Post by navan on codesys FileOpen operation denied from pc folder v3.5.20.10 CODESYS Forge talk (Post)
Codesys version 3.5.16.40 using file open from pc no issues. Version 3.5.20.10 have issue open file from pc any solution. thanks
Last updated: 2024-11-01

Post by timvh on File access operation denied CODESYS Forge talk (Post)
Go in Windows to this location. Right click on this file and go to properties. Is it in Read-only state? Then CODESYS cannot open in Write mode.
Last updated: 2024-11-09

Post by s1mon on Two OneWireMaster on one Raspberry PI 5 CODESYS Forge talk (Post)
Thx for the hint. It works if I add following line to the .cfg file. PlaceholderFilePath.2=/sys/devices/w1_bus_master2, $OneWire2$ Is there a documentation how to modify this config file? Will this be overwritten if I do an update of the CodesysControl Runtime?
Last updated: 2025-06-13

Post by nielscho on Saving "Input/output names" in a DCF file CODESYS Forge talk (Post)
Hello i have the same question but for Codesys 3.5. alternativley, could somebody name a Programm to create a DCF file out of an EDS? best regards
Last updated: 2025-07-02

Post by pernockham on AC Persistence - values are not read from file during start? CODESYS Forge talk (Post)
For the protocol. What also works is to do the process via ssh (using runtime on linux) sudo /etc/init.d/codesyscontrol stop modify the persistence file values sudo /etc/init.d/codesyscontrol start
Last updated: 2025-09-03

CSV_Write_read: a sample program for the CODESYS Control WinV3 writing and reading 1000 records of CSV data in a file ... CODESYS Forge talk (Thread)
CSV_Write_read: a sample program for the CODESYS Control WinV3 writing and reading 1000 records of CSV data in a file ...
Last updated: 2023-08-08

[Error when Install Codesys for Beaglebone black ver4.0.0] cannot access '/sys/bus/i2c/devices/0-0050/at24-0/nvmem': No such file or directory CODESYS Forge talk (Thread)
[Error when Install Codesys for Beaglebone black ver4.0.0] cannot access '/sys/bus/i2c/devices/0-0050/at24-0/nvmem': No such file or directory
Last updated: 2021-11-21

Post by voffi on Creating Symbol Config File from Python CODESYS Forge talk (Post)
Hello! One can create a symbol config entry in CODESYS by using create_symbol_config in a python script. Is there a way to create the xml symbol config file (!) from within a python script without going online? Thank you!
Last updated: 2023-12-12

Post by ewi04 on SysDirRead - miss 1 file in the folder list research CODESYS Forge talk (Post)
Hello, I also had this problem. I was able to solve it with the CAA File library. Here the example page: https://content.helpme-codesys.com/en/libs/CAA%20File/Current/Examples.html
Last updated: 2023-12-13

Post by gabrielmorte on PackML from Store CODESYS Forge talk (Post)
Hi, I am trying to find the PackML_Example.project file. There is only a library available in the store. Could you please help me with the example file?
Last updated: 2024-01-31

Post by gabrielmorte on PackML_example.project no longer available? CODESYS Forge talk (Post)
Hi, I am trying to find the PackML_Example.project file. There is only a library available in the store. Can someone please help me with the .project file? Thanks in advance.
Last updated: 2024-01-31

CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that? CODESYS Forge talk (Thread)
CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that?
Last updated: 2024-05-07

Post by paulg on CODESYSControl_User.cfg - link to documentation? CODESYS Forge talk (Post)
Is there somewhere in the Codesys help files that generally details what configuration options are available for this file, and what details it logs regarding the configuration file? Or is that going to differ by libraries being used? Thanks!
Last updated: 2024-06-11

Post by askic on Generate FBs from source CODESYS Forge talk (Post)
Hello, I'm coming from Siemens (TIA) world and currently learning Codesys. I'd like to know if there is an option to add external txt file with ST code for creation of a function block and then use this file as a source file from which FB will be generated? For example, in TIA, there is an option add external source file to the project structure and then use option "Generate blocks from source". This would create a FB. Does Codesys have something similar? This external source file would look like this: FUNCTION_BLOCK Scaling VAR_INPUT x, k, n : REAL; END_VAR VAR_OUTPUT y : REAL; END_VAR VAR END_VAR y := k*x+n; END_FUNCTION_BLOCK
Last updated: 2024-07-31

Post by mabac on No file found CODESYS Forge talk (Post)
CODESYS introduced many cyber security related changes over the last few years, one of them is to restrict file access. By default, file access is restricted to the PlcLogic folder and subfolders of the CODESYS control runtime of version 3.5.19.0 and newer. For Control Win this would be the folder C:\ProgramData\CODESYS\CODESYSControlWinV3x64\xxxxxxxx\PlcLogic\ To enable access to other folders, you can configure additional paths by adding them to the file CODESYSControl.cfg. For example: [SysFile] FilePath=C:/temp/test FilePath.1=C:/Users/Public You should now be able to access your file in C:\temp\test\ or in C:\Users\Public
Last updated: 2024-10-30

Post by rickmotion on Opening and saving files with fileOpenSave dialog CODESYS Forge talk (Post)
I have a customer that types in machine programs in a text file for machines and lets the machine execute it. In the old situation they can open and edit these files in a winform application. Now I want to move this to codesys. What I need is a simple way to open, close, save, edit the machine file in codesys visualisation. I want to use the fileOpenSave dialog. But don't understand how it works. I have the file transfer example and some other examples. But it is hard to figure out how the part with the file dialog works so that you can select a folder or file. Does someone know how that works?
Last updated: 2025-03-26

Post by rickmotion on Opening and saving files with fileOpenSave dialog CODESYS Forge talk (Post)
I have a customer that types in machine programs in a text file for machines and lets the machine execute it. In the old situation they can open and edit these files in a winform application. Now I want to move this to codesys. What I need is a simple way to open, close, save, edit the machine file in codesys visualisation. I want to use the fileOpenSave dialog. But don't understand how it works. I have the file transfer example and some other examples. But it is hard to figure out how the part with the file dialog works so that you can select a folder or file. Does someone know how that works?
Last updated: 2025-03-26

Post by otbeka on CAA File Handling: "Read only" error CODESYS Forge talk (Post)
Hi, On CODESYS V3.5.19.50 I am using the latest 3S File Access library (CAA File & CAA Types) to save and retrieve configuration data from the User Data section of an SD card, via file called config.txt. The application reads the file to memory once upon initialisation, and then the only other operation is overwriting the file with the updated configuration whenever the user changes the settings. An issue is ocurring, seemingly randomly, where the config.txt file, and all surrounding directories, cannot be written to by the unit, returning a READ_ONLY_CAA error upon file open. This sometimes does not clear even after power-cycling the PLC several times, yet checking the file permissions with ls -l shows normal read, write, and execute access. I am wondering if this is caused by the PLC itself or by an issue in my application. I have included my CAA File handler function block (SD_Card_Bin(FB).txt) and any associated types/calls below: TYPE ConfigData : STRUCT Config : ARRAY[0..256] OF STRING(64); NumberOfStrings : UDINT; END_STRUCT END_TYPE TYPE Buffer : STRUCT Data : ARRAY[0..SIZEOF(ConfigData)] OF BYTE; DataLength : UDINT; END_STRUCT END_TYPE A case within my MAIN PRG: mode.WriteConfigDataToFile: VisuElems.CURRENTVISU := 'Screen_Write'; IF xModeHasChanged THEN iErrorCount := 0; iRoute := 0; END_IF CASE iRoute OF 0: inBuffer := ConfigData_To_Buffer(GVL.UnitData); xConfigError := FALSE; xDataConfigured := FALSE; iRoute := 1; 1 : //Read Data from Card SD_Card_Bin.strFileName :=FileName; SD_Card_Bin.iFileOperation := 2; SD_Card_Bin(xExecute :=TRUE, WriteBuffer := inBuffer, xDone =>xDataConfigured, xError=>xConfigError, strErrorCodes=>strError); IF xDataConfigured THEN SD_Card_Bin(xExecute :=FALSE); IF xConfigError THEN iRoute := 32767; ELSE iRoute :=100; END_IF END_IF 100: // The end bCurMode := mode.DisplayProcessVariables; 32767: // Config error iErrorCount := iErrorCount + 1; IF iErrorCount > 2 THEN // Repeats 3 times, if no progress abandons and returns error bCurMode := mode.WriteError; ELSE iRoute := 0; // Try again END_IF END_CASE I'd like to rule out my application as the cause of this bug - help via comments or criticism would be greatly appreciated.
Last updated: 2025-03-19

Post by psychoengineer on Cannot Save CSV File on Windows Computer Using CODESYS and Control Win CODESYS Forge talk (Post)
I am currently working on a project using CODESYS and Control Win on a Windows computer. I've encountered an issue where I am unable to save a CSV file. I have followed the standard procedures and used the appropriate file handling functions, but the file is not being created or saved as expected. IF xStartTest THEN sFileName := '\logs.txt'; sFileName := CONCAT(gvl.g_sMainDirectory, sFileName); sFileNameCopy := '\CAAFileCopy.txt'; sFileNameCopy := CONCAT(gvl.g_sMainDirectory, sFileNameCopy); //eWriteState := FILE_OPEN_TRIGGER; xTestDone := FALSE; xError := FALSE; xStartTest := FALSE; END_IF VAR_GLOBAL g_sMainDirectory : STRING := 'C:\LogFiles'; // file path for CSV file END_VAR Despite this, the file does not appear in the specified directory, and no error messages are being generated. I've checked the directory permissions and ensured that the path is correct. Has anyone else experienced a similar issue or have any suggestions on how to resolve this? Any help would be greatly appreciated. Thank you!
Last updated: 2024-07-04

Post by pernockham on AC Persistence - values are not read from file during start? CODESYS Forge talk (Post)
Im struggling with the AC Persistence. AC persistence seems to work for any variable that is changed online and values are kept during reboot. However, if I try to edit the persistence files offline or replace the persistence files with a previously downloaded older persistence file (with modified values), the online value will not follow, as if the system did not at all read the file at boot? My testing sequence. - Edit a the value of a persistenced variable (with xSaveOnChange = True) - Save/download the associated persistence file, (and confirm the value has changed). - Edit the value online for a second time . - Stop runtime - Replace (upload) the persistence file with my previously downloaded file . - Coldstart/Warmstart/Start runtime - Whatever Im trying the value of my persistence variable will always be equal to that of my second edit as if the file is not read/considered during boot. What am I doing wrong?
Last updated: 2025-09-02

Post by mtho on JSON Utilities - JSON file written with invalid structure CODESYS Forge talk (Post)
I'm using the JSON Utilities SL library to write configurations in my program to a file. I'm generating the JSON data using the builder function block and all appears to work correctly. When I write the jsondata to file, I'm finding that some of the JSON elements are not being written in the right location in the file. Rather than writing they keys under the parent object, they get written outside the root JSON object at the end of the file. If I then try to read the file back into the program, I get an invalid_structure error. I don't get any errors when populating the JSON data or when writing the file. I attached an example of the JSON writer output. The problems begin with key P200. Each P200 should go under MBR1 through MBR3. Among the rest of the keys, they are supposed to be under different parent objects. I am using default values for wsLineBreak and encoding.
Last updated: 2024-03-06

Post by malie on 3.5.19.7 Alarme importieren in Gruppe funktioniert nicht CODESYS Forge talk (Post)
Hallo, ich hab das Problem eine Alarmliste nachdem exportieren mit oder ohne Eweiterung der Liste wird nicht wieder importiert. Unter Meldungen "Import von Alarmen" steht: "Ein Element mit dem gleichen Schlüssel wurde bereits hinzugefügt.(Zeile 0, Spalte 0)" "Import der Alarme erfolgreich abgeschlossen" Es erscheinen aber nirgends die Alarme, in vorherigen Versionen hat das immer ohne Probleme geklappt. Auch ein ändern der ID und der anderen Spalten, hinzufügen und entfernen von Spalten hat leider nicht geklappt. Selbst wenn ich eine Zeile in der Alarmgruppe erstelle die Funktioniert, diese exportiere, die Zeile lösche und wieder importiere kommen immer die gleichen Meldungen und kein Alarm wird importiert. Ich hab die Funktion schon länger nicht mehr gebraucht, deshalb kann ich nicht sagen seit welcher CoDeSys Version die Funktion nicht mehr funktioniert. Hat hier jemand eine Lösung? Gruß Max
Last updated: 2025-02-06

Post by alberto on ExportPLCopenXML is failing CODESYS Forge talk (Post)
I'm trying to export my whole project through the option ExportPLCopenXML. It seems working, but when I'm trying to import the xml I have the following error during the importation process: Object reference not set to an instance of an object. It seems a usual issue with this process that affects to the pointer to user classes inside a procedure. I receive this error for two general functions that have this pointer declarations in the VAR_INPUT section. It seems a bug into the export/import process of CodeSYS and I couldn't skip it so far. Anyone could help me? Thanks in advance.
Last updated: 2025-03-15

Post by micik on How to generate an "ENI" file CODESYS Forge talk (Post)
That really depends on this third party software you want to use. It is possible that .xml file generated with "Generate EtherCAT XML" will not be recognized as valid ENI file. Anyway, "Generate EtherCAT XML" command is not available through standard menus and needs to be added via Tools->Customize and then Add Command. You'll find it under "Devices" section. If you provide more info, we might be able to help you further.
Last updated: 2024-08-09

Post by yann2021 on Execute a .py file with Codesys CODESYS Forge talk (Post)
Hello, I have a Raspberry Pi 3 which has a printer connected to his USB port. I have a PiFace Board on the Raspberry. I have a python script file (.py) to print a logo + a text. The script is working because when I execute it from the Raspberry terminal it works. Now, when I push a button on the PiFace I would like to execute the python script file to print. How can I do that ? Many thanks for your help and advices!
Last updated: 2025-08-26