Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string
CODESYS Forge
talk
(Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses “$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29
Post by jzhvymetal77 on Special Chars in Visualizationfor QR code string
CODESYS Forge
talk
(Post)
In Visualization, is there any way to make special characters in a string display properly in a Text object? I wrote a function block to create QR codes at runtime. My code uses “$DB,” which in ASCII should render as a solid block. The code works, but to display it in Visualization I had to create multiple rectangles with visibility bound to a BOOL array. That works, but since each BOOL must be exposed as a separate variable, it consumes most of the available monitoring resources. See Attached image.
Last updated: 2025-09-29
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15
Post by dominggus on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
I still have the same problem even when updating to CODESYS Recipes 4.3.0.0. My scenario: I'm trying to save/load an array of structs using the Visu: - Execute Command > "SaveRecipeAs" works properly - Execute Command > "LoadWriteRecipe" works not entirely: the structs of array[6] and array[7] should have been empty but were duplicates of array[4] and array[5]... the struct contains 26 variables and the array's length is 30.. Maybe there is a upper limit on recipe variable count?
Last updated: 2024-03-02
Post by stuartjr on Disabling forcing of specific variables
CODESYS Forge
talk
(Post)
OK.. so maybe I miss understood for how the forcing order works. It seems that the force list is applied at the beginning of every task call (I'm assuming this based on what I am seeing). If I force my variable FALSE and then write it TRUE in a task, then it stays TRUE for that task, but then in the next task it will go back to FALSE.
Last updated: 2024-03-15
Post by wollvieh on Problem while updating to new runtime 4.11.0.0
CODESYS Forge
talk
(Post)
okay, no ideas. So i made a new fresh image for the raspberry, so far,so good. Licensing the new image was no problem. And, after having trouble while read write files on the raspberry pi, i found the solution for these file operations with the Variable ForceIecFilePath in the CODESYSControl.cfg file. Some people had that issue discussed in that thread : https://forge.codesys.com/forge/talk/Deutsch/thread/d2df08e587/
Last updated: 2024-03-18
Post by noahpiskor on Configuration dialog screen with a Frame
CODESYS Forge
talk
(Post)
Hello, I'm trying to configurate a frame. My goal is to have a frame with the symbol of a component. When I press the symbol a dialog screen of my choosing comes up. What variable should be used in the frame configuration, that I can put in the input configuration of my symbol. so that I can chose which dialog screen comes up on my multiply instances of this frame. Kind regards. Noah Piskor CODESYS V3.5 SP19 Patch 6
Last updated: 2024-04-02
Post by dkugler on Alarm State Icon
CODESYS Forge
talk
(Post)
thank you for pointing me to this "bug"!! I haven't recognized, the bit is reset after the first alarm is gone. I use this only for warnings, so it's not a drama, but was not correct in the past. I solved it now simply stupid by counting up a variable every time an alarm appears and decreasing it if an alarm is gone. The "warning lamp" is activated by checking the counter is > 0 The nice side effect, i'm able to show the number of active alarms in the state line now.
Last updated: 2024-04-24
Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by talhaali on Create an alarm list without use of Alarm config
CODESYS Forge
talk
(Post)
Hi, I am trying to access active alarms in code(As alarm count variable updates only when we go to to alarm table frame in visualization). I wrote following code but it is not working: VAR iCountActiveAlarms : INT; parritfActiveAlarms : POINTER TO ARRAY[0..0] OF IAlarm; itfAlarmManagerClientAll : IAlarmManagerClient; END_VAR AlarmManager.g_AlarmHandler.GetActiveAlarms( itfAlarmManagerClient :=itfAlarmManagerClientAll, iCountActiveAlarms => iCountActiveAlarms, parritfActiveAlarms => parritfActiveAlarms); The Value is always 0. Please help.
Last updated: 2024-06-06
Post by nano on How to access to variable value through symbolic string name
CODESYS Forge
talk
(Post)
i know, this is the reason for us either. PLC-Handler is to big, and only available with additional Contracts/Costs. OPC-UA is to slow for us. As described, there is a solution available, but im not allowed to post them here. i would prefer you send a message at codesys store by "have a question" or similar called. Not sure. Or, if an Codesys-Official Member allows to share that informations, i can give you the right hints.
Last updated: 2024-06-15
Post by sajid on NMEA Serial data read in Control win v3 x64
CODESYS Forge
talk
(Post)
I am using the SerialCom example program from the CODESYS website to read NMEA strings in CODESYS Control Win V3 x64 through a serial-to-USB converter. However, I occasionally receive only partial data or encounter errors in the received string. A screenshot of expected NMEA string attached for reference. Could you please advise on how to ensure the full NMEA string is received consistently? Error in strRead variable is <value of="" the="" expression="" cannot="" be="" retrieved=""></value>
Last updated: 2025-10-16
Post by sajid on NMEA Serial data read in Control win v3 x64
CODESYS Forge
talk
(Post)
I am using the SerialCom example program from the CODESYS website to read NMEA strings in CODESYS Control Win V3 x64 through a serial-to-USB converter. However, I occasionally receive only partial data or encounter errors in the received string. A screenshot of expected NMEA string attached for reference. Could you please advise on how to ensure the full NMEA string is received consistently? Error in strRead variable is <value of="" the="" expression="" cannot="" be="" retrieved=""></value>
Last updated: 2025-10-16
Post by larboardinner on Alarm Table Issues
CODESYS Forge
talk
(Post)
Variable for Selected Alarm ID only updates when the visualization is actually configured to send the alarm’s ID back to the control. On some devices/visualization profiles this isn’t enabled by default. Make sure your Alarm Table element has “Send Selected Alarm ID” activated in the visualization properties. you could check this example: https://store.codesys.com/alarm-manager.html Geometry Dash Lite If that option isn’t available in your version, then unfortunately the “Selected Alarm Group” is the only one that updates reliably in older 3.5.x builds.
Last updated: 2025-11-17
Post by riccardo on VisuElems.CurrentUserGroupId is not stable
CODESYS Forge
talk
(Post)
GoodMorning everyone. I have a system that, in case of alarm, have to block. When the operator logs in must have to acknoledge the alarm and should operate in the system freely. To perform this I detect the logged User by (VisuElems.CurrentUserGroupID <> 0) with a similar code to the the following: PROGRAM AlarmMngt VAR alarm : BOOL:= FALSE; Ack : BOOL:= TRUE; PushBottonOpening : BOOL:= FALSE; Valve : BOOL := FALSE; Flag: BOOL := FALSE; END_VAR IF alarm AND Ack AND (NOT Flag) THEN valve := FALSE; PushBottonOpening := FALSE; Ack := FALSE flag := TRUE; ELSIF (NOT alarm) AND Ack THEN flag := FALSE; END_IF (* if the system is in alarm but there is a logged operator that acknowledge the alarm the system allows the valve opening.*) IF (VisuElems.CurrentUserGroupID <> 0) AND Ack AND Alarm AND PushBottonOpening THEN Valve := TRUE; ELSIF (VisuElems.CurrentUserGroupID = 0) AND Alarm THEN valve := FALSE; END_IF The problem I have is in the last 5 lines of the code: Even if there is a logged in user, the GroupID variable is subjected to a refresh that cyclically set for an instant it to 0 and this close the valve making difficult to the user to work Now I solved it creating a time hysteresys cycle but it is not a good solution. Someone is able to explane me why the GroupID variable is sobjected to this refresh and how to stabilize to avoiding it? Thank you in advance, Riccardo
Last updated: 2023-11-10
Post by trusty-squire on Confused by dwIpoTime input for SMC_Interpolator
CODESYS Forge
talk
(Post)
Hi, Learning Codesys CNC, and I am confused by the dwIpoTime parameter. I have a basic demo application, using SMC_Interpolator feeding into SMC_TRAFO_Gantry2Tool2, which then sets the position of the x/y SM_Drive_Virtual axis. I also have a C axis which revolves the tool, which is controlled using a simple tangential angle calculation SMC_CalcDirectionFromVector. The GCode I'm using has feed/accel set at 500. The axis configuration limits are well above that (2000). What's strange is that, when I run the simulation, the feed speed changes drastically when I update the variable dwIpoTime. The larger the number, the faster it moves. What's going on here? The documentation only says "This variable has to be set for each call. It represents the cycle time in μsec." Why does it change the feed speed I'm seeing the in simulation? What is a good number to use? The example I was looking at set it at 5000. Screenshot attached.
Last updated: 2024-07-18
Post by gseidel on AXIS_REF_SM3 Error Codes?
CODESYS Forge
talk
(Post)
Hi SLUCodesys, dwErrorId is a drive specific error number. The drive documentation should be consulted to interpret it. (Note that you should use MC_ReadAxisError to read this error, see https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/MC_ReadAxisError.html. Accessing the internal variable will result in outdated values if the acis error is not mapped by PDO and is not recommended in general.) uiDriveInterfaceError holds errors of the SoftMotion driver for the drive. It is also an internal variable, not intended for direct access. It is intended for logging, the PLC log will contain the drive interface error, consisting of this number and an error text. My recommendation for handling axis errors in the CODESYS application: 1) Use MC_ReadStatus on the axis to find out whether it is in state Errorstop 2) If in Errorstop, there are two possibilities: an error reported by the drive (MC_ReadAxisError) or an error of the SoftMotion function blocks (output MC_ReadStatus.FBErrorOccured). 3) If there is no drive error, you can use SMC_ReadFBError https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/FBError/SMC_ReadFBError.html Best regards, Georg
Last updated: 2025-09-24
Post by e13740e on Parameterized Property syntax for array element processing
CODESYS Forge
talk
(Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT <index_name> : <index_type>; // One or more index parameters are declared here END_VAR</index_type></index_name></data_type></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> GET Code that uses <index_name> to return a value END_GET</index_name> SET Code that uses <index_name> and the implicit variable <property_name> to write a value END_SET</property_name></index_name> END_PROPERTY
Last updated: 2025-10-09
Post by e13740e on Parameterized Property syntax for array element processing
CODESYS Forge
talk
(Post)
Hello. I'm trying to create a Parameterized Property(CDS V3.5 SP21) to avoid copy-pasting code for processing array elements. I can't seem to get any result. Perhaps I am making a mistake with the syntax. None of the declaration options below are accepted by the compiler. If you know and use them (Parameterized Properties) in your work, please let me know. Thank you in advance. Option 1: PROPERTY <property_name> : <data_type> VAR_INPUT // One or more index parameters are declared here <index_name> : <index_type>; END_VAR</index_type></index_name></data_type></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY Option 2: PROPERTY <property_name> (<index_name> : <index_type>) : <data_type></data_type></index_type></index_name></property_name> // Accessor for reading GET // Code that uses <Index_Name> to return a value END_GET // Accessor for writing SET // Code that uses <Index_Name> and // the implicit variable <Property_Name> to write a value END_SET END_PROPERTY
Last updated: 2025-10-09
Post by phoward131 on Alarm State Icon
CODESYS Forge
talk
(Post)
I am trying to create an icon on an overview screen that depicts if an alarm group has active alarms, active acknowledged alarms, or inactive unacknowledged alarms (waiting for confirmation). I've attempted to set up Notification Actions in the Alarm Class to set variables based on state changes but have been unable to find a clean and effective way to do this. Because an action on any alarm will trigger the variable to be set as instructed, I'm struggling to find a way to configure it for what I need (ie if two alarms activate, then one deactivates, the variable for indicating an alarm is active would be cleared after the single deactivation). I've been pointed toward the Alarm Manager example project but I'm finding it too complicated to understand how to implement it in my own project. Has anyone come up with another good way to indicate the states of alarms or a simpler usage of the Alarm Manager functions?
Last updated: 2024-04-23
Post by bertus on Can't get SMC_SmoothPath to work
CODESYS Forge
talk
(Post)
Hi Georg, thanks for your time. What is the value of D_ANGLE_TOL? It is set to 0.01. Do you need the assignment bAbort := NOT bDecoder? Does it help to leave it out? This seems to make no difference. Any errors (e.g. SMC_SmoothPath.Error/ErrorID) or PLC log messages? No errors or log messages. What if you comment out SMC_SmoothMerge and SMC_LimtiDynamics, is corner smoothing still not working? Indeed. Is bDecode written from a different task (e.g. visu)? Then I would recommend to assign to a local variable (bDecodeLocal := bDecode) and use that for all FBs. Otherwise, FBs might see different values of bDecode in a single cycle, which will cause problems. It is a local variable, written from a state machine inside this program. But there is new information: During some trial and error, I tried skipping "stage 2: merge short linear segments" (SMC_SmoothMerge). And suddenly it rounds the corners, see attached image. Looking a bit closer, I noticed that (with the original program) after a download (cold start?), it in fact did round the corners, but only once. Ever next cycle in which the NC program was executed, the corners where not rounded. Not sure if there is any relation, but SMC_SmoothMerge is also the only FB which has no bAbort input. Perhaps I need to reset it (or any buffers) by other means?
Last updated: 2025-12-18
Post by e13740e on Parameterized Property syntax for array element processing
CODESYS Forge
talk
(Post)
Since parameterized (indexed) properties are not possible, I decided to use architectural approach "Indexing Property Adapter" to achieve the intended goal — avoiding code duplication for validated access to array elements. Essence: Create a Function Block Adapter (FB_PropertyAdapter) that encapsulates the logic for working with a single element of the target array (e.g., with one settings structure). Declare Properties inside the adapter block for accessing each individual field of the data structure. All validation logic is implemented within the Set accessors of these properties. Data Binding via VAR_IN_OUT: The adapter block receives a reference to a specific data element from the global array through its VAR_IN_OUT section, which ensures direct work with the original data without copying. Create an Array of Adapters: In the parent POU (e.g., FB_SettingsManager), an array of these adapter blocks is created — one for each element of the global array that needs to be managed. Initialize Bindings: In a FOR loop, each adapter instance from the array is given a reference to the corresponding data element. Result: This approach allows accessing the data via the index of the adapter array, and then through the property name, which simulates the behavior of an indexed property: MyAdapterArray[Index].MyProperty Thus, the validation and data access logic is written only once inside the adapter block and is then reused multiple times by creating instances of it in an array. This completely solves the problem of code duplication while providing a clean, scalable, and object-oriented architecture compatible with standard CODESYS features. Question closed.
Last updated: 2025-10-19
Post by critcho on WebVisu Numpad dialog - Dialogtitle not accepting string variable
CODESYS Forge
talk
(Post)
I have a WebVisu page which is re-used for multiple types of gas; it displays the alarm thresholds etc. for one gas at a time. I have an array of structures holding the set-points for each of the gasses. I'm trying to change the dialog title for the value input pop-up (VisuDialogs.Numpad). The Dialogtitle is set to Gas_Alarms.HighAlarmActivationLevelDialog, which is a string(50): When the gas type is changed (page first loaded, or prev/next buttons), METHOD Gas_Alarms.Update_Display_Variables is called, to update the strings used for the dialog titles so it shows GasName High Alarm Activation Level (EngineeringUnits), e.g. CO2 High Alarm Activation Level (PPM): HighAlarmActivationLevelDialog := Insert(' High Alarm Activation Level ()', EngineeringUnits, 30); HighAlarmActivationLevelDialog := Insert(HighAlarmActivationLevelDialog, GasName, 0); (That's not where the problem is, I'm just explaining why I'm using a variable dialogue title.) The variables used are definitely strings, but i'm always getting the error: "The type of the dialog title must be either STRING or WSTRING". I've tried moving HighAlarmActivationLevelDialog etc. to the GVL and also changing them to WSTRING, I even tried adding them to the structure array, but I always get the same error. Clearing the dialog title for that element removes the error - so I'm confident it's not a phantom error caused by something else. But I should be able to add these titles, can't just nuke them all to make it work. The MinVal and MaxVal for the Numpad are called from the array, e.g. GVL.Gas_Alarm_Configs[0].ScaledValueMIN, they are not getting an error. I am using array indexes 1 - 5 for the gasses, when I load the form or change gas, I copy the selected index to index 0 of the array, and values from Gas_Alarm_Configs[0].[ALL] are displayed on the page. When they hit save, I copy Gas_Alarm_Configs[0].[ALL] to Gas_Alarm_Configs[CurrentGasIndex].[ALL]. (ALL just means every element, I can't figure out how to display an asterix in this question... :) ) I've searched online for variable title dialog, but not found anything to help. Thanks for your help!
Last updated: 2025-05-29
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14
Post by dandyk on Dynamic Images
CODESYS Forge
talk
(Post)
Hello, I have very similar problem, but it seems that your solution does not work for me. I am using TwinCAT XAE Shell v3.1.4024.55 and TwinCAT Runtime. Sorry for writing here on codesys forge, but since I found the only relevant topic here and since TwinCAT is almost the same with CODESYS in many applications, I chose to write here. I simply need to dynamically update image in visualization based on camera trigger (I am doing a machine vision application). Camera triggers an image, my program processes it (applies thresholding, draws contours etc...) and saves the processed image in the runtime location (the same one you were mentioning). This was done successfully. I need to make it work at runtime, while the program is executing and I need to refresh the image in the visualization each time camera triggers a new image and program processes it. When I create image element in the visualization and define the bitmap ID variable as STRING which contains the image ID defined in the image pool, then it displays the image in the image pool, but does not work at runtime, while the program is executing. I also used the Bitmap Version. I declared it in Global variable list as integer with initial value of 0 and wrote the variable in the bitmap version in the image element in visualization. Each time new image is saved to the runtime location, I wrote a program to increment Bitmap Version by 1. It increments and the image does not update in the visualization, unfortunately. I think that bitmap version is working correctly and deletes the cached image as it is supposed to, but the Image Pool does not update the image ID with the new image... the path to the image is always the same... only the actual image changes with the same file name. Image Pool is not dynamic and cannot refresh the image in the path to the actual one at runtime. How can I refresh the image ID in the image pool at runtime? Bitmap version only deletes cached image and reloads the image from the image ID, but the image ID has the same image, because image pool won't update at runtime. Do you know any solution to this problem?
Last updated: 2024-04-06