Post by pavel-doreng on GetCurrentUser
CODESYS Forge
talk
(Post)
Hi im only have 3 groups \ users - the deafault ones admin \ servie \ operator i JUST NEED TO KNOW WHO IS CURRENTLY LOGGED IN TO Display the user name , thats all this code above do not work for me please help im sure its very simple
Last updated: 2024-01-23
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by reinier-geers on License problem gateway
CODESYS Forge
talk
(Post)
The hole setup is made by 3s. So its a comination of one not two. If Epis decide not to support extra licence whats then the funtion of providing an option with a single license ?? So the idee by 3s has a flod. Epis change the system to add the Stick. I send controller inc stick to Epis. On my software i can see the stick. An then you tel me i need a other license to use an license ?? Makes completly no sense. Codesys should be flexible but is not. I tried Delta. But has no HMI and has its own Codesys ?? Why ?? Then i tried Crist. The block there own system by a password. But dont know the password and cant switch it off. At the end the want me to pay for support to solve ther own made problem. So i send it al back. The extra license is adviced by 3s . Now a few month later still no working solution.
Last updated: 2024-05-01
Post by tanman19 on How to Use Personal Access Tokens from GitHub with Codesys Git
CODESYS Forge
talk
(Post)
I am trying to push changes to a GitHub repository. I set up the Git Remote with the correct URL and committed the change. When I push the change it asks for my GitHub credentials which I know are correct, when I type in my username and password it gives me an error: "The provided credentials seem incorrect." So I tried putting in my Person Access token and when I put that in with my username I get this error: "The server request failed and returned a HTTP error code 403: Forbidden". Does anyone know how to correctly use Personal Access Tokens from GitHub with Codesys Git? Does it have to do something with the remote url or my username? Any help or guidance would be appreciated.
Last updated: 2023-09-28
Post by mwandy on Codesys Project Protection
CODESYS Forge
talk
(Post)
I'm having trouble finding clear answers on this. I'm looking for a way to make a Codesys project password protected so that if the project is distributed it can be used to log into a controller to view and debug logic. At this same time I want to prevent the project from being saved as well as edits being downloaded to the controller. Basically I want to make a whole project view-only. What is the beat way to achieve this? I have had minor success with access rights, which solves the problem with trying to login if the project doesn't match what is in the controller. However with this solution, edits can still be made and saved, possibly corrupting the core project, preventing future logins. Any suggestions?
Last updated: 2024-03-29
Post by rmaas on Fieldbus has lost synchronicity
CODESYS Forge
talk
(Post)
Hi, On a gantry system with 2 axis i am getting the following error: SMC_DI_FIELDBUS_LOST_SYNCRONICITY This happens random, sometimes it happens every 5 minutes and sometimes no error for 2 hours... The Setup: - Using codesys 3.5 SP20 with all latest libs... - Kontron AL Pi-Tron CM4 with Preempt realtime patch (Raspberry Pi 4) - Codesys runtime 4.11.0.0 (single core) - CODESYS Control for Raspberry Pi SL licensed - Softmotion + CNC + Robotics licensed - 2x Leadshine EL8-EC400 servo drives - Axis group for a 2-axis T-Gantry Ethercat network wiring: Ethercat master softmotion -> Beckhoff EK1100 -> Servo drive #1 -> Servo drive #2 Ethercat Cycle time = 4ms Max Jitter = 140~150 What i have tried so far: - changed the sync offset from 20% to 30% - changed ethercat task priority from 1 to 0 Running tasks: - Ethercat tast: Prio = 0, Interval = 4ms - Main task: Prio = 1, Interval = 8ms - Visu task: Prio = 31, Interval = 100ms - Softmotion planning task: Prio = 15, Freewheeling - 3 other default tasks that were created by AC_Persist Motion fb's are called in the ethercat task... Does anyone have an idea how to fix this? Any help is greatly appreciated!
Last updated: 2024-04-11
Post by phoward131 on Alarm State Icon
CODESYS Forge
talk
(Post)
I am trying to create an icon on an overview screen that depicts if an alarm group has active alarms, active acknowledged alarms, or inactive unacknowledged alarms (waiting for confirmation). I've attempted to set up Notification Actions in the Alarm Class to set variables based on state changes but have been unable to find a clean and effective way to do this. Because an action on any alarm will trigger the variable to be set as instructed, I'm struggling to find a way to configure it for what I need (ie if two alarms activate, then one deactivates, the variable for indicating an alarm is active would be cleared after the single deactivation). I've been pointed toward the Alarm Manager example project but I'm finding it too complicated to understand how to implement it in my own project. Has anyone come up with another good way to indicate the states of alarms or a simpler usage of the Alarm Manager functions?
Last updated: 2024-04-23
Post by martinlithlith on Device User Logon and No device is responding.. Pi4b codesys 3.5 SP19 2 + (64-bit)
CODESYS Forge
talk
(Post)
Hi! Im slowly starting to loose it and i need som help! After a few night of reading up and testing iΒ΄m still stuck as a rock and you guys and girls are my last resort for this project. Basic facts; Win 11 Codesys 3.5 SP19 2 + (64-bit) Raspberry pi 4 model b 2 gb Raspian release 11 aarch64 What keeps me up late at night; Username and Password when trying to connect to device and device only beeing connectable for a few seconds. Some of the things I have tried; Username and passord; Credientials from the raspberry Administrator Administrator admin admin Admin Admin administrator administrator Usernames and passwords that I sometimes use (this was a longshot i know, but i was running out of ideas and energy). :) Epand filesystem, activating i2c, spi, 1-wire I can start the gateway and start the runtime. I cant install the edgearm64, arm64 runtime package eventhough I guess i should, i get code [ERROR] Error output: dpkg: error processing archive /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb (--install): [ERROR] Error output: package architecture (arm64) does not match system (armhf) [ERROR] Error output: Errors were encountered while processing: [ERROR] Error output: /tmp/codesysedge_edgearm64_4.8.0.0_arm64.deb code as a respons. I have tried to Reset Origin Device - no change. I have tried to remove the /etc/CODESYSControl_User.cfg [CmpUserMgr] but i could not find it and i was not sure if i should add it instead but i did not want to mess somthing up. I have tried to create a second gateway with the specific ip if the pi, that did not help. Could it be that iΒ΄m currently connected to the pi through WIFI? I can ping the pi and I can connect and control it through VNC. When i scan to select gateway target (scan edge gateway) i find 17-21 devices but can find the pi throug the mac adress. I started of trying to use the "CODESYS Control for Raspberry Pi SL" (I have a license sience earlier) as i read somewhere that this could be used on a Pi4 as well but now iΒ΄m trying with the MC SL, no changes, same problem. Right now - gateway version 4.8.0.0 (edgearmHF, armhf), Runtime Package 4.5.0.0 (raspberry, armhf). Any sugestions are very welcome! As mentioned above, theese are some of the things that i have tried/done - but i have been going at this for a while. Best, Martin
Last updated: 2023-09-10
Post by riccardo on Web Browser special tools errors
CODESYS Forge
talk
(Post)
Nano goodmorning and thanks for the reaply, the links I have to manage are links as the following: https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm I saw that with Wikipedia or other web sites the tool works but not the link above. "google and some other providers, prevent from using as iframe and similar injections." The goal I'm pursuing is to display remote graphical user interfaces from a local graphical user interface over a local network. thanks in advance, Riccardo
Last updated: 2024-03-06
Post by dkugler on User management
CODESYS Forge
talk
(Post)
If the PLC is equieped with a USB socket it's possible to copy the user management file via IEC code to a USB stick and restore it at the new plc. The file is located there: /PlcLogic/visu/app_visuusermgmtdb.csv I use this to reset the user management to default in case of the customer has changed passwords and lost it.
Last updated: 2024-09-04
Post by rmaas on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia
CODESYS Forge
talk
(Post)
Wow, this is next level for me, very impressive! glad you found a solution, thanks for sharing!
Last updated: 2024-02-13
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
Last updated: 2023-12-20
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
Yes
Last updated: 2023-12-20
Post by mp9876 on Device User Logon
CODESYS Forge
talk
(Post)
Just adding some info regarding the issue above. Logged onto the project using dev3og5 user (see screenshots); appeared to be ok although when attempting to logon to the device message says 'currently not authorized to perform this operation on the device' (screenshot). If user dev3og5 has same permissions as Owner user; why would it not be authorized. I am at a loss; any assistance would greatly be appreciated. Thank you Mike
Last updated: 2024-03-16
Post by eschwellinger on User management
CODESYS Forge
talk
(Post)
CODESYS Automation Server could do this too..
Last updated: 2024-09-04
Post by rene-h on VU.FbOpenDialog - TargetVisu - 2 x WebVisu
CODESYS Forge
talk
(Post)
Hello, i am trying to find a way how to open Dialogs on a Single Visu. The options from VU.Globals are Target and WebVisu, but Webvisu opens the Dialog on both WebVisus and it should be separated. CurrentVisu can only be used when the Dialog is called from the Visu, but its all done in the Code. One Webvisu is for the User and one is for diagnostic reasons, and they should not be interfered from each other. Maybe someone can help me with this. Thanks
Last updated: 2024-06-13
Post by rickj on Defining local variables that can be independent with several users.
CODESYS Forge
talk
(Post)
You need to create an array with one element for each possible user. I usually define these arrays in the root screen. FrameIndex : Array [0..MaxUsers] OF INT; Then use the global CurrentClientId (defined by one of the VISU libraries) to index the array element used to select the frame. FrameIndex[CurrentClientId]
Last updated: 2023-10-21
Post by bjarne-pagaard on Multiple WebVisu
CODESYS Forge
talk
(Post)
You can use the switch frame variable, but there should be a variable for each active visu user. You can put the switch frame variable in an array, and use CURRENTCLIENTID as index into the array to get what you want. The CURRENTCLIENTID is assigned to new users automagically by the Visu Management.
Last updated: 2024-03-14
Documentation / Usage Help For Scripting Engine Libraries
CODESYS Forge
talk
(Thread)
Documentation / Usage Help For Scripting Engine Libraries
Last updated: 2023-08-21
Strong Private Key Protection for Encryption Certificates
CODESYS Forge
talk
(Thread)
Strong Private Key Protection for Encryption Certificates
Last updated: 2023-08-22
No source code available for profinet library
CODESYS Forge
talk
(Thread)
No source code available for profinet library
Last updated: 2023-08-23
Security Screen - Custom Certificates for OPC UA Server?
CODESYS Forge
talk
(Thread)
Security Screen - Custom Certificates for OPC UA Server?
Last updated: 2023-08-23
CODESYS Automation Server Connector for 3.5 SP11
CODESYS Forge
talk
(Thread)
CODESYS Automation Server Connector for 3.5 SP11
Last updated: 2023-08-30
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.