Post by jeroenaero on CodeSys Raspberry pi I2C driver not found CODESYS Forge talk (Post)
I don't have a multiplexer so it very weird that it connects with that multiplexer. If i do a I2C scan on the PI terminal, i only get the device addresses 0x48 and 0x51. One for the ADC and one for RTC. I will try again with your libraries
Last updated: 2024-11-12

Post by dkugler on EtherCAT Master: How many error frames till bus error CODESYS Forge talk (Post)
The story behind: I have had a EhterCAT fieldbus system where sometimes error frames occured. I noticed that the master is tolerant for some error frames, but if there are very much error frames the bus goes in error state. Does somebody know the limit of error frames above the bus changes to error state?
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by xabier on Kinematics Robot Delta 2 Axis CODESYS Forge talk (Post)
Hi, I have a customer and this customer design this robot...The customer need move ...I would like if Codesys has this Kinemtaics I attached photo of the robot.(this robot has 2 Axis) I have checked all kinematics has Codesys but not has the same....Someone help me Please?? Thanks XABI
Last updated: 2024-12-11

Post by gorditron on I2C Communication with CODESYS Forge talk (Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag für die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte für den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer für den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer für die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle für das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13

Post by totorovic on Project loses 'Download time' information CODESYS Forge talk (Post)
I continue this topic by myself, I'm very happy with the Codesys support / community ;-) This information (Download time) should be stored in the compileinfo : https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_cmd_load.html But the file is not text-readable (see attached file) so how to solve if download time is empty?
Last updated: 2024-12-19

Post by gseidel on Strange problem with the ‘MC_SetPosition’ function CODESYS Forge talk (Post)
Hi Gustavo, can you reduce the problem to a project that reproduces the issue without the real servo drives? (You could set the servo drives to virtual and strip away as much as possible from the application.) If you can attach a project, we will have a look. Best regards, Georg
Last updated: 2025-01-10

Post by trusty-squire on Help with __SYSTEM.VAR_INFO CODESYS Forge talk (Post)
Not knowing exactly what you want to accomplish, you can try to use VAR_INPUT MyVar: POINTER TO BOOL; END_VAR MyVar contains the address of your referenced variable, and MyVar^ dereferences it allowing you to access the value. If this doesn't meet your needs, could you add more detail on what you are trying to accomplish?
Last updated: 2025-01-26

Post by gatto on Removing a symbol from the IEC Symbols Editor grid CODESYS Forge talk (Post)
Hi, I've never used Communication Manager, but I tried it and I saw that I can drag tags from left to right. If I click on a line on the right, it turns light blue. By pressing the DEL or CANC key (It depends on your keyboard language) I can delete the line
Last updated: 2025-02-12

Post by clarenced on Multiple applications on one device sharing variables. CODESYS Forge talk (Post)
Sounds feasible, but how would I create this object so that both applications would use the same instance of it. If this did work, it's still not really the solution I am looking for as it would mean mapping every variable I want to use on the hmi through this object vs I was hopping all the GVL variables would be available.
Last updated: 2025-02-20

Post by cellohorst on File Creation Issue CODESYS Forge talk (Post)
Nope! The file path is $$PlcLogic$$ and NOT $$PLCLogic$$. Otherwise a new folder ('PLCLogic') is created (at least with a linux rt - like raspberry or compute module) with the new file in it if you open the file with eFileMode := FILE.MODE.MRDWR. That is a bad bug that I'll report right after this comment.
Last updated: 2025-03-03

Post by lockupversus on High resolution displays with 150% scaling causes CodeSys IDE to be blurry CODESYS Forge talk (Post)
What version of Windows are you using? If you are using older Windows, just upgrade to the latest version and use CodeSys IDE as usual. Nothing will happen. Some more complex options below. https://forge.codesys.com/prj/codesys-example/element-collect/home/Home/ https://store.codesys.com/en/mysql-library-sl.html Doodle Baseball
Last updated: 2025-03-05

Post by tvm on VisuFbFrameBase.SetInputPositionData: The element id for the input position cannot be determined CODESYS Forge talk (Post)
This came up again today, so I'll post the fix for future reference. Happens with Schneider Machine Expert 2.2 and M262 controllers. Add this bit of code to a program called from the visu task //disable "VisuFbFrameBase.SetInputPositionData" log messages, which fill up the logs IF VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.GetListenerCount() > 0 THEN VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.RemoveValueChangedListener(VisuElems.Private_Visu_Globals.g_ValueChangedListenerManager.listenerForOnValueChanged); END_IF
Last updated: 2025-03-06

Post by gseidel on Dynamic limits invaild CODESYS Forge talk (Post)
Hi jbu0105, which error doe you get, exactly? Is it error 11008, SMC_MOVE_INVALID_DYNAMICS? (It might help if you check the "Log" tab in the PLC device and copy the exact error.) Please double-check whether the inputs Velocity, Acceleration, Deceleration, and Jerk of MC_MoveCircularAbsolute have correct (positive) values. Best regards, Georg
Last updated: 2025-04-07

Post by respl on Anyone Ever use CAN with Kollmorgen S600 Drive CODESYS Forge talk (Post)
Dear eschwellinger, Can you please share which library to use. Also if possible please share backup it really help us. On Codesys Store there are many ( CoDeSys Softmotion) option available. Please guide me to choose right product which has driver for servostar 600 as mention above. Regards, Rahul Sayre service.retrofilm@gmail.com +91-9607140005
Last updated: 2025-04-15

Post by jbu0105 on Setpoints Delta robot CODESYS Forge talk (Post)
Hello, I am working on a delta robot. Now was i wondering if anyone knows whats the best way to program the different setpoints for the delta Robot. I would like to use the functions MC_MoveLinearAbsolute and the function MC_MoveCircularAbsolute with the transition on this function. Can anyone help me with al small setup?
Last updated: 2025-04-16

Post by jbu0105 on Setpoints Delta robot CODESYS Forge talk (Post)
Hello, I am working on a delta robot. Now was i wondering if anyone knows whats the best way to program the different setpoints for the delta Robot. I would like to use the functions MC_MoveLinearAbsolute and the function MC_MoveCircularAbsolute with the transition on this function. Can anyone help me with al small setup?
Last updated: 2025-04-16

Post by pafarrell on EtherCAT quick start for advanced programmers CODESYS Forge talk (Post)
It would be great if there was a thread that had some quick-start links for basic how-to. But one that advanced programmers can jump into. I found this video playlist by SoftMotion-Black, which was very, very helpful: https://www.youtube.com/playlist?list=PLkc8m2OD0r9xJyfTiCBb1vuU_d2yBhjZ_ This person has some other great vids like creating your own custom library, which is awesome for OEMS.
Last updated: 2025-05-14

Post by naduley on Multiple Branches CODESYS Forge talk (Post)
I am trying to create multiple branches in my project and I keep getting gaps in the ladder logic "wiring". I'm not sure if this is a graphical error or something else but every thing I've tried to do to correct it does not work. Has anyone else run into this or know how to correct it?
Last updated: 2025-06-04

Post by arwie on Use MC_Home without enabling the drive for homing method 35 CODESYS Forge talk (Post)
This is a homing routine which is controlled by setting mode of operation and started by setting a bit in the control word. If MC_Home is not usable for this homing method then I need to implement the same functionality. But how?
Last updated: 2025-06-25

Post by felixm on Unable to select VisuDialogs.Numpad in Open Dialog input configuration CODESYS Forge talk (Post)
I'm trying to open the VisuDialogs.Numpad dialog to enter a new temperature setpoint on one of my VISU screens. For some reason, the numpad dialog does not appear as an option in the Open Dialog dropdown in my input configuration. I'm very new to CODESYS, so sorry if this is a simple fix/known item XD.
Last updated: 2 days ago

Post by arundara on Variable Sync Issue In Soft Plc Redundancy CODESYS Forge talk (Post)
Hello, I was trying to create a redundancy POC for our application where we read data from few modbus tcp devices. As there is a limitaion that modbus tcp device support only for single master device, we wanted to test how the variable sync happens in redundancy mode. For that i have used the redundancy sample code added a variable "b" under a condition. What i observed was while active controller is running, if passive controller is powerup, passive controller is able to sync all the data configured for redundacny. But after that the variable data which resided under a condition is not synching from active to passive controller. I have attached the image where i have highlighter the variable. Can some help me to understand how redundacny work in codesys soft plc and if there is a solution to sync variable which are under condition, please explain the same or suggestion to achieve the same. Hardware - Raspberry Pi (2 qty) Redundancy licence used - yes in both controllers. Codesys runtime - 4.9.0.0 Codesys software version - V3.5 SP19 if i have posted this question in wrong section, please do let me know in whcih section i have to post this question.
Last updated: 2023-12-01

Post by open on How to create a stopwatch? CODESYS Forge talk (Post)
Hi @ph0010421, I tried the program the TimeTaken is calculated when stop is triggered. I want the TimeTaken to be continuously calculated and counting when a BOOL variable is true. I tried to program this way: Declaration: PROGRAM PLC_PRG VAR bStartStop: BOOL := FALSE; // Start/Stop button bReset: BOOL := FALSE; // Reset button bRunning: BOOL := FALSE; // Flag indicating whether the stopwatch is running tStartTime: TIME; // Variable to store the start time tElapsedTime: TIME; // Variable to store the elapsed time END_VAR Implementation: // Main program logic IF bReset THEN // Reset button pressed, reset the stopwatch bRunning := FALSE; tElapsedTime := T#0s; ELSIF bStartStop THEN // Start/Stop button pressed, toggle the running state IF bRunning THEN // Stop the stopwatch bRunning := FALSE; ELSE // Start the stopwatch bRunning := TRUE; tStartTime := tElapsedTime; END_IF; END_IF // Update the elapsed time when the stopwatch is running IF bRunning THEN tElapsedTime := tElapsedTime + T#1s; // Adjust the time increment as needed END_IF However counting of the seconds is not accurate. I tried changing the main task cycle time interval to 1000ms. The counting of seconds become slower. (see attached) Please help
Last updated: 2023-12-08

Post by ph0010421 on How to create a stopwatch? CODESYS Forge talk (Post)
Do you need an 'hours-run' counter? And 1 second resolution is ok? I think you're over-thinking it. (The task time needs to be < 1second) Have a look at the LAD... Then, the time in seconds can be made into hh:mm:ss with this FUNction Declarations: FUNCTION funSecondsToStringTime: string VAR_INPUT InSeconds: UDINT; END_VAR VAR AsString: STRING; Minutes: UDINT; Hours: UDINT; Seconds: UDINT; MinutesAsString: STRING(2); HoursAsString: STRING(2); SecondsAsString: STRING(2); END_VAR and the code: Hours := InSeconds / 60 / 60; //Derive hours Minutes := (InSeconds - (Hours * 60 * 60)) / 60; //Derive minutes Seconds := InSeconds - ((Hours * 60 * 60) + (Minutes * 60));//Derive seconds HoursAsString := UDINT_TO_STRING(Hours); MinutesAsString := UDINT_TO_STRING(Minutes); SecondsAsString := UDINT_TO_STRING(Seconds); IF LEN(HoursAsString) = 1 THEN HoursAsString := CONCAT('0',HoursAsString); END_IF; IF LEN(MinutesAsString) = 1 THEN MinutesAsString := CONCAT('0',MinutesAsString); END_IF; IF LEN(SecondsAsString) = 1 THEN SecondsAsString := CONCAT('0',SecondsAsString); END_IF; AsString := CONCAT(HoursAsString, ':'); //assemble string AsString := CONCAT(AsString,MinutesAsString); AsString := CONCAT(AsString,':'); AsString := CONCAT(AsString, SecondsAsString); funSecondsToStringTime := AsString;
Last updated: 2023-12-08