Post by balazska2 on Position values with integer variables
CODESYS Forge
talk
(Post)
Hello guys! https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_elem_label.html My question: Could I give an integer variable to the Position records (in the Element list => Position => width / height)? If yes, how? I defined a TEST integer variable with 300 value. I tried to add this variable to the width record (.TEST or only TEST), but if I saved, the value jumps back to 0. Thanks for your help! :)
Last updated: 2024-10-03
Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time
CODESYS Forge
talk
(Post)
I have noticed that a rm file1.txt command on a shell has an impact on the cycle time for a TASK writing to file2.txt. Seen in the Monitor fane of the Task configuration Furthermore if a TASK makes a system call like rm, its cycle time increases of course but it seems to have an invisible impact on other TASKs too. I have a TASK for handling communication over the CANbus (SPI) where it stops sending "Heartbeats" for many seconds when another TASK does a system rm. Why is that not seen on the Monitor fane? Is even codesyscontrol paused when system calls are made? The CPU load is about 30-40%
Last updated: 2024-09-23
Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks)
CODESYS Forge
talk
(Post)
Hello! I use CheckBounds (POUs for Implicit Checks). But I have a problem. I use an array as an VAR_IN_OUT of Function Block. If I try to monitor the array of variable length ([* ]), its does't work. The CheckBounds POU isn't called. If I use the array of fixed lenght ([lower..upper]), the CheckBounds POU is called. Why?
Last updated: 2023-11-14
Post by leon78 on Codesys 3.5 SP17 Patch 2 CheckBounds (POUs for Implicit Checks)
CODESYS Forge
talk
(Post)
Hello! I use CheckBounds (POUs for Implicit Checks). But I have a problem. I use an array as an VAR_IN_OUT of Function Block. If I try to monitor the array of variable length ([* ]), its does't work. The CheckBounds POU isn't called. If I use the array of fixed lenght ([lower..upper]), the CheckBounds POU is called. Why?
Last updated: 2023-11-14
Post by siscu on Raspberry Pi: List of available example applications
CODESYS Forge
talk
(Post)
Could this be turned into a library? I'd love for a way to have the main program call a function block method using the program's I2C_master device. I assume I should be passing the master as a variable for the function block, but I don't see how that could be achieved
Last updated: 2024-05-15
Post by alink on Visu - changing auto-logout time
CODESYS Forge
talk
(Post)
Hello is there a chance to set with a visu input the auto-logout time? At the moment, it is a fix value set in visu-manager. But for individual configurating of passwort policies I create a visu-dialog to set policies and there for an option to set auto-logout-time. But till now, I haven't found a solution. Maybe someone has an idea? Thanks
Last updated: 2023-11-30
Post by sigurdrb on Codesys and error messages, warnings exceptions etc.
CODESYS Forge
talk
(Post)
Hi, I tried some different libraries (CmpApp etc.) to find some global variables that I could read out as a variable in the codesys environment. Do any one of you know which libraries are best suited for this, and how I can read it out? My goal is to send messages, warnings etc. to the system that communicates to the PLC. Currently if something goes wrong I need to see the logfiles, or go online with the controller. I think I could save a lot of time if I could read the errors from our user interface that is connected to the PLC by TCP/IP.
Last updated: 2024-11-06
Post by trusty-squire on Confused by dwIpoTime input for SMC_Interpolator
CODESYS Forge
talk
(Post)
OK, that makes sense. Because the FB is provided a specific interval period, it would change the target position accordingly based on the time it "thought" elapsed. If it has the wrong interval provided, it updates the target positions every cycle incorrectly so the axes will end up moving faster or slower. Thanks!
Last updated: 2024-07-22
Post by danwoodlock on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
I believe the reason that I eventually lose my ability connect is because of exceeding the time limit for demo mode. Still unsure why I cannot update the edge gateway though.
Last updated: 2023-09-13
Post by mbmik on IoDrvModbusTCP_Diag not defined when using MODBUS
CODESYS Forge
talk
(Post)
Thanks alot for your time and help! I quickly tested the suggestion, as it makes a lot of sense. Unfortunately the erros still appear as before. The settings was already set before, and i tried turning it off.. no effect..
Last updated: 2024-04-16
Post by dengsberg on Check Connection Status of the OPC-UA Server for Data Source Manager with OPC-UA Client
CODESYS Forge
talk
(Post)
Another question is how to test the quality of the individual variable?
Last updated: 2024-09-07
Post by dtamm on How to read string from CharBufferPtr?
CODESYS Forge
talk
(Post)
Solved it! The simple answer was to declare a variable as POINTER TO STRING and assign the GetMessage result to that variable. Then, the ^ operator can be used to extract the message as string.
Last updated: 2024-02-21
Post by macros8 on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi, I haven´t noticed you put the comment here. I thing it´s a bit different. What I want is to have detail errors of technology in data type e.g. INT. This variable I would latch to the corresponding error msg but I would like to get it convert to text from the text list and not keep it in INT form. Example. Main error Valve Error: SubErrors 1 - Both sensors 2 - Not retracted in time 3 - Not pulled out in time In HMI Main error + latch SubErrors => "Valve Error: Both sensors" The benefit is that text lists are part of translation and can be easily manipulated. I know I can create whole string msg in PLC but then, it lose advantage of Alarm management. Thanks. M.
Last updated: 2023-11-07
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by jeroenaero on CodeSys Raspberry pi I2C driver not found
CODESYS Forge
talk
(Post)
Finnaly i get it working. There was a line in the file that set the ADS1015 chip in /boot/firmware/config.txt which i removed and after that the ADS1115 has a green turning circle and i got values. i created a new component so it fits our ADS1015. see screenshot. It works also with Codesys Control for Raspberry Pi 64 SL after adding the ULINT_TO_UDINT conversion in the library. i think the chip was all the time in use by the Raspberry pi itself. Thanks for your help!
Last updated: 4 days ago
Post by paulpotat on Exclude traces when searching with ctrl+F
CODESYS Forge
talk
(Post)
Hello, I was wondering if there is a way in codesys to exclude the traces from the search when using the "ctrl+F" window ? That would be nice to improve the search functionnality when looking for a specific variable. Sometimes when I iterate through all occurences with the "find next" button, it opens the trace configuration window. I would expect to be able to close it and go to the next occurence with the "find next" button, but after closing the trace configuration window the search says it has reached the end of the scope (even if in reality there are other occurences of the variable elsewhere). I tried to enable / disable the "search up" checkbox but it's not changing anything. I hope somebody have insight on this, BR
Last updated: 2024-08-06
Post by dkugler on Converting hex bytes to float
CODESYS Forge
talk
(Post)
have a look at UNIONs. With a union you are able to write single bytes to the same adress area which belongs to a float variable at the same time. I like to do a lot of convertions belonging to interfaces and fieldbus in this way, f.eg. word / byte swapping etc.
Last updated: 2024-08-06
Post by varshag on Trying to pull Logged In user details and certain other variable values and in turn log to a database
CODESYS Forge
talk
(Post)
Hello All, I am new to Codesys and am trying to create a simple project which would let me log to a 6 column database table. I can use a push button on Visualization to initiate the logging. Column 1:Timestamp Column 2:Full name or Initials of Logged in operator Column 3,4,5,6: Certain variables Any help is highly appreciated. Thank you.
Last updated: 2024-11-07
Post by sturmghost on Initialization of visualization variables and cyclic code execution
CODESYS Forge
talk
(Post)
I'm looking for a smart and short way to implement initialization of visualization variables depending on the visualization input. For an easy example consider a rectangle which rests at XPos := 0 when the input state is false and at XPos := 50 when the input state is true. My visualization variables look like this: VAR_IN_OUT State : BOOL; END_VAR VAR XPos : INT; END_VAR I put this rectangle via a visualization frame element into another visualization and link a frame reference variable with the state to it. If the variable is true, the rectangle should rest at XPos := 50 and false at XPos := 0 at visualization init but how should I assign the 50 or 0 to the internal visualization variable XPos? I would need some init-methode for the visualization but I dont want a global init-method for such tasks. I want to do it inside of the visualization element but I can't see any solution for this? It would be good to be able to define ST-code within the visualization element which runs cyclic at each VISU_TASK task-cycle then I could just check the input state and change the XPos accordingly. Does someone have a solution?
Last updated: 2023-10-01
Post by mubeta on parker servo and position
CODESYS Forge
talk
(Post)
In general, drives have parameter sets to adjust behaviour in such cases: position recovery, adaptation with resistant torque, out-of-position window failure, etc. (Much depends on the type of configuration set for the axis: positioner, speed controller, torque controller, etc.). I have used that type of drive very little, in only two cases and a long time ago. To tell you what is normal is impossible. I know by reputation they are very simple objects, without too many pretensions and adjustments possible. Try running traces by monitoring actual position, motor current, torque and following error. These are the most sensible curves to understand what is going on. Maybe by fine tuning the motor tuning, the current controller or the speed controller you will get something closer to what you want. For example, from DS, the motor has a standstill torque of 3 Nm. Observe with traces whether this is effective: motor current trend. And afterwards, when you have your own accurate picture of the situation, you can also hear from the product's local support to see if you can steal a few more things from it performance-wise.
Last updated: 2024-08-05
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
I found a way to do it: You can use, for example, the text variable property of any visualization element and call a function in it. Example: Write a test POU as a function (FUN), like MyTestFun which need a boolean Variable as an input value. Now write into the text variable property: MyTestFun(bBooleanValue) Thats it. The function is called at each visu_task cycle.
Last updated: 2024-01-22
Post by dhumphries on Toggling Visualizations using HMI Physical Buttons
CODESYS Forge
talk
(Post)
Nothing wrong with ladder, in a lot of applications it is simpler than ST or CFC, you're a lot less likely to have syntax issues in a ladder diagram than in structured text as long as you stick with traditional ladder elements. Your attempt was almost valid, but you tried to change the currentvisu variable using a blend of structured text and ladder, which isn't allowed. You need to use the MOVE operator and define the visualization name as a string on the input side and the visuelems.currentvisu as the target on the output side.
Last updated: 2024-02-28
Post by eschwellinger on codesys VLAN tagging
CODESYS Forge
talk
(Post)
no we'll an example for it but need some time.
Last updated: 2024-09-09
Post by ferrim on IEC 61499
CODESYS Forge
talk
(Post)
Hello otdeveloper, I am very interested in this topic. I have been dedicated to IEC 61499 for some time and I would like to understand if the time has come to adopt it in the real world of automation or if it will continue to fill up research papers only.
Last updated: 2024-02-09
Post by ron-rp on Errors with VisuUserManagement library
CODESYS Forge
talk
(Post)
Hi all, I've played a bit with the VisuUserManagement library, and some other security option in my project, and I started getting this error when logging in - see attached pic. something to do with a specific screen in the library - VUM_Login. Also, Codesys started to ask me to log in to the library when logging in, asking to log in as user of the groups Maintainer or Owner, which I dont know either users (attached pic). when I close the login screen and try to log in to the PLC again, everything works again until I close and open Codesys. I do use user and password to login to the PLC, and this login screen is fine I know the user and pass I setup. anyone know what did I do wrong here and how to fix it?
Last updated: 2024-06-25