Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by salvadegianluca on SysPlcCtrl23 and C0338: The library 'cmperrors interfaces, 3.5.5.0 (system)' is supported just in 32 bit applications CODESYS Forge talk (Post)
Good afternoon to everyone; I'm stuck with this error and I don't know how to get out from it... I tried several time googling for alternative systems to control the PLC applications and resets but without success. I would like to realize the possibility to reset the CPU and to start/stop the applications as it was possible with the SysPlcCtrl23, but this library is no longer supported in 64 bit systems and it seems due to the cmperrors interfaces sub library that was included in the above said one. Someone found a work around for this issue?
Last updated: 2024-06-14

Post by tayhim on WAGO HMI Device not found CODESYS Forge talk (Post)
Hello, I'm trying to connect with a Wago TP600 HMI but without success. I'm using codysis 3.5 SP19 patch 7 (SP20 block all the time) and the official wago package is installed. However, when I scan and select my device, I get a message saying that the device doesn't match the project's device object with the possibility to update the device (as shown in the attached picture). however, after choosing to update i got a message that the device is not found. I've tried with a new empty project but the same results. do you have any ideas? Thanks.
Last updated: 2024-06-25

Post by eschwellinger on CmpCharDevice blocks gpiochip access on Raspberry Pi 5 since update from SP18 to SP21 CODESYS Forge talk (Post)
yes, this is a known issue which will be fixed with 3.5.23.0 .. soll will take some time. You need to switch back the runtime running not as dedicated user, like it was before 4.21.0.0 How to switch back you'll find here. ('Change service user' in the deploy tool) https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_linux_dedicated_user.html to sumerize both problems: 1. missing entries in CODESYSControl_Usr.cfg was the problem on Raspberry PI Runtime 2. Arm64 SL is running rootless by default since 4.21.0.0 ( Pi not by default you need to switch manually if needed due this GPIO restriction)
Last updated: 2026-07-22

Post by mawaloc on KeyPad Function in Visualization to fill a table CODESYS Forge talk (Post)
Hello Everybody, Hope you're all doing good for this new year. Since a time, I'm looking on how to use the KeyPad in vizualization to fill a textlist or something similar. my application is : In one window, I would need to be able to writte a string linked to an Numeric Values. => I can't use a std text list inside my software, as per this would be custom by customer. then from another windows I would need a "text box" to be able to select any of this String. I hope it's clear enought. thankyou for the help
Last updated: 2026-01-07

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by baotthitawat on Cloud SCADA for Industrial Energy Monitoring CODESYS Forge talk (Post)
Recently I’ve been exploring ATSCADA iEnergy Tools for SCADA-based energy monitoring systems. One thing I find interesting is how modern SCADA platforms are evolving beyond traditional machine monitoring. Many industrial systems are now using Cloud SCADA architectures for centralized energy management, remote dashboards, and operational analytics. ATSCADA iEnergy Tools supports: Real-time energy monitoring Historical data logging MySQL integration Reporting and Excel export Remote SCADA dashboards Cloud-based monitoring systems I think this type of solution is practical for factories, power monitoring applications, building management systems, and other industrial automation projects where energy optimization is becoming increasingly important. Industrial automation is clearly moving toward web-based and cloud-connected SCADA platforms, especially as more facilities focus on digital transformation and smarter energy management
Last updated: 2026-05-26

Post by dkugler on TargetVisu Freezing CODESYS Forge talk (Post)
The only weird situation i remeber with particular or complete frozen target visu was after the rtc clock was fallen or set back to the past. It looked like after running a while the alarm history database crashed during writing entries at a date lot of years in the past. After setting the rtc clock to actual date/time and deleting the alarm db every thing worked fine. I don't know, if this is/was a problem of our PLC hardware/firmware? Maybe check date/time at your system?
Last updated: 2024-09-13

Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time CODESYS Forge talk (Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27

Post by davidbo on RPI can system operation like rm in a shell have an impact on a Task cycle time CODESYS Forge talk (Post)
CODESYS Control for Raspberry Pi MC SL v4.4.0.0 CANopen_Manager 4.2.0.0 I did not call rm directly from my TASK-i2c, it was trough the attached python script. It is not always a problem happens, but sometimes a rm takes a long time. I reduced the amount of calls to logi2c.py but I don't understand why TASK-i2c sometimes can cause problems for TASK-CAN
Last updated: 2024-09-27

Post by ph0010421 on Task time too fast? CODESYS Forge talk (Post)
Hello I've made an FB which is a TCP server. It uses the excellent CAA NetServices library. If I have the FB in a task <4ms, then the RT crashes immediately at boot up. If the task >=4ms, it starts and runs perfectly. This is even if the block is not doing anything; just instantiated. Am I missing something silly? Why would a low task time cause this? 4ms is perfectly adequate, but I'm just interested why... thanks PH
Last updated: 2024-11-27

Post by lamine97 on Issue with Timer-Based Increment Function in CoDeSys Ladder Logic (LD) CODESYS Forge talk (Post)
I am trying to implement a Ladder Logic (LD) function block in CoDeSys that increments a value A by B every T time interval. My Structured Text (ST) version works perfectly in simulation, but when I implement it in LD, it does not work. The ST code: PROGRAM ADDITION VAR_INPUT A : LREAL ; B : LREAL ; T : TIME ; END_VAR VAR Timer : TON ; END_VAR Timer (IN:=TRUE, PT := T); IF Timer.Q THEN A := A + B ; Timer(IN := FALSE ) ; END_IF;
Last updated: 2025-03-25

Post by msirotkin on EtherCAT status errors CODESYS Forge talk (Post)
Didn't help. I'm just trying to understand why the errors occur. Are they from the poor driver or from the Linux network stack. That's why I wanted to know how the rxerros and lostframes are counted. Because in other places (like ethtool info) there are no any issues. And the Ethercat device works fine. And it also strange that on the second ethernet port with a different HW and driver Ethercat works better, but still time to time gets such errors.
Last updated: 2025-11-26

Post by dhumphries on Codesys Installation problem CODESYS Forge talk (Post)
Installing codesys has been the biggest point of frustration for me and is the reason I'm currently working on building a VM just for the codesys engineering software so once I get a working installation I can copy the VM to new workstations instead of fighting with the installer every time I get a workstation upgrade. The best advice I've gotten in the past is to uninstall everything and start over, this is successful 50% of the time. Also don't install the latest version it's usually less stable than an older one ironically.
Last updated: 2026-08-10

Post by bbm1995 on Security Screen - Custom Certificates for OPC UA Server? CODESYS Forge talk (Post)
Hi everyone, is it possible to use selfsigned/created certificates (eg. with X - Certificate and Key Management) as a OPC UA Server certificate in the Security Screen? As far as I know I can only upload client certificates to the PLC and move it to "Trusted", "Untrusted" and "Quarantined". Same question is on sps-forum.de
Last updated: 2023-08-23

Post by manuknecht on Specify Input Configuration "OnDialogClosed" Action to only react to certain Dialogs CODESYS Forge talk (Post)
Thanks for your responses. The close listener sounds like an interesting approach, will have to see what I can do with it. I actually solved it as suggested by sturmghost by setting an enum variable to a certain state as soon as I open a dialog. This way I always know which dialog was opened last.
Last updated: 2023-10-02

Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Just a stab in the dark, but you might want to check the Dynamic Limits (accel, decel, velocity, jerk) in the Codesys SoftMotion device configuration, as well as checking similar limits on your servo drive? Are you seeing any errors, or does the MC_SetPosition FB get marked as complete?
Last updated: 2025-01-09

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

Post by secundino on License CODESYS Forge talk (Post)
Good morning, I need to activate a CODESYS license on your website, as the computer where it was originally installed has been formatted. I have already sent two emails to store-support@codesys.com, but I have not received a response yet. Could you please assist me with this issue as soon as possible?
Last updated: 2025-02-20

Post by tvm on Cannot pass array of constant size to a function as a reference CODESYS Forge talk (Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09

Post by reinier-geers on Swap Output in frame CODESYS Forge talk (Post)
How can i swap an output in a frame ? Ive got a frame of a mixer. use this twise. I want to turn these on and of. i can Get in the frame as dwAdr_Mixer : DWORD; . as Var_IN_OUT. Then Adress as Adr(Output ) But in the frame i cant swap dwAdr_Mixer^ :-= not dwAdr_Mixer^ ;
Last updated: 2024-03-11

Post by gseidel on CODESYS SoftMotion Generic DSP402 on WAGO PFC200 + Festo CMMT-AS: MC_Power stays Busy, Controlword remains 0 CODESYS Forge talk (Post)
Hi gilad, the missing license does not prevent the axis from being enabled. As far as I know, Festo distributes a CODESYS SoftMotion driver for the CMMT drives together with their software. I would contact Festo and ask for the driver. Best regards, Georg
Last updated: 2026-06-25

Post by full0pullpolen on Device User Logon CODESYS Forge talk (Post)
The following guide describes how you can adapt the user management for the first time in a project. It deals with the definition of a user and a group to which he belongs. Requirement: the project for which the user management is to be set up is opened. There is no adapted user configuration yet. Select Project Settings ‣ Users and Groups and then the Users tab. The user Owner is already created by default. Click on Add. ⇒ The dialog box Add User appears. Enter a login name, for example ‘Dev1’, and a password. Leave the option Activated activated. Click on OK. ⇒ On creating a group for the first time, CODESYS now requests you to authenticate yourself to perform this action. In this case, enter ‘Owner’ as the current user. Do not enter a password, just click on OK. The user Dev1 appears in the list and is automatically a member of the group 'Everyone'. Change to the tab Groups, in order to add the user to a new group. ⇒ The groups Everyone and Owner have already been created. Click on Add in order to open the dialog box Add Group. Specify at least one name for the new group, for example ‘Developers’. Activate the checkbox next to the entry User ‘Dev1’ in the field Members. Click on OK. ⇒ The group Developers now appears with has user member 'Dev1'. Switch to the Users tab. ⇒ The user Dev1 now appears as a member of the groups ‘Everyone’ and ‘Developers’.
Last updated: 2024-01-24