Post by caualima on AI + Programming
CODESYS Forge
talk
(Post)
What do you think about having an AI Agent specialized in ST programming in Codesys? I see this saving hours and hours of work for those who program on a daily basis.
Last updated: 2026-01-24
Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
Hi could you check if this really exists in 4.19.0.0 deploy tool? In your case architecture is missing- see my configuration
Last updated: 2026-02-17
Post by eschwellinger on Unable to deploy "Control for Linux SL 4.18.0.0"
CODESYS Forge
talk
(Post)
can you please check this: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_toubleshooting_deploytool2.html#UUID-b83dc01e-8cff-c574-7efe-8615b95a51ed_section-idm234790234401598
Last updated: 2026-02-19
Post by alexgooi on Codesys KNX implementation
CODESYS Forge
talk
(Post)
Dear Forum, For anyone interested we have solved this problem. Before we were using a KNX TP/IP interface, now we are using a KNX TP/IP router, and it works like a charm now.
Last updated: 2026-03-04
Post by fpawlak on How to register own component - CMAddComponent() or CMAddComponent2()
CODESYS Forge
talk
(Post)
Hi, so really oneone has no idea which way is correct one? Or maybe both are okey if they work for me?
Last updated: 2026-03-13
Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection
CODESYS Forge
talk
(Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27
Post by derpaul on PFC200 Update to 4.9.0.0 - No Connection
CODESYS Forge
talk
(Post)
Hallo Today I decided to perform an Update on my PFC200 but after the Update the Device was not reachable anymore. I tried reseting to factory reset. Software reset and so on, but nothing helps... In my Router I can see it, I cann SSH into the PFC200 but it is not reachable. Then I try to go back to 4.8.0.0 But now I get this error: [INFORMATION] Befehl SSH auf root@192.168.1.17 ausführen: Laufzeitsystem stoppen [FEHLER] Fehlerausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory [INFORMATION] Standardausgabe: /etc/init.d/codesyscontrol: line 34: /opt/codesys/scripts/init-functions: No such file or directory Please help, I can't get this thing working... Regards
Last updated: 2023-09-27
Post by seppi on Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C.
CODESYS Forge
talk
(Post)
Hello everyone, I want to establish communication between my Arduino and my Raspberry Pi via I²C, but I have no idea how to make it work. However, it should work because there are many examples available, although none of them were programmed using Codesys, but rather using Python. My Raspberry Pi will be the master and is supposed to exchange measurement data such as speed and battery capacity with the slave (Arduino). I would be very grateful if someone could help me with my problem. Here is another link that could be helpful. However, I can't find the mentioned libraries
Last updated: 2023-12-03
Post by andre-luis on Check if Codesys runtime is on 'Running' or 'Stopped' state?
CODESYS Forge
talk
(Post)
Hi there, I'm running the Codesys runtime on Windows 64 and I need to know if it is on "Running" or "Stopped" state just after a system crash. The following commands works perfectly well to (re)start it... net stop “CODESYS Control Win V3 - x64" net start “CODESYS Control Win V3 - x64" ...however I'm unable to determine when it is required to be call; I mean, by checking the System Tray icon, it is possible to know if it is on "Stopped" state, but I wanted to run a .BAT command to retrieve it. How can we do that?
Last updated: 2024-07-02
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by jinlee on Reading Camera Feed in Codesys v3.5 webvisu web element browser
CODESYS Forge
talk
(Post)
Hi guys, I have been trying to use web browser element in the visualisation to connect with my IP camera. From the past few weeks, I have not been successful of doing it. I thought it would be very easy to just connect to the ip address, but apparantly it is not. I am using WAGO PLC PFC200 and my PC as a webvisu. or else can you guys please advice me on which kind of camera should I use as a CCTV system in my project instead of IP Camera. Ideally, I want multiple web browser elements to browse my IP Cameras in one frame. Kind regards, Jin.
Last updated: 2024-09-16
Post by alexgooi on Update boot project default unchecked
CODESYS Forge
talk
(Post)
Dear Forum, I'm currently switching to Codesys V3.5 SP19. When I want to do an online change, I get the option to update the boot project, in other (codesys based) packages this is checked on by default. In Codesys V3.5 SP19 (and maybe older versions) this is unchecked by default. We are doing a lot of remote updates with systems that almost never power cycle. In other words when this box is forgotten the system will run fine until a blackout. Is it possible to get it checked on by default? This question was asked before, but no answers where given. https://forge.codesys.com/forge/talk/Engineering/thread/ffb4ffa298/ Thank you in advance.
Last updated: 2024-02-09
Post by francescoc on Logger in ms
CODESYS Forge
talk
(Post)
Hi, I cannot find any documentation regarding the codesys configuration file. I modified this part to have log files saved to disk: [CmpLog] Logger.0.Name=LOGS/PlcLog Logger.0.Filter=0xFFFFFFFF Logger.0.Enable=1 Logger.0.MaxEntries=20000 Logger.0.MaxFileSize=5000 Logger.0.MaxFiles=10 Logger.0.Backend.0.ClassId=0x0000010B ;sends logger messages to SysOut Logger.0.Backend.1.ClassId=0x00000104 ;writes logger messages in a file Logger.0.Backend.2.ClassId=0x00000135 ;sends logger messages as UDP syslog Logger.0.Type=0x314;Set the timestamp to RTC ;Logger.1.Name=/tmp/CommLog ;Logger.1.Enable=1 I need to have milliseconds in the timestamp as well. What value should I use instead of 0x314? Is there any documentation regarding this file? Thank you
Last updated: 2024-03-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by bitor-leao on *EXCEPTION* [ProsessorLoadWatchdog] codesys 3.5.11.40
CODESYS Forge
talk
(Post)
Good night. I am having a problem with CODESYS 3.5.11.40, which gives the exception EXCEPTION [ProcessorLoadWatchdog]. I followed some forum posts and tried to modify the CODESYSControl.cfg file, but it shows: [SysFile] Windows.WorkingDirectory=C:\ProgramData\CODESYS\CODESYSControlWinV3\D5050FE1 Then I go to this directory and try to modify CODESYSControl.cfg according to the forums, but it doesn’t work: [CmpSchedule] ;EnableLogger=0 ProcessorLoad.Maximum=80 ;Timeslicing.Mode=Internal ;Timeslicing.PlcSlicePercent=80 ;Timeslicing.PlcSliceUs=4000 ;Timeslicing.StartOnProcessorLoad=1 ;SchedulerPriority=5 ;SchedulerInterval=1000 I tried to change ProcessorLoad.Maximum to 0 or 100, but it doesn’t compile when I try. I really don’t know what to do,
Last updated: 2025-11-16
Post by reinier-geers on wEBCLIENT Post data api
CODESYS Forge
talk
(Post)
Ive got the webclient axample. If i put https://reversed.notion.site/Marktprijzen-API-89ce600a88ac4abe8c2ad89d3167a83e example to https://reqbin.com/post-online then i get data. If i do the same in Webclient example i get " not a valid graphql request. Why ? sUrl := 'https://graphql.frankenergie.nl/' Request_type_post Contenttype = 1 (json ) Postvalue := '{"query":{"query":"query MarketPrices {\n marketPrices(date:\"2025-12-25\") {\n electricityPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n gasPrices {\n from\n till\n marketPrice\n marketPriceTax\n sourcingMarkupPrice\n energyTaxPrice\n perUnit\n }\n }\n}' I tranfer the postvalue from String to WSTRING
Last updated: 2025-12-25
Post by gorditron on I2C Communication with
CODESYS Forge
talk
(Post)
Hello, I have problems with the I2C communication to an ADS7828 AD converter. I don't get any value back from the chip. I use a Kontron chip (ARM 32SC) with Linux as the operating system. I also use the CmpCharDevice library. ADS7828 parameters Address: A1 = 0 / A0 = 0 = SD = 1 = Single End C2 = 0 / C1= 0 / C0= 0 / Channel 0 PD1 = Internal Reference and PD0 = AD Converter ON Here is my code: VAR b_i2cAdr : BYTE := 16#48; (* Standard I2C-Adresse des ADS7828 *) x_Init: BOOL;(* Flag für die Initialisierung *) b_config_byte: BYTE;(* Konfigurationsbyte für den ADS7828 *) ab_cmd_buffer : ARRAY [0..0] OF BYTE; (* Buffer für den Befehl *) ab_data_buffer : ARRAY [0..1] OF BYTE; (* Buffer für die empfangenen Daten *) ui_adc_value_1 : UINT; (* Ausgelesener ADC-Wert *) I2C_Handle: RTS_IEC_HANDLE; (* Handle für das I2C-Device *) di_result_open: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_adr: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_wr_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_rd_cmd: DINT;(* Ergebnis der Funktionsaufrufe *) di_result_close: DINT;(* Ergebnis der Funktionsaufrufe *) END_VAR //*** Init from the I2C communication port *** IF NOT x_Init THEN I2C_Handle := CDOpen(szFile:= '/dev/i2c-0', dFlags:= O_RDWR, pResult:= ADR(di_result_open)); //* I2C opening * //*** set of the I2C address *** CDIoctl(hFile:=I2C_Handle , dRequest:=1795 , dParameter:=b_i2cAdr , pResult:=ADR(di_result_adr) ); x_Init := TRUE; END_IF (* Hauptlogik *) IF I2C_Handle <> 0 THEN (* Konfigurationsbyte setzen: Single-Ended Kanal 0, interne Referenz *) b_config_byte := 16#8C; (* 10001100b: AIN0, interne Referenz, Single-Ended *) ab_cmd_buffer[0] := b_config_byte; (* Schreiboperation zum Konfigurieren des Chips *) CDWrite(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_cmd_buffer), udCount:= SIZEOF(ab_cmd_buffer), pResult:= ADR(di_result_wr_cmd)); IF di_result_wr_cmd = 0 THEN (* Leseoperation, um den ADC-Wert zu erhalten *) CDRead(hFile:= I2C_Handle, pbyBuffer:= ADR(ab_data_buffer), udCount:= SIZEOF(ab_data_buffer), pResult:= ADR(di_result_rd_cmd)); IF di_result_rd_cmd = 0 THEN (* ADC-Wert aus den Daten extrahieren *) ui_adc_value_1 := SHL(TO_UINT(ab_data_buffer[0]), 8) OR TO_UINT(ab_data_buffer[1]); ELSE (* Fehler beim Lesen der Daten *) ui_adc_value_1 := 0; (* ADC-Wert auf 0 setzen *) END_IF ELSE (* Fehler beim Schreiben der Konfiguration *) ui_adc_value_1 := 0; END_IF END_IF
Last updated: 2024-12-13
Post by ihatemaryfisher on Sorting array of any-sized structure
CODESYS Forge
talk
(Post)
With that I could make an array of varying size, but would still have to define the array type in the function's declaration VAR_IN_OUT stArray: array [*..*] of <pre-defined data type> END_VAR I wanted a function that could take an array of any type (e.g., a structured VAR) as an input. That way I could call it in multiple POUs to handle different arrays structures.
Last updated: 2023-08-18
Post by song on How to convert a standard robot program into an excutive list when a robot runs?
CODESYS Forge
talk
(Post)
Dear Sir, I'd like to learn and try to make robot based on Codesys, is there a FB block or other ways to convert a standard robot program into an excutive list? how codesys explain the robot command instructions on HMI, just like the SMC_NCDecoder used to convert CNC program into a list of SMC_GEOINFO object. Thanks very much! Peter Yan
Last updated: 2023-11-25
Post by kislov on Change modbus server parameters from program
CODESYS Forge
talk
(Post)
Use in IEC-code: Modbus_Serial_Device.UpdateComPortSettings(...) https://content.helpme-codesys.com/en/libs/IoDrvModbusSerialSlave/Current/pou-ModbusSerialDeviceDiag/UpdateComPortSettings.html Take note: "Only possible if server is disabled (see xEnable Input)" So: Modbus_Serial_Device.xEnable := FALSE; Modbus_Serial_Device.UpdateComPortSettings(...) Modbus_Serial_Device.xEnable := TRUE; Please note that after PLC reboot the values from the GUI (from your screenshot) will be applied again. So you need to save values from HMI in RETAIN and restore them after start of application.
Last updated: 2024-07-17
Post by mrbartpawlowski on OMAC PackML library 1.0.04
CODESYS Forge
talk
(Post)
Hello all, Can someone point me to the OMAC PackML State Machine library documentation, I can't find any description of the block functionality ? I was looking into https://content.helpme-codesys.com/en/libs/index.html but there's no PackML there. I'm new to Codesys and don't know if I'm doing something wrong here ? In library tab in codesys whenever I want to see documentation I'm getting an error. Regards Bart
Last updated: 2024-08-15
Post by mrbartpawlowski on OMAC PackML library 1.0.04
CODESYS Forge
talk
(Post)
Hello all, Can someone point me to the OMAC PackML State Machine library documentation, I can't find any description of the block functionality ? I was looking into https://content.helpme-codesys.com/en/libs/index.html but there's no PackML there. I'm new to Codesys and don't know if I'm doing something wrong here ? In library tab in codesys whenever I want to see documentation I'm getting an error. Regards Bart
Last updated: 2024-08-15
Post by bzzz on Connect WS2812B Light Strip to CodeSys via RasPi
CODESYS Forge
talk
(Post)
Hey guys, I have a RasPi and can control my WS2812B (addressable light strip) via Python. The lightstrip is this one: https://core-electronics.com.au/1m-rgb-led-strip-ws2812b-144-per-meter-white-strip-weatherproof.html What I would like to do is to control it directly via CodeSys through the plc on my RasPi. I know I can run a python script on CodeSys, but I'd like to avoid doing that. Is it possible, and how do I do it? Is there a library that does this?
Last updated: 2024-10-16
To search for an exact phrase, put it in quotes. Example: "getting started docs"