Post by lsislsis on Alarms Placeholder CODESYS Forge talk (Post)
Hello. When i put placeholders at "/etc/codesyscontrol/CODESYSControl.cfg" : [SysFile] FilePath.1=/etc/codesyscontrol/, 3S.dat IecFilePath.1=/proc/, cpuinfo IecFilePath.2=/proc/, iomem PlaceholderFilePath.1=/sys/devices/w1_bus_master1, $OneWire$ PlcLogicPrefix=1 PlaceholderFilePath.2=/data/persistence, $ac_persistence$ PlaceholderFilePath.2.Volatile=1 PlaceholderFilePath.2.View=1 PlaceholderFilePath.3=/data/alarms, $alarms$ PlaceholderFilePath.3.Volatile=1 PlaceholderFilePath.3.View=1 Where "Data" are my USB Flash. I take these attachment errors at run time. What i am doing wrong.
Last updated: 2024-10-15

Post by gilbert-mh on CAA net base TCP client cause PLC to crash - Kernel message : N0HZ_local_softirq_pending 80 CODESYS Forge talk (Post)
Hello all, I have been trying to implement a TCP client on a Festo PLC (CPX-E-CEC-M1) and it looks like it works well except that after some time (greatly varies between a few hours to more than 100h) my PLC crash. When I look into the log file the only thing I see is that before the crash happens a few kernel warnings : N0HZ_local_softirq_pending 80 and then the crash. I've looked into this warning and from what I could find on the net it seems that this is warning is triggered when the ethernet link is down. I've tried to correct this bug for quite some time and what I know is that : - The crash is caused by my TCP client, when I remove it from my code I see no crash - The crash happens more quickly the more the TCP client is used. - The time before the crash is not directly proportional to the number of communications or their size. But it looks like it is just more likely to happen if the client connect to the server at a higher frequency. - The precedent observation makes it seem unlikely that the crash is caused by some memory overflow because then the crash speed would be more proportional to the amount of data exchanged. SO from these observations, I believe that the crash could be caused by the PLC trying to connect to a server while there is some kind of issue with the ethernet link resulting in the PLC getting stuck in some indefinite state and making it crash. This still seems a bit unlikely to me because if the ethernet is down it simply shouldn't be able to contact the server and the communication would just fail which doesn't cause my PLC to crash. Has anyone encountered the same kind of problem (with the same kernel message) ? I am pretty sure the warning is not the direct cause of the crash but just an indicator that something is wrong with my PLC. Thanks in advance
Last updated: 2024-01-12

Post by dantheman on Connecting to SoftPLC Only Works By Turning Off Modbus Ethernet Port CODESYS Forge talk (Post)
I have an IPC with 2 ethernet ports and 1 Wi-Fi. I'm using ModbusTCP with the ethernet port named "enp2s0" connected to my remote I/O. This works fine when testing with Python and also works with CODESYS, but CODESYS is only able to scan for the Linux SoftPLC when I turn off the "enp2s0" interface. In other words, I can't get online with the IDE if I want my ModbusTCP comms to run with CODESYS. I'm using a Linux SoftPLC that has the following entry in CODESYSControl.cfg, hoping that this will allow me to connect with "enp1s0" or "wlp3s0", and leave "enp2s0" for field comms, but this seems to only make the source IP of the ModbusTCP comms to be bound to "enp2s0". That last point is the case only if I don't restart the service, but if I do restart the service after changing the config file, the source IP for the ModbusTCP comms then becomes the one for "enp1s0", which is very confusing to me: [SysSocket] Adapter.0.Name="enp2s0" Adapter.0.EnableSetIpAndMask=1 On the device list, I only have "enp2s0" given as the ethernet device that has the ModbusTCP master & slave beneath it, shown in Screenshot 1. On the IPC, I can ping the ModbusTCP client (remote I/O) from "enp2s0", and I've attached a Wireshark capture of running ModbusTCP from the CODESYS runtime as Screenshot 2, 3 & 4 (again, I can't get online when this is running, I have to turn off "enp2s0" to connect even when it's idle and I don't have an active TCP session with my Python tests). Like I explained above, the source IP is "enp1s0", even though the ethernet device on the project is "enp2s0". I was lucky to catch the red message that showed the source IP that makes sense to me (the one for "enp2s0"), but for some reason that connection was reset and I never saw that packet again. I've also tried this with Auto-reconnect both enabled & disabled, for the ModbusTCP Master device. I also have to turn off "enp1s0" and then turn it on, just so that I can have the ModbusTCP comms running from "enp2s0" (which is not intuitive in any way to me, I'd love some help understanding that phenomenon as well) in the weird manner that I've described above. I would be very appreciative if someone can help me figure out this pickle. I'd love to just connect to CODESYS through my Wi-Fi interface and leave my ethernet ports for field comms.
Last updated: 2024-08-01

Post by lepewe4ka on Sysmac Studio to Codesys CODESYS Forge talk (Post)
Could you send me an example? I would like to generate a data structure using XML files.
Last updated: 2023-09-20

Post by lepewe4ka on Sysmac Studio to Codesys CODESYS Forge talk (Post)
Could you send me an example? I would like to generate a data structure using XML files.
Last updated: 2023-09-20

Post by trycyclepower on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs CODESYS Forge talk (Post)
Thanks a lot, it worked.
Last updated: 2023-12-14

Post by ph0010421 on How to transfer data from DINT to Union(16 Bools) which I need to use in Few FBs CODESYS Forge talk (Post)
In the Struct, change the 'BOOL' to 'BIT'
Last updated: 2023-12-14

Post by eschwellinger on Data Transferring between 2 PLCs in a same PC CODESYS Forge talk (Post)
.. this will not work on the same pc
Last updated: 2024-02-06

Post by hasangenc on DI4 USB - Transfer Data CODESYS Forge talk (Post)
Hi! Did you find any solution to your problem. I'm having the same right now. Best Regards.
Last updated: 2024-02-19

Post by hasangenc on DI4 USB - Transfer Data CODESYS Forge talk (Post)
Well, Hi again. I solve the problem, if anyone having the same problem, I might help. You can reach me through this platform.
Last updated: 2024-02-22

Post by egau on Git - User identification data is lost when codesys is closed CODESYS Forge talk (Post)
It bothers me for sure.
Last updated: 2024-04-04

Post by nano on Persistent variable storage CODESYS Forge talk (Post)
use the persistence manager. with the persistence-manager, you're abΓΆe to define how, when and where you store your data
Last updated: 2024-06-16

Post by mos89p on Data source and safety PLC CODESYS Forge talk (Post)
it works only for me when i specify an IP adress in communication tab
Last updated: 2024-06-17

Post by vladimirsmall on Send data to USB CODESYS Forge talk (Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20

Post by damian177 on Problem with downloading OPC UA tags by Data Source Manager CODESYS Forge talk (Post)
After 3 hours is some progress - please find in attachment - progress1.jpg
Last updated: 2024-09-04

Post by martinlithlith on CODESYS Control for Raspberry Pi SL on Raspberry Pi 4b CODESYS Forge talk (Post)
hi! a quick question - is it possible to run CODESYS Control for Raspberry Pi SL license on a raspberry pi 4b? i know it says all models in the data sheet, but im not sure it the data sheet has been updated seince the MC-processors for pi. best, Martin
Last updated: 2023-09-04

Post by romrot on I don't know if this is where I should ask this, but I'm trying to get a Codesys OPC UA Client set up with a Kepware OPC UA Server CODESYS Forge talk (Post)
Trying to create a Data Source under Data source manager, but I'm having issues with security. I get "BadUserAcessDenied" I don't know if there is something special I need to do on the Kepware server to make this work or what.
Last updated: 2023-10-19

Post by felixal on Codesys automatic Data transfer to USB on rasberry pi CODESYS Forge talk (Post)
Hi all, I am currently working on a project where I need to save data automatically on many diffrent USB-Sticks, which are always plugged in the same USB-Port on a Rasberry PI, but I do not get how I can automatically detect the USB devices Folder Name and save a file there on Linux. Thanks!
Last updated: 2024-01-03

Post by scarter on Bit / Bool data types in function parameters CODESYS Forge talk (Post)
Any reason BIT and BOOL data types are not interchangeable? Trying to make a function which takes a BOOL IN/OUT parameter (Not allowed to use BIT) In the main logic if I make a DINT variable, and want to use each bit on different functions CODESYS will not allow it.
Last updated: 2024-01-17

Post by adarsh on CAN Tags in Writing in PLC Error. CODESYS Forge talk (Post)
Hi Folks, I have CAN Device Connected so I am able to read and write data at J1939 Manager. But unable to write the data from the PLC. Geeting the Following error while Writing from the Ladder Logic Diagram. Error:NO Valid Assignment Target How we can Rsolve this Problem
Last updated: 2024-04-02

Post by fjgonzalez on Timer On Vijeo CODESYS Forge talk (Post)
Hi. I'm trying to show in Vijeo Designer a timer countdown. But I want to display the data in hour, minutes and seconds. I tried to change the data by converting in the Machine Expert but not able to succeed. Can you help me to find a solution? Regards, FG
Last updated: 2024-05-07

Post by kuegerls on SysProcessExecuteCommand2 and CANopen Device CODESYS Forge talk (Post)
I have now conducted some tests. The problem occurs when the Python script establishes an OPCUA connection, even if I only establish the connection without reading or writing any data. Is there another way to exchange data between Python and CODESYS without having to put in a lot of effort?
Last updated: 2024-06-24

Post by tomast on Communication between PLC and HMI- sending DUT data CODESYS Forge talk (Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23

Post by tomast on Communication between PLC and HMI- sending DUT data CODESYS Forge talk (Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23

Post by tomast on Communication between PLC and HMI- sending DUT data CODESYS Forge talk (Post)
Hi everyone, I am working with project where i have DUT wihth struct. I would like to fill this data trough a form on HMI. I use NVL to communicate and i would like to know how is it possible to do this? Thanks for all your advice in advance.
Last updated: 2024-08-23