Post by imdatatas on String length issue in GetRecipeNames method
CODESYS Forge
talk
(Post)
Hi, If the string length in the GetRecipeNames method is lower than the default value, there will be a problem with the resulting Recipe file names. For example; When the method in the link is called, let's say the defined string length is 19. In this case, the string content is corrupted as in the image. strArr: ARRAY[0..9] OF STRING(19); https://content.helpme-codesys.com/de/libs/Recipe%20Management/Current/pou-RecipeManCommands/GetRecipeNames.html The same problem does not occur when the string definition is made in the default size. strArr: ARRAY[0..9] OF STRING; FYI Regards, Imdat
Last updated: 2025-02-19
Post by imdatatas on String length issue in GetRecipeNames method
CODESYS Forge
talk
(Post)
Hi, If the string length in the GetRecipeNames method is lower than the default value, there will be a problem with the resulting Recipe file names. For example; When the method in the link is called, let's say the defined string length is 19. In this case, the string content is corrupted as in the image. strArr: ARRAY[0..9] OF STRING(19); https://content.helpme-codesys.com/de/libs/Recipe%20Management/Current/pou-RecipeManCommands/GetRecipeNames.html The same problem does not occur when the string definition is made in the default size. strArr: ARRAY[0..9] OF STRING; FYI Regards, Imdat
Last updated: 2025-02-19
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Apparently my construction will not work as any of the sub-types are not be able to accept any (further) value-initiation. Ie: string_item : log_data_base := (string_value := 'test', val_type := STRING_); is not eq to (the string_value will not be assigned): string_item_2 : log_data_string := (string_value := 'test'); Because effectively for the compiler this is eq. to a "double" assignment where the compiler sees only the first assignment (my guess). string_item_2 : log_data_base := (val_type := STRING_) := (string_value := 'test'); Im not sure this should be treated as a bug, but it would surely be nice to be able to use this construction (compiler is 3.5.20.40). Anyone see any other alternative for solution (other than 4 complete STRUCTS with all fields individually defined)?
Last updated: 2025-03-07
Post by milosfejgl on Codesys Licenses - How to reload them after updating the Raspberry Pi OS
CODESYS Forge
talk
(Post)
We use several control units running on Raspberry Pi, programmed using Codesys software, with multiple licenses stored as soft containers. We are planning to update the SD card image of the Raspberry Pi to a newer OS version. However, we are concerned that this process might result in the loss of our soft container licenses. Is there a way to temporarily deactivate the license so that it can be reactivated on the updated system? Alternatively, what would be the best method to preserve the licenses during the update? Thank you in advance for any responses!
Last updated: 2025-03-13
Post by jampid on Struct Literal
CODESYS Forge
talk
(Post)
Bonjour Davidmic, Il n'est pas possible d'associer une méthode à une fonction. Cela est possible sur les Blocs fonctions. En utilisant ta DUT MyStruct, je créé une fonction avec en entrée un tableau de structure :** FUNCTION F_F3 : REAL VAR_IN_OUT // bien définir un type IN_OUT IN_ptrINT: ARRAY[*] OF MyStruct; // la taille sera définie ultérieurement/ END_VAR VAR _di: DINT; // Index de parcours du tableau pour l'écriture dans les cases ENDVAR ============== //Programme F_F3: FOR _di := LOWER_BOUND(IN_ptrINT,1) TO UPPER_BOUND(IN_ptrINT,1) DO IN_ptrINT[_di].som:=IN_ptrINT[_di].a + IN_ptrINT[_di].b; END_FOR J'utilise ensuite cette fonction dans un POU Programme : PROGRAM Test_F_Fx VAR _aiTAB9:ARRAY[0..3] OF MyStruct := [(a := 1, b := 1.2), (a := 2, b := 2.2), (a := 3, b := 3.3), (a := 4, b := 4.4)]; END_VAR ** ==========** F_F3(IN_ptrINT:=_aiTAB9 ); Voilà l'idée pour avancer. Une autre idée, est d'utiliser les pointeurs ou les références. Bon développement!
Last updated: 2025-04-07
Post by viksym on How to get the motor scaling value from code
CODESYS Forge
talk
(Post)
If anybody finds this in the future, I managed to do it like this: scalingValue := EncoderPulseCountPerRev / ABS(AxisName.fScaleFactor); No need to use MC_ReadParameter as I am able to read this value directly from the axis object. Using an absolute value of the fScaleFactor is there in case the axis is set as inverted, in which case it would be a negative value. I was not able to figure out how to get EncoderPulseCountPerRev programatically, but since all my servos use an encoder with pulse count per revolution of 16#800000, the final equation looks like this: scalingValue := 16#800000 / ABS(AxisName.fScaleFactor);
Last updated: 2025-08-19
Post by ignat on Change date range of Trend
CODESYS Forge
talk
(Post)
Hi ryusoup, looking for the same functionality. I tried to use your code but couldn't figure out all the details. to enable Listener should it be called once or cyclically? the listener should be called with the intance of FB which you described? should it be this instance to be called cyclically too? I tried to make it simpler, just force the uiYear/uiMonth etc. but couldn't make it work. Could you please share some details how the whole struckture looks like? Would be great if you share an example UPD: found the issue. Your code works. Thanks for the posts
Last updated: 2024-01-17
Post by sumit on Not able to see input data coming from eip adapter on codesys
CODESYS Forge
talk
(Post)
dhumphries, I changed the datatype this time from BYTE to USINT (because that's what my adapter is sending: array of uint8_t). The text "New Help String" you saw in previous screenshots is just the description of the input/s (it can be anything). I also looked into the logs (see attached) for that ! sign next to the device, I found that connection is being timeout. I tried some suggestions from online such as increase the RPI but still got connection timeout issue, also by changing the datatype, I still don't see incoming data from the adapter, although its visible on wireshark. thanks,
Last updated: 2024-03-07
Post by garrian on How to sort JSON object in codesys
CODESYS Forge
talk
(Post)
Hi there, I'm testing out MQTT from my Wago PLC using JSON object. I have managed to publish this {"Temperature":15.6,"Setpoint":38.0} to my broker. Now I', trying to subscribe to the same message. The result is this: '{"Temperature":15.6,"Setpoint":38.0}95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' First, why do I see 95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' at the end of the message? Second, how Can i sort out this data to use it in my program? I followed a youtube tutorial which gave me the attached result, which works. But I need some other smart way of doing this when the object gets even more data in it. Any help is very appreciated :)
Last updated: 2024-05-04
Post by gatto on Modbus tcp - channel
CODESYS Forge
talk
(Post)
Hi can you give more details? Are you talking about a danfoss? wich model? Can post the configuration of channel' I used, on the past, serial modbus with danfoss fc280 I remember ((id x 10)-1) I remember that you couldn't use continuous reading/writing of the directors but you had to use them one at a time. it seemed that reading empty registers (caused by x10) was not accepted by danfoss. So I had created a scan that used just one register, then the next etc etc with a timed interval. But this was for the serial, I don't know if it's the same thing with ethernet. I currently use Ethernet TCP/IP interface with FC280.
Last updated: 2024-06-13
Post by swol on HTML 5 - Controls -> Change Content-Security-Policy settings
CODESYS Forge
talk
(Post)
Sorry for being late to the party... so it is not possible to use the webbrowser tool to display external websites in a visu anymore? As it is not possible to simply "adjust the ContentSecurityPolicyIncludeTrustedOrigins setting in the automatically generated webvisu.cfg.json file" as stated in the docs? We need to display data read from a Raspberry Pi (part of our computer network) in our webvisu. We used to do it by entering the Pi's IP address as the URL variable in the webbrowser element but now (I don't know since when, I'm new on the job) "The page’s settings blocked the loading of a resource (frame-src) at 'IP address' because it violates the following directive: “default-src 'self' 'unsafe-inline'”. What are the options for displaying the data?
Last updated: 2025-11-11
Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE
CODESYS Forge
talk
(Post)
We changed the path where the CSV file is. From intern memory of the IPC to a USB key. We still have this error 'INVALID_HANDLE'. We must restart the Codesys runtime to clear it. That is a big problem for us because machine is in production. @eschwellinger What do you mean by "this is a security issue not to read/write in the plc allowed path"
Last updated: 2023-10-27
Post by ggis on Unable to connect to git remotes through Codesys.
CODESYS Forge
talk
(Post)
When trying to connect to a Github repository in the Git remotes windows of Codesys, the user can be the account username or the account email, while the password is the Github token. (I know this is an old topic, but I lost some time figuring it out from the guides.)
Last updated: 2023-11-10
Post by ewi04 on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
The individual structures were declared in a separate global variable list on a trial basis. But even this did not change the behavior. A total of 1667 variables are processed in a recipe. A reduction (e.g. saving only the first three drive parameter sets) also brought no change.
Last updated: 2023-11-15
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by fazlinda on AWS IoT core CODESYS
CODESYS Forge
talk
(Post)
Hi, Im having a problem sending a data from my structure text code from codesys to aws. Instead of receiving {state {reported {data: 123}}} It display {state {reported {data: 123}}}\x00 \x00 \x00 \x00 \x00 \x00 \x00 Please help me solve this issues. how to remove \x00 ?
Last updated: 2023-12-06
Post by schorge on Modbus RTU Slave
CODESYS Forge
talk
(Post)
Ich würde gerne bestimmt Modbus RTU Slave Adressen auslesen, leider bekomme ich keine Werte vom Bus. Verbindung erfolgt über einen Raspberry mit Modbus RS485 Adapter, welcher erfolgreich verbunden ist. Mit einem IOBroker kann ich die Daten erfolgreich auslesen. In der Modbus_COM_Port => Modbus_Serial_Device habe ich Input Register 4000 %QW und Startadressen auf Input Register 3000, als Variable ein Array[0..2999] of Word, kann aber keine Werte auslesen.
Last updated: 2023-12-06
Post by kevinrn on Signing Packages without exposing the password of the certificate
CODESYS Forge
talk
(Post)
Indeed, I'm also seeking a solution for this issue. The main challenge we face is the requirement to use EV (Extended Validation) Certificates. Due to security considerations, it's not possible—nor is it ever recommended in such cases—to export the certificate with its private key.
Last updated: 2024-08-20
Post by dengsberg on Disable Communications to 'Modbus_Server_COM_Port' from the logic
CODESYS Forge
talk
(Post)
I have a serial Modbus RTU communicating to the Slave device. But when the control system is not in Run there is no power applied to one of the Modbus Devices. Can I enable / disable the communications to that Modbus Slave in the code based on my running mode, so I don't get all the errors?
Last updated: 2024-08-29
Post by thedertom on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
Hi I try to get korean texts out of a textlist. For that I want to use DynamicTextGetTextW, but I am a little confused how it is supposed to work. The function returns POINTER TO STRING, but how do I get WSTRING? I succesfully used DynamicTextGetText with classical Strings. Thanks in advance!
Last updated: 2024-09-02
Post by damian177 on Codesys Control for Linux SL
CODESYS Forge
talk
(Post)
Hi, For many years my application has been running on Raspberry Pi. Now I have ported the application to a PC running with Debian OS with Codesys Control for Linux SL. Most of things works. But some is wrong with serial ports. Firstly , I wonder why /etc/CODESYSControl.cfg in Debian is empty ?