Search talk: set two element at a time

 
<< < 1 .. 187 188 189 190 191 .. 194 > >> (Page 189 of 194)

Post by joshskellig on Publish a JSON payload via MQTT Publish (using IIot Libraries) CODESYS Forge talk (Post)
I am trying to figure out how to get a JSON payload to properly publish to my MQTT Broker. I am able to generate JSON using the examples from Codesys, but when I send that payload via MQTT there are characters that are extra or not recognized by my MQTT client. Any idea what could be causing it? PROGRAM PLC_PRG VAR hostname: STRING := 'localhost'; port: UINT := 1883; topic: WSTRING(1024) := "testing/"; payload: BYTE; factory : JSON.JSONDataFactory; eDataFactoryError : FBF.ERROR; pJsonData : POINTER TO JSON.JSONData := factory.Create(eError => eDataFactoryError); fb_JBuilder : JSON.JSONBuilder; wsValue : WSTRING := "Value1"; diRootIndex, diObject1Index : DINT; iValue : INT := 1234; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; mqttClient: MQTT.MQTTClient; mqttPublish: MQTT.MQTTPublish; mqttPublishProperties: MQTT.MQTTPublishProperties := (bPayloadFormatIndicator := 1, wsContentType := "application/json"); END_VAR // Json Functionality IF xFirst THEN fb_JBuilder(pJsonData := pJsonData, diRootObj => diRootIndex); fb_JBuilder.SetKeyWithValue("Key1", wsValue, diParentIndex := diRootIndex); diObject1Index := fb_JBuilder.SetKeyWithObject("Key2", diParentIndex := diRootIndex); fb_JBuilder.SetKeyWithValue("Key3", iValue, diParentIndex := diObject1Index); xFirst := FALSE; END_IF jsonArrayWriter(pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE); MSU.StrTrimW(pString:= ADR(wsJsonData)); // MQTT Functionality mqttClient( sHostname:=hostname, uiPort:=port, eMQTTVersion:=MQTT.MQTT_VERSION.V5 ); mqttPublish( mqttClient:=mqttClient, pbPayload:=ADR(wsJsonData), udiPayloadSize:=SIZEOF(wsJsonData), wsTopicName:=topic, mQTTPublishProperties:=mqttPublishProperties );
Last updated: 2024-04-10

Post by fontrap on cmDongle Raspberry Pi issue CODESYS Forge talk (Post)
Hello mates, I'm working with CODESYS V3.5 SP20 on a Raspberry Pi and I use "Raspberry Pi MC SL" as device on the project. I've installed the Control Standard L (multicore) license on a Wibu System usb-Dongle (cmStick/4.50) that already had another license from another vendor. I follow the online activation procedure from CODESYS documentation. Raspberry Pi has already CodeMeter installed for the other license. When I plugin the dongle on Raspberry and start the Runtime from Raspberry Pi Update in CODESYS I receive the message that I'm on Demo mode because the license is missing. I double checked that the license is activated in the dongle, through the WebAdmin of CodeMeter and the second license runs properly without any issue. I have already try to change the dongle from HID to MSD device and backward but the the Runtime cannot recognize the Dongle. I have also try to stop and start the Runtime through CODESYS without success. Is there anything else I can do to fix this issue?
Last updated: 2024-04-22

Post by kblundy on Change the Opening Position of the Dialog using VU.FbOpenDialog CODESYS Forge talk (Post)
I hope the community can help me with this. I need to use the Visu Utils FbOpenDialog to control the opening and closing of a dialog. I have the Opening and Closing working, but I can’t get the dialogue's position to be controlled. The code looks like this: PROGRAM OPEN_DIALOG VAR xOpenLatchSettingDialog : BOOL; TopLeftDialog : VisuStructPoint ; fbOpenLatchSettingsDialog : VU.FbOpenDialog ; END_VAR IF xOpenLatchSettingDialog THEN xOpenLatchSettingDialog:= FALSE ; TopLeftDialog.iX := 100; TopLeftDialog.iY := 23; fbOpenLatchSettingsDialog(sDialogName := 'visu_AlarmLatchSettings', xExecute := xOpenLatchSettingDialog , xModal := TRUE, itfClientFilter := VU.Globals.OnlyTargetVisu, pTopLeftPosition := ADR(TopLeftDialog)); CloseVisuDialog(sDialogName:= 'visu_AlarmLatchSettings'); ELSE xOpenLatchSettingDialog:= TRUE ; IF fbOpenLatchSettingsDialog.xError THEN xOpenLatchSettingDialog := FALSE; END_IF END_IF I can't seem to work out a way to make the values in TopLeftDialog.iX and TopleftDialog.iY be passed correctly in the call and for it to change the position of the dialogue box. The code is compiled, but the position has not been changed. Any guidance or suggestions for revising this code would be incredibly valuable. Your insights could be the key to solving this issue.
Last updated: 2024-05-05

Post by kaotic2499 on Upgraded Raspberry 2b to Raspberry 5, Trends Broken? CODESYS Forge talk (Post)
Hello! Raspberry pi 2b just is getting a bit slow so decided to go for a Raspberry 5. Project is now upgraded to suit Pi 64 SL... so, now although everything runs perfectly... for some reason my trends will not save! its driving me nuts... ^Tried merging tasks with main program & trends ^tried re-prioritizing tasks (shifting 1 - 31 etc) ^Recreated the Trend Recording manager from scratch ^Tried swapping persisitant vars to GVL Retains then non-retains... (Project attached is as per before trial&error) Raspberry Pi 2b still runs "perfectly" though its very chuggy (Still saves the trends, note this is of an pretty much identical project minus the device compatibility) Does anyone have any advice to offer? project attached.... I feel it could be outside of Codesys itself causing the issues, but cant see/find anything on the internet to assist (or anyone else with the same problem as me...) Can attach project in another format (non archive) any assistance is much appreciated!
Last updated: 2025-10-19

Post by cmj-icsys on Custom configure tab in device editor CODESYS Forge talk (Post)
Hi everyone, I’m developing a custom CODESYS I/O driver for my company’s device, and I’ve been studying the example projects in CODESYS V3.5 SP20 Patch 5. In the IOMappingExample.project, I noticed that EtherCAT devices provide additional configuration tabs in the Device Editor, such as General, Process Data, etc. However, for custom I/O driver examples (based on IoDrv), the Device Editor only shows the default tabs like <devicename> I/O Mapping or <devicename> Parameters.</devicename></devicename> I’d like to create custom tabs or configuration pages in the Device Editor (e.g., “General Settings”, “Communication”, etc.) to allow users to configure parameters in a more structured way. Could anyone explain: How to define and register custom tabs or UI pages in the Device Editor? What tools or SDKs are needed to create UI elements such as combo boxes or check boxes? How to bind those UI controls to device parameters defined in the XML (device description)? Any example, SDK reference, or documentation link would be really helpful. Thanks in advance!
Last updated: 2025-10-20

Post by valenting on License problem with Raspberry Pi CODESYS Forge talk (Post)
Hello, I have a raspberry pi with a license installed, but Codesys stops after 2 hours, and when I start it manually I have the following message: pszInfo=!!!! no runtime license - running in demo mode(~2 hours) I tried using License Manager, and got the following message: Licensing info not available. There is no dongle attached to the device. I have this message frequently, and usually removing the content of /var/opt/codesys/.cmact_license makes it work. After doing it and restarting Codesys, I have an empty Softcontainer without my License. I tried using "Install license" using the .WibuCmRau file for the corresponding license and got the following message: Licensing info not available. The device does not support this service. I also tried using Additional Functions > Restore Licenses with the Ticket ID and got the following message: This device does not support automatic license backup. How can I reinstall the license to this Raspberry Pi?
Last updated: 2025-11-28

Post by mil581 on Modbus TCP Server connection is ESTABLISHED but all holding registers are value 0? CODESYS Forge talk (Post)
Hello everyone! I'm facing a weird issue with CODESYS Control Win V3 x64 on a fresh Windows install. The situation is as follows: CODESYS Modbus TCP Server (Slave) is running and I can see live values in the mapping display of Modbus settings: GVL (e.g., 32, 42, 50). Port 502 is LISTENING according to netstat. When connecting via Modbus Poll or Node-RED, the connection status changes to ESTABLISHED and everything reports as fine. The Problem: Despite the successful connection, all holding registers return 0 no matter what. It's like the OS accepts the TCP handshake, the request counter goes up but the data payload never reaches Modbus Client (in this case Node-RED or Modbus Poll). Quick Stats: Firewall: Completely OFF. Unit ID: Verified & Matching. IP: Tried 127.0.0.1 and 192.168.0.1. Interface: Correctly bound in Ethernet Device settings. I already tried absolutely everything from changing IP address, subnet, port, deleting the project and starting new one and even nuking my old Windows install. Since I am near completion of my bachelor thesis only thing left for me to do is connect SoftPLC to NodeRED via Modbus but this issue is driving me crazy for weeks. I do not know what to do anymore.
Last updated: 2025-12-25

Post by tjacks on Opc UA Data Source Client Browse Error in Codesys HMI CODESYS Forge talk (Post)
Codesys V3.5 SP21 Patch 3 Codesys HMI 3.5.21.30 I'm trying to connect to an OPC UA server on a Kuka robot controller using Codesys HMI's data source manager. I get through the login phase and the client browses most of the data structure on the server but errors out toward the end with a generic: Error while browsing the client, Failed with service result: BadUnexpectedError. If I complete the data source setup and try to update variables, I get the attached stack trace for the error. I've tried several different endpoint and security options. Most get me through the login but all error out while browsing. UA Expert happily connects and browses with the same configuration. I've connected this same version of Codesys to TwinCAT OPC UA servers and Siemens PLC OPC UA servers. Any ideas on what may be causing the generic BadUnexpectedError during OPC UA server browse?
Last updated: 2025-11-17

Post by jv-certhon on Io driver Scan functionality CODESYS Forge talk (Post)
Hello, Codesys IDE is 3.5.21.30 IoDrvBase is: 3.5.17.8 I am working on implementing Codesys on our I/O product line, using the IO driver examples, and the Linux UDS socket approach. I have sucessfully created an implemetation where I have a Device with mutiple slots, on which I can plug modules. These modules represent our IO modules, and communication is successful. (For this question the assumtion can be made that Codesys commucates with 1 'master' device, which handles further communcation with the IO modules. For the next part of the question it can be assumed that the Master device has a list of which modules are attached/available) I'm now trying to implement the 'Scan for Devices...' feature, but I'm completetly lost on what to do once the IoDrvScanModules method is called in my IoDrvFB. I'm guessing that the ppConnectorList has to be filled with the found devices, but I have no idea if that is the correct approach. And Codesys is not triggering my breakpoints in the method, which makes things more difficult. I hope someone could provide some examples or guidance on what steps I should take to implement the scan feature. Thanks in advance.
Last updated: 2025-11-26

Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program? CODESYS Forge talk (Post)
Hi, I need to change the IP address of an ABB PM556-TP-ETH using ABB Automation Builder. The situation is: I have connectivity to the PLC using the current IP (configured in Communication Settings) Online Login works fine The Network Scan does not detect the PLC IP-Configuration tool shows all fields disabled I don't have the original project source, only an empty project The PLC has no SD card inserted The Online menu does not show an Upload option When I modify the IP in the project and connect, Automation Builder shows: "The PLC configuration needs to be updated. A full PLC download is required" I'm afraid a full download will overwrite the running program. Is there any way to change only the IP address without overwriting the application? I'm also open to solutions using third-party tools, Python scripts, or any other method (DCP protocol, direct TCP communication, etc.) as long as it doesn't overwrite the running application. Thank you
Last updated: 2026-05-19

Post by mohammedben on Fail communication between CODESYS and Fuxa SCADA via OPC UA CODESYS Forge talk (Post)
hi, When I try to establish communication between CODESYS and Fuxa SCADA via OPC UA, the connection fails, and I receive the following error: 2026-02-15T08:38:13.618Z [ERR] 'codesys' connect failure! Error: The connection may have been rejected by server, Err = (ClientTCP_transport6: socket has been disconnected by third party) 2026-02-15T08:38:13.619Z [ERR] 'codesys' try to connect error! Error: The connection may have been rejected by server, Err = (ClientTCP_transport6: socket has been disconnected by third party) 2026-02-15T08:38:13.622Z [ERR] 'codesys' connect error! undefined (1) Note that there are no problems when I establish communication with the UaExpert and OPC UA Client Simulator software. I also previously tried communicating with RapidSCADA and received the following error: Endpoint with the specified security options not found. And when I try to connect with "none" in the security policy, I get this error: BadSecureChannelClosed I have tried almost all the solutions available online and have not found a solution. I hope you can provide me with a solution that solves this problem. Thanks in advance
Last updated: 2026-02-16

Post by jari-koivuluoma on Problem trying Net Base Services 3.5.15.0 TCP connection CODESYS Forge talk (Post)
I have a need to send messages between 2 PLCs and I cant use network variables (because of size limit) so I tried writing this simple test program. This seems to work fine. I can send messages back and forth when a first "Start server" and then "Connect client". See the attached image. However, if I disconnect the client by setting ClientConnect to false and try to re-connect then the TCP_Client just gives me TIMEOUT error. When I stop and start the server again, then Im able to reconnect. How is this supposed to work? Why reconnecting wont work. There is not other way of disconnecting the client than setting xEnable of the TCP_Client to false. This is just a testing program and I will try it on 2 seperate devices once this works. PROGRAM PLC_PRG VAR CONSTANT mySize : UDINT := 255; END_VAR VAR Server: NBS.TCP_Server; ServerIpStr: STRING := '127.0.0.1'; ServerIP: NBS.IP_ADDR; ServerPort: UINT := 50000; ServerConnection: NBS.TCP_Connection; Client: NBS.TCP_Client; ServerRead: NBS.TCP_Read; ServerWrite: NBS.TCP_Write; ServerSend: STRING(mySize); ServerReceive: STRING(mySize); ServerConnect: BOOL; bServerSend: BOOL; IP: NBS.INADDR; ConnectedClientIP: STRING; ClientPort: UINT := 50000; ClientIpStr: STRING := '192.168.1.49'; ClientIP: NBS.IP_ADDR; ClientRead: NBS.TCP_Read; ClientWrite: NBS.TCP_Write; ClientSend: STRING(mySize); ClientReceive: STRING(mySize); ClientConnect: BOOL; bClientSend: BOOL; Error: BOOL; Message: BOOL; END_VAR // Server ServerIP.sAddr := ServerIpStr; Server( ipAddr := ServerIP, uiPort := ServerPort ); ServerConnection( xEnable := Server.xEnable, hServer := Server.hServer, ); IP := ServerConnection.IPAddress; ConnectedClientIP := F_Concat7( BYTE_TO_STRING(IP.S_un_b.s_b1),'.', BYTE_TO_STRING(IP.S_un_b.s_b2),'.', BYTE_TO_STRING(IP.S_un_b.s_b3),'.', BYTE_TO_STRING(IP.S_un_b.s_b4)); ServerRead( xEnable := ServerConnection.xActive, hConnection := ServerConnection.hConnection, szSize := SIZEOF(ServerReceive), pData := ADR(ServerReceive) ); IF ServerRead.xReady AND ServerRead.szCount > 0 THEN Message := TRUE; END_IF IF ServerRead.eError > 0 THEN Error := TRUE; END_IF ServerWrite( xExecute := ServerConnection.xActive AND bServerSend, hConnection := ServerConnection.hConnection, szSize := LEN(ServerSend)+1, pData := ADR(ServerSend) ); IF ServerWrite.xDone THEN bServerSend := FALSE; END_IF IF ServerWrite.eError > 0 THEN Error := TRUE; END_IF // Client ClientIP.sAddr := ClientIpStr; Client( xEnable := ClientConnect, ipAddr := ClientIP, uiPort := ServerPort, udiTimeOut := 10000000 ); ClientRead( xEnable := Client.xActive, hConnection := Client.hConnection, szSize := SIZEOF(ClientReceive), pData := ADR(ClientReceive) ); IF ClientRead.xReady AND ClientRead.szCount > 0 THEN Message := TRUE; END_IF IF ClientRead.eError > 0 THEN Error := TRUE; END_IF ClientWrite( xExecute := Client.xActive AND bClientSend, hConnection := Client.hConnection, szSize := LEN(ClientSend)+1, pData := ADR(ClientSend) ); IF ClientWrite.xDone THEN bClientSend := FALSE; END_IF IF ClientWrite.eError > 0 THEN Error := TRUE; END_IF
Last updated: 2024-10-03

Post by bschraud on runtime received SIGABRT CODESYS Forge talk (Post)
Hallo, seit der Umstellung meines Projektes auf die aktuelle Codesys Version mit aktuellen Bibliotheken und Aktualisierung der Runtimer Version bekomme ich im Zeitraum 15min bis 1h nach Neustart des Target Systems folgende Fehlermeldung: runtime received SIGABRT - system may be in an inconsistent state Der Fehler kommt auch nach dem Start des Systems ohne eine Benutzeraktion zuverlässig, aber in unterschiedlichen Zeiträumern. Hier sind die Logs und Daten, die ich dazu ermitteln konnte: $ tail -f /var/opt/codesys/codesyscontrol.log 2025-04-03T06:54:37.659Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client for Extern-ID: 594337835 2025-04-03T06:54:37.660Z, 0x0000100c, 1, 0, 0, Visu_PRG: Creating Client successful for Extern-ID: 594337835 Returned IEC-ID: 0 2025-04-03T07:01:38.135Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:01:38.135Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE 2025-04-03T07:02:18.181Z, 0x00000103, 65544, 1, 0, runtime received SIGABRT - system may be in an inconsistent state * We recommend a reboot of the controller now! 2025-04-03T07:02:18.181Z, 0x00000111, 8, 260, 3, #### Exception: HANDLED EXCPT* <excpt>NonContinuable</excpt> in CH_COMM_CYCLE $ vmstat 1 procs -----------memory---------- ---swap-- -----io---- -system-- ------cpu----- r b swpd free buff cache si so bi bo in cs us sy id wa st 1 0 0 271120 33976 342284 0 0 135 2 2387 4751 10 7 82 1 0 1 0 0 271024 33976 342380 0 0 0 0 10163 20427 10 9 81 0 0 1 0 0 271056 33976 342380 0 0 0 0 8455 16869 9 5 86 0 0 0 0 0 271040 33976 342380 0 0 0 0 8674 17484 9 4 87 0 0 0 0 0 271072 33976 342380 0 0 0 0 10070 20350 7 7 87 0 0 1 0 0 271040 33976 342380 0 0 0 0 10354 20802 10 6 84 0 0 0 0 0 271072 33976 342380 0 0 0 0 8401 16923 8 6 86 0 0 $ vcgencmd measure_temp temp=56.9'C $ uname -a Linux PAC4 5.10.103-v7+ #1529 SMP Tue Mar 8 12:21:37 GMT 2022 armv7l GNU/Linux CODESYS V3.5 SP21 Runtime: Codesys control for Raspberry Pi MC SL V 4.13.0.0 Hinweise auf ein instabiles OS oder instabile Netzwerkverbindungen konnte ich keine finden. In dmesg und im syslog gibt es keine Auffälligkeiten. Die anderen Posts zu diesem Thema wurden nicht beantwortet. Hat jemand einen Tip, wie man an das Problem herangehen kann? Vielen Dank
Last updated: 2025-04-03

Post by paulpotat on cm4 runtime problem CODESYS Forge talk (Post)
Hello, We are having the same kind of problem again with the last CM4 we received : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) Hardware Version $ cat /proc/cpuinfo processor : 0 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 1 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 2 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 processor : 3 model name : ARMv7 Processor rev 3 (v7l) BogoMIPS : 126.00 Features : half thumb fastmult vfp edsp neon vfpv3 tls vfpv4 idiva idivt vfpd32 lpae evtstrm crc32 CPU implementer : 0x41 CPU architecture: 7 CPU variant : 0x0 CPU part : 0xd08 CPU revision : 3 Hardware : BCM2711 Revision : a03141 Serial : 1000000097594db7 Model : Raspberry Pi Compute Module 4 Rev 1.1 Kernel Version $ uname -a Linux cmr-pv2-1t00-0001 6.12.25-rt9-v7l #1 SMP PREEMPT_RT Thu Sep 25 11:53:00 CEST 2025 armv7l GNU/Linux OS Version $ cat /etc/os-release PRETTY_NAME="Raspbian GNU/Linux 12 (bookworm)" NAME="Raspbian GNU/Linux" VERSION_ID="12" VERSION="12 (bookworm)" VERSION_CODENAME=bookworm ID=raspbian ID_LIKE=debian HOME_URL="http://www.raspbian.org/" SUPPORT_URL="http://www.raspbian.org/RaspbianForums" BUG_REPORT_URL="http://www.raspbian.org/RaspbianBugs" CodeSys runtime 4.13.0.0 So far we tested runtime versions up to 4.18.0.0, here are the results : * 4.13.0.0 --> Not working ❌ * 4.14.0.0 --> Not working ❌ * 4.15.0.0 --> Not working ❌ * 4.16.0.0 --> Not working ❌ * 4.17.0.0 --> Working ✅ * 4.18.0.0 --> Working ✅ There is nothing in the 4.17.0.0 release note that mentions that, so I'm not sure what to think about this. Is this a known problem within the CodeSys development team ? If yes, how do you follow CM4 hardware evolutions ? Is there a way of making this work without having to update the runtime version ? We have several products working with the 4.13.0.0 runtime and we would like to avoid having to update them all. BR
Last updated: 2026-02-02

Post by vformanek on How to access files correctly in Linux CODESYS Forge talk (Post)
Hello, its still not quite clear to me how to deal with the PLCLogic directory in linux. I have the directory right here: I need to correctly access the files in this folder through CODESYSControl.cfg. Here is my CODESYSControl.cfg where on the first lines there are a few lines: [SysFile] FilePath.1=/etc/, 3S.dat PlcLogicPrefix=1 That means that if I am going to use relative paths its going to go to from the PLCLogic directory right ? For example here: Whitch paths should I use. I cant seem to successfully run any of these aproaches ...
Last updated: 2023-09-08

Post by jari-koivuluoma on JSON_Utilities_SL JSONFileWriter error NULL_POINTER CODESYS Forge talk (Post)
FB jsonFileWriter gives a NULL_POINTER error, why? JSONByteArrayWriter works fine so the JSONData FB should be fine. The device is CODESYS Control Win V3 x64 in simulation mode. Codesys version is V3.5 SP16 Patch 5 JSON_Utilities_SL version is 1.3.0.0 Src: ST_TestStruct1a; TXT: WSTRING(10000); MakeJSON : BOOL := TRUE; SrcJSONData: JSON.JSONData; jsonFileWriter : JSON.JSONFileWriter; IF MakeJSON THEN MakeJSON := FALSE; // Struct data to JSONData FB F_TestStructToJSON(ADR(Src),ADR(SrcJSONData)); // Writing to file jsonFileWriter( xExecute := TRUE, sFileName := 'c:\JSONTEST\JSON.txt', eEncoding := JSON.Encoding.UTF_16, xAsyncMode := TRUE, jsonData := SrcJSONData ); // Waiting to finish WHILE jsonFileWriter.xBusy DO ; END_WHILE // To text jsonArrayWriter( xExecute := TRUE, pwData := ADR(TXT), udiSize := SIZEOF(TXT), jsonData := SrcJSONData, xAsyncMode := FALSE, ); END_IF
Last updated: 2023-09-08

Post by lraja on Codesys Programming with phyBOARD®-Pollux i.MX8M Plus CODESYS Forge talk (Post)
Dear All, I am trying to Developing a PLC using phyBOARD®-Pollux i.MX 8M Plus. It is very difficult to find the suitable Codesys control for i.MX8M. I have tried to install CODESYS Control for Linux ARM SL , but unable install it and I am getting the following error, [INFORMATION] Executing SSH command on root@192.168.0.10: Retrieving architecture from package management [ERROR] Expected exit value of command failed: expected 0, received 127 [INFORMATION] Standard output: sh: line 1: dpkg: command not found Kindly check and help phyBOARD®-Pollux i.MX 8M Plus Link : https://www.phytec.eu/en/produkte/single-board-computer/phyboard-pollux/
Last updated: 2023-09-23

Post by bahrt on Mapping GPIO and adding GPIO configurations CODESYS Forge talk (Post)
Hi I am about to configure ALL GPIOs on a Raspberry Pi 3 model B V1.2. It seems that I have limited understanding of why not all the IO’s become available with the corresponding mapped IO’s – the 'dwInUse' contains mapping of the inputs from GPIO0 to GPIO27. But 'dwInputs' are only showing GPIO0 to GPIO8 and GPIO15 as available inputs. These mentioned inputs work fine You will be able to watch the limited mapped IO activity here: https://drive.google.com/file/d/1zz4PBNBfRZBF2YkiJ2VQxw6L9MBVji7R/view?usp=sharing Can you please bring your best idea on why GPIO09 to GPIO14 and GPIO16 to GPIO27 state are zero in the dwInputs register? Thanks in advance. Best regards Andreas Bahrt
Last updated: 2023-11-16

Post by felipemsgarcia on Edge Gateway online, but PLC is not online CODESYS Forge talk (Post)
Hello, Up until yesterday (2023/11/20) I was able to connect to the PLC remotely with no issues through Edge Gateway. However, today I can see the Edge Gateway online but I can find the PLC even if I do a network scan. Following the same path as janber0206 @ https://forge.codesys.com/forge/talk/automation_server/thread/e78b11d7e9/, I looked into certificates and found that one of the Trusted publisher certificates has expired earlier today (2023/11/21). Please see image. Questions are: Does it affect the connection to the PLC through Edge Gateway? How do I fix it? Thank you very much in advance!
Last updated: 2023-11-21

Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working CODESYS Forge talk (Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22

Post by seppi on Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C. CODESYS Forge talk (Post)
Hello everyone, I want to establish communication between my Arduino and my Raspberry Pi via I²C, but I have no idea how to make it work. However, it should work because there are many examples available, although none of them were programmed using Codesys, but rather using Python. My Raspberry Pi will be the master and is supposed to exchange measurement data such as speed and battery capacity with the slave (Arduino). I would be very grateful if someone could help me with my problem. Here is another link that could be helpful. However, I can't find the mentioned libraries
Last updated: 2023-12-03

Post by vamsi on How to configure gateway for programming RPi 2B using Codesys CODESYS Forge talk (Post)
I am using a Raspberry Pi 2B. Installed Codesys V3.5.20.1 64-bit and installed 'CODESYS Control for Raspberry PI 4.12.0.0' I am able to install the packages using the 'Update Raspberry Pi' option, but when I try to log into the RPi, in the Device tab it says 'Sacn fail. Please checl that the gateway is running and that its settings are correct'. My setup looks like this. I connected my RPi to my company LAN and also my laptop to company LAN (using HP Docking station). This setup worked when I installed 'CODESYS Control for Raspberry PI', but now I donot know how to configure the gateway. Could anyone please help me in finding what I have to enter in the gateway configuration? Thanks, Vamsi.
Last updated: 2024-07-10

Post by rcanfield on Code Coverage and Test Manager CODESYS Forge talk (Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11

Post by rcanfield on Code Coverage and Test Manager CODESYS Forge talk (Post)
I am exploring the possibility of measuring test coverage using the Test Manager and Profiler tools. It appears there are some significant limitations. Has anyone been successful trying to use these tools? Here are my observed limitations. Am I misunderstanding anything? * Profiler only works for one "run cycle". Even warm resets will clear the coverage calculations. Thus, all tests would have to manually reset values when complete to prevent contamination to other tests. * It is not possible to see which statements were/weren't executed. One would have to use the flow control tool which cannot be used in conjunction with the Profiler, and must be viewed in realtime. * The profiler control cannot be automated and therefore must be executed through a manual procedure. Thank you!
Last updated: 2024-07-11

<< < 1 .. 187 188 189 190 191 .. 194 > >> (Page 189 of 194)

Showing results of 4831

Sort by relevance or date