I ran into a problem. Uploaded an example (https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_uacapi_example.html) After launch. on the emulator. I see that I am having problems: - UaExpert does not connect. There are many servers but no connection. - I can’t transfer the certificate from quarantine to trusted ones. There is some problem with creating the certificate. CS 19.2. If anyone has had similar problems, please give me advice. Thank you.
Last updated: 2024-05-20

Post by shebi87 on Program from one PLC to other WAGO 750-8204 CODESYS Forge talk (Post)
Hello Everyone, 750-8204 was installed on a machine and it becomes faulty. We have arrange a new PLC from local market we don't have PLC program but thanks to our other machine which has the same PLC running I want to upload the program from that running PLC and download it to new PLC can anyone tell me the procedure please?
Last updated: 2024-05-21

Post by tba123 on Script engine, git checkout, Project Environment CODESYS Forge talk (Post)
Hi, I clone a git repository with VersionUpdateFlags.SilentMode, works fine But now I want to checkout a specific commit (with branch_copy command). When using the branch_copy command there is no VersionUpdateFlags and I get this annoying "Project Environment" prompt, blocking further execution of my script without user input. I already tried something like system.prompt_answers[???] = PromptResult.Cancel but I don´t know the string I need here.. The goal is to have a script that clones a repository and compiles every tag + create compiled libraries.
Last updated: 2024-06-10

Post by mozed on Bug Device login CODESYS Forge talk (Post)
Good morning, The problem I encounter is very disturbing, when I try to connect to my project, it asks me to put in my username and password, which I do. However, I cannot connect and it restarts. the window to rewrite my identifiers. However it is the correct identifier and password I do not understand why. When I try to put false identifiers there strangely it tells me that these are not valid identifiers. There is something what can I do? Sincerely
Last updated: 2024-06-11

Post by arcadium on TargetVisu element stacking on top of each other CODESYS Forge talk (Post)
Hello, I'm new here so if I do something wrong please bare with me. I am using raspberry pi touchscreen made by comfile (CPi-C070WR4C). I also have a window 11 pc where I would like to have a second visualisation, but when I run a TargetVisu with it, all elements of the visualisation end up in the top left corner stacked on top of each other. I have same results running targetVisu on my laptop. Maybe someone had same issues and know the solution? Simas
Last updated: 2024-06-17

Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
Hi We have picked up an issue OSCAT_BASIC.Scale_r function call not working in the old lad and FBD version 4.60. Gives no output on the function call. When we convert this to LAD2 it works. As can be see by the two screenshot in normal LD not working in LAD2 it works. Please confirm if this is an issue with Oscat or with LAD in 3.5.21sp3, is there an workaround. Regards Shaun
Last updated: 2025-10-23

Post by shaunvdm on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3 CODESYS Forge talk (Post)
Hi We have picked up an issue OSCAT_BASIC.Scale_r function call not working in the old lad and FBD version 4.60. Gives no output on the function call. When we convert this to LAD2 it works. As can be see by the two screenshot in normal LD not working in LAD2 it works. Please confirm if this is an issue with Oscat or with LAD in 3.5.21sp3, is there an workaround. Regards Shaun
Last updated: 2025-10-23

Post by kenth1973 on MC_Phasing state explenation CODESYS Forge talk (Post)
Hi Georg OK got it, thank you. I respect your (CODESYS) policies on that issue. Will try to update according to your recommondation if the customer experience same error in the future. Though - from within my coding heart it does bother me deeply, that I cannot get further understanging/knowledge on the iPhasingState, but I guees I will have to swollow that bitter pill and get on with it! hehe ;-)
Last updated: 2025-12-17

Post by ryusoup on 'keep last value' option in CODESYS EtherCAT CODESYS Forge talk (Post)
Hello, I’m using CODESYS EtherCAT Master on a Raspberry Pi controller with several remote I/O modules. I’m facing an issue where the input values from the remote I/Os drop to 0 when a connection error occurs. Is there a way to configure a “keep last value” behavior (i.e., hold the last valid input) instead of defaulting to 0 on communication loss? Best regards,
Last updated: 2025-11-18

Post by luca03 on OPC UA information model into the Communication Manager CODESYS Forge talk (Post)
Hello, unfortunately I am unable to load an OPC UA information model as a NodeSet2.xml file into the CODESYS Communication Manager. Importing via Tools -> OPC UA Information Model Repository still works, but when I try to load the model explicitly, CODESYS crashes without displaying an error message. Has anyone else encountered this problem, or does anyone have any suggestions? Thanks in advance
Last updated: 2026-08-22

Post by gland on Open project automatic with correct version CODESYS Forge talk (Post)
Goodmorning, The projects we have made (with several persons) are in differents versions, Codesys V3.5 sp18 patch4, V3.5 sp19 patch 2, V3,5 sp19 patch 5 etc V3.5 sp21 patch 3 etc.. Now when we're opening an project thats's not opend before on my pc and we're not sure in witch version it's made it's quite annoying. We don't want to update to the newest version. Is there a way that it's automatic opening the correct version? Is there a program/tool/easy way to do this? Thanks,
Last updated: 2026-01-27

Post by nehaltrivedi96 on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
Hello, I am currently scaling 4-20mA signals and the scaled output (temperature) has to be sent via modbus protocol to a tool like doctor modbus or modbus poll. I have defined my inputs as real as and the output is also real, but to send this output via modbus it has to be of word. So how will i convert real into word and then send the generated output via modbus?
Last updated: 2026-02-18

Post by sulzbrunn on Codeys Installation freezes while attempting to install packages CODESYS Forge talk (Post)
Hi, I am facing the same problem: I am trying to install CODESYS 3.5.17.60 The last log entries are: ... InstallShield 14:18:17: Done Initializing... InstallShield 14:18:17: Registering Msi Server... InstallShield 14:18:17: Invoking script function InstallOEMPackages 1: [CDS Info]: CDS_OEMPACKCOUNT: 47 1: [CDS Info]: CDS_OEMPACKCOUNTALL: 47 Action 14:18:17: CDSInstallOEMPackages. Install all Packages added to the setup 1: [CDS Info]: Call: C:\PROGRA~2\CODESY~1.60\CODESYS\Common\PACKAG~2.EXE --profile="CODESYS V3.5 SP17 Patch 6" --installAll="C:\Users\UserXXX\AppData\Local\Temp{94C03~1\Packages"
Last updated: 2026-03-19

Post by risele on Modbus connection via Qronox PCD3 M6893 CODESYS Forge talk (Post)
First, if you don't need to change conversion rules in runtime, take a look at "Unit conversion" module (Application -> add object -> UnitConversion). You can specify there biderectional conversion with different units, limits and so on. Second, since MODBUS don't have "real" types but only general 16-bit registers and Real is 32-bit, generally you need a byte-was conversion Real <> two Words. Note, that depending on the devices on both sides, there are two options: Real-> Word1, Word2 or Real-> Word2, Word1, where Word1 is minor register in Modbus register pair and Word2 is major. You can use simple union: TYPE u_Real : UNION rVal:REAL; wVal:ARRAY[0..1] OF WORD; dwVAL:DWORD; //same as previous, may be easier to specify the MB register END_UNION END_TYPE and convert it as following: VAR myUnion:u_Real; rValue_TO_SEND:REAL; rValue_TO_GET:REAL; END_VAR myUnion.rVal:=rValue_TO_SEND; rValue_TO_GET:=myUnion.rVal; Note, that WORD-order should be properly set in MODBUS registers, otherwise you will get strange values. This tool is helpful: https://www.scadacore.com/tools/programming-calculators/online-hex-converter/ Alternative, you can use functions as REAL_TO_DW and DW_TO_REAL from OSCAT_BASIC, for example.
Last updated: 2026-02-19

Post by vincentger on Raspberry Pi Control SL MC - Restoring License not working anymore! CODESYS Forge talk (Post)
Running into the same problem restoring a Runtime 4.4.0.0 device on a now 4.8.0.0 device.
Last updated: 2023-08-21

Post by eschwellinger on Raspberry Pi Control SL MC - Restoring License not working anymore! CODESYS Forge talk (Post)
you need to use 'my question ' in the CODESYS store
Last updated: 2023-08-24

Post by smercante on Unable to Import PLC Open XML from Easy Remote IO CODESYS Forge talk (Post)
Hello dear. I have the same problem. Could you solve it? Do you use GLV variables?
Last updated: 2023-08-24

Post by gregor on PFC 200 - codesys V3.5 CODESYS Forge talk (Post)
As far as I know, only if someone downloaded sourcecode to the PLC.
Last updated: 2023-08-25

Post by totorovic on CSVReaderInit returns error : INVALID_HANDLE CODESYS Forge talk (Post)
Hello, Can we please have some details about the error : INVALID_HANDLE? So we can try to avoid it.
Last updated: 2023-08-28

Post by marekxc on Trun off webvisu CODESYS Forge talk (Post)
Click Visualisation with the left mouse button. Next click right mosue button Select Properties In window select TAB Build and Select "Exclude from Build"
Last updated: 2023-09-01

Post by eschwellinger on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
check the plclogger and use top or htop in by ssh ( which runtime version is this?)
Last updated: 2023-09-23

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
How do I found out, which process is taking the load?
Last updated: 2023-09-27

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Okay, i've extendet ist from 6000 to 20000, but the error is still present :-(
Last updated: 2023-09-28

Post by armall on USB <-> CAN, CANfox, Component CmpCANFoxDrv NOT loaded CODESYS Forge talk (Post)
Hi, I'm at the same stage as you. Wondering did you every get a solution?
Last updated: 2023-10-13

Post by eschwellinger on Delete PLC Log CODESYS Forge talk (Post)
logger is a ringbuffer - means depends on your settings - how fast the files will be overwritten - but this should never lead to PLC hangs
Last updated: 2023-10-16