Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I checked it using the very same docker container version like colleague moon and the command returned root@nt0001c02c5533:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. Result: 0 CmContainer(s) listed. (CodeMeter not running) Please consider that we intend to license a codesys ARM64 SL in a docker container.
Last updated: 2024-03-20

Post by ara32 on CODESYS 4 Linux: CODESYS Forge talk (Post)
Hello! I managed to correctly launch CODESYS Developer Studio 3.5.17, almost all functionality works. The only issue remaining is that when connecting to a device and obtaining its public key, the NCryptEncrypt function is called, which is not fully implemented in the DLL source code, resulting in the connection not being established. Currently, the code of this function in the Wine repository looks like this: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG || flags & NCRYPT_PAD_OAEP_FLAG) { FIXME("No padding and oaep padding not supported\n"); return NTE_NOT_SUPPORTED; } if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } The program crashes due to the NCRYPT_PAD_OAEP_FLAG flag. I'm not proficient in C++, but I attempted to add handling myself, and here's the result: SECURITY_STATUS WINAPI NCryptEncrypt(NCRYPT_KEY_HANDLE key, BYTE *input, DWORD insize, void *padding, BYTE *output, DWORD outsize, DWORD *result, DWORD flags) { struct object *key_object = (struct object *)key; TRACE("(%#Ix, %p, %lu, %p, %p, %lu, %p, %#lx)\n", key, input, insize, padding, output, outsize, result, flags); if (flags & ~(NCRYPT_NO_PADDING_FLAG | NCRYPT_PAD_OAEP_FLAG | NCRYPT_PAD_PKCS1_FLAG | NCRYPT_SILENT_FLAG)) { FIXME("Flags %lx not supported\n", flags); return NTE_BAD_FLAGS; } if (flags & NCRYPT_NO_PADDING_FLAG) { FIXME("No padding not supported\n"); return NTE_NOT_SUPPORTED; } BCRYPT_OAEP_PADDING_INFO oaepInfo = { 0 }; oaepInfo.pszAlgId = BCRYPT_SHA1_ALGORITHM; NTSTATUS status = BCryptEncrypt(key_object->key.bcrypt_key, input, insize, &oaepInfo, NULL, 0, output, outsize, result, flags); if (key_object->type != KEY) return NTE_INVALID_HANDLE; return map_ntstatus(BCryptEncrypt(key_object->key.bcrypt_key, input, insize, padding, NULL, 0, output, outsize, result, flags)); } Now, when calling the connection, it crashes with the error "bcrypt:BCryptEncrypt flags 0x4 not implemented." Can anyone help with enhancing this functionality or at least point me in the right direction?
Last updated: 2024-03-22

Post by mimodia1 on I do not have any reedings in RUN MODE from MPU6050........ CODESYS Forge talk (Post)
Good morning, mecke96. Exactly the same thing happens to me, although I have not done the part of executing a .py file. It only reads the temperature and the counter, but the other values are zero as in your image "no readings". I have tested the MPU6050 device on an Arduino and it works. Could you tell me if you solved it?
Last updated: 2024-03-29

Post by amy123 on Alarm Manager Project Doesn't Open Successfully CODESYS Forge talk (Post)
Hello, when I download AlarmManager.project from https://forge.codesys.com/prj/codesys-example/alarm-manager/home/Home/, it gives an error when I open it. If I ignore the warning and continue to open, the alarms are missing. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: first at _3S.CoDeSys.ControlsContrib.Utilities.WeakMulticastDelegate.Invoke(Object[] args) at _3S.CoDeSys.ControlsContrib.Controls.WizardControl.OnFinishClick(EventArgs e) at System.Windows.Forms.Control.OnClick(EventArgs e) at System.Windows.Forms.Button.OnMouseUp(MouseEventArgs mevent) at System.Windows.Forms.Control.WmMouseUp(Message& m, MouseButtons button, Int32 clicks) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.ButtonBase.WndProc(Message& m) at System.Windows.Forms.Button.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam)
Last updated: 2024-04-04

Post by food on Beaglebone Black OPC-UA Server CODESYS Forge talk (Post)
Man, this was a long time ago. I think the problem probably stemmed from not loading the certificates from the client and the server on the server and client respectively in the correct manner. I believe I ended up getting around it just by removing all security on the server. In the end we did not move forward with that architecture so I never had to actually fix it.
Last updated: 2024-04-10

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, When I try to install my codesys program with the new application-based licensing, I have an error "it exceeds the scope of the license agreement. See Device > Licensed Software Metrics" In the Licensed Software Metrics section, I see a code size < 3MB and less than 2700 variables in visualiaztions. I'm using a license "Control Basic L" with "Codesys Visualization L" option, so it should be enough with these metrics. What can I do ?
Last updated: 2024-04-22

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, I tried with another project, using codesys SP20 with the latest visualization installed, I can install the application on my device but it doesn't work I get an exception "invalid license metrics" and the app won't run See attached the metrics in project and allowed by license, and the logs What am I supposed to do ? Everything is in the newest version and the values are lower than allowed and nothing works...
Last updated: 2024-04-26

Post by gseidel on Discontinuity of A/B/C axis movement. CODESYS Forge talk (Post)
Hi jonasz, you already solved it, I'm answering here for the sake of others with a similar question. You can provide the slope of the A/B/C axis with the U/V/W word. See example 3 here: https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_cnc_din66025_additional_axis.html If you don't want to change the G-Code, the function block SMC_RecomputeABCSlopes can compute the slopes automatically. https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_POUs/SoftMotion-CNC/SoftMotion-Function-Blocks/SMC_RecomputeABCSlopes.html Best regards, Georg
Last updated: 2024-04-30

Post by tomas111 on OPC UA Client API CODESYS Forge talk (Post)
I ran into a problem. Uploaded an example (https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html) After launch. on the emulator. I see that I am having problems: - UaExpert does not connect. There are many servers but no connection. - I can’t transfer the certificate from quarantine to trusted ones. There is some problem with creating the certificate. CS 19.2. If anyone has had similar problems, please give me advice. Thank you.
Last updated: 2024-05-20

Post by yofi on Raspberry Pi 4 POU not running CODESYS Forge talk (Post)
I have this error where the pou doesn't run even for simple programs like contact and a coil if i remove the pou from the task and put another one it works for one run then it stops working again in the photo we can see a contact is on but the coil connected to it is still not on and the device is in run mode I had this issue again and again any help
Last updated: 2024-06-02

Post by yofi on Raspberry Pi 4 POU not running CODESYS Forge talk (Post)
I have this error where the pou doesn't run even for simple programs like contact and a coil if i remove the pou from the task and put another one it works for one run then it stops working again in the photo we can see a contact is on but the coil connected to it is still not on and the device is in run mode I had this issue again and again any help
Last updated: 2024-06-02

Post by arcadium on TargetVisu element stacking on top of each other CODESYS Forge talk (Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17

Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state? CODESYS Forge talk (Post)
Just to share, for those who as me are seeking for this and had found no information anywhere in this World: Every time I stop/start the PLC runtime ( turning into 'Stopped' or 'Running' state ) the 'CODESYSControlService' appears at the Taskmanager list, which could suggest a straight correlation. I was expecting a clever solution, but this one solves for while.
Last updated: 2024-07-02

Post by schweizer on Position und Größe optimal anpassen (Container.Height - Visu.Height) funktioniert nicht. CODESYS Forge talk (Post)
Hello forum Does anyone have experience with optimally adjusting the position and size of the visualization elements? For us, the adjustment on the x-axis works in Codesys 3.5 SP20 with (Container.Width - Visu.Width). However, the y-axis is not affected with (Container.Height - Visu.Height). We implemented this according to the example from Codesys "Optimally adjust position and size" and had no success. Thank you very much for your help.
Last updated: 2024-07-29

Post by pietrobalint on Retain / Persistent Variables in Codesys for Raspberry Pi CODESYS Forge talk (Post)
Hi micik, I am not sure I am using well the code, because I checked the directory and there is no retains.ret file. Now I deleted the code from my project and the values are still works as persistant variables after ssh reboot it seems to me they retain as their previous value. So I am a bit confused, maybe 4.12.0.0 Raspberry Pi SL solved the persitent variable problem...
Last updated: 2024-08-20

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by taqamert on IFM-Sensor ADC READ CODESYS Forge talk (Post)
I have a pressure sensor that measures 0-600 bar and outputs a 0-5V signal, but my PLC reads analog inputs in the 0-10V range and displays a value of 1024 when 10V is applied. In this case, when the sensor outputs 5V at 600 bar, the PLC shows a value of 512. My working range is 0-350 bar, which means the PLC only uses 298 bits in this range, significantly reducing the resolution. What can I do to achieve better resolution within the 0-350 bar range?
Last updated: 2024-08-23

Post by paulpotat on cm4 runtime problem CODESYS Forge talk (Post)
Hello again, After looking into it, I noticed that the release note of "CODESYS Control for Raspberry PI 4.13.0.0" mentions a bug fix titled "Support Compute module 4". Is it possible to have more details about this fix from the CodeSys team please ? Because I have several CM4 boards with the same hardware revision / OS but some of them works with the 4.10 runtime and others only works with the 4.13 runtime...
Last updated: 2024-09-09

Post by jinlee on Camera RTSP Feed CODESYS Forge talk (Post)
Hi, I followed your guidance and used go2rtc. There is a link generated from go2rtc I can copy into the web browser element in the visualisation. It somehow only appear within the software when it is running, but not on the webvisu. I want to display the camera feed onto the webvisu. My camera is reolink 810a which supports IP protocol. My project is pretty simple, just a web browser element with assigned URL.
Last updated: 2024-09-17

Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time CODESYS Forge talk (Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27

Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time CODESYS Forge talk (Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27

Post by totorovic on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? I don't have the answer to this question. One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task Yes. It was the exeption you can see in attached file.
Last updated: 2024-10-03

Post by sebastianrapi on Bibliothek: floatingpointutils CODESYS Forge talk (Post)
Hallo Zusammen, ich versuche die Bibliothek FloatingPointUtils.compiled-library-v3 zu benutzen. leider kommt dabei folgende Fehlermeldung: Kein Quellcode für dieses Objekt... (siehe Anhang) Wie kann ich diese Bib einbinden? Kann ich diese irgendwo herunterladen? Mein Ziel ist es ein DWORD (float) in ein REAL umzuwandeln. ICh hoffe, dass ich dies mit der Funktion HexStrToReal machen kann. So wie hier: https://gregstoll.com/~gregstoll/floattohex/ convert to float... Oder gibt es bei Codesys einen anderen Weg? Ich verwende v3.5 SP20 Patch 1 + (32Bit) Grüße Sebastian
Last updated: 2024-10-17

Post by vincentger on using ADS1115 CODESYS Forge talk (Post)
Any reason the ADS1115 wouldnt work with SP20.1 and Runtime 10.0.0.0 on the Raspberry Pi . Using Bullseye or Buster i run into the same issue: Libary and integration works in general as described above BUT i am seeing "bleeding" between the analog inputs . Specifically consecutive ones: So sometimes the raw from AI1 shows on AI2, AI2 on AI3, .. AI4 on AI1. Even with filtering i cant smoothen that out properly and i feel like something is wrong. Almost like the bus is stumbling over itself, or the request from Codesys to the device.
Last updated: 2024-10-28