WIN 2008 Server - OPC Server CodeSys - HELP
CODESYS Forge
talk
(Thread)
WIN 2008 Server - OPC Server CodeSys - HELP
Last updated: 2010-11-17
Scripting access rights to OPC Symbol Set?
CODESYS Forge
talk
(Thread)
Scripting access rights to OPC Symbol Set?
Last updated: 2023-03-15
Cannot login when opc client is connected
CODESYS Forge
talk
(Thread)
Cannot login when opc client is connected
Last updated: 2016-09-05
OPC-server and FSGateway 2012 communication problem
CODESYS Forge
talk
(Thread)
OPC-server and FSGateway 2012 communication problem
Last updated: 2012-04-17
2.3 Symbol File in 3.5 OPC Configurator
CODESYS Forge
talk
(Thread)
2.3 Symbol File in 3.5 OPC Configurator
Last updated: 2017-02-28
Codesys Control PFC (8208) - OPC and RS
CODESYS Forge
talk
(Thread)
Codesys Control PFC (8208) - OPC and RS
Last updated: 2022-09-01
Variablen von einem anderen OPC Server lesen
CODESYS Forge
talk
(Thread)
Variablen von einem anderen OPC Server lesen
Last updated: 2009-06-09
can two different OPC server share same port?
CODESYS Forge
talk
(Thread)
can two different OPC server share same port?
Last updated: 2020-11-11
OPC-Server V3 - keine Items zu sehen...
CODESYS Forge
talk
(Thread)
OPC-Server V3 - keine Items zu sehen...
Last updated: 2009-05-26
Eine obligatorische OPC DA 3.0 Schnittstellen n. gefunden
CODESYS Forge
talk
(Thread)
Eine obligatorische OPC DA 3.0 Schnittstellen n. gefunden
Last updated: 2008-08-15
Probleme mit OPC-Server und Wago 750-841
CODESYS Forge
talk
(Thread)
Probleme mit OPC-Server und Wago 750-841
Last updated: 2010-06-17
OPC Server, zero values when communication down
CODESYS Forge
talk
(Thread)
OPC Server, zero values when communication down
Last updated: 2016-11-11
two different OPC clients with different privileges
CODESYS Forge
talk
(Thread)
two different OPC clients with different privileges
Last updated: 2024-02-01
OPC Da Server Code Meter Issues after Enabling License
CODESYS Forge
talk
(Thread)
OPC Da Server Code Meter Issues after Enabling License
Last updated: 2024-05-03
Post by tcarlbom on Read tag values using external program
CODESYS Forge
talk
(Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28
Post by gediminas on Datasource OPC UA client system failure
CODESYS Forge
talk
(Post)
I am using CODESYS v3.5 SP20 Patch 3 / Control for BeagleboneBlack SL v4.13 and after some time the OPC UA Server crashes. However, Runtime still works without any issues. The events leading up to the OPC server crash are the most suspicious: 1) Mutex deadlock detected - owner thread died, and 2) Runtime received SIGABRT. And it seems very similar with this topic except used versions - issues should be fixed with previous SP's. I can't seem to find any information about these events. Need some pointers in the right direction on how I can fix this problem.
Last updated: 2024-10-25
Post by alexgooi on OPC-UA and other communication questions
CODESYS Forge
talk
(Post)
Dear forum, I currently have a big question mark above my head, and maybe this forum can shine some light on the situation. I recently updated to Codesys 3.15 SP19 Patch 6. And now I’m trying to setup the OPC-UA server, besides that I’m trying to connect to the controller with the Codesys V3 (Ethernet) protocol. OPC-UA I have installed the correct licenses on my controller (Runtime and communication). I’m able to connect to the controller with an OPC-UA client, and I’m able to browse the tags, so far so good. Therefore I’m assuming that the OPC-UA server is running on the controller. But now the strange part, in the device security settings I have set the communication Policy to BASCI256SHA256 ( I also have tried the other ones) and the communication mode is set to secure if possible (I also have tried all the other ones) (see picture). With these settings I would assume that I would only be able to login with a Basic256SHA256 policy with a client. But the opposite is true, I am able to login using the no policy mode and when I set it to Basic256SHA256 the client (UA-Expert) notes that this policy is not available on the server. I then check the certificates and I noted that there is no certificate for the OPC-UA server, I tried to generate one but it gave the error that the certificate has not been created by the device (See picture). To summarize I have no clue what is going on, and the controller does the opposite of what I would expect. Codesys Ethernet V3 driver I have a HMI connected to the same controller using the Ethernet V3 driver. But this will not connect. I tried all the Protocols (see picture), with and without the username and password enabled. But it will not connect, when I scan the available servers I can see the controller with the port number that I am expecting, so I’m assuming that the Codesys V3 ethernet driver is up on the controller. Does anyone can give me some direction, because the stuff that I tried doesn’t make sense to me. Thank you in advance
Last updated: 2024-04-02
PLCopen XML Import - Creation of object failed... The given key was not present in the dictionary
CODESYS Forge
talk
(Thread)
PLCopen XML Import - Creation of object failed... The given key was not present in the dictionary
Last updated: 2019-01-31
how to create a new XML file description for new device
CODESYS Forge
talk
(Thread)
how to create a new XML file description for new device
Last updated: 2018-05-14
Is there any material for us to guide to build a device xml file and library.
CODESYS Forge
talk
(Thread)
Is there any material for us to guide to build a device xml file and library.
Last updated: 2017-05-28
Darstellung von ä,ü,ö,Ä,Ü,Ö in XML Sprachdatei
CODESYS Forge
talk
(Thread)
Darstellung von ä,ü,ö,Ä,Ü,Ö in XML Sprachdatei
Last updated: 2009-02-11
EtherCAT EEPROM imaging with ESI (.xml) file using Codesys EtherCAT master
CODESYS Forge
talk
(Thread)
EtherCAT EEPROM imaging with ESI (.xml) file using Codesys EtherCAT master
Last updated: 2022-04-12
about the dont use font height in the xml file
CODESYS Forge
talk
(Thread)
about the dont use font height in the xml file
Last updated: 2014-06-10
Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Thread)
Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
Last updated: 2024-08-07
Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
CODESYS Forge
talk
(Thread)
Test a manager script (.tsd file{xml document}) not starting from Git CI heedlessly/ without ui
Last updated: 2024-08-07
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.