Post by marks on Siemens G120X via Ethernet/IP CODESYS Forge talk (Post)
The goal is to control a Siemens G120X VFD via Ethernet/IP. The .eds is installed into the device repository. The VFD is added and is using the connection and assemblies from the eds. It appears to reach the VFD but fails to establish a connection. The status message is: Diag String: 'Adapter configured. Open all connections.' The PLC is a raspberry pi 4, running codesys target version 4.13.0.0. The development environment is CODESYS V3.5 SP21 + (64-bit). Anyone have experience with this combination? Alternately, where should I look next? Thank you, Mark
Last updated: 2025-05-06

Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project CODESYS Forge talk (Post)
I want to run the following command by linking it to the A-Axis: G01 A45.0 Which TRAFO should I use to do this? SMC_TRAFO_5Axes and SMC_TRAFO_GantryCutter3 function blocks did not work! For example, when SMC_TRAFO_5Axes is used, parameters B and C can be resolved by the transformer. However, parameter A cannot be resolved. Only SMC_Interpolator displays the value of parameter A in the SMC_Interpolator => piSetPosition.dA output. Should I drive this axis with SoftMotion commands (MC_MoveAbsolute etc.)?
Last updated: 2025-05-07

Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project CODESYS Forge talk (Post)
Solutions: * https://content.helpme-codesys.com/en/libs/SM3_CNC/Current/SM_CNC_Data-types/SoftMotion-CNC/SMC_POSINFO.html * https://content.helpme-codesys.com/en/CODESYS%20SoftMotion/_sm_example_external_axes_usage.html
Last updated: 2025-05-07

Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project CODESYS Forge talk (Thread)
Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project
Last updated: 2025-05-07

Post by pernockham on Engineering IDE from linux? CODESYS Forge talk (Post)
I have done the switch (linux mint, virtual windows through QEMU/KVM) now and is generally pleased. Have had problems in two areas initially. To bridge IP to the Virtual unit (solved), I overthought things initially. Solution. Configure manually a bridge in the mint-"network connections". Use that bridge in the Qemu settings as "Bridge device", "Device name": "name of the configured bridge" Figure out where to store the projects. I started out have the data in linux world (sort of) and linking it the windows with "virtio-fs". That had some serious impact though on git-handling. It seems that virtio-fs interpreted any file-path as lowercase only even if there were uppercase, resulting in git not able to sync files between its repository and the source code (it created a new file-path for me with only lowercase). Then I switch to samba-share instead and this works much better, though (git-actions) is a part that still has low performance with lots of waiting for file-actions. What should be the best way of handling the source/git? Edit to answer myself: Save the project "locally" in windows, then a lot of slow performance is avoided. Then a git-remote sync for backup.
Last updated: 2025-05-08

Cannot Find "Automatically Generate POUs" Option CODESYS Forge talk (Thread)
Cannot Find "Automatically Generate POUs" Option
Last updated: 2025-05-08

Post by patliby on Cannot Find "Automatically Generate POUs" Option CODESYS Forge talk (Post)
I would like to enable the feature to automatically generate POUs for Project/Library properties in some of my library/project files. The Codesys help pages indicate it should be on the bottom of the Project Information Summary tab, but mine has no such options (see screenshot). Is there somewhere I have to enable this overall feature or any other prerequisite I am missing? I am using Codesys 3.5.19.20 Reference https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_obj_project_information.html#UUID-9ddc3572-a024-5a49-c0c1-31677991a419_id_c95bfe46c6c18a67c0a8640e01715107_id_0a188ec6fa561b9fc0a8640e0019d8bf
Last updated: 2025-05-08

Post by sercan on Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09

Post by sercan on Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09

Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Thread)
Does G75 work when SMC_NCInterpreter is used?
Last updated: 2025-05-09

Post by sercan on Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09

Post by sercan on Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09

Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Thread)
Does G75 work when SMC_NCInterpreter is used?
Last updated: 2025-05-09

Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Thread)
Does G75 work when SMC_NCInterpreter is used?
Last updated: 2025-05-09

Post by ellocco on Kann mich nicht am Gerät anmelden CODESYS Forge talk (Post)
Nachdem ich einige Zeit unbehelligt arbeiten konnte, bin ich wieder ausgesperrt, Deinstallieren und Neuinstallation der Nachfolgeversion (SP21) hat nichts gebracht und der Trick, der unter SP18 funktioniert ist mittlerweile verbaut (wie bereits geschrieben). Gibt es evtl. in der Registry einen Ort, an dem ich etwas löschen muss / modifizieren kann?
Last updated: 2025-05-09

Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Thread)
Does G75 work when SMC_NCInterpreter is used?
Last updated: 2025-05-09

Post by sercan on Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Post)
When a G75 command is received in a SoftMotion+CNC project, SMC_NCInterpreter does not generate any error commands, but the command does not continue execution! There is information about SMC_NCDecoder in the documentation of the G75 command. Is this command only supported by SMC_NCDecoder? Can the G75 command be used with SMC_NCInterpreter? Forexample: G75 ; RUNNING G01 X$Settings.X$ Y$Settings.Y$ Z$Settings.Z$ ; - G75 ; - G01 X100.0 Y200.0 Z300.0 ; -
Last updated: 2025-05-09

Does G75 work when SMC_NCInterpreter is used? CODESYS Forge talk (Thread)
Does G75 work when SMC_NCInterpreter is used?
Last updated: 2025-05-09

Post by eschwellinger on Kann mich nicht am Gerät anmelden CODESYS Forge talk (Post)
nein seid 3.5.20.10 ist einfach hier: c:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\XXXXXXXX\
Last updated: 2025-05-09

Kann mich nicht am Gerät anmelden CODESYS Forge talk (Thread)
Kann mich nicht am Gerät anmelden
Last updated: 2025-05-09

Siemens G120X via Ethernet/IP CODESYS Forge talk (Thread)
Siemens G120X via Ethernet/IP
Last updated: 2025-05-13

Post by marks on Siemens G120X via Ethernet/IP CODESYS Forge talk (Post)
Does anyone know the internals of Codesys well enough to interpret the diagnostic string?
Last updated: 2025-05-13

Post by glutenaron on Safety drive EL6900 and mitsubishi CODESYS Forge talk (Post)
Hi, Im wokring to get my servo mitsubishi mr-j5-g40-rnj1 working with my safety drive. I have as you can se in the picture Ek1100 koppler and EL6900 as safety plc. My questien is how do i connect the safety_drive to the SM3_Drive_ETC_Mitsubishi_MelServo_J5_Axis1 down below? I get the error ((Logical I/Os]: The logical device 'Safety_Drive' is not mapped to any physical device.)) but how do i map this? regard
Last updated: 2025-05-13

Post by mondinmr on Unexpected behavior in cyclic encoder read method during INT overflow (wrap-around) CODESYS Forge talk (Post)
Hi everyone, I’m investigating a potential issue with a cyclic method we use for reading incremental encoders in our libraries. I’ve come across two implementations that, at first glance, appear to perform the same operation: motionUnit.vlPositionActualValue is UINT due strange encoder type. Version A METHOD PROTECTED cyclicReadField VAR_INST actPosFieldOld: INT; rI: INT; delta: INT; END_VAR rI := TO_INT(motionUnit.vlPositionActualValue); delta := rI - actPosFieldOld; m_actPosRaw := m_actPosRaw + TO_LREAL(delta); actPosFieldOld := rI; IF settings.velocityFeebackMapped THEN m_actVelRaw := TO_LREAL(motionUnit.velocityActualValue); END_IF Version B METHOD PROTECTED cyclicReadField VAR_INST actPosFieldOld: INT; END_VAR m_actPosRaw := m_actPosRaw + TO_LREAL(TO_INT(motionUnit.vlPositionActualValue) - actPosFieldOld); actPosFieldOld := TO_INT(motionUnit.vlPositionActualValue); IF settings.velocityFeebackMapped THEN m_actVelRaw := TO_LREAL(motionUnit.velocityActualValue); END_IF Both use INT and the same delta logic, so they seem equivalent. However, when an overflow (wrap-around) occurs, version A continues correctly as expected, while version B unexpectedly resets to -32768 without a clear reason. Has anyone experienced similar behavior or can shed light on what might be happening here? It almost seems as if the cast to LREAL is being applied before the calculation — but that would be illogical and potentially very dangerous in many situations! Thanks!
Last updated: 2025-05-13

Post by glutenaron on Safety drive EL6900 and mitsubishi CODESYS Forge talk (Post)
Can also mention target version 4.15 codesys 3.5 SP21 (64bit) EL6900 version 4.0.3.0
Last updated: 2025-05-13