Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by mariacugnier on Bug Device login
CODESYS Forge
talk
(Post)
I'm having the same issue.I think it may be something related to the device adress that changes depending on the network i'm using, but now i don't have access to the one i used while setting my user. Did you find any solution for this?
Last updated: 2024-06-20
Post by davidbo on What is the prerequisites for a Raspberry Pi to work with SysSockSetIpAddressAndNetMask()
CODESYS Forge
talk
(Post)
I have now and it works. I had the idea that it had something to do with codesyscontrol.cfg, but where can I find a description of all the things you can set in codesyscontrol.cfg and its syntax?
Last updated: 2025-11-12
Post by micik on Error, visualisation property handling, VISU_USEPROPERTYINFO
CODESYS Forge
talk
(Post)
@davidking, can you be more specific about where exactly "Compiler Defines" is located. I'm using Codesys v3.5 SP21 Patch2 and cannot find this Compiler Defines option. In the menu Project -> Project Settings there are Compiler options and Compiler warnings, but that is not it.
Last updated: 2025-11-26
Post by mtorell on Safe Editor in codesys v3.5sp21p30
CODESYS Forge
talk
(Post)
How do I negate an output signal from an OR gate. I have tried right click to no avail and I cannot find an propriate NEGATE box? I want to save the output from the block to an inverted variable.
Last updated: 2026-03-12
Post by away on Visualization stops responding
CODESYS Forge
talk
(Post)
Hi @spiritcore, Did you find a resolution to this? I'm running into a similar issue using TargetVisu when a user uses the login. It only happens sometimes, and when it does the login/logout buttons still work but the other buttons on the screen don't work.
Last updated: 2026-04-22
Post by oemcba on Editor FIND highlight color
CODESYS Forge
talk
(Post)
Today is 2026, and we still have the same issue since 2017, anyone have the answer? i'm using V3.5 SP18 P4+ from festo, thanks in advance... @rudolsto @r.evbatyrov @cole @mahmutonx @root @codesys-com
Last updated: 2026-03-06
Post by reinier-geers on Resize and position Numpad/Keypad
CODESYS Forge
talk
(Post)
HI, I download the scale dialog. But cant find were i can Set the size of the dialogs. only the position. I want the diolog bigger
Last updated: 2026-04-15
Post by user3000 on Can't find an Extended Pulse Timer (TP and LTP)
CODESYS Forge
talk
(Post)
Hello, For my program I need an extended pulse timer, which can be referred to as a retriggerable pulse timer. Where every rising edge of the input resets the elapsed time zero, extending the lenght of the output pulse. The Codesys pulse timer (TP) is a one-shot timer and only resets the elapsed time with the falling edge of the input. There is also a pulse timer (LTP) in codesys, but in my simulation it was also functioning as a one-shot even though the description sounds like LTP should be retriggerable. I have uploaded some timing plots from another PLC program for reference. I am looking for a timer equivalent to the "TEP" diagram. Is there an Extended Pulse Timer in Codesys? Maybe there is a way to manipulate the input so it resets the elapsed time outside the function block?
Last updated: 2023-12-06
Post by ruobian on Analog Input Delay Timer
CODESYS Forge
talk
(Post)
Hello there, I am new here and in programming. I need help with the basics. I am trying to do what I mentioned in the title. I have an analog input. So I have a real or integer data type value. I want to delay it. TON and TOF only work with bool. I think there is a function block that has two inputs, 1 for real or int and 1 for bool. And if bool is true, it will give the output as real or int. I don't know but I need something like this. Actually, it is not exactly like that. In other words, it will not show the real value at the input at the output after a certain period of time. I want it to show the real value from 2 seconds ago continuously. The purpose of doing this is to compare the real value I received with the value from 2 seconds ago and find out whether it went up or down. I am using only FBD. Please help me with this. Thanks in advance.
Last updated: 2024-08-20
Post by kbazzett on "Sequent Microsystems" industrial automation hat raspberry pi
CODESYS Forge
talk
(Post)
Here is a complete list of the Sequent Microsystems Pi hats that work in Codesys. https://github.com/SequentMicrosystems/SM_CODESYS/tree/main/ "For easy install download the .package file and open it on your computer, Codesys installer will know what to do with it." <- This. The Multi I/O Hat fit my needs because of the Analog I/O 4-20ma and RTD. I used a Raspberry Pi 5 and 64b install. The example project is also worth the download. With the sample project open, right click on the Raspberry Pi device and update to whatever you are using (SL, MC, 64b). Enable I2C on the PI. You can jumper the hats Analog Outputs to Inputs and see it function on the Web Visualization. Very Cool! I spent quite a bit of time trying to find this solution so hopefully this update helps others. Here is the video link on how to setup a Raspberry PI as a Codesys PLC https://youtu.be/RPoPscbo3Kc?si=Th4-n-mQ6g5fdHj8
Last updated: 2024-12-05
Post by gseidel on AXIS_REF_SM3 Error Codes?
CODESYS Forge
talk
(Post)
Hi SLUCodesys, dwErrorId is a drive specific error number. The drive documentation should be consulted to interpret it. (Note that you should use MC_ReadAxisError to read this error, see https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/MC_ReadAxisError.html. Accessing the internal variable will result in outdated values if the acis error is not mapped by PDO and is not recommended in general.) uiDriveInterfaceError holds errors of the SoftMotion driver for the drive. It is also an internal variable, not intended for direct access. It is intended for logging, the PLC log will contain the drive interface error, consisting of this number and an error text. My recommendation for handling axis errors in the CODESYS application: 1) Use MC_ReadStatus on the axis to find out whether it is in state Errorstop 2) If in Errorstop, there are two possibilities: an error reported by the drive (MC_ReadAxisError) or an error of the SoftMotion function blocks (output MC_ReadStatus.FBErrorOccured). 3) If there is no drive error, you can use SMC_ReadFBError https://content.helpme-codesys.com/en/libs/SM3_Basic/Current/SM3_Basic/POUs/Diagnostics/FBError/SMC_ReadFBError.html Best regards, Georg
Last updated: 2025-09-24
Post by ragarcia on Error while using UpdateConfiguredIPSettings to change IP address
CODESYS Forge
talk
(Post)
Hello everyone, I am trying to change dynamically by code the IP address of a Weidmuller controller. So I am basically using IoDrvEthernet library to use UpdateConfiguredIPSettings function but I am getting constantly the 'INVALID_STATE' error. Even though I am following a procedure it should work: * First I added on the config file of codesys the following: [SysSocket] Adapter.0.Name="eth0" Adapter.0.EnableSetIpAndMask=1 Adapter.1.Name="eth1" Adapter.1.EnableSetIpAndMask=1 * Secondly I am first disabling the ethernet interface by using Ethernet_0.Enable = FALSE and then executing DED.Reconfigure. After that, I run the Ethernet_1.updateConfiguredIPSettings Code: Ethernet_1.Enable:= EnableDisable; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1, xError=> ErrorReconfigure, eError=> ErrorCodeReconfigure); IF Reconfigure.xDone THEN ErrorCodeIP:= Ethernet_1.UpdateConfiguredIPSettings(IPAddress:= newIP, SubnetMask:= newMask, Gateway:= newGW); END_IF IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Ethernet_1.Enable:= TRUE; Reconfigure(xExecute:= TRUE, itfNode:= Ethernet_1); IF Reconfigure.xDone OR Reconfigure.xError THEN Reconfigure(xExecute:= FALSE); END_IF Can someone help me? Thank you. All I am trying is to find a way to change dynamically with code, the IP addresses of my controller (2 ethernet ports).
Last updated: 2023-12-11
Post by nickpoon on SysProcessCreate stopped working after SP21?
CODESYS Forge
talk
(Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02
Post by sven01 on Documentation / Usage Help For Scripting Engine Libraries
CODESYS Forge
talk
(Post)
Hi, I am still not able to figure out how to use the the classes and their functions. π Let's say I would like to use the function "importfile()" from the class "ScriptTextListObject.ScriptTextListMarker". I would be grateful for an additional example. Thanks! π
Last updated: 2023-08-21
Post by timvh on Detect "Cancel" Press in FileOpenSave Dialog
CODESYS Forge
talk
(Post)
Maybe there is a better way, but a long time ago I created a test application that worked like this: With a button I opened the dialog and I added a "Input configuration - OnDialogClosed" "Execute ST-Code" action to this same button which called the following Function when the dialog was closed: F_OnFileDialogClosed(pClientData); Below this Function which handled the result: // This function is called from the visualization when the dialog is closed. FUNCTION F_OnFileDialogClosed : BOOL VAR_INPUT pClientData : POINTER TO VisuElems.VisuStructClientData; END_VAR VAR dialogMan : VisuElems.IDialogManager; FileOpenCloseDialog : VisuElems.IVisualisationDialog; result : VisuElems.Visu_DialogResult; _sFileName : STRING(255); END_VAR // the DialogManager is provided via the implicitly available VisuManager dialogMan := VisuElems.g_VisuManager.GetDialogManager(); IF dialogMan <> 0 AND pClientData <> 0 THEN FileOpenCloseDialog := dialogMan.GetDialog('VisuDialogs.FileOpenSave'); // gets the FileOpenSave dialog IF FileOpenCloseDialog <> 0 THEN result := FileOpenCloseDialog.GetResult(); // gets the result (OK, Cancel) of the dialog IF result = VisuElems.Visu_DialogResult.OK THEN // Original code gvlFile.FileListProvider(); _sFileName := CONCAT(gvlFile.FileListProvider._stDirectory, gvlFile.FileListProvider.stFile); // do something with this file name... END_IF END_IF END_IF
Last updated: 2023-09-19
Post by sedoerr on Check For Open Dialogs On Client
CODESYS Forge
talk
(Post)
FUNCTION CheckDialogOpen : BOOL VAR_INPUT sDialogName : STRING; END_VAR VAR pstClientData : POINTER TO VisuElems.VisuStructClientData; itfDialogManager : VisuElems.IDialogManager; itfMyDialog : VisuElems.IVisualisationDialog; END_VAR VisuElems.g_ClientManager.BeginIteration(); WHILE (pstClientData := VisuElems.VisuElemBase.g_ClientManager.GetNextClient()) <> 0 DO itfDialogManager := VisuElems.g_VisuManager.GetDialogManager(); itfMyDialog := itfDialogManager.GetDialog(sDialogName); CheckDialogOpen := VisuDialogs.VisuDlgUtil_IsDialogOpen(itfMyDialog,pstClientData,itfDialogManager); IF CheckDialogOpen THEN EXIT; END_IF END_WHILE
Last updated: 2023-09-26
Post by snhatton on Can't open online view of FB instance from code editor, only from Device/POU windows
CODESYS Forge
talk
(Post)
Good morning, Yes, this is a known bug that has been reported. For now, the only workaround is to open the function block instances from the device tree. Regards, -Shawn
Last updated: 2023-11-08
Post by voffi on documentation in function block
CODESYS Forge
talk
(Post)
Using < br > did it for me in CODESYS 3.5.19 // 2023-12-05 Line 1<br> // 2023-12-06 Line 2<br> shows up in Library Manager with line breaks.
Last updated: 2023-12-07
Post by mucleus on What is the solution for "Application stopped on recovery switch request"?
CODESYS Forge
talk
(Post)
Component ID 10 is my own log message by LogAdd Function. I want to know in what cases the application stops.
Last updated: 2024-07-09
Post by rmaas on How to use/create SOTU in LD program
CODESYS Forge
talk
(Post)
You can use the R_TRIG and F_TRIG function blocks to generate a pulse in Rising or Falling edge of your signal. Have a look here: https://content.helpme-codesys.com/en/libs/Standard/Current/Trigger/R_TRIG.html
Last updated: 2024-07-11
Post by ljg007 on Variable assignments
CODESYS Forge
talk
(Post)
That is an output of the Function Block ModbusMasterRTU example: xIsConnected=> xIsConnected In this line the VAR ModbusMasterRTU.xIsConnected is written to VAR xIsConnected xError=> is writing to nothing here.
Last updated: 2024-07-22
Post by jens on Using the Wago 750-658 CAN Gateway
CODESYS Forge
talk
(Post)
Is there any solution for this ? or do you need to use wago runtime and use the function blocks for the CanOpen ?
Last updated: 2024-07-23
Post by grant32 on RAMP_REAL FB is retaining my output value when i try to re use the FB
CODESYS Forge
talk
(Post)
Hello, I'm relatively new to PLC programming. I am trying to creat a ramp down function, I have an example here of what I am using. I can get the function to work, the issue is that the OUT (variable3) value is being held by the FB so after I use it once it no longer works. In this example i set variable3 to 100 and the rest is as seen, over the course of a minute it ramped down to 10 (as desired). But when I deenergize TEST_START, set variable3 back to 100, and then re-energize TEST_START it immediately jumps back to the previously held value 10. The reset on this block just pauses the function and holds the last OUT. In my case I will need the function to start OUT at a set value, ramp down to the IN (variable2) value, and then accept a new OUT value to ramp down next time the block is energized. Hopefully this made sense, if anyone has any advice that would be awesome!
Last updated: 2024-07-29
Post by robert-o on Converting hex bytes to float
CODESYS Forge
talk
(Post)
Try OSCAT_BASIC and Function DW_TO_REAL. DWORD_OF_BYTE my although help. The Lib is open and free. It is not necessary to add this Lib, you can use/copy the source code just to get an idea.