Search talk: -128到127是什么数据类型

 
<< < 1 .. 185 186 187 188 189 .. 905 > >> (Page 187 of 905)

Post by nz-dave on MC_HOMING CODESYS Forge talk (Post)
also get this error in place of the other from time to time.
Last updated: 2025-04-04

MC_HOMING CODESYS Forge talk (Thread)
MC_HOMING
Last updated: 2025-04-04

Post by pernockham on How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Post)
Using Codesys runtime for Linux and thinking of the process of preparing multiple such systems for my customer. I don't necessarily have physical access to these units, they can be (very) remote. The idea so far is to use an image to install the Linux OS and codesys runtime. Application updates can be done by distribution of the PlcLogic/Application/application.app and application.crc files. But whats the most practical way of managing the license for these units? Do each controller need to be physically connected to a License Manager instance or can licenses be distributed by means of a license file for each unit? I believe that the license should be stored in soft containers for each unit. Help and insights appreciated! Per
Last updated: 2025-04-04

Dynamic limits invaild CODESYS Forge talk (Thread)
Dynamic limits invaild
Last updated: 2025-04-04

Post by jbu0105 on Dynamic limits invaild CODESYS Forge talk (Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04

Post by jbu0105 on Dynamic limits invaild CODESYS Forge talk (Post)
Hello, For my delta robot i wil use the MC_MoveCirvularAbslolute function. Every time that i set the execute of this function has my Axis group a error. Thats is: The dynamic limits for the movement are invalid. What can i do that this error go away? I saw a view funcitons with limit dymanics but i don't now how they work. If i use the function MC_MoveLinearAbsolute than i have no error. Does anyone know how i fix this?
Last updated: 2025-04-04

Post by r-c-r on SM3RaspiStepper 0.0.0.6 issue CODESYS Forge talk (Post)
Ok, so i made some tests in the meantime and i have some conclusions. It apears that the enable bit is activated only when a motion function is executed. I implemented a very simple program with MC_Power and MC_Jog. If i enable everything on MC_Power, the enable GPIO pin stays off. However, as soon as the MC_Jog function is used the enable GPIO pin turns ON and remains ON. In version 0.0.0.4 this is not happening. The GPIO enable pin turns on or off when the MC_Power is enabled or disabled. From this behaviour i understand that in version 0.0.0.6 the GPIO enable bit is activated together with pulse and dir pins when motion starts. When motion stops, enable bit remains with the last state (on in this case) and you cannot turn it off for example. For me this bit is useful because i can turn on and off the stepper drive with MC_Power function. Now i can turn it on, but never off.
Last updated: 2025-04-04

Attaching Trace variable to Frame Configuration Variable CODESYS Forge talk (Thread)
Attaching Trace variable to Frame Configuration Variable
Last updated: 2025-04-04

Post by kevinm on Attaching Trace variable to Frame Configuration Variable CODESYS Forge talk (Post)
Is it possible to show a variable from a Frame Configuration in a Trace on that Visualization? I want to pass the FB for an AXIS_REF_ETC_SoE_Standard to the visualization and display live axis data in the visualization. However, I cannot find a way to use a Frame Configuration variable in the Trace Configuration dialog.
Last updated: 2025-04-04

Post by jampid on Codesys Codebase Library Update CODESYS Forge talk (Post)
Bonjour DIEGORAMONM, très recemment,je pense avoir résolu un problème similaire en allant dans le Placeholder (Espace réservé) du Gestionnaire de bibliothèque. Dans cette nouvelle fenêtre, je sélectionne la bibliothèque qui pose problème, et dans la colonne du milieu je clic pour définir une bibliothèque de version inférieure. à la compilation, je suis passé de 484 erreurs à 0. :) J'espère que ce sera également le cas pour toi. Bon développement JM
Last updated: 2025-04-04

Codesys Codebase Library Update CODESYS Forge talk (Thread)
Codesys Codebase Library Update
Last updated: 2025-04-04

url String notation CODESYS Forge talk (Thread)
url String notation
Last updated: 2025-04-04

Post by jampid on url String notation CODESYS Forge talk (Post)
Bonjour damian177, Je pense que le problème vient du caractère dollar qu'il faudra doubler. La déclaration sans erreur est celle-ci : sURL:WSTRING(1024) := "https://mydomain.pl/api/rce-lte?$$filter=doba eq 2025-03-18"; De plus il faut bien note la chaîne entre guillemet car au dela de 255 caractères , il s'agit de WString au lieu de String. Bon développment! JM
Last updated: 2025-04-04

Post by jampid on What is the CFC editor (page oriented) "Add page" keyboard shortcut? CODESYS Forge talk (Post)
ULVIS, tu peux copier la 1ère page par exemple ou une autre CTRL+C et la recopier autant de foix que tu souhaites: CTRL+V Voici le lien pour accédre aux raccourcis du langage CFC Pages https://content.helpme-codesys.com/en/CODESYS%20CFC/_cds_edt_cfc_shortcuts.html J'espère que cela t'aidera. JM
Last updated: 2025-04-04

Post by gseidel on Dynamic limits invaild CODESYS Forge talk (Post)
Hi jbu0105, which error doe you get, exactly? Is it error 11008, SMC_MOVE_INVALID_DYNAMICS? (It might help if you check the "Log" tab in the PLC device and copy the exact error.) Please double-check whether the inputs Velocity, Acceleration, Deceleration, and Jerk of MC_MoveCircularAbsolute have correct (positive) values. Best regards, Georg
Last updated: 2025-04-07

Post by jampid on Struct Literal CODESYS Forge talk (Post)
Bonjour Davidmic, Il n'est pas possible d'associer une méthode à une fonction. Cela est possible sur les Blocs fonctions. En utilisant ta DUT MyStruct, je créé une fonction avec en entrée un tableau de structure :** FUNCTION F_F3 : REAL VAR_IN_OUT // bien définir un type IN_OUT IN_ptrINT: ARRAY[*] OF MyStruct; // la taille sera définie ultérieurement/ END_VAR VAR _di: DINT; // Index de parcours du tableau pour l'écriture dans les cases ENDVAR ============== //Programme F_F3: FOR _di := LOWER_BOUND(IN_ptrINT,1) TO UPPER_BOUND(IN_ptrINT,1) DO IN_ptrINT[_di].som:=IN_ptrINT[_di].a + IN_ptrINT[_di].b; END_FOR J'utilise ensuite cette fonction dans un POU Programme : PROGRAM Test_F_Fx VAR _aiTAB9:ARRAY[0..3] OF MyStruct := [(a := 1, b := 1.2), (a := 2, b := 2.2), (a := 3, b := 3.3), (a := 4, b := 4.4)]; END_VAR ** ==========** F_F3(IN_ptrINT:=_aiTAB9 ); Voilà l'idée pour avancer. Une autre idée, est d'utiliser les pointeurs ou les références. Bon développement!
Last updated: 2025-04-07

Post by jampid on PersistentVars and Webvisu Element CODESYS Forge talk (Post)
Bonjour, est-ce que les espaces de noms des variables sont bien indiqu dans les commutateurs ? Je viens de faire un petit essai: OK {attribute 'qualified_only'} VAR_GLOBAL PERSISTENT RETAIN xBit1: BOOL:=1; xbit2: BOOL:=1; END_VAR Déclaration de variable dans le commutateur (et aussi dans un voyant pour le test) :PersistentVars.xBit1 Bon développement!
Last updated: 2025-04-07

PersistentVars and Webvisu Element CODESYS Forge talk (Thread)
PersistentVars and Webvisu Element
Last updated: 2025-04-07

Codesys Codebase Library Update CODESYS Forge talk (Thread)
Codesys Codebase Library Update
Last updated: 2025-04-07

Struct Literal CODESYS Forge talk (Thread)
Struct Literal
Last updated: 2025-04-07

Post by jampid on Codesys Codebase Library Update CODESYS Forge talk (Post)
Bonjour Diegoramonm, Je pense avoir eu un problème similaire. Je l'ai résolu en dégradant la version de la bibliothèque qui me posait problème après également une mise à jour. Ouvrir le gestionnaire de bibliothèque / Ouvrir l'onglet Espace réservé / La fenêtre Placeholders s'ouvre. Sélectionner la bibliothèque voulue puis double cliquer sur la bibliothèque(carré jaune)concernée et choisir une autre version. puis recompiler. Pour moi cela a marché du 1er coup : chance! Bon développment!
Last updated: 2025-04-07

How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Thread)
How to manage soft container licenses for (remote) multi units?
Last updated: 2025-04-08

Post by timvh on How to manage soft container licenses for (remote) multi units? CODESYS Forge talk (Post)
You need to activate an individual license (ticket number) for each device. THe hardware of each device is unique, so you cannot copy a soft container from one device to another. This license can be installed in a local (wibu - codemeter) soft container, or you could optionally activate it on a hardware (USB) key. The benefit of the key is that you can easily move it to another device, nor does it get lost when you replace parts of the hardware of the device or completely overwrite the image. See: https://store.codesys.com/en/codesys-key.html
Last updated: 2025-04-08

Ethercat and profinet on together CODESYS Forge talk (Thread)
Ethercat and profinet on together
Last updated: 2025-04-08

Post by installwhat on Ethercat and profinet on together CODESYS Forge talk (Post)
I'm curious about the impact of having profinet and Ethercat (specifically softmotion so frame at start of task?) running together. Since it's advised to access the data from the bus task should have both profinet io and ethercat on the same task? Are there any implications around this one should be aware of especially since the frame at task start is just, so far as I'm aware, an ethercat thing? Thanks
Last updated: 2025-04-08

<< < 1 .. 185 186 187 188 189 .. 905 > >> (Page 187 of 905)