Post by rickmotion on Opening and saving files with fileOpenSave dialog
CODESYS Forge
talk
(Post)
I have a customer that types in machine programs in a text file for machines and lets the machine execute it. In the old situation they can open and edit these files in a winform application. Now I want to move this to codesys. What I need is a simple way to open, close, save, edit the machine file in codesys visualisation. I want to use the fileOpenSave dialog. But don't understand how it works. I have the file transfer example and some other examples. But it is hard to figure out how the part with the file dialog works so that you can select a folder or file. Does someone know how that works?
Last updated: 2025-03-26
Post by rickmotion on Opening and saving files with fileOpenSave dialog
CODESYS Forge
talk
(Post)
I have a customer that types in machine programs in a text file for machines and lets the machine execute it. In the old situation they can open and edit these files in a winform application. Now I want to move this to codesys. What I need is a simple way to open, close, save, edit the machine file in codesys visualisation. I want to use the fileOpenSave dialog. But don't understand how it works. I have the file transfer example and some other examples. But it is hard to figure out how the part with the file dialog works so that you can select a folder or file. Does someone know how that works?
Last updated: 2025-03-26
Post by ahofer on ETHERCAT EK1100 und EL8601-8411
CODESYS Forge
talk
(Post)
Liebe Forumsteilnehmer, hat jemand schon die Beckhoff-Multi-Klemme EL8601-8411 am EK1100 zusammen mit dem Raspberry Pi verwendet? Ich bin gerade am Testen und habe festgestellt - dass das mit dem Einstecken der Geräte nur teilweise funktioniert. - DI/DO und AI(U) lässt sich benutzen. - Den Zähler kann ich nicht testen, weil das Gerät nicht einsteckbar ist. Ich kann es zwar einstecken, aber dann läuft der Bus nicht. - Beim Encodereingang fehlt mir vermutlich ein geeigneter Funktionsbaustein um den zu betreiben. Gibts da evtl. irgendwo eine Bibliothek? Ich benutze CODESYS V3.5.19.70, habe die neuesten Gerätedateien (XML) von Beckhoff eingespielt und für den Raspberry Pi benutze ich die Version Codesys Control for Raspberry Pi 4.14. Für Antworten bedanke ich mich schon mal herzlich VG A. Hofer
Last updated: 2025-04-04
Post by andrej on Creating, using an external Function.
CODESYS Forge
talk
(Post)
Hello all, I would like to create a simple which runs directly on Control WinV3 x64 3.5.21.0 For this purpose I created a simple dll myAdder.dll in Cpp // MyAdder.cpp // cl /LD /EHsc MyAdder.cpp /Fe:MyAdder.dll #include <windows.h> extern "C" __declspec(dllexport) int __cdecl CmpMyAdder_Add(int a, int b) { return a + b; } I added the dll in the respective folder. Furthermore I "registred" the dll in the CODESYSControl.cfg. However, when I want to use the library I get the error message: Uresolved reference: *'CMPMYADDERADD' * Can you give me a hint what step I missed or where I need to declare the dll, such that the dll resp. the reference can be resolved. Many thanks and kind regards
Last updated: 2025-04-18
Post by bruceae on Special Characters
CODESYS Forge
talk
(Post)
Hello, I am fairly new to the codesys environment. Is there a reference chart that I can look at in order to write special character in a string? The Special characters that I need to inclue inside the string are as follows; Null Bell Carriage Return I have a TCP_Write command that I am sending to an external device. In order for that device to function properly it needs to see the string with the null and bell characters as the header, followed by the desired command, terminated with the carriage return. Any reference sheet or how to write this in the actual string would be greatly appreciated.
Last updated: 2025-08-26
Post by taywinkel on Virtual Runtime CSV Utility Error
CODESYS Forge
talk
(Post)
Hello, I am having trouble figuring out the proper location for my virtual runtime to create a .CSV file. No matter the file location I set, I get error 14 (CANNOT_OPEN_DIRECTORY). I have tried multiple different file paths ('/', '/var/opt/codesysvcontrol/PlcLogic', '/var/opt/codesys/'). I understand that there is only certain places that Codesys can read/write. I am also running this virtual runtime in a Podman container. Does anyone know what the location should be? I attached the archive I was using, a project that tests CSV capability that I borrowed from someone else. Thanks!
Last updated: 2025-09-03
Post by blitz on Arcs intersection
CODESYS Forge
talk
(Post)
Does anyone have an idea how to run such a spiral on CNC smoothly without stops? SMC_SmoothPath and SMC_RoundPath don’t help. In general according to the documentation they should work on arcs but in the example only straight lines are shown and I get the impression these functions only work for straight lines. N005 G51 D15 N010 G01 X120.00 Y120.72 F100 N020 G03 X110.00 Y130.72 I-10.00 J0.00 F100 N030 G03 X100.00 Y120.72 I0.00 J-10.00 F100 N040 G03 X140.00 Y120.72 I20.00 J0.00 F100 N050 G01 X140.00 Y120.72 F100 N060 G03 X80.00 Y120.72 I-30.00 J1.67 F100 N070 G01 X80.00 Y120.72 F100 N080 G03 X160.00 Y120.72 I40.00 J-1.25 F100 N090 G01 X160.00 Y120.72 F100 N100 G03 X50.00 Y120.72 I-55.00 J-5.00 F100 N110 G01 X50.00 Y120.72 F100 N120 G03 X190.00 Y120.72 I70.00 J-0.71 F100 N125 G50 N130 M30
Last updated: 2025-09-23
Post by alexgooi on Licensing info not available.
CODESYS Forge
talk
(Post)
Thank you for the response, The empty softcontainer does not become visible unfortunately, but I think I can get that back to working. I think I'm misunderstanding something. You are pointing to the Softcontainer number and the ticket code, I thought that I needed to fill in the virtual control containers serial code is this a misunderstanding? And if this is indeed the case, how is the link between the server (softcontainer) and the Codesys control docker container made? If I have multiple Codesys docker containers running on the same docker server, how is the correct license distributed to the correct Codesys runtime container?
Last updated: 2025-10-02
Post by jmohre on External file with relative path
CODESYS Forge
talk
(Post)
I try to add a simple text file to my PLC application, so that is download everytime the application is downloaded to the target. What I did is to add an external file to the application and this works perfect as long as the external file location does not change. It looks like the external file path is stored absolute in project. But if different users work on the project they may have different locations where for their working directory. Is there an option to store the external file path relative e.g. to the project file? Or does s.o. know a different solution to add a text file to application in order to download automatically with the application? Thanks
Last updated: 2024-01-04
Post by gallusrrr on usb2can in Codeysy 3.5 Can Gateway
CODESYS Forge
talk
(Post)
Hallo Forum das ist mein erster Post bei euch also bitte seit nachsichtig :) ich habe mir den: USB zu CAN Konverter Kable for Raspberry Pi4/Pi3B+/Pi3/Pi Zero(W)/Jetson Nano/Tinker Board and Any Single Board Computer Support Windows Linux and Mac OS (USB2CAN-C) Gekauft da er in Linux arbeiten soll dachte ich man kann den so in codesys einbinden da es auf einen Rasperry Pi lauft. Erkannt wird der Adapter als Bus 001 Device 004: ID 1d50:606f OpenMoko, Inc. Geschwister Schneider CAN adapter Wie bekomme ich den in Codesys mit einen Rasperry pi eingebunden. (Im Internet habe ich nichts gefunden.) ich bedanke mich. euer Martin
Last updated: 2024-01-16
Post by ewi04 on How to upload application file to remote controller (offline) ?
CODESYS Forge
talk
(Post)
Hi, I am looking for a good way to update a decice remotely. The devices are distributed worldwide and have normally no connection to the internet. The CODESYS Automation Server can't help here. So I want to update the decices via USB stick. I have written my own code* to update the files that are created with ‘Create boot application’. But sometimes strange things happen: visu elements are present, but are not found the application is no longer registered and therefore no longer starts I have not yet found out why these errors occur. Has anyone had similar problems or found a better way? Is there perhaps a CODESYS library or something else? Many thanks! *the code deletes the directories on the device and copies the new directories from the USB stick while the system is running (goes without saying)
Last updated: 2024-02-05
Post by ewi04 on How to upload application file to remote controller (offline) ?
CODESYS Forge
talk
(Post)
Thank you very much for your time and replay! Sounds like a good idea. Unfortunately, I have no other option to run the code from the running plc. So, I can’t stop any services. If anyone has the same problem, I've gotten a little closer to understanding it: Sometimes the copied files are empty after the restart. The update code checks if there are any empty files. Before I turn off the device, everything is okay. But after starting, some files are suddenly empty and that cause the problems. I don't know why this happens.
Last updated: 2024-02-16
Post by tomast on WAGO 750-8212 nad Sinamics v20 modbus RTU speed control
CODESYS Forge
talk
(Post)
Hi Guys, I am new to this forum and i would like to ask od anyone got communication with Siemens v20 vfd working via Modbus RTU? I followed many websites and finally got the communication working but have problema with read/write registers. For example if i try to read holding register 40011 which is accel time i get noth but when i set the offset 0x0000 en length 113 i get ale the registers. I cannot get speed control working. I read someth about stw (control Word) and hsw but have some problems to understand it en get it working. It would be really nice if someone could help me with it. Thx
Last updated: 2024-03-05
Post by esave on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Hello everybody I am new into Codesys. I have a stepper driver (EM3E-556E) from Leadshine. I want to controll the stepper driver via EtherCat to a ST programm but I dont have any function block or anything that i can use. I only have the XML-File wich I loaded. With it I implemented the drive as a Ethercat slave and now I see these variables. (See picture) I dont know how to controll the stepper drive. And the manufacturer doesnt provide support for me. Can anybody help me or atleast tell me how they would do it?
Last updated: 2024-03-14
Post by mwandy on Codesys Project Protection
CODESYS Forge
talk
(Post)
I'm having trouble finding clear answers on this. I'm looking for a way to make a Codesys project password protected so that if the project is distributed it can be used to log into a controller to view and debug logic. At this same time I want to prevent the project from being saved as well as edits being downloaded to the controller. Basically I want to make a whole project view-only. What is the beat way to achieve this? I have had minor success with access rights, which solves the problem with trying to login if the project doesn't match what is in the controller. However with this solution, edits can still be made and saved, possibly corrupting the core project, preventing future logins. Any suggestions?
Last updated: 2024-03-29
Post by tecnocons on Trouble Writing Files to External Paths in CODESYS
CODESYS Forge
talk
(Post)
Hello everyone, I'm encountering an issue in CODESYS regarding writing files to external paths. Despite correctly configuring the placeholder in the CODESYSControl_User.cfg file to allow access to an external folder, CODESYS doesn't seem to write any files, and no errors are reported. The issue on the older versions was absent with no placeholders. I've checked the operating system permissions, and they seem to be in order, but the issue remains. Has anyone faced a similar situation or has any suggestions on how I might resolve this problem? Any help would be greatly appreciated. Thank you in advance for your support. I'm using raspberry PI as a logger. RPI3 Buster Codesys 32bit SL V4.11 Codesys Win64 3.5.20 [SysFile] PlaceholderFilePath.1=/home/pi/scan, $SCAN$
Last updated: 2024-04-09
Post by dkugler on build (F11) / generate code using a python script file
CODESYS Forge
talk
(Post)
thank you very much! I found the generate_code methode, but struggled with the primary and active_application. With this expample I will be able to play around. If the code generation takes a minute or more I often switch to other programs and don't notify the process is finished. So now I'll get an alert and will switch back immediately. My next little project will be, to beep different if there are errors and a seperate script to do the download incl. the user management data base without stopping at the dialogs asking for onlinechange/complete download and overwriting an existing database and as goody, play a beep/sound again.
Last updated: 2024-04-11
Post by sbrauns on Codemeter log error: API Error 200 (ENTRY NOT FOUND) occurred!
CODESYS Forge
talk
(Post)
Hi, I am using Codesyscontrol for linux 4.11 with an USB dongle with license. The log file from codemeter shows a constant error message which repeats every minute: Entry (6000437:8755) not found - Event WB0200 (ENTRY NOT FOUND), Request IP-Address local(IPV4) with UserLimit API Error 200 (ENTRY NOT FOUND) occurred! The log file from Codesyscontrol itself shows runtime licensed and I experience no other issues. But I am still concerned about the error message in the log file. Does anybody know what this is and how to fix it? thanks
Last updated: 2024-05-08
Post by k2saki on CNC Open Source Project / Can I convert my project to text-files ?
CODESYS Forge
talk
(Post)
Hi. I published My CODESYS-CNC Project to GitHub and I set it Open Source Software. Here https://github.com/k-s-saki/RPi_CODESYS_CNC My CNC Project is binary file , using FBD for IPO , so I found it is a little bit hard to work with people on GitHub. (diff / merge ) My question is 1) Is it possible to convert my project ( only POUs is also fine ) into text file ? How? 2) Would it be better to rewrite all FBD/LD into ST and copy them manually to text files? Thanks.
Last updated: 2024-05-16
Post by fpawlak on KNX SL on stock PFC200 firmware
CODESYS Forge
talk
(Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23
Post by msegon on OPC UA Client failed to connect
CODESYS Forge
talk
(Post)
Hi everyone, I would appreciate your help with a problem I've been working on for a few days but haven't been able to resolve. I'm trying to read data from Tridium Niagara 4.15 OPC UA Server, but I get the error BadCertificateInvalid. As far as I understand, you need to add a CA certificate somewhere to establish a secure connection, but I don't know where. 2025-10-27T09:06:43.247Z, 0x0000008d, 4, 0, 0, * ERROR: OpcUa_Channel_BeginConnect: Cannot create secure channel without certificates! 2025-10-27T09:06:43.247Z, 0x00001090, 4, 0, 0, * ERROR: Datasource: Error Failed (268468242) in state Connecting I tried communicating without encryption, but it doesn't find the point. Has anyone managed to establish encrypted OPC UA communication?
Last updated: 2025-10-28
Post by malte on OPC UA multiple Endpoints
CODESYS Forge
talk
(Post)
My CODESYS OPC UA server provides endpoints using both the hostname and the IP address. Connecting via the IP address works fine, but connecting via the hostname does not. The endpoint list shows both opc.tcp://<hostname>:4840 and opc.tcp://<ip>:4840. When using the hostname, the OPC UA client (UA Expert) fails to connect. Using the IP address connects without issues. Main goal is to conect via Python but opcua-asyncio seems to prefer the hostname. How can I configure CODESYS or my system so that the OPC UA connection via hostname also works properly or disable it completly? Running Codesys for PFC200 sl 4.18.0.0
Last updated: 2025-10-28
Post by pernockham on Images not shown in webvisu
CODESYS Forge
talk
(Post)
Two issues. Ive been struggling to get the user management the way I want it. I want to protect the device from unauthorized upload/download, but I do not want login requirement on webvisu. The combination that seems to work is to use "runtime device user management" while keeping the visu user management in "legacy mode"? Initially this seemed to work, but now images are not loaded when using direct access, while they are still shown if I access the webpage via Automation server. Im guessing its connected to the authorization changes? Anyone able to help out? Thanks Also, I read that legacy mode should be avoided, is it possible to use "runtime based visu user management" while keeping direct access to the webpage without login. System is a "Control for linux SL, version 4.20.0.0" Per
Last updated: 3 days ago
Post by cdutz on Problems connecting to Codesys 4.9.0.0 runtime on my Wago PFC200
CODESYS Forge
talk
(Post)
Hi all. I am currently struggling to get my Wago PFC200 running the Codesys Runtime in version 4.9.0.0 working. I am using Codesys V3.5SP19. I updated the PFC200 to the firmware version 04.01.10(23) after having tried the latest version (04.03.03(25) from Wago and not being able to start the runtime. After reading version 23 was needed, I changed to that and at least was able to have it start the codesys runtime. I also installed the "Codesys Control for PFC200 SL 4.9.0.0" plugin for Codesys to install the Codesys runtime in version 4.9.0.0 as well as update the Gateway on the device. While I seem to be able to connect to the gateway on the PLC (the dot is green) and when doing a scan, I do now find my PFC200, which is a huge improvement to before, where with firmware version 25 it just failed to start the runtime and I never found any device when doing a scan. Unfortunately I don't seem to be able to connect to the PLC in codesys. I logged in via SSH and changed the password and I can see that this password is correct as the stuff in the Codesys PFC200 tools tab only works if I use my changed password. And I used those credentials to update the installed Runtime version, which the log claimed to have worked fine. Now whenever I try to connect to the device found in the scan, I get a authentication pop-up with empy device name, device address: 000A. As User I use "root" and as password the password that I changed it to. As a response I just get "Ungültige Benutzerauthentifizierung auf dem Gerät" (Eng. probably something like "Invalid user authentication on the device". What could I be doing wrong? Admittedly I'm a bit lost here :-/ Chris
Last updated: 2023-08-26
Post by elektron785 on GPIO mit Codesys Virtual Control for Linux ARM64 SL
CODESYS Forge
talk
(Post)
Hallo zusammen, ich möchte an einem Entwicklungsboard auf dem der i.MX 8M Plus von NXP aufgesteckt ist die vier zur Verfügung gestellten GPIOs als Ausgänge verwenden. Ich habe mir dazu die Readme-Datei des GPIO-Beispiels von "C:\Program Files\CODESYS 3.5.20.40\CODESYS\CODESYS Control SL Extension Package\4.14.0.0\Examples\GPIO" angeschaut Die Übersicht der verfügbaren GPIOs sieht folgendermaßen aus - wobei ich das auf die reduziert habe, die für mich von Interesse sind: gpiochip0: GPIOs 0-31, parent: platform/30200000.gpio, 30200000.gpio: gpio-0 (SODIMM206 ) gpio-1 (SODIMM208 ) gpio-2 ( ) gpio-3 ( ) gpio-4 ( |sd-vsel ) out hi gpio-5 (SODIMM210 ) gpio-6 (SODIMM212 ) gpio-7 (SODIMM216 ) gpio-8 (SODIMM218 ) gpio-9 ( ) gpio-10 ( ) gpio-11 (SODIMM16 ) gpio-12 (SODIMM155 |regulator-usb1-vbus ) out lo gpio-13 (SODIMM157 ) gpio-14 (SODIMM185 |regulator-usb2-vbus ) out hi gpio-15 (SODIMM91 )** Füge ich nun das GPIO (1 Bit)-Gerät in meinem Codesys-Programm hinzu funktioniert der Bus solange bis ich die Richtung in den GPIO-Parametern von "not used" auf "Output" stelle (siehe Bild gpio_parameter). Dann funktioniert nach Download der Bus nicht mehr. Gibt es noch eine andere Möglichkeit das zu steuern oder muss ich noch Einstellungen tätigen? Für die Zeile mit dem echo (export/unexport) aus dem Beispiel fehlen mir trotz sudo die Zugriffsrechte. "The Kernel Linux has deprecated GPIO user space SysFS. However, the kernel config CONFIGGPIOSYSFS is still enabled on Toradex's BSP to support customers using it in their legacy applications. You can check the configuration by running zcat /proc/config.gz | grep CONFIGGPIOSYSFS. For GPIO access from userspace, the new char device API, also known as libgpiod, must be used." Dies steht in der Verwendung der GPIOs - eine Ausführung des zcat-Kommandos liefert ein =y zurück.