Post by winki on Error in licence activation
CODESYS Forge
talk
(Post)
Hello, Despite receiving an activation message after entering the license number, I don’t have any license installed on my gateway. I went to check in /var/opt/codesys/ and there is no License file. I searched the entire gateway for a .lic file and found no license. I’m really stuck—how can I fix this, please? When I am using the licence tools I got this picture: But nothing that have been activated. Loic,
Last updated: 2026-02-03
Post by transcend on Movesuperimposed Command Aborted Error
CODESYS Forge
talk
(Post)
Hello everyone, I am building a 3-axis packaging machine. First, I created a virtual axis and connected the knife to the virtual axis using a CAM. I also linked the conveyor system to the virtual axis with GearIn. However, I’m facing the following issue: when I use SUPERIMPOSED to change the conveyor’s motion, I get a COMMAND ABORTED error. The exact error is: SMC_ERROR.SMC_FB_WASNT_CALLED_DURING_MOTION. Why am I getting this error?
Last updated: 2026-04-11
Post by timvh on CANbus issue
CODESYS Forge
talk
(Post)
On a PC with the Control Win, this is probably related to the fact that the CAN drivers are not loaded. Go to the folder where your Control Win Configuration file is: - E.g. C:\ProgramData\CODESYS\CODESYSControlWinV3x64\E1FA7ABE - Open the CODESYSControl.cfg - Remove the semi-colon in front of the CAN driver you want to use (section ComponentManager). - Set the component ID to the next number in the list (e.g. Component.8) - Save this file and restart the Control Win.
Last updated: 2023-09-14
Post by albertisa on GPIO Konfiguration auf SK-AM64B
CODESYS Forge
talk
(Post)
Hallo, seit einigen Tagen versuche ich erfolglos eine Ansteuerung der GPIOs des SK-AM64B Entwicklungsboards (Texas Instruments) über Codesys zu bewerkstelligen. Bei dem Versuch GPIOs anzusteuern, ohne die devdesc.xml bzw. den iodriver anzupassen, wird mir von Codesys die Fehlermeldung "Bus läuft nicht" (siehe Screenshot) angezeigt. Welche Vorgehensweise wird zur Konfiguration der IO empfohlen? Ist eine Anpassung der devdesc.xml und des IOdrivers notwendig? Wie wird am besten bei der Anpassung der genannten Dateien vorgegangen? Folgende Dokumentation ist mir bekannt, hat mir aber noch nicht weitergeholfen: https://forge.codesys.com/drv/io-drivers/doc/Generic/
Last updated: 2023-09-19
Post by nano on Is there any support for I2C on Raspberry Pi?
CODESYS Forge
talk
(Post)
hello jdj this question can be answered well with a pretty good forge documentation: https://forge.codesys.com/drv/io-drivers/doc/Generic/ u r also able to create in codesys directly an iec-code by using the i2c-interface as driver using the codesys ide and st depending on the stepperdriver, used in yöur hat, its possible that an driver is already available in the device-repository. which mcp-device is used on the hat?
Last updated: 2024-03-01
Post by yannickasselin on MQTT QoS 1 & 2
CODESYS Forge
talk
(Post)
Hello, After some more tests, here is what I found out. It seems we have to increase the uiKeepAlive and tPingInterval parameters. If I increase the uiKeepAlive value to 60s and the tPingInterval to 30s, then if I disconnect the ethernet cable from Codesys and publish some messages to which Codesys subscribes to and then reconnect within 30s, I will get the messages. If I don't reconnect the cable within 30s (ping interval), the client goes in error with "ACKNOWLEDGE_TIMEOUT". When this happens, it will not automatically reconnect after reconnecting the cable. I have to disable and re-enable the client but I will not get the published messages. I need to do more tests because there are a lot of weird things happening when playing with the ping interval and the keep alive. It is not clear to me what does what. I even ended up not receiving messages anymore, even if I disabled and re-enabled the mqtt client. The client did not give any error. The only way I was able to get messages again was by modifying my client ID. After that, if I try to re-use one of the old client IDs, nothing works (publish, subscribe) and I get a TCP_INIT_ERROR and sometimes a TCP_READ_ERROR. I need more explanation/documentation about these weird behaviors. Maybe it is the way I use it, maybe it is related to the broker (I am using Mosquitto with default parameters). When using a Node-Red client, everything works perfectly. I am trying to achieve the same behavior with Codesys but it seems impossible so far.
Last updated: 2024-10-30
Post by danwoodlock on RPI Zero w - Edge gateway cant install
CODESYS Forge
talk
(Post)
Hello all, First post. I recently acquired an RPI zero W from amazon, and have been using it with Codesys v3.5 SP19 patch 2. I first got it working yesterday, and after installing the runtime on the Pi, I was prompted to install the edge gateway. Installation of the edge gateway failed because of unsupported architecture, undeterred I was able to connect to the pi and program as I wanted. The issue I've noticed is that if I do not load anything to the pi overnight, I can then no longer connect to the pi and download, although I can still ping it from my pc. I found that if I power cycle the PI, I am then able to connect again, and it works as normal. I did some googling and found instances where people recommended downloading the newest edge gateway, which brings me here. Wondering if there are any suggestions, or if this is a known issue. I actually tried installing all 3 versions of edge gateway for science, but all fail with the same message. Thanks -Dan
Last updated: 2023-09-13
Post by berto on Opening PDF in Web Browser in Target Visu HMI
CODESYS Forge
talk
(Post)
Hi everybody, I've been facing problems with the PDF visualization in Web Browser. I am trying to open a pdf file called 'sample.pdf' which I manually saved inside PlcLogic/visu folder. I am setting the web browser URL as: 'http://127.0.0.1:8080/sample.pdf' but I get 'refused connection'. I got a similar error trying to open https sites and I discovered that I can only open http websites. Opening 'http://de.wikipedia.org' everything works fine. I also tried to check using code whether the sample.pdf is present in the directory. Unfortunately, when I try to read directories of 'PlcLogic' I get file FILE_OPERATION_DENIED (I am using File.DirList). I would like to be able to open PDF files in web browser. Possibly to move new PDF files in the folder as my customer wants to display different pdf manuals on the hmi. Here you find some screenshots and my .project. I am using Codesys 3.5.19.70. Best regards, Berto
Last updated: 2024-07-11
Post by faceplant on CmpDynamicText unresolved references
CODESYS Forge
talk
(Post)
Hello! I am new to codesys so I am sorry if this is not the right place to ask this question. I am using codesys V3.5 SP20 Patch 1 + (64-bit) and a Groov EPIC PLC (GRV-EPIC-PR2). I am trying to build and deploy my application to the PLC, but when I log in I get 6 errors (codesys_error.png). It seems that the errors have to do with the CmpDynamicText system library which I have as version 3.5.20.0. I have tried to add CmpDynamicText to the ComponentManager section in the PLC's CODESYSControl.cfg file as described in this forum post and still hit the same error. I noticed that the library is grayed out in the library manager, which I think might be the issue. However I don't remember if it was grayed out before I encountered this issue. Please let me know if I can provide anymore info. Thank you!!!
Last updated: 2024-07-19
Post by ruobian on Analog Input Delay Timer
CODESYS Forge
talk
(Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20
Post by taywinkel on Virtual Keyboard Support on Login Page
CODESYS Forge
talk
(Post)
I am in the process of getting a visualization to work with the codesys keyboard. I created a custom keyboard which works fantastic for all input fields in the main visualization. I created a user management for my runtime, which gave me the standard blue login page. The codesys keyboard does not show up when trying to enter the usernam or password. I have tried every setting: changing the keyboard back to the standard codesys keyboard, and changing various settings on the visualization manager with no success. I can only use a physical keyboard connected to the device to enter the password. I did try removing the keyboard to no success either. I even tried creating my own login page so I could guarantee the keyboard showed up. This ended in disaster as I could not figure out the very complicated VisuUserManagement and VisuUserManagementDialog library, and documentation is contradictory or lacking. I imagine that an on screen keyboard is essential for many people's projects when using touchscreen panels, so I am wondering what others are doing. I would rather not use an external virtual keyboard (external to codesys) because this causes its own complications (I am working on a linux build with high securities).
Last updated: 2026-03-22
Post by struccc on Backtick identifiers
CODESYS Forge
talk
(Post)
Important: ` - Backtick - ASCII 96 ' - Apostrophe or Single Quote - ASCII 39 In the online help for some reason it renders ’ ... The only issue I don't get, why identifiers are still case-insensitive, even within `backtricks`? `mPa` and `MPa` for milli-, mega Pascal are the same identifiers, unfortunately... Is this a bug or a feature? Otherwise can do pretty nasty things with it: // A practical (?) ASCII table served as crazy strict enumeration // Just for hangover Monday mornings {attribute 'qualified_only'} {attribute 'strict'} TYPE ASCII : ( NULL := 16#00, START_OF_HEADING := 16#01, START_OF_TEXT := 16#02, END_OF_TEXT := 16#03, END_OF_TRANSMISSION := 16#04, ENQUIRY := 16#05, BELL := 16#06, ACKNOWLEDGE := 16#07, BACKSPACE := 16#08, HORIZONTAL_TAB := 16#09, LINE_FEED := 16#0A, VERTICAL_TAB := 16#0B, FORM_FEED := 16#0C, CARRIAGE_RETURN := 16#0D, SHIFT_OUT := 16#0E, SHIFT_IN := 16#0F, DATA_LINK_ESCAPE := 16#10, DEVICE_CONTROL_1 := 16#11, DEVICE_CONTROL_2 := 16#12, DEVICE_CONTROL_3 := 16#13, DEVICE_CONTROL_4 := 16#14, NEGATIVE_ACKNOWLEDGE := 16#15, SYNCHRONOUS_IDLE := 16#16, END_OF_TRANS_BLOCK := 16#17, CANCEL := 16#18, END_OF_MEDIUM := 16#19, SUBSTITUTE := 16#1A, ESCAPE := 16#1B, FILE_SEPARATOR := 16#1C, GROUP_SEPARATOR := 16#1D, RECORD_SEPARATOR := 16#1E, UNIT_SEPARATOR := 16#1F, ` ` := 16#20, `!` := 16#21, `$"` := 16#22, `#` := 16#23, `$$` := 16#24, `%` := 16#25, `&` := 16#26, `$'` := 16#27, `(` := 16#28, `)` := 16#29, `*` := 16#2A, `+` := 16#2B, `,` := 16#2C, `-` := 16#2D, `.` := 16#2E, `/` := 16#2F, `0` := 16#30, `1` := 16#31, `2` := 16#32, `3` := 16#33, `4` := 16#34, `5` := 16#35, `6` := 16#36, `7` := 16#37, `8` := 16#38, `9` := 16#39, `:` := 16#3A, `;` := 16#3B, `<` := 16#3C, `=` := 16#3D, `>` := 16#3E, `?` := 16#3F, `@` := 16#40, A := 16#41, B := 16#42, C := 16#43, D := 16#44, E := 16#45, F := 16#46, G := 16#47, H := 16#48, I := 16#49, J := 16#4A, K := 16#4B, L := 16#4C, M := 16#4D, N := 16#4E, O := 16#4F, P := 16#50, Q := 16#51, `R ` := 16#52, `S ` := 16#53, T := 16#54, U := 16#55, V := 16#56, W := 16#57, X := 16#58, Y := 16#59, Z := 16#5A, `[` := 16#5B, `\` := 16#5C, `]` := 16#5D, `^` := 16#5E, `_` := 16#5F, `agrave`:= 16#60, `a` := 16#61, `b` := 16#62, `c` := 16#63, `d` := 16#64, `e` := 16#65, `f` := 16#66, `g` := 16#67, `h` := 16#68, `i` := 16#69, `j` := 16#6A, `k` := 16#6B, `l` := 16#6C, `m` := 16#6D, `n` := 16#6E, `o` := 16#6F, `p` := 16#70, `q` := 16#71, `r` := 16#72, `s` := 16#73, `t` := 16#74, `u` := 16#75, `v` := 16#76, `w` := 16#77, `x` := 16#78, `y` := 16#79, `z` := 16#7A, `{`{} := 16#7B, `|` := 16#7C, `}` := 16#7D, `~` := 16#7E, DEL := 16#7F ) BYTE; END_TYPE
Last updated: 2025-11-05
Post by jinlee on Dynamic I/Os Mapping
CODESYS Forge
talk
(Post)
Hi there, I will give it a try. Thank you very much.
Last updated: 2023-08-19
Post by mozed on Connection to device closed
CODESYS Forge
talk
(Post)
Hello I am using an OpusA3 with version 3.5 SP17 Patch 3 as part of a project. I had no real problem before I encountered a problem that blocked me. The detection of the OpusA3 from Codesys is done correctly. The gateway is well configured and if I ping the gateway or the OpusA3 I receive the response correctly. The problem is that when I try to connect, the Opus screen freezes and a few moments later Codesys displays an error message ("connection to device closed"). I tried to change PC, to update the runtime, to change OpusA3 but the problem remains the same. I'm a little lost knowing that before it worked without problem. I went back to a previous version of the project (where it worked correctly) but the message still appears. Do you have any clues to solve the problem? Sincerely,
Last updated: 2023-08-23
Post by muhq on Profinet connection to Siemens CP343-1 Lean (IO-Device/Slave)
CODESYS Forge
talk
(Post)
Hi, I am quite new to Codesys and I try to do a Profinet connection to an Siemens PLC (315-2DP) with CP343-1 Lean Modul. I already configured the Siemens PLC, exported the GSDML. Then I added a new project in Codesys, added following moduls: - Ethernet - PN_Controller - Imported Profinet Device via GSDML importer When I start the programm everything looks fine but I always get the message "Stopped Profinet" and no data is available This is only for a small test. Therefore I start to do that on a Windows 10 with Development System. Later I will try to realize this on Raspberry. Ethernet Adapter is configured (192.168.1.1 / 24) Firewall deactivated WinPCap is installed S7-Station seems to be found ('fuadazenzitest') Can please somebody help me?
Last updated: 2023-08-26
Post by reinier-geers on Trun off webvisu
CODESYS Forge
talk
(Post)
How do i see if Webvisu is active and how to shot down if i dont want webvisu?
Last updated: 2023-08-29
Post by fefefede on Error C0521 - unknow compiler
CODESYS Forge
talk
(Post)
Hello and thanks for reply. I not have "Libray Manager" on "Update Device". I not try to open project but i open Codesys and then create a new project and when try to generate code i have the error :/ I notiche a strnge situation. I have two different software on my pc: CODESYS V3.5 SP15 Patch 4 (with this my new program not work but can open and work with some course example); CODESYS V3.5 SP19 Patch 2 (with this my custom program work) Wich version i must be choose? Why i have two different version? Thanks
Last updated: 2023-09-02
How do I list the folder names found in a PLC Directory?
CODESYS Forge
talk
(Thread)
How do I list the folder names found in a PLC Directory?
Last updated: 2015-05-07
I want to use the function of PVT to realize move
CODESYS Forge
talk
(Thread)
I want to use the function of PVT to realize move
Last updated: 2013-05-14
How does I make IO mapping possible to a new device.
CODESYS Forge
talk
(Thread)
How does I make IO mapping possible to a new device.
Last updated: 2018-11-15
Post by damian177 on Codesys V3.5 + Pixtend v1.3 + RaspberryPi
CODESYS Forge
talk
(Post)
Hi, I use Pixtend v1.3 with my RaspberryPi with Codesys V3.5 SP15 Patch1. Actually in my project I used two packages: - CODESYS Contro for Raspberry PI 3.5.15.10 - PiXtend for CODESYS 1.3.8.0 Now I would like to extend my project about the IIot Libraries SL package, I installed them. Next I added SMS_Service_SL 1.0.0.8 version library and I have problem with compile my project because I get error: [ERROR] PiXtend_DemoProject_q: Library Manager [Device: PLC Logic: Application]: Could not open library '#CAADTUtil'. (Reason: The placeholder library 'CAADTUtil' could not be resolved.) Any have idea what can I do to properly add SMS library to my project?
Last updated: 2023-09-26
Post by tanman19 on How to Use Personal Access Tokens from GitHub with Codesys Git
CODESYS Forge
talk
(Post)
I am trying to push changes to a GitHub repository. I set up the Git Remote with the correct URL and committed the change. When I push the change it asks for my GitHub credentials which I know are correct, when I type in my username and password it gives me an error: "The provided credentials seem incorrect." So I tried putting in my Person Access token and when I put that in with my username I get this error: "The server request failed and returned a HTTP error code 403: Forbidden". Does anyone know how to correctly use Personal Access Tokens from GitHub with Codesys Git? Does it have to do something with the remote url or my username? Any help or guidance would be appreciated.
Last updated: 2023-09-28
Post by aott33 on Webvisu NO load
CODESYS Forge
talk
(Post)
I will update here for others once I find out the issue.
Last updated: 2023-10-09
Post by kumareasu on Runtime System Update
CODESYS Forge
talk
(Post)
When I change the hardware Do I need to buy licence After three years ? Please refer the jpg file.
Last updated: 2023-11-26
Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C.
CODESYS Forge
talk
(Thread)
Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C.
Last updated: 2023-12-03
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.