Search talk: how to use interface set property

 
<< < 1 .. 230 231 232 233 > >> (Page 232 of 233)

Post by ton on String nach erlaubten/unerlaubten Zeichen durchsuchen CODESYS Forge talk (Post)
Hi Timo, FUNCTION Sonderzeichen_Check : bool VAR_INPUT sInputString : STRING; // Zu prüfender String END_VAR VAR i: INT; iAsc: INT; END_VAR Sonderzeichen_Check:= TRUE; FOR i:= 0 TO len(sInputString) - 1 DO iAscii:= sInputString[i]; //Get ASCII value //Check value between 48('0') and 65('9') or between 65('A') and 90('Z') or between 97('a') and 122('z') or IF iAscii >= 48 AND iAscii <= 57 OR iAscii >= 65 AND iAscii <= 90 OR iAscii >= 97 AND iAscii <= 122 THEN //iAscii valit ELSE Sonderzeichen_Check:= FALSE; END_IF END_FOR Diese FUNCTION anrufen: VAR xTest1: BOOL; xTest2: BOOL; sCheck: STRING; END_VAR xTest1:= Sonderzeichen_Check(sInputString:= 'abcuharoahse89347KEWDL'); //=TRUE xTest2:= Sonderzeichen_Check(sInputString:= 'abcuharoahse89347KEWDL?'); //=FALSE IF Sonderzeichen_Check(sInputString:= 'CheckThisSting,') THEN sCheck:= 'OK'; ELSE sCheck:= 'NOT OK'; END_IF
Last updated: 2025-01-20

Post by eaglealex on Length of string and Array of bytes CODESYS Forge talk (Post)
Hello! I have tried read a file to the string variable. But I faced a problem - there is about 2800 bytes of information in file, but string have a limit 2393 bytes. I made two variables with same address (for automatic convertion) - string[3000] and array of bytes[1..3000]. And I noticed that array of bytes contains all information from file, but string shows only first 2393 bytes. So I have lost information. Is there really such a limitation? Or I have an error in my program and Codesys 2.3 have no limit for such kind of conversation between string and array of bytes? Thank you very much!
Last updated: 2025-04-01

Post by aeem on CODESYS Installer does't open CODESYS Forge talk (Post)
Just downloaded stand alone setup, deleted old installer and installed new. Looked up at the installation log - MSI (c) (48:E0) [19:33:49:483]: Windows Installer installed the product. Product Name: CODESYS Installer. Product Version: 2.4.0.3545. Product Language: 1033. Manufacturer: CODESYS GmbH. Installation success or error status: 0. Installer still not running EDIT: It's working. Somehow my Windows Event Log service was disabled. I restarted the service and everything is working fine right now. Click the Start Menu or (Windows key + R) Type services.msc into the search field (Enter) Open the Services app Find a service you want to disable/enable (Windows Event Log), and double click Click Start
Last updated: 2025-04-01

Post by jampid on Struct Literal CODESYS Forge talk (Post)
Bonjour Davidmic, Il n'est pas possible d'associer une méthode à une fonction. Cela est possible sur les Blocs fonctions. En utilisant ta DUT MyStruct, je créé une fonction avec en entrée un tableau de structure :** FUNCTION F_F3 : REAL VAR_IN_OUT // bien définir un type IN_OUT IN_ptrINT: ARRAY[*] OF MyStruct; // la taille sera définie ultérieurement/ END_VAR VAR _di: DINT; // Index de parcours du tableau pour l'écriture dans les cases ENDVAR ============== //Programme F_F3: FOR _di := LOWER_BOUND(IN_ptrINT,1) TO UPPER_BOUND(IN_ptrINT,1) DO IN_ptrINT[_di].som:=IN_ptrINT[_di].a + IN_ptrINT[_di].b; END_FOR J'utilise ensuite cette fonction dans un POU Programme : PROGRAM Test_F_Fx VAR _aiTAB9:ARRAY[0..3] OF MyStruct := [(a := 1, b := 1.2), (a := 2, b := 2.2), (a := 3, b := 3.3), (a := 4, b := 4.4)]; END_VAR ** ==========** F_F3(IN_ptrINT:=_aiTAB9 ); Voilà l'idée pour avancer. Une autre idée, est d'utiliser les pointeurs ou les références. Bon développement!
Last updated: 2025-04-07

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by preimesbergert on Raspberry Pi 4 B HW 1.5 Codesys control 4.10.0 stopps after a few seconds CODESYS Forge talk (Post)
Wanted to play a bit with a raspberry Pi 4 Model B HW 1.5 and Codesys. Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager) and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant, always is the runtime stopped after about 30sec with the nice message: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-7, 0x00000BB8, 0xFFFFFFFB) Whats wrong with it?!?!? I read a lot about the issue in topics from 2020-2021 but it always was stated with new Codesys control version issue will be fixed (4.4 for example) but still it is there.
Last updated: 2023-12-21

Post by karol-abktech on Raspberry and problem with runtime CODESYS Forge talk (Post)
Hi, My problem is with raspberry pi 4 with 2 GB ram,. Install codesys is correct but runtime works only few seconds or I can connect with device few seconds. I can ping raspberry and in system info I can see " !!!! Warning: no runtime license - running in demo mode(~2 hours)" but it is 2 minutes after runtime. When I press Start runtime I have another few seconds when I can connect to raspberry. After this time I couldn't find device. Of course, reapet start runtime works every time on few second. Raspberry is new and works with fresh install raspberry os 32 bit. Where should I start looking for solve of my problem ?
Last updated: 2024-02-14

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21

Post by lzml on Safety CODESYS Forge talk (Post)
I have a problem with a project that uses EtherCAT Safety. The project is developed with CODESYS version 3.5.19.20, runtime 3.5.18.30, safety CPU EL6900 4.3.1.0, TCEL6900FBS 3.5.1.10, IODrvEL6900 4.3.1.0, IODrvEtherCAT 4.1.0.0. The safety project works correctly, but when I download the PLC project for modifications, the ESM objects are no longer aligned with the states inside the safety program. Specifically, inside the safety program, they are seen as true, while outside the safety program, the state is reported as false, but not for all ESMs, only some. I have already tried to completely redo the safety from scratch, but nothing has changed. Any solutions? Thanks
Last updated: 2024-05-24

Post by paro on Modbus Client Request Not Processed CODESYS Forge talk (Post)
Hi, works in my case if I increase the timeout! to_udint(t#100ms) -> 100 -> 100us.. FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; uistart: UINT := 100; udiTimeout1: UDINT; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=1000000); // 1sec END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=uistart, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0]));
Last updated: 2024-05-30

Post by zer0g on Modbus Client Request Not Processed CODESYS Forge talk (Post)
I'm using the code bellow which is based on the Codesys example: FUNCTION_BLOCK MODBUS_master_example_ST VAR initDone : BOOL := FALSE; aIPAddress : ARRAY [0..3] OF BYTE := [127,0,0,1]; clientTcp: ModbusFB.ClientTcp; // buffer to read input registers aDataInputRegisters : ARRAY[0..9] OF UINT; // some client requests clientRequestReadInputRegisters: ModbusFB.ClientRequestReadInputRegisters; xExecute: BOOL; END_VAR IF NOT initDone THEN initDone := TRUE; // configure clientTcp clientTcp(aIPaddr:=aIPAddress, uiPort:=502, udiLogOptions := ModbusFB.LoggingOptions.All); // configure clientRequestReadInputRegisters clientRequestReadInputRegisters(rClient:=clientTcp, uiUnitId:=1, udiTimeout:=TO_UDINT(T#1000MS)); END_IF // call the client FB's clientTcp(); clientRequestReadInputRegisters(rClient:=clientTcp,xExecute := xExecute AND NOT clientRequestReadInputRegisters.xBusy ,uiStartItem:=2, uiQuantity:=3, pData:=ADR(aDataInputRegisters[0])); As you can see the clientTCP is called cyclically with the same result.
Last updated: 2024-05-30

Post by timothyzalusky on Strange Behavior on Raspberry Pi CODESYS Forge talk (Post)
Hello, I am seeing some weird runtime behavior related to the EQ function on a rapsberry pi based system. I have attached a screenshot showing the strange latching I am seeing on the EQ function, and I have not seen this behavior before. I tried freshly restarting the runtime and it has this same behavior. Anyone seen this? I am on 3.5.20 with the latest runtime installed. Basically, as soon as it hits one of those EQ's in the program, it latches effectively locking the output on. Any input from the Codesys team would be appreciated as well as anyone that might know what I am seeing.
Last updated: 2024-06-18

Post by imdatatas on Error: C0138: No matching 'FB_Init' method found for instantiation of VisuClientObjectMgr CODESYS Forge talk (Post)
Unfortunately, the "C0138: No matching 'FB_Init" method found" error is a nightmare for CODESYS V3.5 SP21. I'm not sure if anything has been done about this or if anything will be fixed. I've encountered the same issue many times, and it was only resolved by completely uninstalling SP21, deleting all related files and folders from my computer, and then installing SP19. So, I've given up on using SP21 and switched back to SP19patch7. Here are some previous posts regarding the "C0138: No matching 'FB_Init" on SP21 of Codesys. https://forge.codesys.com/forge/talk/Visualization/thread/0763d6ca8e/ https://forge.codesys.com/forge/talk/Motion/thread/9074005bf4/
Last updated: 2025-11-28

Post by rajatdas2005 on Codesys Virtual control SL CODESYS Forge talk (Post)
Dear All, This is regarding Codesys Virtual control SL demo version. I am facing one issue. First I will describe the steps what I have followed till now. 1. In a PC I have Windows OS. Here Codesys IDE is installed, and also using the installer option of IDE I have also installed Codesys Virtual control SL. 2. A edge-gateway is also running in the same windows PC as local host. 3. Next I have a seperate PC with Ubuntu OS with docker installed. This machine is in the same network. 4. Now I have created a project in Windows machine using device "Codesys Virtual control SL". 5. In the Ubuntu machine I am running the Codesys Virtual control SL as docker and it is using the ubuntu machine network only. 6. Next using the localhost edge-gateway when I am searching the virtual control SL docker it is able to detect it. (screenshot attached) 7. But after creating the creadentials it is telling No Device is responding. 8. I have also checked the wireshark logs and able to see that in destination port 11740 data is coming. 9. From windows PC telnet ip 11740 is also working. 10. Ping is also working ===========================================LOGS ========================= sudo ss -tlnp | grep -E "(443|1217|4840|8080|11740)" LISTEN 0 10 10.135.114.142:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=21)) LISTEN 0 10 172.18.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=24)) LISTEN 0 10 172.17.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=23)) LISTEN 0 10 127.0.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=26)) LISTEN 0 10 192.168.122.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=22)) LISTEN 0 5 0.0.0.0:11740 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=20)) LISTEN 0 128 0.0.0.0:8080 0.0.0.0: users:(("python3",pid=1280,fd=4)) LISTEN 0 10 172.19.0.1:4840 0.0.0.0: users:(("codesyscontrol.",pid=41864,fd=25))
Last updated: 2025-08-06

Post by superjojo2002 on Licensing info not available. CODESYS Forge talk (Post)
I updated the docker container runtime to version 4.11.0.0. and build the container with this "Dockerfile" FROM arm64v8/debian:11.6 RUN apt-get update RUN apt-get install -y wget sudo unzip libusb-1.0-0-dev procps ENV CDS_VERSION "4.11.0.0" ENV EDGE_VERSION "4.11.0.0" ENV URL "https://store-archive.codesys.com/ftp_download/3S/LinuxARM64/2302000039/$CDS_VERSION/CODESYS%20Control%20for%20Linux%20ARM64%20SL%20$CDS_VERSION.package" ENV EDGE_URL "https://store-archive.codesys.com/ftp_download/3S/EdgeGatewayLinux/000120/$EDGE_VERSION/CODESYS%20Edge%20Gateway%20for%20Linux%20$EDGE_VERSION.package" RUN wget --output-document=/tmp/codesys.package $URL && \ unzip -p /tmp/codesys.package '*codemeter*.deb' > /tmp/codemeter.deb && dpkg -i /tmp/codemeter.deb && \ unzip -p /tmp/codesys.package '*codesyscontrol*.deb' > /tmp/codesys.deb && dpkg -i /tmp/codesys.deb RUN wget --output-document=/tmp/edge.package $EDGE_URL && \ unzip -p /tmp/edge.package '*arm64.deb' > /tmp/edge.deb && dpkg -i /tmp/edge.deb EXPOSE 11740 1217 11743 ENTRYPOINT ["/bin/sh", "-c" , "/etc/init.d/codemeter start && /etc/init.d/codemeter-webadmin start && /etc/init.d/codesyscontrol start && /etc/init.d/codesysedge start && tail -f /dev/null"] Now cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 8.00 of 2023-Nov-28 (Build 5967) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. But still CODESYS development system reports that it needs a dongle and when I click install that "value cannot be null. Parameter name: containerToLicenses" It seems that Codemeter is forced to look for a dongle instead of a CMsoftcontainer. Can you confirm that CODESYS licensing works also when CODESYS is installed in a Docker container?
Last updated: 2024-03-21

Post by denizerm on Deploy Control SL cant find Podman CODESYS Forge talk (Post)
Hello, CODESYS seems to have problems finding the container engine. In the "Deploy Control SL" window, after connecting via ssh, it simply says: [INFORMATION] Connected successfully! [INFORMATION] Successfully connected to target (192.168.4.199) [WARNING] Error detecting container architecture running podman info yields normal results. My podman info output is as follows: home/Admin$ podman info host: arch: amd64 buildahVersion: 1.35.3 cgroupControllers: - cpu - memory - pids cgroupManager: systemd cgroupVersion: v2 conmon: package: Unknown path: /usr/bin/conmon version: 'conmon version 2.1.10, commit: affab49967eb62f75d2a47398344ab053326289f' cpuUtilization: idlePercent: 99.36 systemPercent: 0.3 userPercent: 0.34 cpus: 4 databaseBackend: sqlite distribution: codename: scarthgap distribution: redagv version: 1.0.0 eventLogger: journald freeLocks: 2040 hostname: secure-automation-os idMappings: gidmap: - container_id: 0 host_id: 1000 size: 1 - container_id: 1 host_id: 100000 size: 65536 uidmap: - container_id: 0 host_id: 1100 size: 1 - container_id: 1 host_id: 100000 size: 65536 kernel: 6.6.65-intel-pk-standard linkmode: dynamic logDriver: journald memFree: 6115598336 memTotal: 8086278144 networkBackend: cni networkBackendInfo: backend: cni dns: {} ociRuntime: name: crun package: Unknown path: /usr/bin/crun version: |- crun version 1.14.3.0.0.0.8-89d44-dirty commit: 89d44467e3b410b73f2065756a12789be45b855b rundir: /run/user/1100/crun spec: 1.0.0 +SYSTEMD +SELINUX +APPARMOR +CAP +SECCOMP +EBPF +YAJL os: linux pasta: executable: /usr/bin/pasta package: Unknown version: "" remoteSocket: exists: true path: /run/podman-shared/podman.sock security: apparmorEnabled: false capabilities: CAP_CHOWN,CAP_DAC_OVERRIDE,CAP_FOWNER,CAP_FSETID,CAP_KILL,CAP_NET_BIND_SERVICE,CAP_SETFCAP,CAP_SETGID,CAP_SETPCAP,CAP_SETUID,CAP_SYS_CHROOT rootless: true seccompEnabled: true seccompProfilePath: "" selinuxEnabled: false serviceIsRemote: true slirp4netns: executable: /usr/bin/slirp4netns package: Unknown version: |- slirp4netns version 1.2.0-beta.0+dev commit: unknown libslirp: 4.7.0 SLIRP_CONFIG_VERSION_MAX: 4 libseccomp: 2.5.5 swapFree: 0 swapTotal: 0 uptime: 1h 36m 10.00s (Approximately 0.04 days) variant: "" plugins: authorization: null log: - k8s-file - none - passthrough - journald network: - bridge - macvlan - ipvlan volume: - local registries: localhost:5000: Blocked: false Insecure: true Location: localhost:5000 MirrorByDigestOnly: false Mirrors: null Prefix: localhost:5000 PullFromMirror: "" search: - localhost store: configFile: /home/serviceuser/.config/containers/storage.conf containerStore: number: 2 paused: 0 running: 2 stopped: 0 graphDriverName: overlay graphOptions: {} graphRoot: /data/containerfiles graphRootAllocated: 119952025600 graphRootUsed: 13801246720 graphStatus: Backing Filesystem: extfs Native Overlay Diff: "true" Supports d_type: "true" Supports shifting: "false" Supports volatile: "true" Using metacopy: "false" imageCopyTmpDir: /var/tmp imageStore: number: 4 runRoot: /run/user/1100/containers transientStore: false volumePath: /data/containerfiles/volumes version: APIVersion: 5.0.2-dev Built: 1711987427 BuiltTime: Mon Apr 1 16:03:47 2024 GitCommit: bb81e85a430fa95d23a15b77c717fd68bf06ebf2 GoVersion: go1.22.12 Os: linux
Last updated: 2025-10-22

Post by manuknecht on Persistence Manager does not save alphabetically first value CODESYS Forge talk (Post)
After some more digging I realized that I get an error on the PLC Logger saying PersistenceChannel: 150 (invalid type in data: SimpleLibrary). I suppose the issue could be found in the ConfigData, which is automatically generated and which looks like this: 1 9##83 SimpleLibrary#GVL.aMoreZeros.[1]#0#64512#15#0 <[2]#0#64520#15#0 <[3]#0#64528#15#0 <[4]#0#64536#15#0 <#0#64544#15#0 <[6]#0#64552#15#0 <<lrVar#0#64560#15#0 <strVar#0#64428#16#80 <uiDummy#0#64370#11#0 Perhaps the fact that the variable is stored within a library confused the compiler? I tried changing the PersistenceChannel parameters to xCompressTags := FALSE which changed the entry in the data file from _xCompressTags BOOL:TRUE _xCompressTags BOOL:FALSE but the actual content of the data file and also the config data did not change.
Last updated: 2023-10-17

Post by janber0206 on Gateway doesn't come online, regarding a working internet connection CODESYS Forge talk (Post)
Solved EN: The Problem is that the Codesys Edge-Gateways have a License with a runtime of an half year, as long the Gateways are online they will self renew themselfs. In my Case the RevPi was more than a year offline and so the Edge-Gateway was not working anymore. The solution: I accessed a laptop that was directly connected to the RevPi. I installed the Codesys service tool and renewed the certificate manual. DE: Das Propblem ist das die Codesys Edge-Gatways eine Lizenz haben die nur ein halbes Jahr gültig ist. Solange das Gateway eine Internet verbindung hat aktualisiert sich das Zertifikat von alleine. In meinem Fall war das Gateway aber über ein Jahr offline und hat somit nicht mehr funktioniert. Die Lösung: Ich hab auf einen Laptop von Kunden mit TeamViewer zugegriffen, der Laptop wurde mit Kabel direkt mit RevPi verbunden. Codesys Service Tool installiert und dann das Gatewayzertifikat aktualisiert.
Last updated: 2023-10-26

Post by egau on Hard shutdown: no code on device after power on CODESYS Forge talk (Post)
This explanation aligns with the issues we’re experiencing with our machines. The scenario I described is happening with one of them (let’s call it Machine A). This machine is identical to another one (Machine B), except for some custom code that facilitates communication with an external Beckhoff PLC for MES integration in the production line. Machine B has been powered on and off daily for at least three months and has never had this problem. Given that, I highly doubt the MES custom code is the cause of the code corruption. This being said, your explanation does seem plausible. However, if faulty EtherCAT cables were the issue, why wouldn't the error occur during normal operation? Why would bad cables only cause problems during a hard shutdown? One last question: When you encountered this behavior, did you see a similar error in your logs? i.e, an "AccessViolation" exception in the EtherCAT Task?
Last updated: 2024-10-03

Post by mavitia on Application based license problem - Modbus TCP CODESYS Forge talk (Post)
I am running ubuntu on a raspberry pi, and installed an application based license Control Basic M on it, it runs a demo program fine, does not timeout etc. however, when I add a modbus TCP device, I start getting errors: <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="24">Online change denied. Application Application is in exception state!</Entry> <Entry severity="error" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:42 PM" infoId="68">Download failed: Application=Application</Entry> <Entry severity="exception" component="CmpApp" user="nobody" timestamp="12/18/2023 3:49:41 PM" infoId="0">Application app=Application has invalid license metrics!</Entry> the modbus tcp slave runs, and the counter ticks up, however, when I call the variables on the %IX0.0 in my program, and try to upload the changes, I am getting the error messages which stop the program as far as I understand, the application based, M includes 2 fieldbus instances, but on the other side is fairly new, anything obvious I am missing out here?
Last updated: 2023-12-18

Post by spiessli on Softmotion axis to CANopen Maxon IDX drive CODESYS Forge talk (Post)
Thanks for the advise, indeed, this was somewhat, what my intention was. I tried around again with EDSes and DCFs, anyway. It appears that the DCFs end up in a subfolder in the attach device dialog. Astonishingly, when attaching the DCF version I get a device in the device tree, where I can add a SoftMotion axis, whereas when I attach the device not in the subfolder, then I cannot. Further astonishingly, when looking in the CANopen parameters in supported profiles, "402" is listed in the case of the DCF variant, whereas in the EDS variant "0" is shown. Comparing EDS and DCF files I cannot guess, where the difference is coming from. I cannot tell either why I have always attached the EDS variant and apparantly never the DCF variant. As I am not in the lab right now, I cannot test if the connection actually is working. Thanks again, spiessli
Last updated: 2024-01-07

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via CmpApp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by markushunter on Different behavior between the "Start" button in the IDE and the Cmp function "AppStartApplication()" CODESYS Forge talk (Post)
In our application with CODESYS V3.5 SP19 Patch 5 and the Soft-PLC Name: CODESYS Control Win V3 x64 Typ: 4096 ID: 0000 0004 Version: 3.5.19.50 the application behaves differently when we start the application via Cmp.AppStartApplication(pApp) than when we press the "Start" button in online mode in the IDE. Unfortunately, it looks like the AppStartApplication() function, which is called in the "StopDone" system event, is not able to restart the fieldbus driver correctly, in our case the EtherNet_IP_Scanner: Name: EtherNet/IP Scanner Hersteller: 3S - Smart Software Solutions GmbH Kategorien: EtherNet/IP Scanner Typ: 100 ID: 0000 100B Version: 4.5.1.0 Bestellnummer: 1 And one EtherNet/IP adapter Name: FANUC Robot R30iB Plus Hersteller: FANUC Robotics America Kategorien: EtherNet/IP Remote Adapter Typ: 101 ID: 356_12_4_3 Version: Major Revision=16#3, Minor Revision = 16#1 Beschreibung: EtherNet/IP Target imported from EDS File: fanucrobot0301_r30ibp.eds Device: FANUC Robot R30iB Plus Version Konfiguration 3.5.6.0 The application was cold reset in both cases via CmpApp.AppReset(pApp := pApp, usResetOption := CmpApp.RTS_RESET_COLD. Does anyone know the difference between the functions or services executed by the "START" button in online mode and Cmp.AppStartApplication()? Thanks and best regards, markushunter
Last updated: 2024-03-20

Post by bschraud on Code erzeugen mit kryptischer Fehlermeldung mit GVL_Io_dd05d808 CODESYS Forge talk (Post)
Hallo, beim Codeerzeugen bekomme ich wiederholt Fehlermeldungen, bei denen nicht mit einem Klick in das betroffene Modul gewechselt werden kann. Die Fehlermeldung tritt allerdings nach "Gerät aktualisieren" nicht mehr auf. Wenn ich das Projekt speichere, Codesys schließe, anschließend Codesys wieder starte und Code erzeugen will, tritt der Fehler wieder auf: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... [FEHLER] PAC: C0032: Typ 'Unbekannter Typ: 'ADR(GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7)'' kann nicht in Typ 'POINTER TO IoConfigParameter' konvertiert werden [FEHLER] PAC: C0077: Unbekannter Typ: 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7.Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' [FEHLER] PAC: C0046: Bezeichner 'GVL_Io_dd05d808_33e6_4f6b_ba3a_6ba1d0dcc882_HPS_7' nicht definiert Kompilierung abgeschlossen -- 3 Fehler, 1 Warnungen Übersetzung abgeschlossen -- 3 Fehler, 1 Warnungen : Kein Download möglich Die Recherche nach der Bedeutung von "HPS_7" oder "GVL_Io_dd05d808" verlief leider ergebnislos. Ich habe nur einen ähnlich erscheinenden Thread gefunden, der aber nicht gelöst wurde: https://forge.codesys.com/forge/talk/Engineering/thread/0666dce94f/ Ich verwende Codesys 3.5 SP20 (64bit) mit CODESYS Control for Raspberry Pi MC SL 4.11.0.0. Alle anderen Geräte sowie die Projektumgebung sind frisch aktualisiert. Kennt jemand die Bedeutung dieser Fehler bzw. wie man sie beheben kann? Vielen Dank für die Hilfe
Last updated: 2024-05-16

<< < 1 .. 230 231 232 233 > >> (Page 232 of 233)

Showing results of 5806

Sort by relevance or date