Post by nz-dave on Ethernet/IP Scanner Exception
CODESYS Forge
talk
(Post)
HI I have had a project running for a few weeks and twice it has shut the program down due to this exception. exception[ProcessorLoadWatchdog] occurred in: App=[all], Task[all] I have to reboot (power cycle) the system to clear the exception. or remotely restart the application. Any ideas? Cheers
Last updated: 2024-11-16
Post by rafaelbrito on Integration C Code
CODESYS Forge
talk
(Post)
I tried to use C code in the library that I have been developing in the project, but without success. I tried to use the CODESYS Control SL Extension Package to generate XXXdep.h and XXXltf.h, but without success. Do you have a better example of how to generate these files and how to compile them?
Last updated: 2024-12-03
Post by xabier on Kinematics Robot Delta 2 Axis
CODESYS Forge
talk
(Post)
Hi, I have a customer and this customer design this robot...The customer need move ...I would like if Codesys has this Kinemtaics I attached photo of the robot.(this robot has 2 Axis) I have checked all kinematics has Codesys but not has the same....Someone help me Please?? Thanks XABI
Last updated: 2024-12-11
Post by daniel on Codesys Tools Update Raspberry ist nicht vorhanden aktualisieren im Geraete ansicht geht auch nicht
CODESYS Forge
talk
(Post)
Guten Tag, ich habe das gleiche Problem nur mit der 20.4 Version. Über den Installer habe ich alles installiert allerdings erscheint bei mir unter Tools nicht die Möglichkeit den Raspberry zu aktualisieren. Mit der 19.7 habe ich das gleiche Problem. Muss noch etwas anderes installiert werden? Kann mir jemand weiterhelfen? Grüße Daniel
Last updated: 2024-12-13
Post by durallymax on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
WAGO will use 0-32767 as the raw units. Note a value of 3 means over/under range. Map that IO however you please, then scale in your program using any of the available libraries or with your own simple y=mx+b scaling formula to get to the engineering units you desire. Inverse for the AO to get back to 0-32767.
Last updated: 2024-12-15
Post by bjarne-pagaard on Newly created texlists wont appear in the selection dropdown
CODESYS Forge
talk
(Post)
I just had the same problem in 3.5 SP19 Patch 6. Trying to use a textlist for Combobox Integer element. The textlist cannot be selected in the IDE, and is not found when manually entering the name. The textlist is copied to the device, but is not used. Can confirm, that copying an existing textlist and renaming it does work.
Last updated: 2024-12-16
Post by totorovic on Project loses 'Download time' information
CODESYS Forge
talk
(Post)
I continue this topic by myself, I'm very happy with the Codesys support / community ;-) This information (Download time) should be stored in the compileinfo : https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_load.html But the file is not text-readable (see attached file) so how to solve if download time is empty?
Last updated: 2024-12-19
Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera
CODESYS Forge
talk
(Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26
Post by mtnkyr on Runtime Problem connecting to Keyence IV-500MA Camera
CODESYS Forge
talk
(Post)
I have to use Keyence IV-500MA Camera for a project. Actually I can use physical connection but I tried to connect using Ethernet protocol so I added its EDS file but I took a lot of errors. Could you help me to solve this problem?
Last updated: 2024-12-26
Post by conny-nm on Bosch BME 280 bzw 688 Sensor per I2C Bus steuern und Daten in Codesys verarbeiten
CODESYS Forge
talk
(Post)
Hallo Markl, gibt von Stefan Dreyer auf Git Hub Biblioteken für BMP280 und BME280, laufen aber nur in 32Bit auf dem Raspberry. BME680 kann man mit Node Red auslesen und mit mqtt zu Codesys übertragen.
Last updated: 2025-01-07
Post by winki on Not Possible to connect using control SL
CODESYS Forge
talk
(Post)
Hello, I used to connect into my gateway using control SL tool 4.13, (it was called Update Linux.) I formated my computer, so today I install the new version of codesys and all package. Now I am not able to connect to my PLC using control SL. It says, check the status. Normally it used to worked perfectly before that.
Last updated: 2025-01-07
Post by timvh on PLCOpenXML Export/Import with Visualisation
CODESYS Forge
talk
(Post)
A Task is a standard IEC 61131-3 object, so logically that you can export the VISU_TASK. A visualization is no standard IEC 61131-3 object, so not compatible with other IEC tools. Just use the standard export / import functionality. These files are not IEC compatible and can only be used in CODESYS. But these do support visu objects.
Last updated: 2025-01-09
Post by timvh on Colors look different when logged in and running
CODESYS Forge
talk
(Post)
At the top of the Visualisation Properties View, you can enable the "Advanced" options. This will give you access to more properties than what you currently see. There might be a variable linked to the "advanced" colour property where the fill colour is determined by the value of this variable (dword).
Last updated: 2025-01-09
Post by timvh on Library ENUM text representation in visualization
CODESYS Forge
talk
(Post)
Probably the enum from the library doesn't have text support. In that case you need to add your own TextList to the application. In the rectangle you should use the property "dynamic text" to link this object to the textlist which you have created yourself and then link the text index to your enum variable.
Last updated: 2025-01-09
Post by gseidel on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
Hi Gustavo, can you reduce the problem to a project that reproduces the issue without the real servo drives? (You could set the servo drives to virtual and strip away as much as possible from the application.) If you can attach a project, we will have a look. Best regards, Georg
Last updated: 2025-01-10
Post by ekristoffe on Modbus UDP
CODESYS Forge
talk
(Post)
UDP has no packet ordering mechanism, and Modbus protocol has no order checking mechanism nor session establishment. I'm sorry but this is false, Modbus IP based have the Transaction Identifier. Transaction Identifier - It is used for transaction pairing, the MODBUS server copies in the response the transaction identifier of the request. Modbus UDP make more sense than Modbus TCP in a local environment.
Last updated: 2025-01-14
Post by pernockham on Preferred way of managing Ip-adress/es for linux (debian) host?
CODESYS Forge
talk
(Post)
I have a debian linux host running Control SL. I tried to manage IP-addresses through codesys/Control SL but that was not successful. What works though is manually editing the network-interfaces config file. /etc/network/interfaces. Is there a way to set this up so that IP-addresses can be managed from within codesys instead? Thanks! / Per
Last updated: 2025-01-22
Post by jddaigle on Webvisu not supported due to missing browser feature HTML5-Canvas
CODESYS Forge
talk
(Post)
Hello, I'm running the lastest version of Codesys 3.5 SP20 Patch 5, with the lastest version of Chrome. And I still get this "Webvisu not supported due to missing browser feature HTML5-Canvas" fallback with a quite simple webvisu containing some buttons, images, textboxed and a grid. What can I do? is that a configuration to change? Thanks!
Last updated: 2025-01-24
Post by spiritcore on Server not adding PLC
CODESYS Forge
talk
(Post)
I added new Gateway and I can see it connected. When I scan the server for PLC, it finds the PLC but when I click the Add To Server button, it shows "PLC was added." in the status. But I can't find the PLC in the list. I tried removing the gateway and re-configure everything again but it didn't solve. Any ideas?
Last updated: 2025-02-17
Post by jeffersonhui on SP20 Visualization Element Dynamic Colors
CODESYS Forge
talk
(Post)
I am using Codesys SP20 patch 5 and in a visualization element, the "Color variables" section does not have a section to set up dynamic color values linked to variables. In a previous version (SP18), I get the option to add variables for Normal & Alarm state colors. Does anyone know how to get the dynamic color variables to work?
Last updated: 2025-02-19
Post by timvh on TargetVisu started in windowed or not full screen
CODESYS Forge
talk
(Post)
In your soft plc folder, there is a file called targetvisuextern.cfg. Open this with a text editor to change the settings. Remove the semi-colons in front of the lines to enable your custom window settings. WindowType=0 means you will get a moveable window. Save the file and restart the soft PLC to enable these settings.
Last updated: 2025-02-26
Post by somlioy on CODESYS Control for PFC100 SL Firmware upgrade
CODESYS Forge
talk
(Post)
Hi We delivered a system with a PFC100 using the CODESYS Control for PFC100 SL runtime a few years back. The system has once been decommissioned and are now to be commissioned again. Back then, there were only single licenses for the runtime. Can I now upgrade the firmware and runtime without purchasing a new license?
Last updated: 2025-02-27
Post by helcioburd on How long can a WSTRING be in CodeSys V3?
CODESYS Forge
talk
(Post)
Thank you, very useful information. I did a library for serial communication and could not understand the reason only 256 chars could be read (after sending more than 256). Following your suggestion, I can now send any number of chars and everything will be received.
Last updated: 2025-03-02
Post by cellohorst on File Creation Issue
CODESYS Forge
talk
(Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03
Post by domebruce on Which database to use?
CODESYS Forge
talk
(Post)
We have developed a similar application few years ago with .Net and MS Sql Server. The database has about 30 tables, the more bigger tables have 2 or 3 thousands records. We can have multiple threads accessing at the same time to the DB. To garantie the data integrity we need to manage data locks and transactions. Thanks
Last updated: 2025-03-04