Post by timvh on Toradex and CODESYS and licensing CODESYS Forge talk (Post)
For the Virtual Control you need to use a "Network license". The Virtual Control has parameters of which one is the reference to the license server. This can be the device itself, but you need to activate the license on the host system (not in the container). For this, CODESYS has a Network License server with WBM (web based management). See for the Network License configuration: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_license_controller_linux.html If it is only for evaluation, I would advise to use a CODESYS (USB) key and activate the license on the key. Then you still have to install the CODESYS Network License server on the host, but you don't have to activate the license as soft license on the device. The benefit is that you can easily move your license to another device when needed. Off course your device must have a free USB port available to be able to do this.
Last updated: 2025-10-20

Post by eschwellinger on Toradex and CODESYS and licensing CODESYS Forge talk (Post)
yes, need to be plugged.
Last updated: 2025-10-21

Post by timvh on Errors after moving from SP18 to SP20/21 CODESYS Forge talk (Post)
have you tried: VisuElems.VisuStructClientData ?
Last updated: 2025-10-22

Post by dinesh-vamtec on SysProcessExecute CODESYS Forge talk (Post)
I'm trying to open the Help.chm file in CodeSys ST, not working.
Last updated: 2025-10-24

Post by kenth1973 on MC_Phasing state explenation CODESYS Forge talk (Post)
My MC_Phasing FB was stuck in iPhasingState=1 and error output HIGH on one axis. I could manually overwrite the state to 0 in the instance data. During normal run I see the state change from 0 to 10 to 100 back to 0 (maybe more states that I couldnt catch with the naked eye) But - what are the states numbers and their different explenations? This is not explained in the FB guide on codesys. (the pictures show state = 0 after I reset)
Last updated: 2025-11-22

Post by bertus on Can't get SMC_SmoothPath to work CODESYS Forge talk (Post)
Thanks. I will do more investigation and testing next week.
Last updated: 2026-01-02

Post by timvh on Deploy Codesys Control SL to a 'secure' device CODESYS Forge talk (Post)
Runtime version SP22 is an LTS version.
Last updated: 2026-08-10

Post by timvh on KeyPad Function in Visualization to fill a table CODESYS Forge talk (Post)
Create an array of STRING and 1 INT variable, e.g.: asMyString : ARRAY[0..9] OF STRING; iIndex : INT; Then place a "Table" object in the visualization: - link this to the string array variable. - Check the option "Use Template" - Then in the Input Configuration - add the "Write Variable" command Somewhere else add a "Combobox, array" - link this to the same array. - And link the index to the INT variable. In the Combobox, you can then select one of the strings from the array. The index variable will indicate which selection has been made.
Last updated: 2026-01-08

Post by osande on V3.5 SP22 Patch1 CODESYS Forge talk (Post)
Compilation fault according to file. Anyone. Worked fine with SP21 P5..
Last updated: 2026-05-02

Post by leag on Reset device password Festo PLC CODESYS Forge talk (Post)
Hi, I am new to CODESYS, and I want to program a new FESTO, but I am getting this authentication screen. I don't remember the password. I tried with Administrator/Administrator and some other defaults I found online but nothing works. I also tried searching for CODESYSControl_User.cfg and many other recommended directories but I dont seem to have any of them (like CODESYSControlWinV3x64) Could you please help me understand what I need to reset? Thanks a lot
Last updated: 2026-08-12

Post by nz-dave on *exception* [processorloadwatchdog] occurred in: app=[all], task=[all] CODESYS Forge talk (Post)
Can anyone shed some light on this issue im having. at random, sometimes days, sometimes weeks or months. i get this error and have to reset the plc. Im using a Weintek HMI with ethernet/ip remote io and vsd. i have tried increasing my task times and watchdogs. and when i view my PLCload in the shell its normally around 3-4%, highest ive ever seen is 7%. Nothing i do seems to help the issue. Could the HMI's Codesys CPU be getting to hot do to high ambient temp?
Last updated: 2026-02-01

Post by pernockham on Unable to deploy "Control for Linux SL 4.18.0.0" CODESYS Forge talk (Post)
Does this cover what you need?
Last updated: 2026-02-17

Post by a-simone on Unable to install previously installed version CODESYS Forge talk (Post)
Same problem, someone solved it?
Last updated: 2026-02-20

Post by sulzbrunn on Codeys Installation freezes while attempting to install packages CODESYS Forge talk (Post)
ok, after 33 minutes it contiuned - Solved
Last updated: 2026-03-19

Post by tomstix on JSON_Utilities_SL JSONFileWriter error NULL_POINTER CODESYS Forge talk (Post)
Hi, did you ever find an answer to this?
Last updated: 2026-04-09

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Hello, my PFC200 has run for a few month now without problems. But now it freezed 2 times a day. LEDs were green but the PLC was not reachable. After power off -> on. I found that the MQTT had an error: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED. And MQTT hadn't reconnect since then. I tried a cold and a warm reset but nothing helped. How can I solve this? Regards, Paul
Last updated: 2023-09-21

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by helcioburd on How long can a WSTRING be in CodeSys V3? CODESYS Forge talk (Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02

Post by ganassa on Custom colors in Ladder diagrams? CODESYS Forge talk (Post)
How can I change the default color - blue - for active lanes, contacts and coils? I'd like a lighter color. After having failed in finding a related option in the IDE, I've looked at the "Default.editortheme" file in CODESYS' directory, but couldn't see any related option. Thank you
Last updated: 2025-07-09

Post by xabier on See only variable CODESYS Forge talk (Post)
I have declarated this variable...When i use the variable I see all...I wan see only the variable not all. For example I declarated in GVL_GLOBAL ==> Torque_Mode When I push enter insert in code all rute..GVL_GLOBAL.Torque_MOde...I want see only torque mode...How is possible resolved this problem?? Thanks XABI
Last updated: 2024-03-14

Post by dmb-fan on Attemp Convert old V2.3 projects : Error HRESULT: 0x80010105 (RPC_E_SERVERFAULT)) CODESYS Forge talk (Post)
I try Sandbox. Now I get messages like "Converter is on the blacklist for this version". Online help says nothing about a too high version for the converter. How I can find out the allowed version? Or is this only for sandboxes? what a jungle !
Last updated: 2026-08-11

Post by rossanoparis on CAN TX regression in Control for Raspberry Pi 4.21.0.0 with CAN API library (RX works, TX silently fails) CODESYS Forge talk (Post)
Environment: Target: Revolution Pi (Kunbus RevPi), armv7l 32-bit OS: Raspbian GNU/Linux 9 (Stretch), kernel 4.19.95-rt38-v7 (SMP PREEMPT RT, built 2022-03-22) CAN: via SocketCAN (can0) Runtime: CODESYS Control for Raspberry Pi SL IDE: CODESYS V3.5 SP22 + patch 3 (previously V3.5 SP22 + patch 2, where everything worked with runtime 4.18.0.0) Library: CANBusAPI from the "CAN API" package, version 1.0.0.3 Summary: The setup worked correctly with V3.5 SP22 + patch 2 and runtime 4.18.0.0. After updating the IDE to SP22 + patch 3 and the runtime to 4.21.0.0, CAN transmission via the CANBusAPI library stopped working. Reception is unaffected. There are no error indications anywhere: the application runs normally and the CAN diagnosis reports a healthy bus. Systematic testing (below) shows the problem follows the runtime version, not the IDE update. Regression isolation: The same application (compiled under SP22 + patch 3, unchanged between tests) was downloaded to the same target with different runtime versions, changing only the runtime each time: 4.18.0.0: TX and RX both work 4.19.0.0: TX and RX both work 4.20.0.0: TX and RX both work 4.21.0.0: RX works, TX does not The behavior is fully reproducible in both directions (downgrading to 4.20 restores TX, upgrading to 4.21 breaks it again). Hardware, wiring, OS, project, and application code are identical across all tests. Diagnostic data (CANBusDiagnosis FB, while the application is transmitting on 4.21): ctSendCounter: incrementing normally ctTxErrorCounter: 0 ctRxErrorCounter: 0 eState: ERROR_FREE xBusAlarm: FALSE So the library accepts and counts the outgoing messages, no TX errors are reported, and the CAN controller state stays error-free, but the messages never reach the other nodes on the bus. Expected behavior: Messages sent via CANBusAPI (CANDriver / SendMessage) are transmitted on the bus, as with runtime versions up to and including 4.20.0.0. Notes: I am aware that the CAN API package (1.0.0.3, from 2016) is old; however, the regression is tied to the runtime version, since the identical binary works on 4.18-4.20. Questions: Is there a known change in CmpSocketCanDrv / CmpCAACanL2 between 4.20.0.0 and 4.21.0.0 that could affect TX via the CAN API library? Is runtime 4.21.0.0 still supported on Debian 9 Stretch (kernel 4.19, RT-patched), or is a newer OS required? If a minimum OS/kernel requirement was introduced with 4.21, is it documented?
Last updated: 2026-08-17

Post by thn-power on Updating OPC UA Core Nodeset on PLS CODESYS Forge talk (Post)
Hi After much trail and error I think I found the root cause to my OPC UA problem. The problem is that I cannot manage to build and download a program with a a custom OPC UA Information model. We use a Weidmueller WL2000 PLS, but the problem also exsist on the Win V3 PLC. Our custom information model is based on the latest versions of the OPC UA Core Nodeset v 1.05.03 (2023-09-20) and UA/DI nodeset 1.04.0 (2022-11-03) Those nodesets are installed in the Codesys Information Model Repository (3.5.19.6) However, when trying to build I get the following error. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/ is required by http://bos.org/ with a minimal publication date from 15.12.2023 but the device has only a model from 15.09.2021 installed. Probably the information model from 15.09.2021 is missing in the information model repository. [ERROR] Untitled1: Communication Manager [Device: PLC Logic: Application]: The information model http://opcfoundation.org/UA/DI/ is required by http://bos.org/ with a minimal publication date from 03.11.2022 but the device has only a model from 09.03.2021 installed. Probably the information model from 09.03.2021 is missing in the information model repository. Build complete -- 2 errors, 1 warnings : No download possible I think the problem is that the UA Core nodeset is implemented in the PLC firmware (at least that in Siemens S7), and that only includes the "old" nodeset from 2021-09-21 etc. So the question is, how (or if?) can I transfer the new nodeset to the PLS? I have created separate Information models under Communication manager with the newer code nodesets (UA and DI). But it seems that the compiler does not recognize them being excising, neither in the Codesys IDE or on the PLC. Would have guessed that this is a common issue, sine many manufacturers use the latest versions of the OPC UA standard, and that it would be a solution to the problem.
Last updated: 2024-09-20