Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
Hi, thanks for the fast response :) Yes I Have a .err file. Sorry I forgot to upload it. It is a binary file though... "Runtime goes in exception before the shutdown ?" I think it goes into exception at the same time as the power is lost...
Last updated: 2024-10-03

Post by jwhaley on C0007 Errors CODESYS Forge talk (Post)
Hi all. I'm pretty new to codesys. Maybe a few months. I've had on and off issues here and there. This issue I cant figure out. The top line is one of 2 that I had. The other one has mysteriously left. the 2nd and 3rd showed up after I restarted the program. I'm not sure how to take care of them. Please help!
Last updated: 2024-10-03

Post by pietrobalint on Persistent variables are not read after initialization CODESYS Forge talk (Post)
Hi, I realized that if I replug the power supply the persistent variables lost their value with the new software too. Cold reset do not affect the variables value but hardware reboot still reset the values. Application Composer can't be activated. What is the solution?
Last updated: 2024-10-11

Post by dekelec on TrueType font problem CODESYS Forge talk (Post)
Initially I had the same problem in CoDeSys when selecting a newly installed TTF font, while CoDeSys was running. I solved it by closing Codesys and running it again to restart the initialization process. After that, using the new font did not pop up errors. I also had cases with files that had a ttf extension, but were actually not TrueType.
Last updated: 2024-10-22

Post by marekxc on Compiling Errors with Ethernet/IP Scanner CODESYS Forge talk (Post)
Update the Device: Right-click on the device icon in the project tree. Select the “Update Device” option. Recompile the Project: After updating the device, recompile the project from scratch to ensure that all changes are included. Check Task Settings: Go to the “Tasks” tab in the project. Check the priority settings for the tasks to ensure they are configured correctly.
Last updated: 2024-11-09

Post by teichhei on The selected container ... does not fit your ticket CODESYS Forge talk (Post)
After correspondence with Mr Schwellinger from Codesys the resolution for this was to uninstall the SL 4.14 and install SL 4.13 on the device. Once this was done the licensing worked as expected. I noted that the container then showed a Version 3.00 and not 0.00.
Last updated: 2025-01-11

Post by smic on Virtual Control SL Profinet connection CODESYS Forge talk (Post)
Hi. I'm trying to connect Profinet device with Virtual Control for Linux SL. After adding devices, I couldn't find actual device by Scan Device? Do I missed something? VPLC container on Docker IP: 172.17.0.4 Subnet: 255.255.0.0 Gateway: 172.17.0.1 Profinet device: AL1100 io-link master (default setting) IP: 0.0.0.0 Subnet:0.0.0.0 Gateway:0.0.0.0
Last updated: 2025-02-28

Post by helcioburd on How long can a WSTRING be in CodeSys V3? CODESYS Forge talk (Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02

Post by cellohorst on File Creation Issue CODESYS Forge talk (Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03

Post by suyash on Version Control CODESYS Forge talk (Post)
Hello, I face issues opening old Codesys 3 program when I am having a newer version installed. Unfortunately since I was forced to format my laptop after an unexpected crash. I lost all the setup files of the older versions. Is there ant where I can download it from? BR, Suyash
Last updated: 2025-03-07

Post by programmer on 3.5 P20 hangs - no response CODESYS Forge talk (Post)
hi imdatatas, thanks for your suggestion! I added the process execution to be sure. In the meantime I reïnstall Windows but it dind't help directly. Finally I deleted CodeMeter Runtime Server after Codesys installation. Because this Service was not able to start. And it works (for now) :)!
Last updated: 2025-06-25

Post by ganassa on Custom colors in Ladder diagrams? CODESYS Forge talk (Post)
How can I change the default color - blue - for active lanes, contacts and coils? I'd like a lighter color. After having failed in finding a related option in the IDE, I've looked at the "Default.editortheme" file in CODESYS' directory, but couldn't see any related option. Thank you
Last updated: 2025-07-09

Post by rickwot809 on Codesys Soft PLC OPC UA server CODESYS Forge talk (Post)
Enabling Anonymous Login 1. Navigate to 'Device' > 'Communication Settings' > 'Device'. 2. Next, click on 'Change Runtime Security Policy'. 3. In the new window, find and check the box for 'Allow anonymous login'. After completing these steps, you should be able to communicate with the OPC UA server.
Last updated: 2025-09-11

Post by svn123 on In Simulation Mode, logic is not executing CODESYS Forge talk (Post)
I stopped the simulation and tried to rebuild. "Cloned Task0.task0. Priority already in use" error was shown after rebuilding. I used Build-Clean All option and rebuilt again. Now the logic started working. But I am not still sure what caused the error in first place. If somebody knows about this error, please enlighten me. Thanks svn
Last updated: 2023-12-25

Post by martinlithlith on Raspberry Pi: List of available drivers / libraries CODESYS Forge talk (Post)
Hi! I'm still on the hunt for drivers for example TCA9548 and a list or somewhere where all devices for raspberry is gathered. as this post is quite old I'm hoping/gussing that there is somewhere where work after 2021 is gathered? Or has the raspberry part if the community slowed down on creating device drivers?
Last updated: 2023-12-31

Post by peter-skokanek on Rpi install runtime licence on SP13 CODESYS Forge talk (Post)
Hi, I have an older project which has been running for years. Unfortunately I have to replace current Raspberry. I repplaced it by new rpi 3 with newest 32 bit Raspberry OS. I oredered a new runtime licence. When I try to activate it, the connection to target is interrupted immediatelly after press next button in the last step of instalation.
Last updated: 2024-01-08

Post by kees-b on PLCnext Phoenix Contact CODESYS Forge talk (Post)
Hello We started with the new design of Codesys, through a "CODESYS Control Standard S" license. However, after installing the license, connecting, etc. (without any problems), we cannot get the program into the PLC with entries that we have not seen before. Is there anyone who has also experienced this? Better yet, does anyone have the solution?
Last updated: 2024-01-24

Post by dkugler on Color Change for Symbols not working CODESYS Forge talk (Post)
to modify and change the color of this icons from symbols lib I placed it in a visu. After download to the device, I uploaded the SVG files and saved it local. Now I was able to modify them with inkscape and import it to my own imagepool in the project :-)
Last updated: 2024-02-13

Post by reinier-geers on SysFileOpen does not work after update to V3.5 SP19 Patch 5 CODESYS Forge talk (Post)
At 19.1 the hFile_test should be RTS_IEC_HANDLE and always open-write - close in one cycle udi_handle: RTS_IEC_HANDLE; //handle-number. Is created by SysFileOpen udi_handle:=SysFileOpen(sFileName,Sysfile.AM_WRITE_PLUS, ADR(udi_ErrorCode)); udi_RetValWrite:=SysFileWrite(udi_handle, pRemBuffer, szRemBufSize, ADR(udi_ErrorCode)); //closing file IF udi_RetValWrite < szRemBufSize THEN ui_Error:=cWriteError; END_IF//error writing data udi_ErrorCode_Close:=SysFileClose(udi_handle);
Last updated: 2024-02-19

Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5 CODESYS Forge talk (Post)
Finally this solved my issue: https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/, and the official documentation https://faq.codesys.com/display/CDSFAQ/SysFile%2C+Persistence+Manager%2C+Datalog+Manager . Add the media folder to the PlaceholderFilePath. Like this: PlaceholderFilePath.2=/media/pi, $usb$ PlaceholderFilePath.2.View=1 PlaceholderFilePath.2.Volatile=1
Last updated: 2024-02-19

Post by k4zz on Static Code Analysis CODESYS Forge talk (Post)
I've already experimented with two methods, but unfortunately, they only function with projects of type *.project. Consequently, when executing: system.commands["staticanalysis", "run"].execute() For the 2nd Option: You'll need to ensure that in the Static Analysis Settings, the option "Perform static analysis automatically after compilation" is checked. # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code()
Last updated: 2024-03-15

Post by hwopereis on Codesys Control shutdown CODESYS Forge talk (Post)
Hi, I'm experiencing this problem as well. Did the suggested combination resolve your issues in the end? If not, I can stop my efforts rolling back to these versions. I'm trying to get CC for RPi 4.8.0.0 installed on the device, but I can't find it after installing it through the packet manager.
Last updated: 2024-03-25

Post by idir93dz on Identifier 'IoDrvGPIO' not defined CODESYS Forge talk (Post)
Hello, After installing the pi runtime and creating a pi project, I get these errors: [ERROR] Untitled3: Application [Device: PLC Logic]: C0046: Identifier 'IoDrvGPIO' not defined [ERROR] Untitled3: Application [Device: PLC Logic]: C0080: Function block 'IoDrvGPIO' must be instantiated to be accessed [ERROR] Untitled3: Application [Device: PLC Logic]: C0004: 'IoDrvGPIO' is no component of 'IoDrvGPIO'
Last updated: 2024-04-10

Post by danwoodlock on Rpi zero w lost license after 4.11 update CODESYS Forge talk (Post)
Just adding some info: Today I found this post: https://forge.codesys.com/forge/talk/Runtime/thread/264bd530d4/ followed the steps suggested started with a fresh install of raspbian lite, installed 4.11, and then attempted to import my license update file. I get this when I do: Any help is appreciated.
Last updated: 2024-04-15

Post by installwhat on raspistepper error after install CODESYS Forge talk (Post)
from another post on this forum .... In your library project select Project -> Project Information. On the Properties table remove the "LanguageModelAttribute" Value "Qualified Access Only". This will allow you to access the object without qualifying the access. ...... I guess they've compiled it the library with that setting and now I need to mess around with versions.
Last updated: 2024-04-20