Post by ragarcia on Error while using UpdateConfiguredIPSettings to change IP address
CODESYS Forge
talk
(Post)
Hello everyone, I am trying to change dynamically by code the IP address of a Weidmuller controller. So I am basically using IoDrvEthernet library to use UpdateConfiguredIPSettings function but I am getting constantly the 'INVALID_STATE' error. Even though I am following a procedure it should work: * First I added on the config file of codesys the following: [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="eth1" Adapter.1.EnableSetIpAndMask=1 * Secondly I am first disabling the ethernet interface by using Ethernet_0.Enable = FALSE and then executing DED.Reconfigure. After that, I run the Ethernet_1.updateConfiguredIPSettings Code: Ethernet_1.Enable:= EnableDisable; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1, xError=> ErrorReconfigure, eError=> ErrorCodeReconfigure); IF Reconfigure.xDone THEN ErrorCodeIP:= Ethernet_1.UpdateConfiguredIPSettings(IPAddress:= newIP, SubnetMask:= newMask, Gateway:= newGW); END_IF IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Ethernet_1.Enable:= TRUE; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1); IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Can someone help me? Thank you. All I am trying is to find a way to change dynamically with code, the IP addresses of my controller (2 ethernet ports).
Last updated: 2023-12-11
Post by vipul on Multicast udp
CODESYS Forge
talk
(Post)
Hi, Good afternoon can anybody help me with UDP Multicast code. I am not able to send or recieve data when code is dumped on linux device. Below is my code. Declaration: PROGRAM udp_multicast VAR oneTimeFlag :UINT :=0; state: INT:=0; driver: UDP.UDPDriver; //port : UDP.Port;//moved to GVL src_ipAddr_ud: UDINT; src_ipAddr_st:STRING := '192.168.127.155';//'192.168.1.155';//ipms ip address dst_ipAddr_ud:UDINT; group_ipAddr_st:STRING := '239.1.5.10'; //group_ipAddr_ud:UDINT; result: SysTypes.RTS_IEC_RESULT; //result of recieve function. bind: UDINT; //result of binding. resultCreate:SysTypes.RTS_IEC_RESULT;//result of port creation. timer:BLINK; temFlag :INT:= 0; post:INT :=0; checksumFunc:checksumXor; localStringBuf:STRING[500]; chksum:BYTE; dataBuffer:POINTER TO BYTE; checksumString:ARRAY[0..5] OF BYTE; recvSize:__XINT; errorCode:UDINT; joinGroupErrorCode:UDINT; END_VAR ************8 Implementation: IF oneTimeFlag <> 1 THEN oneTimeFlag:=1; resultCreate := driver.CreatePort(ADR(GVL.port)); src_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIPAddress:= src_ipAddr_st); GVL.group_ipAddr_ud := UDP.IPSTRING_TO_UDINT(sIpAddress:= group_ipAddr_st); GVL.port.IPAddress := src_ipAddr_ud; GVl.port.ReceivePort:= GVL.src_port;//port on which messages are expected. GVl.port.SendPort := GVL.dest_port; GVl.port.OperatingSystem := 0; //0- any system GVL.port.Socket :=3; //3- socket type is multicast bind := GVL.port.Bind(udiIPAddress:=src_ipAddr_ud,); GVl.port.JoinGroup(udiGroupAddress:= GVL.group_ipAddr_ud,udiInterfaceAddress:= src_ipAddr_ud,eLogCode=>joinGroupErrorCode); END_IF timer(ENABLE:=TRUE,TIMELOW:=T#100MS,TIMEHIGH:=T#100MS); IF timer.OUT = TRUE THEN GVL.port.Send(udiIPTo:=GVL.group_ipAddr_ud,GVL.dest_port,pbyData:=ADR(GVL.writeData),diDataSize:=SIZEOF(GVL.writeData)); ELSE SysMemSet(ADR(GVL.readData[0]),0,SIZEOF(GVL.readData)); result := GVl.port.Receive(ADR(GVL.readData),diDataSize:=SIZEOF(GVL.readData),udiIPFrom=>dst_ipAddr_ud,diRecvSize=>recvSize,eLogCode=>errorCode); SysMemMove(ADR(GVL.readDataBuf[0]),ADR(GVL.readData[0]),SIZEOF(GVL.readData)); END_IF post:=LEN(GVL.readDataBuf);
Last updated: 2024-01-14
Post by axilleas on SMC_Interpolator + SMC_controAxislbyPos
CODESYS Forge
talk
(Post)
dear all I am working on a very generic gantry system (virtual drives + win v3 control) reading gcode from external file. In order to stop the interpolator function from running when gaps are detected, SMC_controlAxisByPos FB has the bStopIpo output which according to the manual is connected to the Interpolator's bEmergencyStop. Lets assume that the axis are parked in position X1000 Y1000 and the initial G code movement is G00 X500 Y500. The normal behavior is to travel from the actual x1000 y1000 to G00 X500 Y500. The SMC_Interpolator always gets the X0 Y0 as the initial position, meaning that the bStopIpo is active until the axis are in X0 Y0 and the release the interpolator to set the new positions to X500 Y500. Is there a suggested method to solve this behavior? bonus question: I get a lot of bStopIpo during standard interpolation movements (not gaps). While working with virtual axis this is not a problem but when real axis are installed this will be an issue. What exactly triggers the bStopIpo output? Slow axis accelerations compare to Gcode defaults? Kind Regards
Last updated: 2024-02-05
Post by brell on Automatic xExecute NBS.TCP_write
CODESYS Forge
talk
(Post)
I've recently started experimenting with CODESYS for a project and am fairly new to it. I'm currently working with Function Block Diagrams (FBD) to set up TCP communication between a server and a client, where the client is implemented as a Python script. Once the communication is established, my connection status changes to True, which is the expected behavior. My challenge arises with the TCP write module, which requires the xEnable_write flag to toggle between True and False. If xEnable_write remains True, the module only performs a single write operation. To address this, I introduced a falling edge trigger (F_TRIG), expecting it to help in toggling xEnable_write and it does, However, I've encountered an issue where in the beginning after connxion established I need to manually set xEnable_write to True for the system to work as intended. I'm looking for a way to automate this process so that xEnable_write becomes True automatically upon establishing a connection . Initially, I tried setting xEnable_write to True from the start, but this approach didn't work well since it left the flag permanently True, preventing further toggling. I also experimented with using a TON timer, but I faced similar issues. I am seeking a solution that automatically toggles xEnable_write between True and False after a connection is established, ensuring continuous write operations without manual intervention. Any advice or guidance on how to achieve this would be greatly appreciated."
Last updated: 2024-03-05
Post by mtho on JSON Utilities - JSON file written with invalid structure
CODESYS Forge
talk
(Post)
I'm using the JSON Utilities SL library to write configurations in my program to a file. I'm generating the JSON data using the builder function block and all appears to work correctly. When I write the jsondata to file, I'm finding that some of the JSON elements are not being written in the right location in the file. Rather than writing they keys under the parent object, they get written outside the root JSON object at the end of the file. If I then try to read the file back into the program, I get an invalid_structure error. I don't get any errors when populating the JSON data or when writing the file. I attached an example of the JSON writer output. The problems begin with key P200. Each P200 should go under MBR1 through MBR3. Among the rest of the keys, they are supposed to be under different parent objects. I am using default values for wsLineBreak and encoding.
Last updated: 2024-03-06
Post by tomast on Codesys and Siemens SINAMICS 20 modbus RTU "Response CRC Fail"
CODESYS Forge
talk
(Post)
Hi everyone, I'm currently working on a project involving the control of 5 VFDs via Modbus RTU, this time using the WAGO 750-8212 CPU. So far, I've managed to make progress, but I've encountered an issue. While I can successfully read and write to all the registers I need, I consistently encounter a "Response CRC Fail" error when attempting to write the value 1151 to the STW register at address 40100. I'm able to set the frequency via register 40101 and adjust all other parameters using different registers. Setting STW to 1150 results in the drive ready boolean from the ZSW-bit being received instantly. However, the moment I attempt to send 1151 to register 40100, I immediately receive the "Response CRC Fail" error for all channels. I've also attempted to use combined control, employing Modbus for frequency control and starting from a digital input. Everything seems to function properly until I send the start command to the VFD. Interestingly, I consistently encounter the same error the moment I send the start command, regardless of whether I use register 40006 (high) or 40100 (1151). Could someone please assist me in resolving this issue?
Last updated: 2024-03-21
Post by danieldiaz on Problem with FB execution
CODESYS Forge
talk
(Post)
Hello everyone, I've been working on a system which needs an error function, with this purpose I've created a FB programmed in LD, after debugging I run the simulation. It seems that the variable linked to a coil doesn't change the value when the contacts are associated to input variables. When I use internal variables the logic works properly. I don't know if the problem is related to the variables definition or with the logic program. As you can see in the image, I1 and I2 are variables declared on the FB, the rest are input variables. If I force the eStop and Reset signals to TRUE the coil value should change, but it doesn't. However in the second network if I1 is TRUE the coil change to TRUE as it has to be. To sum up, my doubt is why that coil doesn't change its value? I would like someone to shed a light on this. Thanks!
Last updated: 2024-04-02
Post by alexgooi on Modbus writing on value change
CODESYS Forge
talk
(Post)
Hi Duvan, You could make this in 1 single object (FB), Indeed don't use a function for this beacuse you need some memory to keep the old value. For i := 0 TO 200 BY 1 DO //Check if the value has been changed IF Old_Value[i] <> Value[i] THEN //Set the trigger to TRUE Trigger[i] := TRUE; Old_Value[i] := Value[i]; END_IF END_FOR If you define the Value array as an In_Out and the Trigger as an In_Out you arn't claiming any aditional memory to your system. You ofcourse then need to add some code arround it that does something with the trigger and writes it back to FALSE again. If you want more flexability you also could use pointers instead of using the IN_OUT FOR i := 0 TO 200 BY 1 DO address := address_Input + i * SIZEOF(*Put type here); IF Address^ <> Old_Value[i] THEN Trigger[i] := TRUE; Old_Value[i] := Address^; END_IF END_FOR
Last updated: 2024-04-02
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page
CODESYS Forge
talk
(Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15
Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors
CODESYS Forge
talk
(Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02
Post by hanoues on setting date and time on CPX-E
CODESYS Forge
talk
(Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21
Post by william-blandon on RecipeManCommands.ReloadRecipes
CODESYS Forge
talk
(Post)
Hi Dave. Thanks for your answer. I still struggling with this. I have done everything according with the Codesys help even I have looked in detail at the example. I have double checked the recipe manager configuration and the use of all the methods. There are two methods that do not work as expected. I'm using Codesys 3.5.19.20 and recipe management 4.4.0.0 .CreateRecipe just create a recipe in the recipe definition but do not create the file. This have a walk around just giving a .ReadAndSaveRecipe afterwards. .ReloadRecipes do nothing but do not generate any error as well. After calling it I call the .GetRecipeCount and the number is always 0. When I create a new recipe (using the function block methods) then the number changes. Looks like this method is looking to the wrong directory finding nothing. I don't know if there is a missing configuration in the CODESYSControl.cfg file. I'm thinking in a walk around for this but I need to create a strings array with the recipe names as retentive and making all the management when deleting and adding recipes. Have had some one the same problem?
Last updated: 2024-05-23
Post by abinvest579 on TCP Client
CODESYS Forge
talk
(Post)
Hi All, I am using codesys based plc to read and control magna power DC supply over LXI protocol using SCPI command. To connect device required socket programming for that i am using Net base service library function block TCP_Client to establish connection over TCP/IP , TCP_Write to write SCPI commands and TCP_Read to read data from Magna power DC supply. I have attached screenshot for logic developed. I am able to connect and write commands to device but i not receiving any information from device. For writing Commands i also tried various end of line character like \n,<nl>, A, D, 10, 13, 0x0A, 0x0D but not received any status from device. For testing purpose i am using simple command '*IDN?' to read data. Also if tried to check on hercules software what data actually plc read, first it read correct data after that is read wrong data as see in screen shot. 'Hello World' was correct read and after that Codesys in replaced with 'Codesysorld' that is not correct way. Same issue also appeared for send data. Any one have face same issue how i can read data directly from device correctly and send data please suggest solution on this.</nl>
Last updated: 2024-07-01
Post by timvh on How to implement an interface (IElement)?
CODESYS Forge
talk
(Post)
See: https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ This contains an application "OnlineChangeSafeLinkedListExample". What you should do is create a new interface which has your "Priority" property. Then your FB should extend the base element function block and implement your own interface: E.g. FUNCTION_BLOCK MyElement EXTENDS COL.LinkedListElementBase IMPLEMENTS I_MyInterface Then the __QUERYINTERFACE does the magic to check if your "element" also implements your interface. Something like this: // Compares this element with itfElement. // Returns 0 if the elements are equal, < 0 if the element is less than itfElement, // > 0 if the element is greater than itfElement. // This method will be called from sorted collections (e.g. |COL.SortedList|) to sort the elements. // IMPORTANT: The underlying value to be compared with MUST NOT be changed during the lifecycle of the object. METHOD ElementCompareTo : INT VAR_INPUT (* The element to compare*) itfElement : COL.IElement; END_VAR VAR itfIntElement : I_MyInterface; xResult : BOOL; END_VAR // We use integer iInt1 for sorting. xResult := __QUERYINTERFACE(itfElement, itfIntElement); IF xResult THEN IF iInt1 < itfIntElement.Priority THEN ElementCompareTo := -1; ELSIF iInt1 > itfIntElement.Priority THEN ElementCompareTo := 1; ELSE ElementCompareTo := 0; END_IF ELSE ElementCompareTo := -1; END_IF
Last updated: 2024-07-22
Post by ruobian on Analog Input Delay Timer
CODESYS Forge
talk
(Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20
Post by scoob on ModbusFB - Slow Response Time
CODESYS Forge
talk
(Post)
Hello, I have been trying to use the ModbusFB functions so I can put some code into libraries, but it seems to be very slow for me. I have a Modbus device with 100ms registers. I previously setup 10 channels in the 'traditional' Modbus Slave with channels and mappings - and set a cyclic trigger at 100ms - this worked fine. I then tried the ModbusFB example, and setup reading the same 10 blocks of modbus addresses, copying the example and putting all of the requests into an array and triggering the requests sequentially. I timed how long the requests are taking to get round to each one, and it is around 1s 450ms. How do I speed this up to match the cyclic time? IF NOT(init) THEN init := TRUE; // Set the required IP address: ipAddress[0] := 192; ipAddress[1] := 168; ipAddress[2] := 1; ipAddress[3] := 10; // Pass the required IP address to the clinet FB: client_NetworkSwitch.aIPaddr := ipAddress; client_NetworkSwitch.udiLogOptions := (ModbusFB.LoggingOptions.ClientConnectDisconnect OR ModbusFB.LoggingOptions.ClientReceivedValidReplies); // Try to connect the client client_NetworkSwitch(xConnect:=TRUE); // Configure all the channels to read connecting them to the client: portStatus_Request(rClient := client_NetworkSwitch, uiStartItem := 4096, uiQuantity := 32, pData := ADR(portStatus), udiReplyTimeout := udiReplyTimeout); portSpeed_Request(rClient := client_NetworkSwitch, uiStartItem := 4352, uiQuantity := 32, pData := ADR(portSpeed)); flowControl_Request(rClient := client_NetworkSwitch, uiStartItem := 4608, uiQuantity := 32, pData := ADR(flowControl)); linkUpCounter_Request(rClient := client_NetworkSwitch, uiStartItem := 5888, uiQuantity := 32, pData := ADR(linkUpCounter)); txPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8192, uiQuantity := 100, pData := ADR(txPacketCounter1)); txPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8292, uiQuantity := 28, pData := ADR(txPacketCounter2)); rxPacketCounter1_Request(rClient := client_NetworkSwitch, uiStartItem := 8448, uiQuantity := 100, pData := ADR(rxPacketCounter1)); rxPacketCounter2_Request(rClient := client_NetworkSwitch, uiStartItem := 8548, uiQuantity := 28, pData := ADR(rxPacketCounter2)); txErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8704, uiQuantity := 64, pData := ADR(txErrors)); rxErrors_Request(rClient := client_NetworkSwitch, uiStartItem := 8960, uiQuantity := 64, pData := ADR(rxErrors)); // Trigger all client requests initially FOR clientRequestsCnt := 0 TO (SIZEOF(clientRequests)/SIZEOF(clientRequests[0]))-1 DO pClientRequest := clientRequests[clientRequestsCnt]; pClientRequest^.xExecute := TRUE; END_FOR // Prepare sequential trigger / control of client requests. clientRequestsCnt := 0; pClientRequest := clientRequests[clientRequestsCnt]; END_IF // Call the client to do request processing: client_NetworkSwitch(); // Now we trigger client request sequentially ... IF NOT pClientRequest^.xExecute AND NOT pClientRequest^.xDone AND run AND client_NetworkSwitch.xConnected THEN pClientRequest^.xExecute := TRUE; END_IF // .. and check result/error IF pClientRequest^.xExecute AND run AND client_NetworkSwitch.xConnected THEN IF pClientRequest^.xDone THEN // Prepare next trigger of client request (a rising edge of xExecute) pClientRequest^.xExecute := FALSE; IF clientRequestsCnt < SIZEOF(clientRequests)/SIZEOF(clientRequests[0])-1 THEN // next client request clientRequestsCnt := clientRequestsCnt + 1; ELSE clientRequestsIterationCounter := clientRequestsIterationCounter + 1; clientRequestsCnt := 0; END_IF pClientRequest := clientRequests[clientRequestsCnt]; END_IF END_IF I did try a semi-coded way using the IoDrvModbusTCP library, and setting the slave com settings, then 10 commands and 10 requests, then using a TP on xDone as a pause, before triggering another request - this is time the delay is around 120ms - so the device is fine with the speed, just something I am doing wrong in the ModbusFB method I am sure.
Last updated: 2024-04-26
Post by mubeta on Some 'pathetic' errors in SoftMotion program
CODESYS Forge
talk
(Post)
Hello everyone, I have a very simple program for the process, but it's driving me crazy and I can't see the problems I'm left with: Short topological description: Dual Core Berghof controller with softmotion runtime version 3.5.19.30; Two axes with servodrive on canopen bus, clocked distributed from master; Ethercat I/O node; 2 ms ethercat task, 2 ms canopen bus cycle time; I/O objects of the canopen master and canopen drives connected to the ethercat task cycle; Problem 1: Two separate programs each manage their own axis and drive, with separate state machines. A first axis moves primarily in velocity, except having to position itself absolutely at a predetermined point at the end of the job; the second axis, on the other hand, is a paper unwinder that changes, for each job cycle, from actions in absolute, relative, and cam displacement with the master axis. Well, the state machine of both axes was written in such a way as to call running the useful FB and change it on state change in this way: CASE i_stateMachine OF 0: o_Power(Enable := TRUE, bRegulatorOn := FALSE, bDriveStart := FALSE, Axis := o_PaperUnwinderAxis); o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_MoveRel(Execute := FALSE, Axis := o_PaperUnwinderAxis); o_CamSelect(Execute := FALSE, Master := o_MachineAxis, Slave := o_PaperUnwinderAxis, CamTable := cam_PaperUnwinder); o_CamIn(Execute := FALSE, Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Execute := FALSE, Slave := o_PaperUnwinderAxis); o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis); IF ... THEN i_StateMachine := 10; END_IF; 10: o_Power( Enable := TRUE, bRegulatorOn := TRUE, bDriveStart := TRUE, Axis := o_PaperUnwinderAxis ); IF o_Power.Status THEN i_StateMachine := 20; END_IF; 20: (* Avanzamento carta *) o_MoveAbs( Execute := TRUE, Position := o_Somewhere, Velocity := 25.0, Acceleration := 3666.7, Deceleration := 3666.7, Jerk := 48000.0, Direction := MC_DIRECTION.positive, Axis := o_PaperUnwinderAxis ); IF o_MoveAbs.Done THEN o_MoveAbs(Execute := FALSE, Axis := o_PaperUnwinderAxis); i_StateMachine := 30; END_IF 30: d_HomingPosition := ...; o_SetPosition( Execute := TRUE, Position := d_HomingPosition, Mode := FALSE, Axis := o_PaperUnwinderAxis ); (* ... *) IF o_SetPosition.Done = TRUE THEN o_SetPosition(Execute := FALSE, Axis := o_PaperUnwinderAxis ); o_LogServer.Append(sMessage := '...', lscClass := LOGSERVER_CLASS.ALWAYS, sdt := o_CommonsMgrData.systime.sdtLocal); i_StateMachine := 40; END_IF; 50: ... The code above is a sketchy example of what I wanted to write. But it gives me a spot problem: in some, the state change results in a drive error, which is unrecoverable except with a reinitialization via SM3_ReinitDrive(). Things are improved a little if in the program I always run the call of all softmotion blocks in this way: o_Power(Axis := o_PaperUnwinderAxis); o_Jog(Axis := o_PaperUnwinderAxis); o_Halt(Axis := o_PaperUnwinderAxis); o_MoveAbs(Axis := o_PaperUnwinderAxis); o_MoveRel(Axis := o_PaperUnwinderAxis); o_CamIn(Master := MachineEncoder, Slave := o_PaperUnwinderAxis); o_CamOut(Slave := o_PaperUnwinderAxis); If I don't execute all the calls of all the motion FBs used, when exchanging machine state often (but not always), the axis goes into error with event id THE_FB_WASNT_CALL... Done a little diagnostics it seems that the FBs return the bDone, before they are completely terminated. I tried doing the machine state exchange not with the bDone bit of the FBs, but with the 'standstill' state of the axis. It didn't seem to change anything. Problem 2: During the use SM3_ReinitDrive() I get the erro in the log: "NetID 0: SDO read error for object 16#607C..." Assuming that the device involved it's one of the two servodrive, (no others device are present in the network), I don't found any object 0x607C in the 'possible object list in/out' of the two drive, and I don't understand where this object can be listed. So any ideas and suggestions regarding these two issues will be very, very welcome. If you need the source project, I am willing to send it.
Last updated: 2024-07-17
Post by manuknecht on Opening a Dialog on a specific Client from ST
CODESYS Forge
talk
(Post)
I managed to find a solution that seems to work reliably. As the VU.Globals.CurrentClient-filter accesses the CURRENTCLIENTID or at least a similar, internal variable it can only be used if called from a certain client (e.g. from a button in a visualization). My solution works by implementing a new client filter that compares the client ID of all clients to the ID of the last client that was used. The variable containing the data of the last client is defined as: G_LastClient : VU.IVisualizationClient; // Copy of last client that detected click This last client is then updated every time a button is pressed using the Execute ST-Code input configuration of the button: G_LastClient := VU.PublicVariables.Clients.Current; Next, I created a function block that implements the client filter interface as so: FUNCTION_BLOCK FB_LastClientFilter IMPLEMENTS VU.IVisualizationClientFilter VAR_INPUT END_VAR VAR_OUTPUT END_VAR VAR END_VAR Then i added a method to the FB called IsAccepted which is used to filter out the client. When creating the method, it should automatically be filled with the according variable declaration, as it is defined in the interface: (* For every client can be desided, if it is accepted. ``TRUE``: Client is accepted*) METHOD IsAccepted : BOOL VAR_INPUT (* The client, to check*) itfClient : VU.IVisualizationClient; END_VAR Now the client can be compared to the last used client as such: // check if clientID corresponds to clientID of last recorderd client IF itfCLient.ClientId = G_LastClient.ClientId THEN IsAccepted := TRUE; ELSE IsAccepted := FALSE; END_IF To make use of this custom client filter, initialize a variable with the client filter: LastClient : FB_LastClientFilter; // Client filter to find last used client Then use this client filter when opening or closing a dialog from ST: fbOpenMyDialog(itfClientFilter:=LastClient,xExecute:=TRUE,sDialogName:='VIS_MyDialog_DLG');
Last updated: 2023-09-27
Post by testlogic on Sending Sequential Modbus TCP Packets
CODESYS Forge
talk
(Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06
Post by tk096 on High Cycle Times for SoftMotion_PlanningTask when using AxisGroup
CODESYS Forge
talk
(Post)
Hi, under this circumstances the performance of a Raspberry Pi 4 should be sufficient to run a Softmotion robotics application. A closer look at the project would be required. Maybe you could contact the codesys support? Usually it is recommended to run the planning task cyclically every 2ms with task priority of 0 on a dedicated core. In the task configuration you can have a look at the average and maximum execution time of the planning task. You could use the function block SMC_TuneCPKernel (https://content.helpme-codesys.com/en/libs/SM3_Robotics/Current/SM3_Robotics/POUs/AdministrativeConfiguration/Computation/SMC_TuneCPKernel.html) to define suitable values for the parameters 'fSyncBufferDuration' and 'fPlanningInterval'. However, as previously mentioned, the performance of a Raspberry Pi 4 with realtime patch should be sufficient. The 'fPlanningInterval' parameter specifies the maximum planning step width in seconds. The cycle time of the planning task should not permanently exceed this value. A higher value reduces the computational effort, but can lead to a violation or no full utilization of the set limit values for velocity, acceleration and jerk. From a starting value of 0.016 seconds, the value should be increased gradually until the performance is acceptable. The parameter 'fSyncBufferDuration' specifies the size (in seconds) of the buffer between the planning and fieldbus task. The cycle time of the planning task must not exceed this value at peak times (this will lead to the error SMC_CP_QUEUE_UNDERRUN). A higher value can compensate for peaks in the cycle time of the planning task. At the same time, however, this also increases the latency for executing interrupts and aborting movements.
Last updated: 2024-03-22
Post by youness on No source code available (cip object)
CODESYS Forge
talk
(Post)
Hi yotaro, hope your problem was resolved. I had the same, but with an other library title. This exception is not detected during compilation, but rather at a given position in the program (when switching to a given visualization). Although the exception is generated at this point, it does not involve the visualization in question. This error is due to one of 3 reasons: 1) A division by zero somewhere: The program is able to detect divisions by zero at compile time. But in the case of a variable, which takes a valid value at init and changes to 0 at a later stage. 2) An invalid pointer: (either because it has a value of 0, or because it points outside the memory reserved for the program) is being dereferenced. Locate any pointers or interfaces you have in the code and check them - you should also be wary of mixing inline modifications and pointers. 3) Array overflow: Generally when a processing operation is executed outside the array's definition range. Example: a write loop with n iterations is executed on an array of dimmension n-1. On the other hand, the error message may not appear. In the latter case, the error may have fatal consequences, as the overflow has induced writing to potentially forbidden memory areas. This problem can be explained by the fact that it's not always the adjacent memory areas of PLC_PRG that are overwritten, but the memory areas that are randomly allocated to the array during compilation. In this case, however, there is no entry in the log, so you need to integrate the "Implicit Check function", which checks the line of code generating the error. To integrate this functions, click on Application --> POU for implicit controls Regards,
Last updated: 2024-07-16
Post by maldus512 on How to adapt Codesys Control SL to custom board
CODESYS Forge
talk
(Post)
Hello everyone, I have been given the task to develop I/O drivers for a custom made, Linux based board to allow for Codesys applications to run and control the hardware. I have successfully installed Codesys Control SL for ARM/Linux and tested it with a simple demo application. Now I should start interfacing the runtime to the actual hardware; I should be able to interact with 2 RS485 serial ports, a few GPIOs and an I2C port, all of which already have the corresponding /dev/ interface in the Linux system. I am having trouble understanding how it should be approached. I have found sporadic references that fail to lead to a really comprehensive documentation. For example: The store page (https://store.codesys.com/en/codesys-control-for-linux-arm-sl-1.html#options) mentions a "runtime package" that should allow "Integration of existing C code" and "Usage of local I/Os", which seems exactly what I need to interact with custom peripherals. I have found no further reference to Codesys-C interpop. The Codesys Help page for the runtime package has a page on the "Development of Drivers" (https://content.helpme-codesys.com/en/CODESYS%20Control/rtsllinuxrbpdriverdevelopment.html) that suggests to either "Implement a function block" or "Implement I/O drivers". Those in turn lead to this page (https://forge.codesys.com/drv/io-drivers/doc/Generic/) which describes briefly an XML schema to describe new devices; unfortunately, it doesn't mention what to do with such a description (i.e. how does the runtime know about it) or how it is in any way connected to the actual hardware. Could anyone give me some pointers? I should also mention I have no prior experience with Codesys, so maybe I'm missing an obvious answer.
Last updated: 2024-08-09
Post by solidlogicguy on Little endian to Float from Modbus RTU
CODESYS Forge
talk
(Post)
Hello, I got a device from which I require to read values from I am using a WAGO PLC 750-8212 and I am communicating through Modbus Master FUNCTION BLOCK from library WagoAppPLCModbus in Codesys 3.5 to this device. I already receive data from the device that is a CVM to monitor voltage from a fuel cell. The technical support of the company that makes these devices says that the data is sent in little endian form. And I want to convert it to a float value. The tech support sent me the next instructions of how to do it but I am new using codesys, so any advice or help I will really appreciate so much. Message from tech support: The process is complicated, better to do it with already implemented library in the language/program you use. Basically the process should be next: To convert the two Modbus registers containing parts of a 32-bit float in little-endian byte order to a floating-point number using mathematical operations, you first need to combine the two 16-bit integers (assuming reg1 is the lower word and reg2 is the higher word) and then interpret the result according to the IEEE 754 standard. Given: - Register 192 (reg1) = 4096 - Register 193 (reg2) = 14884 Step 1: Combine the two registers. Since we are dealing with little-endian byte order, reg2 is the high word, and reg1 is the low word: combined = reg2 * 2^16 + reg1 combined = 14884 * 65536 + 4096 combined = 975175680 + 4096 combined = 975179776 Step 2: Convert the combined value to binary: combined_binary = '1110101101011100000000000000000' Step 3: Split the binary into IEEE 754 components: Sign bit (1 bit): 0 Exponent (8 bits): 11101011 Mantissa (23 bits): 01011100000000000000000 Step 4: Convert the binary exponent to decimal and subtract the bias (127 for 32-bit floats): exponent = int('11101011', 2) - 127 exponent = 235 - 127 exponent = 108 Step 5: Calculate the mantissa as a fraction: The mantissa in IEEE 754 format is the fractional part after the leading 1 (which is implicit). Therefore, we need to convert the binary mantissa to decimal and add the implicit leading 1: mantissa_fractional = 1 + int('01011100000000000000000', 2) / 2^23 mantissa_fractional = 1 + 18688 / 8388608 mantissa_fractional = 1 + 0.002227783203125 mantissa_fractional β 1.002227783203125 Step 6: Combine the sign, exponent, and mantissa to get the float value: float_value = (-1)^0 * mantissa_fractional * 2^exponent float_value = 1 * 1.002227783203125 * 2^108 Because the exponent is quite large, the resulting float value is a very large number.
Last updated: 2023-12-15
Post by rkohser on Scripted Git clone / checkout being blocked by "Project Environment" popup
CODESYS Forge
talk
(Post)
Hi, I am trying to build a CI/CD pipeline around our codesys projects. The only entry point if the git url and branch, as we do not put our project file under source control, so we needed to find a way to git clone from the python scripting engine. This is currently how we do this : system.commands["Git", "Clone"].execute( "ProjectLocation=" + project_dir, "ProjectName=" + project_file_name, "RemoteUrl=" + project_git_remote_url, "GitProjectStoragePath=" + project_git_local_dir, ) system.commands["Git", "Checkout", "Branch"].execute( "PrimaryProjectHandle=0", "BranchName=origin/" + project_git_branch ) This works fine, except that, depending on the environment and the project, the "Project Environment" popup gets displayed to suggest for some updates, and waits for a user interaction, even with the "--noUI" flag injected as parameter. I investigated the VersionUpdateFlags, but the problem is that the git clone is an atomic operation that clones and directly opens the generated project without the possibility to inject any updateFlags argument (only used in the ScripProjects.open() function. I also tried to simulate some keyboard events acknowledge the window from script but I did not find the right location for the SendKeys statement, I think before the git clone call is too early and after is too late. So I am wondering if there would be some other way to do that. Is there some more proper scripting api for the git add on ? Is there a global configuration of the VersionUpdateFlags that would allow the popup to be disabled outside from any project context ? Is there some way to automatically acknowledge this kind of messages in a "--noUI" mode ? What do you suggest ? Thanks for your help, Roland Edit : I managed to solve my problem by following these steps in my pipeline : - create a template of a project and opt file preconfigured not to open the popup - open this project - initialize an empty git repo - add the remote, fetch and checkout the needed branch -> no popup is displayed, hourra Edit2 : The initial question was raised on a CODESYS V3.5 SP18 Patch 2 profile. Since CODESYS 3.5.19.30 a scripting API is available for Codesys Git that allows cloning a project with the support of VersionUpdateFlags https://content.helpme-codesys.com/en/CODESYS%20Git/_git_using_scripting.html
Last updated: 2024-01-19
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.