULT)); IF _IBaseTreeNode_Parent<>0 AND _RTS_IEC_RESULT=0 THEN q_diChildCount:=_IBaseTreeNode_Parent.ChildCount; uiStep:=40; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF 40: // Get IBaseTreeNod_Child IF(q_diChildCount-1>=i_diIndexChild AND i_diIndexChild >=0) THEN _IBaseTreeNode_Child := _IBaseTreeNode_Parent.GetChild(i_diIndexChild); IF _IBaseTreeNode_Child<>0 THEN uiStep:=50; ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': IBaseTreeNode_Parent'); uiStep:=9000; END_IF ELSE q_sErrorResult:=CONCAT(UINT_TO_STRING(uiStep), ': i_diIndexChild OutBounds'); uiStep:=9000; END_IF
Last updated: 2025-08-20

Post by spiessli on Raspberry Pi 4 with Legacy Drivers and Codesys 3.5.19 Patch 4 CODESYS Forge talk (Post)
Thanks for the suggestion, I have tried it eagerly: I have updated all packages to latest version with Codesys Installer and installed newest runtime and gateway on Raspberry Pi. Unfortunately, the error is still there. As soon as I add the SM_Drive_Servo to the device tree, I get the error below when generating the code. Reverting SM3_Basic to version 4.14 makes the error disappear. ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0032: Typ 'Unbekannter Typ: 'ConfigGetParameterValueLREAL(pParam, 0)'' kann nicht in Typ 'LREAL' konvertiert werden [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0046: Bezeichner 'ConfigGetParameterValueLREAL' nicht definiert [FEHLER] sm3_drive_servo, 4.10.0.0 (codesys): GetStandardConfigParams [AXIS_REF_SERVO]: C0035: Programmname, Funktion oder Funktionsbausteinstanz an Stelle von 'ConfigGetParameterValueLREAL' erwartet Übersetzung abgeschlossen -- 15 Fehler, 0 Warnungen : Kein Download möglich
Last updated: 2023-12-20

Post by ara32 on CODESYS 4 Linux: CODESYS Forge talk (Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22

Post by mariusz997 on Visualisation - internal error CODESYS Forge talk (Post)
Hi everyone. I try to reach Codesys but I have problem on the beginning. I use Codesys 3.5.18.60 and 3.5.18.30 . On both version I have this same problem - when I create new standard project with controller Control Win v3 x64, empty PLC program - I compile it and everything is ok. But when I add visualisation without any elements and compile it - I get: ~~~ ------ Build started: Application: Device.Application ------- Typify code... Generate code... Generate global initializations... [WARNING] SortingStation: HMI Device: PLC Logic: Application: Missing element configuration. Element may not be usable. [WARNING] SortingStation: fbOutletConveyour Device: PLC Logic: Application: C0196: Implicit conversion from unsigned Type 'WORD' to signed Type 'INT' : Possible change of sign [ERROR] Internal error:System.NullReferenceException: Odwołanie do obiektu nie zostało ustawione na wystąpienie obiektu (in english: Object reference not set to an instance of an object.). w _3S.CoDeSys.Codex86_64.V351500.CPUx86_64.CodeStore(TypeClass tc, Register RegBase, Register RegIndex, Int32 nOffset, Register RegSrc, Int32 nScale) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.GenerateVarAbsolut(IVariableExpression varexp, Int32 iArea, Int32 nAddress, IIndexInfo indexinfo, ICompiledType ctype, Int32 nTypeSize, IAccessMode am) w ..(_IVariableExpression ) w ..(IExprement ) w ..(IExprement ) w ..(_ICompoAccessExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IAssignmentExpression assign) w ..(_IAssignmentExpression ) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(IExpressionStatement expstat) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ISequenceStatement seq) w ..(IExprement ) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, ISequenceStatement mainRoutine, Boolean bKeepCompileInformation, IEnumerable`1 subroutines) w _3S.CoDeSys.Codex86_64.V351500.Codex86_64_V351500.Generate(ICompiledPOU cpou, Boolean bKeepCompileInformation) w ..(_ICompiledPOU ) w _3S.CoDeSys.Compiler35180.Phase5_Codegeneration.Codegeneration.(_ICompiledPOU , _ISignature ) w ..(_ICompiledPOU , Boolean , Boolean , _ICompileContext , _ICompileContext , Boolean , Codegeneration , Boolean& , Boolean , Boolean ) w ..(Boolean , Boolean , _ICompileContext , _ICompileContext , InitExitSignatureInfo , Boolean , Codegeneration , _ISignature , Boolean& , Boolean , Boolean ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature , InitExitSignatureInfo& , Boolean& ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(Codegeneration , _ISignature ) w _3S.CoDeSys.Compiler35180.CompilerPhases.CompilerPhase5_Codegenerator.(ICodegenerator ) w ..() w ..() Build complete -- 1 errors, 2 warnings : No download possible ~~~ Could someone help me with this problem? Thank you in advance Mariusz
Last updated: 2025-11-11

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection CODESYS Forge talk (Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27

Post by ofey on Modbus TCP communication CODESYS Forge talk (Post)
Hi! I tried setting up the PLC I'm working with (Beijer GN-9373) to connect to a modbus master running on a laptop. I have an ethernet connection (via USB-C to ethernet) between the laptop and the controller. I have tried following tutorial on how to set this up. I have added an ethernet device with the IP-address of the PLC. Further I added a ModbusTCP_Slave_Device with default settings. I get the error "Failed to open TCP Port: 1" when I try to go online with the PLC. Earlier I tested the exact same set up with the soft PLC from codesys. I can then read/write values correctly with the Modbus master i have running on the laptop. Hope anybody can help me with this, thanks in advance!
Last updated: 2023-10-06

Post by matthew on New Ladder Editor Issues CODESYS Forge talk (Post)
Hi There, When using the new ladder editor there is no option for function blocks to Remove uncalled FB call parameters. I also see no update function block. When you double click the function block it no longer opens the function block. I also now get warnings if I insert FB call without a contact in front. Warning is: (Impl)): C0373: Expression or part of it has no effect I take it the new editor must work differently? The only reason for using new ladder editor is the ST execute/block editing is far better, If you have alot of text in the old ST execute the editor window is very small and when online it's even worse. The new ST block seems a lot better Thanks!
Last updated: 2023-10-10

Post by simotion on Pointer to Softmotion axis CODESYS Forge talk (Post)
In my projet I use Softmotion. There are several Softmotion axis (type SM_Drive_Virtual). In the Global Variable List I have an array of pointers to the adress of the Axis. Axis : ARRAY[1..iMaxCntAxes] OF POINTER TO AXIS_REF_SM3 := ADR(AX01_Axis), // [1 ADR(AX02_Axis), // [2] This works, but when compiling I get the message : . [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX01_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. [WARNING] E3D: GVL Device: PLC Logic: Application: C0564: A reference to uninitialized variable AX02_Axis is used for initialization of Axis. Accessing the uninitialized variable may result in unexpected behavior. Is there a way when initializing to force the hardware (softmotion axis) to first initialize and then the Global Variable List?
Last updated: 2023-10-25

Post by grant32 on Codesys ARTI .XML file not creating but working. CODESYS Forge talk (Post)
Hello, I am working on a project with a Beijer Nexto Xpress. I have done this a few times with no issues but for some reason this time when creating a Symbol Configuration the ARTI .xml file is not being created in the Project Folder. However when manually putting the ARTI tags in the HMI program they are connected and work. So I am just not getting the file to import all the tags. I can do it manually which is fine but no matter where the project folder is saved this occurs. Anyone experienced this? Did not see another forum on it.
Last updated: 2023-10-27

Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug? CODESYS Forge talk (Post)
I'm getting closer to the error. The combination of STRUCT and ARRAY probably causes the strange behavior. As soon as the ARRAY is followed by a variable, the problem arises. Examples: X: ARRAY[1..2] OF INT; // okay Y: ARRAY[1..2] OF STRUCT; // problem Z: STRUCT; Z.ArrayOfInt[1]; // okay Z.ArrayOfStruct[1].Variable // problem // *update - array of array also causes the error A: ARRAY[1..2] OF ARRAY[1..4] OF BOOL; // problem I can't be the only one who has this problem. Or? Maybe there is a solution. Anyone? Or is it a bug after all?
Last updated: 2023-11-17

Post by felipemsgarcia on Edge Gateway online, but PLC is not online CODESYS Forge talk (Post)
Hello, Up until yesterday (2023/11/20) I was able to connect to the PLC remotely with no issues through Edge Gateway. However, today I can see the Edge Gateway online but I can find the PLC even if I do a network scan. Following the same path as janber0206 @ https://forge.codesys.com/forge/talk/automation_server/thread/e78b11d7e9/, I looked into certificates and found that one of the Trusted publisher certificates has expired earlier today (2023/11/21). Please see image. Questions are: Does it affect the connection to the PLC through Edge Gateway? How do I fix it? Thank you very much in advance!
Last updated: 2023-11-21

Post by appling on License status of Linux 64Bit runtime via CLI CODESYS Forge talk (Post)
Hi, I have a Linux 64Bit system with a Codesys application running on it. It stops after 2hours and a few minutes, which makes me think something is wrong with the installed license. (in my last timing it stopped after 2h4min, on the codesys website it is stated that runtimes without a license stop after 2h) I installed the license via a USB license dongle that I activated on my workstation with the Codesys IDE a while ago. Now the system is shipped at not accessible physically, only remotely via SSH. So is there a way to check the status of the License of the Codesys runtime when it is running on the system? Running the codesyscontrol script with "status" just tells me that it is running, but does not provide any license information. Best regards
Last updated: 2023-12-04

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop “CODESYS Control Win V3 - x64" net start “CODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02

Post by naks on Change IP address from IEC code CODESYS Forge talk (Post)
Hi, I'm working with wago 750-8212 controller. I want to change the IP address of the Ethernet adapter from webvisu. I have read some other threads in this forum and I have tried the following: Added the following text to the config file CODESYSControl.cfg: [SysSocket] Adapter.0.Name="br1" Adapter.0.EnableSetIpAndMask=1 Used the below code : IF xUpdateEthernet THEN Ethernet.Enable := FALSE; Reconfig ( xExecute := TRUE, itfNode := Ethernet, eError => ErrorReconfig, xBusy => xBusy, xDone => xDone, xError => xErrorReconfigure); IF Reconfig.xDone THEN ErrorCode := Ethernet.UpdateConfiguredIPSettings(IpAddress := NewIp, gateway := newGateway, subnetmask := newSubnetmask); END_IF IF Reconfig.xDone OR Reconfig.xError THEN reconfig(xExecute := FALSE); END_IF Ethernet.Enable := TRUE; Reconfig(xExecute := TRUE, itfNode := Ethernet ); END_IF I could change the IP address but when i restart my Controller then the IP address resets to the original, Is there anything I have missed, what else can i try ? Thank you in advance.
Last updated: 2024-07-08

Post by hyys12 on How to use/create SOTU in LD program CODESYS Forge talk (Post)
I am trying to make a LD program for an existing installation with a motor. Here an inductive sensor is used to give an input, as a check to verify the conveyor is actually running. Here the plan was to use a TOF timer which gets constantly reset when the sensor input gets detected. The problem is, that if the conveyor is stuck, and the sensor sends a continous signal, the timer will never do what it is supposed to do. Therefor I need some help on how I can convert the input to a pulse, with the help of something like a SOTU. I just cannot find this in codesys anywhere.
Last updated: 2024-07-11

Post by nico-hefr on Python script command for "Access Control" CODESYS Forge talk (Post)
Hi everyone, I use Python Script to generate some POU in Codesys V3.5 SP19 and I would like to limit the "Access Control" to them thanks to the Python command. Is there any commands that allow to edit the "Properties... >> Access Control" of the POU? The other possibility is to set the permissions with "Project >> User Management >> Permissions... >> Project objects >> Modify >> ... >> myPOU", but I did not find the related Python commands. Otherwise, is there a global setting that allows to set the permissions by default? For example, Modify = Denied for everyone user by default. Thank you in advance for your help, Nico
Last updated: 2024-07-18

Post by peterned on Programatically restart Codesys OPC UA server? CODESYS Forge talk (Post)
Hi, I'm using a Festo Codesys PLC (CPX-CEC-C1-V3), which is connected to a HMI panel. Both exchange data via OPC UA. Occasionally, the HMI stops displaying data, and looks as if there is no connection. If the HMI stops, the only way to make it work again is to restart the PLC. Restarting HMI has no effect. When the PLC is restarted, HMI starts working normally again. Is it possible to restart the OPC UA server from PLC code? I hope this will make fixing the HMI possible without a PLC restart. Thanks
Last updated: 2024-07-19

Post by mubeta on Reset problem with CMZ SD/SVM drive CODESYS Forge talk (Post)
In a recent project with SoftMotion 4.15.0.0, where I integrated two SD drives from CMZ (from catalogue EDS and not imported), on CANopen bus, I found that the SoftMotion MC_Reset function does not reset the drive faults. Even if the drive is in fault, either on the device or on the drive at the CoDeSys level, the function does not reset, instead reporting the error code: no error to reset. Finally, I had to connect the reset bit of the ControlWord directly to a tag in my program. Something I never had to do on other drives: Lexium, etc. all reset simply with MC_Reset.
Last updated: 2024-07-24

Post by paulpotat on Exclude traces when searching with ctrl+F CODESYS Forge talk (Post)
Hello, I was wondering if there is a way in codesys to exclude the traces from the search when using the "ctrl+F" window ? That would be nice to improve the search functionnality when looking for a specific variable. Sometimes when I iterate through all occurences with the "find next" button, it opens the trace configuration window. I would expect to be able to close it and go to the next occurence with the "find next" button, but after closing the trace configuration window the search says it has reached the end of the scope (even if in reality there are other occurences of the variable elsewhere). I tried to enable / disable the "search up" checkbox but it's not changing anything. I hope somebody have insight on this, BR
Last updated: 2024-08-06

Post by trusty-squire on parker servo and position CODESYS Forge talk (Post)
@gepert, When you say "I do not turn off power", are you saying you don't power off the drive, or you don't turn of the MC_POWER function block? I read your statement as you don't kill actual electrical power. MC_POWER should stay enabled. @Gustavo, not related to problem at all, but when you say 1.6 Nm is only enough torque to unscrew a loose bottle cap, I think that's a bit low. A quick mental math I use is 1 Nm is almost the same force as 1kG applied to a 10cm wrench. So 1.6kG applied to a 10cm wrench is still not a huge force, but more than enough to be felt if trying to turn the shaft by hand.
Last updated: 2024-08-06

Post by micik on Download EtherCAT project on SoftPLC (ControlWin-V3 x64) CODESYS Forge talk (Post)
Hello, I have almost exactly problem already discussed here in this old thread: https://forge.codesys.com/forge/talk/Engineering/thread/03af9426eb/ However, this is quite old and I assume not completely relevant. In my case, I use v3.5.20 on windows 11, so Winpcap is no longer supported on newer OS. Also, this hint about adding entry to the .cfg file under ProgramFiles(x86) is also not relevant anymore. I guess, I need to add entry SysEthernet to this .cfg file: C:\ProgramData\CODESYS\CODESYSControlWinV3x64...\CODESYSControl.cfg like this one: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows Component.8=SysEthernet But I'm not sure about Npcap vs WinpCap. Please, if applicable, update these instructions.
Last updated: 2024-08-08

<< < 1 .. 180 181 182 183 184 .. 190 > >> (Page 182 of 190)

Showing results of 4733

Sort by relevance or date