Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables CODESYS Forge talk (Post)
Trying the web-version of trend-data. This seems to be a impressive tool, but I lack/cant find a number of what I would think are important parts. There does not seem to be a way to get away from the dot.notated variable naming in the legend.. A developer might want the dot-notation but an end-customer will surely not. For instance I want to display 12 temperatures, instead of t1, t2 etc.. they will be named. gvl_io.unit[1].trend.temps.t1_a gvl_io.unit[1].trend.temps.t1_b gvl_io.unit[1].trend.temps.t1_c gvl_io.unit[1].trend.temps.t2_a .. gvl_io.unit[1].trend.temps.t4_b.. gvl_io.unit[1].trend.temps.t4_c.. Quite a lot of unnecessary text/data taking space from the actual trend => Is there a way to access/interface the legend-data programmatically so I can change the presentation/naming?
Last updated: 2025-12-16

Post by pernockham on Trend legend naming and access/config to/of trend/legend-variables CODESYS Forge talk (Post)
There seems to have been included an updated in the last release 4.9.0.0 or am I wrong (I think I tried out these settings previously without giving the result I wanted contrary to what I see today)? Now an empty check box for "display variable name" is effective, and will present the Variable with the "Description" instead. Perfect! Seems to be some minor formatting still that needs adjustment. See attached screenshot. The apostrophe "'" between "description" I suppose should not be there? Also I guess the same apostrophe (although not visibly shown) gives an extra space between the variable-description and the ":"?? Thanks!
Last updated: 2025-12-19

Post by dhumphries on Deploy Codesys Control SL to a 'secure' device CODESYS Forge talk (Post)
I have the same problem on a setup where I'm trying to load control SL onto a fresh installation of ubuntu server 22.04 (with sudo privileges,) I've done this in the past several times but only with codesys 3.5.19.x since updating to the new versions I'm having inconsistencies, either I can load the runtime but not login or I can't load the runtime at all. I appreciate there are new releases frequently, but it would be nice if there was a LTS version with some kind of documentation. I'm currently building a VM so I can install version 3.5.19.4 since this was the last version that worked for me. Adding additional versions through codesys installer has been unsuccessful, hopefully a fresh install on a virgin OS will be more successful.
Last updated: 5 days ago

Post by reinier-geers on wEBCLIENT Post data api CODESYS Forge talk (Post)
Ive got the webclient axample. If i put https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e example to https://reqbin.com/post-online then i get data. If i do the same in Webclient example i get " not a valid graphql request. Why ? sUrl := 'https://graphql.frankenergie.nl/' Request_type_post Contenttype = 1 (json ) Postvalue := '{"query":{"query":"query MarketPrices {\n marketPrices(date:\"2025-12-25\") {\n electricityPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n gasPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n }\n}' I tranfer the postvalue from String to WSTRING
Last updated: 2025-12-25

Post by sheberle on No Bootproject possible CODESYS Forge talk (Post)
Hello Alex, the message is generated by the CODESYS code generator based on the DevDesc settings of the memory areas available for the target. The problem arises when after too many online changes the area is full. Therefore no more boot project can be generated. Short-term remedy as described in the dialog: Clean and fresh download. This way the initial memory size will be "used" again After how many online changes did this error occur? There is no set limit on the number of online changes, but making too many changes could be a risk. br Simon
Last updated: 2026-03-31

Post by jroddball79 on PM556-TP-ETH β€” How to change IP address without overwriting the PLC program? CODESYS Forge talk (Post)
Still looking for a solution. I have gathered more information that might help: Device: ABB AC500 PM556-TP-ETH Firmware version: 2.4.2.14993 (dated 2014) Open ports confirmed: 502 (Modbus TCP), 1200 and 1201 (CODESYS runtime). SSH (22) and HTTP (80) are not reachable. No SD card in the PLC. I can connect via Automation Builder using the current IP and Online Login works, but I have no original source project available. Automation Builder requires a full PLC download to apply IP changes, which we want to avoid as it would overwrite the running program. Any guidance on how to change the IP without a full download would be greatly appreciated. I am also open to solutions using third party tools, DCP protocol, or scripts. Thank you
Last updated: 2026-05-22

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by hammer on Cartesian XY Chart β€” 2-D array binding: "Element to use" enumerates the wrong dimension CODESYS Forge talk (Post)
Title: Cartesian XY Chart β€” 2-D array binding: "Element to use" enumerates the wrong dimension; documented example (Dialog: XY Chart Configuration, "Two-dimensional array of base type REAL") appears transposed Product / version: CODESYS Development System V3.5 SP21 Patch 40 (3.5.21.40). Cartesian XY Chart visualization element (System_VisuElemXYChart / VisuElemXYChart). Summary: When a curve's Data X/Data Y is bound to a two-dimensional array, the element treats the last array dimension as the per-point record (the one selected by "Element to use") and iterates the first dimension as the sequence of curve points. The online documentation's worked example has the dimensions in the opposite order, so following it produces a non-functional curve and a nonsensical "Element to use" list. Steps to reproduce (fails β€” matches the documented layout): 1. Declare aData : ARRAY[0..1, 0..4095] OF LREAL; (2 data sets Γ— 4096 points, i.e. first dimension = set, second = point). 2. In XY Chart Configuration, bind a curve's Data X (and Y) Variable to this array. 3. Observe the "Element to use" combobox. Actual result: The "Element to use" combobox lists 4096 entries (the indices of the second dimension) instead of 2 (the data sets in the first dimension). Selecting a row does not produce the expected curve; at most a single/degenerate point is plotted. Steps to reproduce (works β€” transposed): 1. Declare aData : ARRAY[0..4095, 0..1] OF LREAL; (points first, set second). 2. Bind Data X/Y to this array; "Element to use" now correctly lists [0] and [1]. 3. Populate aData[point, set] and the curve plots as expected. Expected result: Either the documented example should select the data set from the first dimension (as its [1]/[2] "Element to use" implies), or the documentation should state that the last dimension is the record dimension (stride) and the first dimension is the point sequence β€” consistent with how the element actually behaves. Analysis: The behavior is self-consistent if the element always walks a single array by a fixed byte stride, reading one element per point β€” the same mechanism as the documented "one-dimensional array of a DUT" case, where it strides by SIZEOF(DUT) and "Element to use" picks the member offset. For a 2-D array the record is the last dimension: to plot column/set c it starts at [0, c] and strides by the last-dimension length to reach [1, c], [2, c], … (row-major layout makes this a contiguous column walk). Under that rule, ARRAY[0..N, 0..1] is correct (record length 2 β†’ "Element to use" [0]/[1]), and the documented ARRAY[1..2, 1..50] with "Element to use" [1]/[2] is transposed. Documentation reference: Dialog: XY Chart Configuration β†’ Data X / Data Y β†’ "Example: Two-dimensional array of the base type REAL" (ARRAY[1..2, 1..50], Element to use [1]/[2], "100 array values are displayed"). This example does not plot as described in 3.5.21.40; transposing to ARRAY[1..50, 1..2] does. Request: Please confirm whether this is (a) a documentation error (example dimensions reversed) or (b) an element defect (combobox enumerates the wrong dimension). Either way, a corrected example plus an explicit statement of which dimension is the point sequence vs. the record/stride dimension would prevent others from hitting this. Two separate 1-D arrays for Data X and Data Y work correctly and are unaffected.
Last updated: 21 hours ago

Post by pernockham on Gateway in China - "Gateway not connected" CODESYS Forge talk (Post)
I think I understand my problem. They are most probably related to configuration of the network. When I use DHCP for the unit to my router it all works. However when using static IP I have not managed to reach functioning state. Trying to replicate the situation on my desk. Having a static IP on the "debian host" and a connection to my computer which then routes traffic on to internet. I have entered settings for gateway and netmask. I can ping from my "debian plc host" to internet and also do "curl google.com" so traffic seems to find its way through and back, still "Automation server" will not find the gateway. Any hints how a manual configuration should be done? Is it possibly a "firewall" issue of my "normal router"? Thanks for any help! Per
Last updated: 2026-01-27

Post by gatto on Two licenses have to be installed forgot to enable one license CODESYS Forge talk (Post)
Sorry, I've never used Raspy. Maybe someone else can help. From personal experience, I've had license activation issues, but it was caused by my company firewall, which was blocking traffic from the Codesys license server. So I found that the license was listed as activated on the server (and therefore used and no longer activable), but it wasn't present in the PLC. I solved the problem by using an unblocked internet connection when I needed to activate the purchased license ticket. Since then, the activation process has always worked, and I've never lost any licenses.
Last updated: 2026-02-03

Post by dvmaris on Control for Linux ARM64-User Management issue CODESYS Forge talk (Post)
I'm trying to work with Codesys Control for Linux ARM64 SL 4.18.0.0 on a Toradex Verdin NXP iMX8MP. I have the runtime installed and operational as well as Codemeter lite 8.40.7141.503 (arm64). I'm running 3.5.20.60 and when "Scan Network" I see the Verdin popup. When I try to connect to it, the "mandatory use of the user management" popup shows...which makes sense. I click YES and enter user information and click OK. It immediately displays a "No device is responding to the scan request" popup. The IDE can see the Verdin in the scan...so this popup does not make sense to me. I thought maybe it was a read only issue but I've made all partitions and paths RW. Has anyone experienced this? Can anyone tell me where it is trying to write user data?
Last updated: 2026-02-11

Post by gseidel on CAM Motion Recover after STO CODESYS Forge talk (Post)
Dear Mr. Kolev, I'm not sure I understood correctly. But this is my take on your question: When the STO of the slave is triggered, store the current master position (e.g. 225 units) After the reset of the slave error, call MC_SetPosition on the virtual master and reset it to the stored position (225 units) Optionally, before MC_CamIn is restartet, move the slave back to the slave position corresponding to the stored master position. (If you do this, no ramping in will be necessary) Restart MC_CamIn, with absolute master position and absolute slave position. Choose the StartMode that is appropriate for your machine. Best regards, Georg Seidel
Last updated: 2026-02-16

Post by gordonkeller360 on Escape character behavior for hex values in string -- what gives? CODESYS Forge talk (Post)
I have a program which sequentially places byte representations of characters from a string into an array. FUNCTION_BLOCK MoveBytesFromString VAR_IN_OUT abRxBuf: ARRAY [0..79] OF BYTE; END_VAR VAR testString : STRING := '$0A$R$L$TTesting,123...$94$86$0A'; iCount: DINT; END_VAR ---------------------------------------------------------------------------------------- // clear the buffer MEM.MemFill(ADR(abRxBuf), 80, 0); FOR iCount := 0 TO LEN(testString) - 1 DO // account for undesired null terminator of string abRxBuf[iCount] := testString[iCount]; END_FOR Escaped characters, like $T, $N, etc. work just fine, and so do their hex representation counterparts ($09, $0A, etc). However, when I put something like $94, I get a set of nonsense values... see image attached after one spin of the program. Could someone explain to me what is happening here? I'll continue to investigate...
Last updated: 2026-03-09

Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error CODESYS Forge talk (Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22

Post by hannibal on Codesys Trend - setting Y axis minimum and maximum as variables - error CODESYS Forge talk (Post)
I am experiencing an issue when trying to define the Y-axis limits in a Trend Graphic using variables. When I set the Minimum and Maximum values as variables, an error is triggered. My goal is to make the Y-axis limits dynamic so they can adjust according to the installation. Both variables are initialized as follows: gP_YMin = -100.0 gP_YMax = 100.0 However, I still get the following error: "The minimum axis value must be less than the maximum axis value" Does anyone have an idea why this is happening or how to resolve it?
Last updated: 2026-03-22

Post by poliautomacao on Absolute movement controlled by an external encoder. CODESYS Forge talk (Post)
Hello, I made this configuration, I'm moving the encoder value to SM_Driver_PosControl.in.wActPosition. When I make the absolute movement of my PosControl axis, my physical drive axis rotates perfectly, but I noticed that the movement is not followed by the encoder. That is, if I hold the encoder and keep it in position 0, the PosControl axis makes the absolute movement of 314 mm and stops, which is strange because the encoder is at 0. Theoretically, the PosControl axis should accelerate to try to compensate for the movement error. I haven't yet achieved perfect functionality.
Last updated: 2026-03-24

Post by kurt9 on ReadWriteEEprom FB question CODESYS Forge talk (Post)
I want to programmatically write the alias address to a new EtherCAT slave when I plug it into my IPC EtherCAT network. I am looking at the ReadWriteEEprom FB and see that one of the elements is "pbyData". which is the pointer to byte that is usually set to 2048 bytes. Since I am setting the alias address to the EEprom only (EEprom address 16#0012), I would assume that what I am writing is 2 bytes only. Does the pbyData have to be specified as ADR(myArray) where "myArray" is the 2 bytes of the alias address? How is the best way to set this element of the function block? Thanks in advance
Last updated: 2026-05-18

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by baotthitawat on SCADA Systems Are Becoming Easier to Integrate With Modern Applications CODESYS Forge talk (Post)
One thing I’ve been seeing recently is that more industrial systems are starting to expose realtime SCADA data through APIs instead of keeping everything isolated inside the local monitoring software. This makes integration much easier for cloud platforms, mobile dashboards, AI analytics, and enterprise applications that need realtime industrial data. Instead of exporting reports manually or building complicated middleware, APIs allow external systems to access SCADA data directly in realtime. I think this becomes especially useful for applications like wastewater treatment monitoring, where operators need better visibility into alarms, equipment status, and operational conditions across different locations. Feels like modern SCADA is slowly evolving from a standalone monitoring platform into part of a larger connected industrial ecosystem.
Last updated: 2026-05-28

Post by alex-n on Problem with keeping up the distance between two axes CODESYS Forge talk (Post)
Hello. I have a task to synchronize the movement of two axes and maintain the distance between them. First axe makes equal steps by trigger using MC_MoveRelative function. The second one is standstill and after another signal should catch up the first one from its position to a specified distance and keep it. I've tried to use MC_Phasing and mostly it works. Second axis catches up the first and starts make step with it. But in one moment this axis can crash into the first and there is no clear connection as to why this is happening. It can work correct for a day or for a week.
Last updated: 2026-06-04

Post by brouwyka on JSONByteArrayWriter problem? CODESYS Forge talk (Post)
Hey there! I am currently running into the exact same issue. The JsonData object has all inexes & parent indexes in the way I expect, everything is correctly "linked". It purely seems that the writer is incorrectly parsing said JsonData, not based on parent & child index, but on something else that breaks it and puts things at the root, instead of the specified parent index. Did you ever manage to find a solution, or another way of achieving your JSON composing? I'm currently working on Codesys V3.5 SP19 Patch 7 with IIOT Libraries SL 1.13.0.0, specifically JSON Utilities SL 1.13.0.0 (to send requests to APIs with JSON bodies using Web Client SL 1.13.0.0).
Last updated: 2026-06-08