Post by denizerm on Deploy Control SL cant find Podman
CODESYS Forge
talk
(Post)
Hello, CODESYS seems to have problems finding the container engine. In the "Deploy Control SL" window, after connecting via ssh, it simply says: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.4.199) [WARNING] Error detecting container architecture running podman info yields normal results. My podman info output is as follows: home/Admin$ podman info host: arch: amd64 buildahVersion: 1.35.3 cgroupControllers: - cpu - memory - pids cgroupManager: systemd cgroupVersion: v2 conmon: package: Unknown path: /usr/bin/conmon version: 'conmon version 2.1.10, commit: affab49967eb62f75d2a47398344ab053326289f' cpuUtilization: idlePercent: 99.36 systemPercent: 0.3 userPercent: 0.34 cpus: 4 databaseBackend: sqlite distribution: codename: scarthgap distribution: redagv version: 1.0.0 eventLogger: journald freeLocks: 2040 hostname: secure-automation-os idMappings: gidmap: - container_id: 0 host_id: 1000 size: 1 - container_id: 1 host_id: 100000 size: 65536 uidmap: - container_id: 0 host_id: 1100 size: 1 - container_id: 1 host_id: 100000 size: 65536 kernel: 6.6.65-intel-pk-standard linkmode: dynamic logDriver: journald memFree: 6115598336 memTotal: 8086278144 networkBackend: cni networkBackendInfo: backend: cni dns: {} ociRuntime: name: crun package: Unknown path: /usr/bin/crun version: |- crun version 1.14.3.0.0.0.8-89d44-dirty commit: 89d44467e3b410b73f2065756a12789be45b855b rundir: /run/user/1100/crun spec: 1.0.0 +SYSTEMD +SELINUX +APPARMOR +CAP +SECCOMP +EBPF +YAJL os: linux pasta: executable: /usr/bin/pasta package: Unknown version: "" remoteSocket: exists: true path: /run/podman-shared/podman.sock security: apparmorEnabled: false capabilities: CAP_CHOWN,CAP_DAC_OVERRIDE,CAP_FOWNER,CAP_FSETID,CAP_KILL,CAP_NET_BIND_SERVICE,CAP_SETFCAP,CAP_SETGID,CAP_SETPCAP,CAP_SETUID,CAP_SYS_CHROOT rootless: true seccompEnabled: true seccompProfilePath: "" selinuxEnabled: false serviceIsRemote: true slirp4netns: executable: /usr/bin/slirp4netns package: Unknown version: |- slirp4netns version 1.2.0-beta.0+dev commit: unknown libslirp: 4.7.0 SLIRP_CONFIG_VERSION_MAX: 4 libseccomp: 2.5.5 swapFree: 0 swapTotal: 0 uptime: 1h 36m 10.00s (Approximately 0.04 days) variant: "" plugins: authorization: null log: - k8s-file - none - passthrough - journald network: - bridge - macvlan - ipvlan volume: - local registries: localhost:5000: Blocked: false Insecure: true Location: localhost:5000 MirrorByDigestOnly: false Mirrors: null Prefix: localhost:5000 PullFromMirror: "" search: - localhost store: configFile: /home/serviceuser/.config/containers/storage.conf containerStore: number: 2 paused: 0 running: 2 stopped: 0 graphDriverName: overlay graphOptions: {} graphRoot: /data/containerfiles graphRootAllocated: 119952025600 graphRootUsed: 13801246720 graphStatus: Backing Filesystem: extfs Native Overlay Diff: "true" Supports d_type: "true" Supports shifting: "false" Supports volatile: "true" Using metacopy: "false" imageCopyTmpDir: /var/tmp imageStore: number: 4 runRoot: /run/user/1100/containers transientStore: false volumePath: /data/containerfiles/volumes version: APIVersion: 5.0.2-dev Built: 1711987427 BuiltTime: Mon Apr 1 16:03:47 2024 GitCommit: bb81e85a430fa95d23a15b77c717fd68bf06ebf2 GoVersion: go1.22.12 Os: linux
Last updated: 2025-10-22
Post by hyplcmotion on The element of type 'VisuFbElemImage' could not be updated. Reason: Index was outside the bounds of the array.
CODESYS Forge
talk
(Post)
Hello, I’m encountering the same issue. I only receive these errors when downloading to the PLC—there are no errors during the build—after upgrading to CODESYS 3.5.21.10. Is there any known fix or recommended solution? Visualization seems running ok, no PLC log error. Visualization: Error: The element of type 'VisuFbLabel' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemImage' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemImage' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemButton' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemButton' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds. Visualization: Error: The element of type 'VisuFbElemSimple' could not be updated. Reason: Source array was not long enough. Check srcIndex and length, and the array's lower bounds.
Last updated: 2026-01-26
Post by manuknecht on Persistence Manager does not save alphabetically first value
CODESYS Forge
talk
(Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17
Post by janber0206 on Gateway doesn't come online, regarding a working internet connection
CODESYS Forge
talk
(Post)
Solved EN: The Problem is that the Codesys Edge-Gateways have a License with a runtime of an half year, as long the Gateways are online they will self renew themselfs. In my Case the RevPi was more than a year offline and so the Edge-Gateway was not working anymore. The solution: I accessed a laptop that was directly connected to the RevPi. I installed the Codesys service tool and renewed the certificate manual. DE: Das Propblem ist das die Codesys Edge-Gatways eine Lizenz haben die nur ein halbes Jahr gültig ist. Solange das Gateway eine Internet verbindung hat aktualisiert sich das Zertifikat von alleine. In meinem Fall war das Gateway aber über ein Jahr offline und hat somit nicht mehr funktioniert. Die Lösung: Ich hab auf einen Laptop von Kunden mit TeamViewer zugegriffen, der Laptop wurde mit Kabel direkt mit RevPi verbunden. Codesys Service Tool installiert und dann das Gatewayzertifikat aktualisiert.
Last updated: 2023-10-26
Post by naps on cant install runetime on 750-8202
CODESYS Forge
talk
(Post)
Hello, im trying to install the 3.5 Runtime on a a fresh image on my 750-8202. Product Description: WAGO 750-8202 PFC200 CS 2ETH RS Firmware Revision: 03.10.08(22) ~~~ df -h Filesystem Size Used Available Use% Mounted on ubi0:rootfs.1 82.5M 66.5M 11.8M 85% / devtmpfs 117.8M 16.0K 117.8M 0% /dev none 118.3M 12.0K 118.3M 0% /tmp none 118.3M 0 118.3M 0% /media none 4.0M 136.0K 3.9M 3% /var/log none 118.3M 112.0K 118.2M 0% /var/run none 118.3M 0 118.3M 0% /var/lock none 118.3M 0 118.3M 0% /var/tmp none 118.3M 0 118.3M 0% /sys/fs/cgroup tmpfs 118.3M 48.0K 118.2M 0% /run /dev/ubi0_1 58.6M 3.4M 52.2M 6% /home /dev/ubi0_1 58.6M 3.4M 52.2M 6% /settings /dev/ubi0_1 58.6M 3.4M 52.2M 6% /log ~ After installation and reboot i have still the wago webinterface. No runtime on Information Tab and the Runtime button from the configuration tab is lost. iv try it with firmware 22 and 21. Same problem. What can i do?
Last updated: 2024-09-29
Post by egau on Hard shutdown: no code on device after power on
CODESYS Forge
talk
(Post)
This explanation aligns with the issues we’re experiencing with our machines. The scenario I described is happening with one of them (let’s call it Machine A). This machine is identical to another one (Machine B), except for some custom code that facilitates communication with an external Beckhoff PLC for MES integration in the production line. Machine B has been powered on and off daily for at least three months and has never had this problem. Given that, I highly doubt the MES custom code is the cause of the code corruption. This being said, your explanation does seem plausible. However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task?
Last updated: 2024-10-03
Post by breiter on Frustration-Fueled Feedback on Project File Management and Git Integration
CODESYS Forge
talk
(Post)
Hi, supporting a text based storage format is on our roadmap, see https://www.codesys.com/the-system/releases-updates-lifecycle/release-plan-roadmap.html It will be an Add-On feature called "File Based Storage" for the professional developer edition. Structured text POUs will be stored as plain text. Other graphical languages will remain in an xml format. You will be able to switch the storage type for projects. Certain workflows will become easier this way. Nevertheless restrictions will remain because of CODESYS specific storage logic (for example how methods below function blocks are stored as file). So merging using our Git Integration Add-On remains the recommended workflow. A workflow involving Visual Studio Code as the main IDE is not supported. Simply because many topics like library management, task configuration or fieldbus configurators are not available for VS Code. A PLC project is a lot more than just some ST POUs. Best Regards
Last updated: 2024-10-16
Post by edvard-munch on How I can get "Done flag" for "Modbus Slave Channel"?
CODESYS Forge
talk
(Post)
This is from 10 years ago, I know. But I have been using (SLAVE_DEVICE.iChannelIndex = CHANNEL_NUMBER) AND (SLAVE_DEVICE.xDone) I suppose that it shows xDone for the channel that shows up in the iChannelIndex at the same cycle? It seems to be working properly for two devices that I have been using it before But now I have another device and using two write channels, for one register each. One channel works properly and returns DONE flag When another channel is triggered, I see that it shows up in iChannelIndex, but flag DONE not received, but no Error for the channel. Also, when i check the register in the device it's evident that data has been transferred. Is this could happen sometimes with CODESYS, so DONE flag not received? Or this is a problem with a given device? With this certain register
Last updated: 2024-12-19
Post by timvh on Device diagnosis ( EtherCAT IO card )
CODESYS Forge
talk
(Post)
You can get the state by just using the name of your node (same name as in device tree): VAR etcState: IoDrvEthercatDriverLib.ETC_SLAVE_STATE; END_VAR etcState := EJ1100.wState; Alternatively, you can iterate through the device tree to get the status of all (Ethercat) nodes. See here an example (no guarantee it works, just give as suggestion): PROGRAM P_IO_State VAR CONSTANT uiMAX_NR_OF_TERMINALS : UINT := 100; END_VAR VAR // general device diagnosis // can only be used when the Device - PLC Settings - Advanced settings - enable diagnosis for devices is enabled // this will add the DED library coupler: DED.INode; terminal: DED.INode; aDeviceState: ARRAY[0..uiMAX_NR_OF_TERMINALS - 1] OF DED.DEVICE_STATE; uiTerminalCount : UINT; uiIndex : UINT; // for each terminal check if it implements device diagnostics xQueryResult: BOOL; itfDevice : DED.IDevice2; xDiagAvailable: BOOL; eError: DED.ERROR; xEverythingOK: BOOL; END_VAR uiTerminalCount := 0; // start at the top of the device tree with the first EtherCAT coupler coupler := EtherCAT_Master.FirstChildNode; WHILE coupler <> 0 DO // for each coupler that is found start at the first terminal terminal := coupler.FirstChildNode; WHILE terminal <> 0 AND uiTerminalCount < uiMAX_NR_OF_TERMINALS - 1 DO // for each terminal that is found get the status through the device diagnosis interface xQueryResult := __QUERYINTERFACE(terminal, itfDevice); IF xQueryResult THEN aDeviceState[uiTerminalCount] := itfDevice.GetDeviceState(xDiagnosisInfoAvailable => xDiagAvailable, eError => eError); uiTerminalCount := uiTerminalCount + 1; END_IF terminal := terminal.NextSiblingNode; END_WHILE coupler := coupler.NextSiblingNode; END_WHILE uiIndex := 0; xEverythingOK := TRUE; WHILE uiIndex < uiTerminalCount DO IF aDeviceState[uiIndex] <> DED.DEVICE_STATE.RUNNING THEN xEverythingOK := FALSE; EXIT; END_IF uiIndex := uiIndex + 1; END_WHILE
Last updated: 2025-02-06
Post by peterkcontrols on TargetVisu started in windowed or not full screen
CODESYS Forge
talk
(Post)
Thanks for the response. I have found this file in two places, I have updated the text in both but it didnt work. Am I missing something on the Codesys side. How do you restart the soft plc, I have been stopping it and starting it. The Visu screen come up but still in full screen mode. Here are the two locations of this file: C:\Program Files\Codesys Control\GatewayPLC\AppDataFiles\CODESYSControlWinV3x64 and C:\Program Files\CODESYS 3.5.20.50\GatewayPLC\AppDataFiles\CODESYSControlWinV3x64 Here is the contents of targetvisuextern.cfg [ComponentManager] [CmpTargetVisu] ; The Window... settings can be used for displaying the targetvisualization in a window instead of fullscreen WindowType=0 WindowPositionX=0 WindowPositionY=0 WindowSizeWidth=1024 WindowSizeHeight=768 HideCursorCompletely=1 [SysWindow] ;Windows.CloseOnAltF4=0 ;Windows.CloseOnWM_CLOSE=0 [CmpLog] ;Logger.0.Name=TvExtLogger ;Logger.0.Enable=1 ;Logger.0.MaxEntries=1000 ;Logger.0.MaxFileSize=5000 ;Logger.0.MaxFiles=3 ;Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut ;Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file ;Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog
Last updated: 2025-02-26
Post by rene-h on ClientFilter used the same Client ID 2 times - Bug?
CODESYS Forge
talk
(Post)
Hello, like the topic name says, i have a problem on one Visu which i cannot reproduce on another Visu. We filter buttons with input locks and visible items with [CURRENTCLIENTID] on different WebVisu's with different ID's, and one time the itfClient used the same Client ID for 2 Clients, so the Visualization on the first ID was wrong, because that one which connected after did not have the same permissions like the first, so the first one was blocked. We read the Clients with the VisuClientIteration project: //count active clients gCli.iNumberOfClients:=gCli.iNumberOfClients+1; // if client is active write data to global struct IF gCli.iNumberOfClients > 0 THEN gCli.astClientInfo[gCli.iNumberOfClients-1].iClientID:=itfClient.ClientId ; gCli.astClientInfo[gCli.iNumberOfClients-1].stCurrentVisu:=itfClient.CurrentVisuName; gCli.astClientInfo[gCli.iNumberOfClients-1].wsUserName:=itfClient.UserName; gCli.astClientInfo[gCli.iNumberOfClients-1].sIpAddress:=itfClient.GetIPv4Address(); gCli.astClientInfo[gCli.iNumberOfClients-1].ClientType:=itfClient.ClientType; END_IF Runtime from the device: 3.5.19.20 Codesys we use: 3.5.20.10 I added a screenshot where the same ID exists 2 times. Thanks for your answers.
Last updated: 2025-05-14
Post by mavitia on Application based license problem - Modbus TCP
CODESYS Forge
talk
(Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18
Post by spiessli on Softmotion axis to CANopen Maxon IDX drive
CODESYS Forge
talk
(Post)
Thanks for the advise, indeed, this was somewhat, what my intention was. I tried around again with EDSes and DCFs, anyway. It appears that the DCFs end up in a subfolder in the attach device dialog. Astonishingly, when attaching the DCF version I get a device in the device tree, where I can add a SoftMotion axis, whereas when I attach the device not in the subfolder, then I cannot. Further astonishingly, when looking in the CANopen parameters in supported profiles, "402" is listed in the case of the DCF variant, whereas in the EDS variant "0" is shown. Comparing EDS and DCF files I cannot guess, where the difference is coming from. I cannot tell either why I have always attached the EDS variant and apparantly never the DCF variant. As I am not in the lab right now, I cannot test if the connection actually is working. Thanks again, spiessli
Last updated: 2024-01-07
Post by forest on SM Drive license error
CODESYS Forge
talk
(Post)
Hi, when it comes about license, I used INVTmatic Studio, which uses Codesys, for programming INVT plc. I bought Codesys Modbus license, it was not expensive, and then realised that INVT didn't have License Manager option (greyed out in program) which is needed for using of Codesys License. I contacted support from INVT, but developers told me that option is still not available. So depending on environment for programming Codesys, you can or not use Modbus license. Good thing about this version of Modbus TCP it works both direction. I could send commands and receive feedbacks from drive. But communication stops after 30 mins. So I used simple version of ethernet modbus which is somewhere in INVT or Condesys library (I can check tomorrow) which works only one way. I could send cmd to drive, and control it, but didn't have any feedback, like some readings back in PLC. which is bad, but at least I could start it and it didn't fail after 30 mins.
Last updated: 2024-01-10
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by tim-roelant on Profinet fault with codesys control V3 - Receive packet error
CODESYS Forge
talk
(Post)
I have set up a brandnew Beckhoff panel pc with a codesys control runtime V3. I configured it together with 2 profinet field devices: a 16in/16out IO module from Turck and an MTS linear encoder. The machine works fine untill all of a sudden the communication breaks and the profinet participants become unreachable. At that point I can still ping the device, but the profinet master does not find them anymore: When i do a scan they are not found. When i do a cold restart, the profinet master becomes active again and the devices are found again. In the log i get Ethercat packet receive error: sysethernet. I am a little confused, there is no ethercat device in the device tree. I already set the send clock and the reduction ratio to higher values, but without result. Can codesys be configured, so that the communication re-establishes without doing the cold reset? This is very annoying and is causing a lot of prodution losses. regards Tim
Last updated: 2024-02-27
Post by wmoon on Licensing info not available.
CODESYS Forge
talk
(Post)
That command can't excute on my device. I installed CODESYS into Hilscher's product using container Here is the Docker file what I used. I'm not sure if this docker file have a problem. If it have a problem, please let me know how to download the files into my device using ftp server. FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.10.0.0" ENV EDGE_VERSION "4.10.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package 'codemeter.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package 'codesyscontrol.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"]
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()"
CODESYS Forge
talk
(Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20
Post by bschraud on Code erzeugen mit kryptischer Fehlermeldung mit GVL_Io_dd05d808
CODESYS Forge
talk
(Post)
Hallo, beim Codeerzeugen bekomme ich wiederholt Fehlermeldungen, bei denen nicht mit einem Klick in das betroffene Modul gewechselt werden kann. Die Fehlermeldung tritt allerdings nach "Gerät aktualisieren" nicht mehr auf. Wenn ich das Projekt speichere, Codesys schließe, anschließend Codesys wieder starte und Code erzeugen will, tritt der Fehler wieder auf: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] PAC: C0032: Typ 'Unbekannter Typ: 'ADR(GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7)'' kann nicht in Typ 'POINTER TO IoConfigParameter' konvertiert werden [FEHLER] PAC: C0077: Unbekannter Typ: 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' [FEHLER] PAC: C0046: Bezeichner 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' nicht definiert Kompilierung abgeschlossen -- 3 Fehler, 1 Warnungen Übersetzung abgeschlossen -- 3 Fehler, 1 Warnungen : Kein Download möglich Die Recherche nach der Bedeutung von "HPS_7" oder "GVL_Io_dd05d808" verlief leider ergebnislos. Ich habe nur einen ähnlich erscheinenden Thread gefunden, der aber nicht gelöst wurde: https://forge.codesys.com/forge/talk/Engineering/thread/0666dce94f/ Ich verwende Codesys 3.5 SP20 (64bit) mit CODESYS Control for Raspberry Pi MC SL 4.11.0.0. Alle anderen Geräte sowie die Projektumgebung sind frisch aktualisiert. Kennt jemand die Bedeutung dieser Fehler bzw. wie man sie beheben kann? Vielen Dank für die Hilfe
Last updated: 2024-05-16
Post by caprez95 on Trace Restart Visuelement
CODESYS Forge
talk
(Post)
Hallo zusammen. Ich habe schon länger mit dem Problem zu kämpfen, dass ich einen Trend (Visuelement) nicht resetten (neustarten) kann. Ich habe es jetzt mit dem Beispiel hinbekommen, die Trace-Aufzeichnung über die CmpTraceMgr Bibliothek zu steuern. Aber wie bekomme ich diese Trace-Aufzeichnung in ein Visuelement? Der Code sieht wie folgt aus: // Configure trace IF xInit THEN // Create a trace packet PacketConfig.pszName := ADR('IECTraceConfiguration.Trace1'); // Name of trace PacketConfig.pszApplicationName := ADR('IECTraceConfiguration'); // Name of the application PacketConfig.pszIecTaskName := ADR('Task'); // Name of the task PacketConfig.pszComment := ADR('Demo packet'); PacketConfig.ulEveryNCycles := 1; PacketConfig.ulBufferEntries := 1000; PacketConfig.ulFlags := TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_TIMESTAMP_MS AND TRACE_PACKET_FLAGS.TRACE_PACKET_FLAGS_AUTOSTART; IF (NOT fbTraceManager.CreatePacket(PacketConfig := PacketConfig, hPacket=>hPacket1)) THEN xError := TRUE; END_IF // Create a trace record RecordConfig.pszVariable := ADR('iSignal'); // This is the name of variable to record RecordConfig.tcClass := INT_TO_UDINT(TypeClass.TYPE_INT); // Type of the recording variable RecordConfig.ulSize := SIZEOF(iSignal); // Size of the recording variable pApp := AppFindApplicationByName('IECTraceConfiguration', 0); AppGetAreaOffsetByAddress(pApp, ADR(iSignal), ADR(RecordConfig.tvaAddress.taAddress.Area.usArea), ADR(RecordConfig.tvaAddress.taAddress.Area.ulOffset)); // Get and set area offsets RecordConfig.tvaAddress.ulAddressFlags := TRACE_VAR_ADDRESS_FLAGS_IEC OR TRACE_VAR_ADDRESS_FLAGS_AREA_OFFSET; RecordConfig.ulGraphColor := 16#FF00FF00; // green RecordConfig.ulGraphType := 1; // Line with points IF (NOT fbTraceManager.AddRecord(RecordConfig := RecordConfig, hPacket := hPacket1, hRecord => hRecord1)) THEN xError := TRUE; END_IF xInit := FALSE; END_IF // Starts the recording IF xStart THEN IF (NOT fbTraceManager.StartPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStart := FALSE; END_IF // Stop the recording IF xStop THEN IF (NOT fbTraceManager.StopPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xStop := FALSE; END_IF // Reset the recording IF xReset THEN IF (NOT fbTraceManager.ResetPacket(hPacket := hPacket1)) THEN xError := TRUE; END_IF xReset := FALSE; END_IF
Last updated: 2024-06-04
Post by blitz on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
This code works well: PROGRAM PLC_PRG VAR execute : BOOL; abort : BOOL; doMDI : BOOL; manualDataInput : STRING(1024) := 'N5 G01 X0.00 Y200.00 N6 G01 X200.00 Y200.00 N7 G01 X200.00 Y0.00 N8 G01 X0.00 Y0.00'; stringStreamArray: ARRAY[0..NUMBER_OF_CHAINS-1] OF SMC_StringStream2 ; i : UDINT; readNCFromStream : SMC_ReadNCFromStream; sentencesFromStringSteam : SMC_GSentenceQueue ; interpreter : SMC_NCInterpreter; interpreterGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; roundPath : SMC_RoundPath; roundPathGeoInfoBuffer: ARRAY[1..GEO_INFO_BUFFERS_SIZE] OF SMC_GeoInfo; END_VAR VAR CONSTANT MDI_FILE_NAME : STRING := 'MDI.nc'; NUMBER_OF_CHAINS : UDINT := 15; GEO_INFO_BUFFERS_SIZE : DINT := 500; END_VAR readNCFromStream.bExecute := interpreter.bExecute := roundPath.bExecute := execute; readNCFromStream.bAbort := interpreter.bAbort := roundPath.bAbort := abort; IF doMDI THEN stringStreamArray[0].Init(MDI_FILE_NAME); stringStreamArray[0].AppendData(manualDataInput); stringStreamArray[0].SetEndOfData(); i := 0 ; WHILE i < NUMBER_OF_CHAINS DO readNCFromStream.aStream[i] := stringStreamArray[i]; i := i + 1 ; END_WHILE readNCFromStream.bExecute := TRUE; IF readNCFromStream.bBusy THEN ; END_IF END_IF readNCFromStream( fDefaultVel := 10, fDefaultAccel := 10, fDefaultDecel := 10, fDefaultVelFF := 10, fDefaultAccelFF := 10, fDefaultDecelFF := 10, sentences := sentencesFromStringSteam ); interpreter( sentences:= sentencesFromStringSteam, nSizeOutQueue:= SIZEOF(interpreterGeoInfoBuffer), pbyBufferOutQueue:= ADR(interpreterGeoInfoBuffer)); roundPath( poqDataIn := interpreter.poqDataOut, dRadius := , dAngleTol := , nSizeOutQueue := SIZEOF(roundPathGeoInfoBuffer), pbyBufferOutQueue := ADR(roundPathGeoInfoBuffer));
Last updated: 2026-01-09
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.