Post by pethun on Upgrade from codesys 3.5.19 to 3.5.20 CODESYS Forge talk (Post)
Hi We upgraded our ptoject from 3.5.19 to 3.5.20 but we get an error message in the latest version. We made our own trend function and its related to this we get error message: Trend_Menu Device: PLC Logic: Application: C0032: Cannot convert type 'RTS_SYSTIMEDATE(systimertc, 3.5.20.0 (system))' to type 'RTS_SYSTIMEDATE(systimertc, 3.5.17.0 (system))' The variables are defined as follow: start : SysTimeRtc.SYSTIMEDATE; end : SysTimeRtc.SYSTIMEDATE; The code that creates the error is the variable start and end IF xAssign THEN xAssign := FALSE; xPanEnable := FALSE; xZoomEnable := FALSE; drs.liFrom := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(start, 0 (us)); drs.liTo := VisuTrendStorageAccess.TrendStorageConvertToTimestamp(end, 0 (us)); drs.m_itfDateRangeSelectorClient.SetCurrentRange(drs.liFrom, drs.liTo); END_IF I cant understand really what the error message means and what can be the cause of the error? It compiles fine in dthe older codesys 3.5.19. If anyone has some experience of this please help us out? We must upgrade due to the new licenses. Thanks
Last updated: 2024-04-20

Post by m83coding on Raspberry Pi Codesys SPI Master CODESYS Forge talk (Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23

Post by reinier-geers on License problem gateway CODESYS Forge talk (Post)
16.4 Epis What has it to do with the manufacture? It just a licence more not. So basicly the idee of codesys sucks. 3s acts like its posible to add a license. And then it depence on the manufacturer. Why ?? Its a computer !! has nothing to do with the manufacturer. Most dont what a basic licence because they have to pay for that. 3s is the problem not the manufacture of the hardware. Its like the licence of the raspberry pi. HMI is not working. Sorry you get a refund. Why suggest that its possible wen its not !!. It cost me a lot of time. Who pays my time. Why do i have to pay for somting thats not working.
Last updated: 2024-04-26

Post by amy123 on Any guides on using Codesys containers in Docker? CODESYS Forge talk (Post)
I had an issue aswell, I was trying to use docker and got stuck on the specific line ' Downloading https://download.microsoft.com/download/9/5/A/95A9616B-7A37-4AF6-BC36-D6EA96C8DAAE/dotNetFx40_Full_x86_x64.exe' within install2.sh - which is actually from the https://raw.githubusercontent.com/Winetricks/winetricks/master/src/winetricks, winetricks_selfupdate(). Would love to know if anyone has a known solution. Only other thing I can think is to download winetricks +.net, update the winetricks to point to the downloaded .net? Granted Im not too savy with Docker so I have been struggling on figuring that part out- would love any suggestions!
Last updated: 2024-05-19

Post by stewnguth on New License not working. CODESYS Forge talk (Post)
Hey there, I am pretty new to the codesys space, but I got a codesys control basic M license for my raspberry pi that isntalled with no problem yesterday. Today, I went to install the visualization M locense as well because I went over the variable limit and am getting a "servernotfound" error in codesys when attempting to activate. I also tried to follow the advice in some other threads and install using a license request file on the web interface but am getting a message saying "An internal error occured" when attempting to install the license. Can anyone help me get this up and running? Thanks for your time.
Last updated: 2024-05-23

Post by robpqs on Program from one PLC to other WAGO 750-8204 CODESYS Forge talk (Post)
Hello, You use the WAGOUpload tool. You can download it on the download center of WAGO. Make a backup and restore it on the new device. (if can check the remanent data to copy the persistent variables if necessary) You can also use a SD card, go to the WBM copy it the image to the SD card and restart the other controller on the SD card. In the WBM, copy it back to the internal flash. If you contact your local Wago office, they will more than probably help you. There is also a WAGO forum. RP,
Last updated: 2024-05-27

Post by mborchert on PFC100 Error "Bus not running" CODESYS Forge talk (Post)
Hello, i currently want to use a wago 750-8102 with the "codesys control for pfc100" runtime. I want to add the devices connected to the internal pfc100 bus via the "search devices" tab. This was reccommended in the following thread: https://forge.codesys.com/forge/talk/Deutsch/thread/7701332199/ But whenever i try to search for devices codesys just doesnt find anything and i cant close the "search devices" window. Has anyone got an idea what the problem might be? I already tried adding the devices connected to the pfc100 manually but the bus just doesn´t start. best regards Moritz
Last updated: 2024-06-17

Post by imdatatas on Unrecoverable SoftMotion state after switch to PreOp CODESYS Forge talk (Post)
Dear @alimans, Additionally, As far as I know since starting from Softmotion V4.18.0.0 automatic restart behaviour for an axis has been changed for this issue. See below explanation from release notes. "With CODESYS SoftMotion 4.18.0.0, the behavior of SoftMotion axes after a loss of communication to the servo drive has changed. Now, an automatic reinitialization is performed as soon as the communication is established again. Before, an explicit call to SMC3_ReinitDrive had to be performed. An example for a loss of communication is that the cable to one of the drives is unplugged." Regards, imdatatas
Last updated: 2025-10-23

Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem CODESYS Forge talk (Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27

Post by uluking on CodeSys2.3 Modbus 64-Bit Double Read Problem CODESYS Forge talk (Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I am reading data from a Siemens PAC3220 energy analyzer using Modbus with Wago-8202. However, the device's energy indices are given as doubles. Since a double variable is 64-bit, it is not possible to read it directly. I have been struggling for days, I have written many conversion functions but I have not been able to get results. I would appreciate your help. I read 4 word variables and processed them. I am converting them according to IEEE-754, but I can't seem to read the correct data. I would appreciate your help.
Last updated: 2025-10-27

Post by mini-developer on Precompilation Error NBS.UDP_Peer CODESYS Forge talk (Post)
Hello, I use the Library NBS from "caa net base services". After opening the Project i get 19 errors from the message window "Precompilation", most of them because it doesn't recognise a component of the FB "NBS.UD_Peer". (see photo) After compiling the Project at least 2 times, there are no errors. Is there a reason and solution for this behavior? Is there a problem with resolving the library? Thanks for any clue
Last updated: 2024-08-23

Post by k4zz on Statisch Code Analyse ausführen via Python CODESYS Forge talk (Post)
Derzeit arbeite ich daran, statische Codeanalyse in unsere (CI/CD)-Pipeline zu integrieren. Konkret habe ich die statische Codeanalyse erfolgreich für .project-Typen durchgeführt, und sie funktioniert einwandfrei. Allerdings habe ich Schwierigkeiten bei der Ausführung derselben für .library-Typen festgestellt. Hierbei habe ich zwei Methoden ausprobiert: system.commands["staticanalysis", "run"].execute() # get Project values myProject = projects.primary # Creates an active application app = myProject.active_application # build Application and run static code analysis app.generate_code()
Last updated: 2024-03-18

Post by dekelec on Request for IFM ecoPlus21 installation package CODESYS Forge talk (Post)
Hello, I’m looking for the ecoPlus21 development environment used with early IFM controllers (e.g., CR0020_Q firmware). We have an old project created in ecoPlus21 that cannot be opened in CoDeSys 2.3, and IFM no longer provides this software. If anyone still has the ecoPlus21 installer or knows where it can be downloaded, please let me know. It’s needed only for recovery and migration of an existing project. Thanks in advance,
Last updated: 2025-10-17

Post by rossanoparis on Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container CODESYS Forge talk (Post)
System information - Controller: KUNBUS RevPi CONNECT-S - OS: Linux buster 32bit 5.10.103-rt62-v7l #1 SMP PREEMPT_RT armv7l GNU/Linux - CODESYS v3.5 SP19 Patch 2 I'm facing a problem related to codesys licences using a procedure based on a bash script. Such bash script detect the presence of new .deb files and install them on system. My automation solution don't allow to be maintained by dedicated personal, thus even the CODESYS runtime SW must be installed using an "automatic" procedure instead of using the CODESYS tool. remark I've been using the following procedure since the runtime v4.5 without any issue. Before installing the new runtime packages, I need to copy the file CODESYSControl_User.cfg (here attached) because of new section which is necessary to add in order to allow some folders to be written by CODESYS runtime v4.9 Up to now, this has been unnecessary, this is the main difference between my previos bash file and the new one. remark If I skip this action, everythings goes fine, but my CODESYS application can't work as it needs to access some folders on controller's file system. Process - Before the procedure: the licenses are OK (see attached file lic-01.png) - After the procedure: the new CODESYS runtime version is correctly installed, but the software container with v1.19 and all licences disappear (see attached file lic-02.png) This is the synthetic content of bash script I'm using. # Stop runtime sudo service codesyscontrol stop sudo service codesysedge stop # Move the new CODESYSControl_User.cfg file # New configuraton with folders declared sudo mv -f CODESYSControl_User.cfg /etc # Install runtime package echo N | sudo apt-get install -y --allow-downgrades codesyscontrol_raspberry_4.9.0.0_armhf.deb # Install edge gateway package echo N | sudo apt-get install -y --allow-downgrades codesysedge_edgearmhf_4.9.0.0_armhf.deb # Reboot controller sudo reboot Thanks in advance
Last updated: 2023-09-19

Post by manuknecht on Opening a Dialog on a specific Client from ST CODESYS Forge talk (Post)
I managed to find a solution that seems to work reliably. As the VU.Globals.CurrentClient-filter accesses the CURRENTCLIENTID or at least a similar, internal variable it can only be used if called from a certain client (e.g. from a button in a visualization). My solution works by implementing a new client filter that compares the client ID of all clients to the ID of the last client that was used. The variable containing the data of the last client is defined as: G_LastClient : VU.IVisualizationClient; // Copy of last client that detected click This last client is then updated every time a button is pressed using the Execute ST-Code input configuration of the button: G_LastClient := VU.PublicVariables.Clients.Current; Next, I created a function block that implements the client filter interface as so: FUNCTION_BLOCK FB_LastClientFilter IMPLEMENTS VU.IVisualizationClientFilter VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR END_VAR Then i added a method to the FB called IsAccepted which is used to filter out the client. When creating the method, it should automatically be filled with the according variable declaration, as it is defined in the interface: (* For every client can be desided, if it is accepted. ``TRUE``: Client is accepted*) METHOD IsAccepted : BOOL VAR_INPUT (* The client, to check*) itfClient : VU.IVisualizationClient; END_VAR Now the client can be compared to the last used client as such: // check if clientID corresponds to clientID of last recorderd client IF itfCLient.ClientId = G_LastClient.ClientId THEN IsAccepted := TRUE; ELSE IsAccepted := FALSE; END_IF To make use of this custom client filter, initialize a variable with the client filter: LastClient : FB_LastClientFilter; // Client filter to find last used client Then use this client filter when opening or closing a dialog from ST: fbOpenMyDialog(itfClientFilter:=LastClient,xExecute:=TRUE,sDialogName:='VIS_MyDialog_DLG');
Last updated: 2023-09-27

Post by to-ke on Errors with VisuUserManagement library CODESYS Forge talk (Post)
Hallo zusammen, hi all, ich habe den gleichen Fehler. Auf einem Raspberry Pi geht der Fehler weg, wenn ich alles bereinige und dann vollständig übersetze. Wenn das Projekt im Codesys Development System wieder neu geladen wird ist der Fehler aber wieder da. Mit eine Win V3 x64 PLC kann ich den Fehler nur unterbinden wenn ich auf der HMI das VUM_Login einbinde. Dieses brauche ich aber nicht, da ich die HMI für das User Management selbst gestaltet habe. Das funktioniert auch. I have the same error. On a Raspberry Pi the error goes away if I clean everything and then compile completely. When the project is reloaded in the Codesys Development System, the error returns. With a Win V3 x64 PLC I can only prevent the error if I integrate the VUM_Login on the HMI. But I don't need this because I designed the HMI for user management myself. That works too. Anyone have an idea to fix this problem. Many thanks
Last updated: 2024-07-09

Post by salvatorethomas on Port instantiation of serial interface in WAGO PLC using Modb_L05.lib in CoDeSys v2.3 CODESYS Forge talk (Post)
Hi — good description of the problem. A few suggestions / questions that might help narrow this down: Since your first serial port (COM2) works fine but the second (COM4 + MODBUS_EXT_MASTER) never opens, check whether the two ports are truly independent — some WAGO modules share internal resources, so COM4 might conflict with other functions or modules. Make sure that the physical wiring and module configuration for the second port (baud rate, flow control, RS-485 vs RS-422, etc.) exactly match what the library expects — a mismatch in flow control or wiring could prevent port opening even if the LED signals seem OK. Try using a plain SERIAL_INTERFACE on COM4 first (like you did for COM2) without Modbus logic — if that opens, you know the hardware + port config is fine, so the issue is more likely with modb_L05.lib. If the port opens but Modbus still fails, enable debug/logging (if available) to inspect whether the port opening fails or the subsequent Modbus negotiation fails. If you like — I can share a minimal example project I used with WAGO + COM4 + Modbus that worked; you could adapt that to test your setup. Wacky Flip
Last updated: 2025-12-01

Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"? CODESYS Forge talk (Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19

Post by peterkcontrols on TargetVisu started in windowed or not full screen CODESYS Forge talk (Post)
Thanks for the response. I have found this file in two places, I have updated the text in both but it didnt work. Am I missing something on the Codesys side. How do you restart the soft plc, I have been stopping it and starting it. The Visu screen come up but still in full screen mode. Here are the two locations of this file: C:\Program Files\Codesys Control\GatewayPLC\AppDataFiles\CODESYSControlWinV3x64 and C:\Program Files\CODESYS 3.5.20.50\GatewayPLC\AppDataFiles\CODESYSControlWinV3x64 Here is the contents of targetvisuextern.cfg [ComponentManager] [CmpTargetVisu] ; The Window... settings can be used for displaying the targetvisualization in a window instead of fullscreen WindowType=0 WindowPositionX=0 WindowPositionY=0 WindowSizeWidth=1024 WindowSizeHeight=768 HideCursorCompletely=1 [SysWindow] ;Windows.CloseOnAltF4=0 ;Windows.CloseOnWM_CLOSE=0 [CmpLog] ;Logger.0.Name=TvExtLogger ;Logger.0.Enable=1 ;Logger.0.MaxEntries=1000 ;Logger.0.MaxFileSize=5000 ;Logger.0.MaxFiles=3 ;Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut ;Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file ;Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog
Last updated: 2025-02-26

Post by dekelec on Codesys 2.3 & Peak PCAN CODESYS Forge talk (Post)
I use Peak USB adapter daily to download from CoDeSys 2.3 and 3.5 to IFM, EPEC and other controllers. The process: - First you need to install the appropriate driver. Link: https://www.peak-system.com/Drivers.523.0.html?&L=1 - Restart the computer - Start the CoDeSys application - Change the name of the adapter in Communication parameters, as mentioned in previous comment. Write the name exactly as written "Peak_USB", as it could also be case sensitive (defines which .dll file to use). If this doesn't work I would contact the vendor of the controller to find out the procedure. In the attachment I've added a FAQ document from IFM regarding using PCAN USB. P.S. I've noticed in your picture of communication parameters a channel via TCP/IP is mentioned. In this case a USB to CAN connection is not being used. First you should change the channel/gateway to connect via CANbus or connect using an Ethernet cable.
Last updated: 2024-07-09

Post by tyronnosaurus on ReceiveWatchdog FB not working on J1939 P2P PGNs CODESYS Forge talk (Post)
Hi guys. I've got a device that sends a status message over J1939 and a PLC running Codesys to receive it. This message uses a P2P PGN (as opposed to a broadcast PGN). Codesys can only read it if I mark the J1939_ECU as "Local" (see screenshot 1). The message is received correctly, that is not the problem. The problem is detecting if the message stops being received. Local ECUs have no Watchdog checkbox to detect if the message has been received in the last X seconds. In order to implement a watchdog, I've used a ReceiveWatchdog FB. The same code works well for any non-P2P message, but doesn't work for this particular P2P message I'm trying to monitor. Even if I physically disconnect the device, ReceiveWatchdog.xBusy stays True, and ReceiveWatchdog.xError never triggers due to a timeout error. Is there any caveat in the ReceiveWatchdog FB that makes it unable to monitor P2P PGNs in Local J1939_ECUs?
Last updated: 2024-07-11

Post by faceplant on CmpDynamicText unresolved references CODESYS Forge talk (Post)
Hello! I am new to codesys so I am sorry if this is not the right place to ask this question. I am using codesys V3.5 SP20 Patch 1 + (64-bit) and a Groov EPIC PLC (GRV-EPIC-PR2). I am trying to build and deploy my application to the PLC, but when I log in I get 6 errors (codesys_error.png). It seems that the errors have to do with the CmpDynamicText system library which I have as version 3.5.20.0. I have tried to add CmpDynamicText to the ComponentManager section in the PLC's CODESYSControl.cfg file as described in this forum post and still hit the same error. I noticed that the library is grayed out in the library manager, which I think might be the issue. However I don't remember if it was grayed out before I encountered this issue. Please let me know if I can provide anymore info. Thank you!!!
Last updated: 2024-07-19

Post by aliazzz on Unable to deploy Virtual Control SL on ARM64 (Raspberry Pi5) CODESYS Forge talk (Post)
Hi, I have successfully deployed "Virtual Control SL" on a few x86/64 machines now. However, I'd now like to deploy this to a Raspberry Pi (ARM64). To do this I prepared the Raspberry Pi5 with the following prereq's; * Minimal PREEMPT Debian * Latest Bootfirmware * full SSH access via non-root account * Podman * RedHat Cockpit with CODESYS LicensServer plugin up and running However, I can't seem to resolve copying the correct (deploy) Images as they wont show up in the CODESYS IDE I have added CODESYS Virtual Control for Linux SL and the CODESYS LicenseServer for Linux SL via the CODESYS installer on my DevBox. I open CODESYS > Tools > Deploy Control SL Next I enter the SSH targets IP and Credentials and for my RPi5 and it shows "Connected". In the next tab, Deployment, the dropdown box only shows one (1) image, which also is the incorrect CPU architecture. Only Virtual Control AMDx64 shows up (!?) while I expect to see the ARM64 based images for both Edge and Control. Has someone encountered this too? I'd like to hear other people experiences with Virtual Control deployment on ARM based architecture. attachment 1: AMD64 based deployment pulldown menu (correct images) attachment 2: ARM64 based deployment pulldown menu (incorrect images) regards,
Last updated: 2024-07-28

Post by imdatatas on Auto Declare window disappears by itself in the Ladder editor CODESYS Forge talk (Post)
Hello Everyone, The "Auto Declare" window disappears by itself in the Ladder editor. For example, a new function block is wanted to be added to the Ladder editor. (For example; MC_Jog block and instance name will be fbMcJog). To do this, "Empty box with EN/ENO" is added to the ladder line from the Toolbox on the right and when you type MC_Jog in the empty box and press enter, normally the "Auto Declare" window appears and you are expected to be asked to write the instance name here. However, this "Auto Declare" window closes itself immediately, it does not wait for the user to enter a value or close the window. I often encounter this situation in many IDE versions. Does this seem like a bug? If anyone has encountered a similar problem while creating a new program name, function or function block instance name regarding the "Auto Declare" window and knows a solution, I would be glad if you could share it. Best wishes Imdat
Last updated: 2025-03-06

Post by pikebuster on Help for a newbie CODESYS Forge talk (Post)
Can somebody help me with this? I have problem with the button! This task must be solved using Sequential Function Chart (SFC), IEC 61131-3. TASK Create an SFC program to control a traffic light at an intersection. Description: You will program a traffic light that has three phases: Green, Yellow, and Red. The traffic light must follow these rules: Green light is on for 10 seconds. Yellow light is on for 3 seconds. Red light is on for 10 seconds. If the pedestrian button is pressed, the system must keep the red light on for 20 seconds during the next cycle. After the pedestrian has “crossed,” the system should return to its normal cycle. Basic Steps: Initialization: Start by setting the traffic light to Red. Green Phase: After 10 seconds, switch to Green. Yellow Phase: After 10 seconds in the Green phase, switch to Yellow. Red Phase: After 3 seconds in the Yellow phase, switch back to Red. Loop: Repeat the cycle. Use, for example, lamp symbols in the visualization module to simulate the traffic light. You may also add a simple pedestrian light if desired.
Last updated: 2025-03-11