Post by harryc on Soft Container License issue with ARM64 Linux
CODESYS Forge
talk
(Post)
Hi, We are working to provide our customers with CODESYS operation on our hardware product ( https://elprotech.com/product/el-qe-e-quantum-edge-series/ ). I'm trying to enable a CODESYS license (Soft container) on our product running ARM64 linux. This problem am having looks similar to here: https://forge.codesys.com/forge/talk/Runtime/thread/6d29b6b4de/ and here: https://forge.codesys.com/forge/talk/Runtime/thread/a2d0c63375/; but I am not running docker, and I am not re-installing a license. This is first time install. I have CODESYS Control SL running on my device, as well as CodeMeter. I purchased a license, and installed it to the CODESYS Development system, (Tools >> License Repository) then tried to install to the device (Tools >> License Manager >> o Device >> o Soft container >> Remote [0001] >> OK. This gives me the "License Manager - Overview" dialog, and the message "Licensing info not available. There is no dongle attached to the device." Below shows the running applications, installed packages, and current content of /var/opt/codesys Also attached screenshots of the Development software as I go through the steps to install the license. # # ps | grep -e "code" -e "CodeMeter" 1391 daemon /usr/sbin/CodeMeterLin 1407 root /opt/codesys/bin/codesyscontrol.bin /etc/codesyscontrol/CODESYSControl.cfg 1442 root /opt/codesysedge/bin/codesysedge.bin /etc/codesysedge/Gateway.cfg 29229 root grep -e code -e CodeMeter # dpkg -l Desired=Unknown/Install/Remove/Purge/Hold | Status=Not/Inst/Conf-files/Unpacked/halF-conf/Half-inst/trig-aWait/Trig-pend |/ Err?=(none)/Reinst-required (Status,Err: uppercase=bad) ||/ Name Version Architecture Description +++-==============-=============-============-============================================================================================== ii codemeter-lite 8.20.6539.500 arm64 WIBU CodeMeter minimal runtime ii codesyscontrol 4.14.0.0 arm64 codesyscontrol based on SDK 3.5.20.40 , from Fri Nov 29 08:35:37 CET 2024 [265], Release build ii codesysedge 4.14.0.0 arm64 codesysedge based on SDK 3.5.20.40 , from Fri Nov 29 08:34:19 CET 2024 [265], Release build # ls -la /var/opt/codesys total 208 drwxr-xr-x 6 root root 4096 Nov 7 05:31 . drwxr-xr-x 1 root root 4096 Nov 6 08:33 .. -rw-r--r-- 1 root root 23515 Nov 7 07:26 .Audit.log -rw-r--r-- 1 root root 160 Nov 7 05:31 .GroupDatabase.csv -rw-r--r-- 1 root root 160 Nov 7 04:37 .GroupDatabase.csv_ -rw-r--r-- 1 root root 20736 Nov 29 2024 .SoftContainer_CmRuntime.wbb -rw-r--r-- 1 root root 1982 Nov 29 2024 .UFC_SoftContainer_CmRuntime.WibuCmLif -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv -rw-r--r-- 1 root root 229 Nov 7 04:35 .UserDatabase.csv_ -rw-r--r-- 1 root root 11807 Nov 7 05:30 .UserMgmtRightsDB.csv drwxr-xr-x 6 root root 4096 Nov 6 08:30 .pki drwxr-xr-x 3 root root 4096 Nov 6 08:30 OPCUAServer drwxr-xr-x 7 root root 4096 Nov 6 08:30 PlcLogic -rw-r--r-- 1 root root 13 Nov 6 08:30 SysFileMap.cfg -rw-r--r-- 1 root root 2640 Nov 29 2024 bacstac.ini drwxr-xr-x 4 root root 4096 Nov 6 08:30 cert -rw-r--r-- 1 root root 94105 Nov 7 07:25 codesyscontrol.log # # uname -a Linux Remote 6.1.22 #5 SMP PREEMPT Tue Nov 18 11:35:46 AEST 2025 aarch64 GNU/Linux #
Last updated: 2025-12-04
Post by reinier-geers on wEBCLIENT Post data api
CODESYS Forge
talk
(Post)
Ive got the webclient axample. If i put https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e example to https://reqbin.com/post-online then i get data. If i do the same in Webclient example i get " not a valid graphql request. Why ? sUrl := 'https://graphql.frankenergie.nl/' Request_type_post Contenttype = 1 (json ) Postvalue := '{"query":{"query":"query MarketPrices {\n marketPrices(date:\"2025-12-25\") {\n electricityPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n gasPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n }\n}' I tranfer the postvalue from String to WSTRING
Last updated: 2025-12-25
Post by julianramirez on Visu 4.9.1 auto-logon/login
CODESYS Forge
talk
(Post)
Hello everyone, I have been trying to test the auto-login feature that is advertised on the Release Notes since Visu 4.8: *Version: 4.8.0.0 Besides some bug fixes and improvements this version contains the following new functionality: Alarmmanagement: Possibility to raise alarms programmatically Use real time clock of IEC context Automatic login for WebVisu using Chrome "Sign in automatically"* I am using a personalized login Visualization, the User Management works, however, when ticking the checkbox that keeps the credentials stored, after I reload the page I still see that the user and password details are not filled in. I tried with the default Login Visu (Blue one), and still see the same behavior - VisuUserManagement.VUM_LoginVisualization - I've tried with Chrome and Edge. Thanks for your help
Last updated: 2026-01-12
Post by baotthitawat on Why Structured SCADA Documentation Matters in Modern Industrial Systems
CODESYS Forge
talk
(Post)
Modern SCADA development is no longer limited to monitoring dashboards and PLC communication. Today’s industrial systems often require: Cloud architecture Web & mobile SCADA API integration IIoT communication Alarm management Scalable deployment workflows One challenge in many projects is that deployment knowledge is usually scattered across multiple documents, configuration guides, and troubleshooting references. As systems become more connected, engineers need a more structured learning approach to reduce deployment time and improve maintainability. The ATSCADA Training Book is an interesting example because it organizes the ecosystem into a clearer roadmap covering: SCADA architecture Driver & OPC communication Web visualization Mobile applications Cloud & IIoT systems Troubleshooting & maintenance I think structured technical documentation will become increasingly important as industrial automation systems continue evolving toward larger and more connected environments.
Last updated: 2026-05-27
Post by egerobotics on [New Hardware] EtherCAT Digital & Analog IO Board – CODESYS Compatible, All Channels Isolated
CODESYS Forge
talk
(Post)
Hi everyone, I'd like to share a new EtherCAT slave I/O board I've developed — the EtherCAT Digital & Analog IO Board by EGEROBOTICS. Key specs: 12x isolated digital outputs (24VDC) 12x isolated digital inputs (24VDC) 4x isolated 0–10V analog outputs (12-bit DAC) 4x isolated 0–10V analog inputs (12-bit ADC) All channels galvanically isolated 24VDC powered EtherCAT CoE protocol Typical use cases: Analog servo drive speed reference (0–10V) via EtherCAT Frequency inverter reference signal Proportional valve control Industrial sensor data acquisition Compatible with CODESYS SoftMotion, Beckhoff TwinCAT 2/3, LinuxCNC + EtherCAT HAL, and SOEM. Here's a quick demo video showing it running under CODESYS: 👉 https://www.youtube.com/watch?v=bUuo9reK29s ESI file, PDF manual and AutoCAD drawings available. Available on Tindie: https://www.tindie.com/products/emresensoy/ethercat-digan-io/ Happy to answer any technical questions!
Last updated: 2026-06-13
Post by timvh on CPU + EtherCAT redundancy
CODESYS Forge
talk
(Post)
It works well with two Wago 750-8210's. I helped a few customers setting this up. But it should work with any device which can control EtherCAT I/O, is real-time and has sufficient network interfaces. Two network adapters can be used to create a redundant EtherCAT network (you need 2 additional switches for this). The other network adapters can be used to interconnect the 2 PLC's (synchronization). We noticed that if you exchange variable lists that there could be some issues if you have long lists. So what we did is use a SoftPLC on a server that contains all the settings which continuously sends network packages (GVL sender) and which is received by both PLC's (network receiver). Switching over is done in milliseconds. The bus doesn't notice the change-over. EtherCAT communication works flawlessly.
Last updated: 2026-01-30
Post by konstantin on CAM Motion Recover after STO
CODESYS Forge
talk
(Post)
Hello, one of the projects I work on is about a racetrack collator with two independent belts on it - two different servo motors. Both motors share the same mechanical frame and there is a train on a belt that collects items from the input conveyor. The way the motion is performed is the following - there is a virutal master axis and both real axis are synchronised with different cam motion profiles. The problem is when an STO is triggered on any of the slave axis, the synchronization process starts from position 0 of the slaves. How can I force the slaves to retain their current position until the master passes their position? Then the slaves should catch up with the master according to the profile, the slaves should not start synchronization from 0 position. Best Regards Konstantin Kolev
Last updated: 2026-02-12
Post by jorenbeyl on library inside library
CODESYS Forge
talk
(Post)
I am currently developing a library that contains real‑time data. To handle this real‑time data, I am using additional libraries called SysTime and SysTypes Interfaces. When I compile my library on its own, no errors occur. However, when I use this library in a project and compile the project, I get an error indicating that the SysTime data type is not recognized. This happens even though the SysTime library is visible as a dependency under my library. Does anyone know how to correctly include a library within another library so that the project recognizes the sub‑library without causing compilation errors?
Last updated: 2026-04-23
Post by jroddball79 on PM556-TP-ETH — How to change IP address without overwriting the PLC program?
CODESYS Forge
talk
(Post)
We have checked open ports. SSH (22) and HTTP (80) are not reachable. The only open ports are: 502 (Modbus TCP — used for lighting control) 1200 (CODESYS runtime) 1201 (CODESYS runtime) We can connect via Automation Builder using the current IP, but we don't have the original project source — only an empty project. This is why we are afraid of doing a full download, as it would overwrite the running application. Is there any way to change the IP through the CODESYS runtime protocol on ports 1200/1201 without affecting the running program?"
Last updated: 2026-05-20
Post by gseidel on Limit Axis CNC Jerk using SMC_Polynomial_AbsMaxLocs
CODESYS Forge
talk
(Post)
Dear josepmariarams, this (internal) function has been removed with SoftMotion 4.17.0.0. We do not have public functions to compute the extrema of a polynomial. On which polynomials exactly did you call SMC_Polynomial_AbsMaxLocs? (Maybe if I understand better how you limit the jerk I can come up with an alternative.) There is no functionality to limit the jerk of individual axes in the CNC. With SMC_LimitDynamics, you can limit the velocity and acceleration of cartesian (X/Y/Z) and additional (P/Q/U/V/W/A/B/C) axes, but not the jerk. And with a quadratic ramp type you can limit the jerk on the path. Best regards, Georg
Last updated: 2026-06-10
Post by cd-tt on cannot connect ot linux runtime: device does not answer the scanrequest
CODESYS Forge
talk
(Post)
I have the following setup: Proxmox PC with a debian 13 VM running CODESYS Control Linux SL and Edge Gateway. Installation method was through the Deploy Control SL and went rather smoothly. In my Device Tab I find the gateway and when scanning my network I also find my runtime. I want to connect and get promted that I should add a user. After setting up the user I get an error saying, that the device is not responding my scanrequest. Deploy Control SL Operation saying everythings up and running. I can confirm that from the terminal on the VM with "systemctl status codesyscontrol" and "systemctl status codesysgateway". I am running out of ideas how to fix that issue. Can anybody help? Screenshots attached.
Last updated: 2026-06-11
Post by steven-schalm on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Yes, it's very tedious, especially since Codesys 4 is a custom web development... At Rex Automatisierungstechnik GmbH, we've invested a lot of time in the Python interface to enable something like CI/CD, but also to export the code and re-import it after making clean modifications. Also, the fact that a class/function block is just a single file containing all the methods, props, etc. Yes, and right now I’m building my own VS Code extension with a clean LSP (Language Server Protocol) for ST, as well as an st-validator, st-formatter, st-linter, codesysPackage.json, and codesys_modules folder... Best regards, Steven Schalm / Sharok6130
Last updated: 2026-06-11
Post by domebruce on TCP communication and TCP Streams
CODESYS Forge
talk
(Post)
Hello, I'm doing some tests with TCP communication using Reader, Writer and TCP_Process components from NBS 4.0. I'm having a really hard time finding documentation and examples on these components. I found a very simple and incomplete example here: https://forge.codesys.com/prj/codesys-example/nbs/home/Home/. The documentation is also insufficient: it only provides the names of the FBs, Methods and their parameters, but no descriptions about how to use them. Do you have any suggestions on where to find more support? More generally, why is the free online CoDeSys documentation so poor? What do you think? Thanks Domenico Canavero
Last updated: 2026-06-16
Post by fefefede on Error C0521 - unknow compiler
CODESYS Forge
talk
(Post)
Hello, i'm a new user of Codesys and student of ST program for PLC. Since today for a few new projects i have two error code C0521 and i can't solve. I also just try to update device and search library but nothign resolve. How can i fix this? Thanks
Last updated: 2023-09-02
Post by martinlithlith on CODESYS Control for Raspberry Pi SL on Raspberry Pi 4b
CODESYS Forge
talk
(Post)
hi! a quick question - is it possible to run CODESYS Control for Raspberry Pi SL license on a raspberry pi 4b? i know it says all models in the data sheet, but im not sure it the data sheet has been updated seince the MC-processors for pi. best, Martin
Last updated: 2023-09-04
Post by transmin01 on EL6751 Canopen_Manager issue
CODESYS Forge
talk
(Post)
Hi, I have a Beckhoff EL6751 EtherCAT / CANopen gateway which fails on the Canbus when the CANopen_Manager is added. Currently no devices are connected to the EL6751. If I add a device, I get the same issue. If I add a device and connect the bus, I get the same issue. Is there something I am doing wrong? Regards Trevor
Last updated: 2023-09-12
Post by fefefede on Get the numer of day
CODESYS Forge
talk
(Post)
Hello i tro to create a program to turn on or off the air condition in relationship temperature and numer of day. I can't get the number of day. I try this after installing SysTime library but this not work and have this error on debug ------ Build started: Application: Device.Sim.Device.Application ------- Typify code... Generate code... [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'SysTimeCore(TRUE)'' to type 'TIME' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'SysTimeCore' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0032: Cannot convert type 'Unknown type: 'DayOfWeek(CurrentTime)'' to type 'INT' [ERROR] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0035: Program name, function or function block instance expected instead of 'DayOfWeek' [INFORMATION] giorno_accensione_aria: PLC_PRG Device: PLC Logic: Application: C0181: Related position Build complete -- 4 errors, 0 warnings : No download possible PROGRAM PLC_PRG VAR Temperatura: UDINT; AriaCondizionata: BOOL := FALSE; CurrentDayOfWeek: INT; //Variabile Giorno CurrentTime: TIME; GiornoDellaSettimana: INT; DayOfWeek: INT; END_VAR CurrentTime := SysTimeCore(TRUE); // Ottieni l'ora corrente CurrentDayOfWeek := DayOfWeek(CurrentTime); CASE GiornoDellaSettimana OF 1: // Azioni per Lunedì 2: // Martedì se più 10° accend altrimenti spegni IF Temperatura >= 10 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 3: // Mercoledì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 4: // Giovedì se più di 40° accendi altrimenti spegni IF Temperatura >=40 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 5: // Venerdì se più di 50° accendi altrimenti spegni IF Temperatura >=50 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 6: // Sabato se più di 25° accendi altrimenti spegni IF Temperatura >=25 THEN AriaCondizionata := TRUE; ELSE AriaCondizionata := FALSE; END_IF 7: // Domenica sempre spenta AriaCondizionata := FALSE; END_CASE
Last updated: 2023-09-14
Post by snhatton on Alarm Management - latched variable represented as Text list
CODESYS Forge
talk
(Post)
Hi There, For my understanding: are you trying to display the contents of a text list in an alarm message based on the id? For example, you could maintain a text list of common alarm messages, and then display based on which message is true?
Last updated: 2023-09-18
Post by manuknecht on Detect "Cancel" Press in FileOpenSave Dialog
CODESYS Forge
talk
(Post)
Thanks for your response! It seems like the VisuElems library has updated functions to the ones you used but apparently these older ones still work, even if I couldn't find them in the library documentation and they are also not suggested automatically by Codesys (when using Ctrl + Space). However, its precisely what I was looking for and it works. Thanks!
Last updated: 2023-09-20
Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
I've post the Versions in the Attachments. It seems with htop, that there is a very high CPU Load. In the Log I can see nothing, as mentioned above I've to restart the PLC with Power off/on and the log in codesys was deleted. Or what do you mean with plclogger?
Last updated: 2023-09-23
Post by i-campbell on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED
CODESYS Forge
talk
(Post)
I can't answer why it's not resetting, but from the description of g_udiMaxReceiveBufferSize, I would guess the sum of sizes of the mqtt packets received in one cycle exceeded this value. So the answer may be to increase that parameter. https://content.helpme-codesys.com/en/libs/MQTT%20Client%20SL/Current/MQTT-Client/Common/Params/MQTTParam.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_dlg_library_parameter.html
Last updated: 2023-09-26
Post by sivakov on CoDeSys Exception EIP Adapter
CODESYS Forge
talk
(Post)
Hi, Got same problem, appeared after 4.3.1.0 update. Prabably problem is in performance. I am using virtual machine, so adding one more core and several GB to RAM still not solved, but atleast did system more stable. Try optimise your main program or set less task interval. Regards, I will be your mate in solving this mistery =)
Last updated: 2023-09-28
Post by chiali on Recipe issue.
CODESYS Forge
talk
(Post)
Hi Everyone, I'm trying to make a simple Recipe project using 'Save Recipe In File' and 'Load and Write Recipe' Execute Command buttons in Visualization but No dialog box 'Save As' appears when I click on buttons (Nothing happens). What is wrong. Please see the attached files. Best Regards, Chiali.
Last updated: 2023-10-23
Post by andrax on Mux I2C
CODESYS Forge
talk
(Post)
Hi, sorry I was not there for a long time. The TCA9548 needs terminating resistors, do you have them in? That's why I went to QWIIC, the muxboard already has them built in. If it still does not work, try it first without the muxboard. PS: Note the channel assignment. Muxboard 0 = I2C_Master 1,0,0,0,0,0,0,0 Muxboard 1 = I2C_Master 2,0,0,0,0,0,0,0 etc.
Last updated: 2023-10-29
Post by vformanek on Datasource OPC UA Client error ID:7012
CODESYS Forge
talk
(Post)
Hey, I am facing the same problem. Basically UA Expert and other programs work fine with the login credentials. But codesys can not use them properly. I can see the server login to it manually but when I download the program and run the datasource never runs... Currently I am facing the same Error ID: 7012 and cant get it running properly.
Last updated: 2023-11-21