Search talk: Object reference not set to an instance of an object

 
<< < 1 .. 255 256 257 258 259 .. 268 > >> (Page 257 of 268)

Post by aliazzz on Raspberry Pi 3: Linux/ARMHFv7 unknown container technology CODESYS Forge talk (Post)
Hi CODESYS team! It seems Podman for Raspberry Pi 3 is not detected correctly in the latest "Deploy Control SL 4.14.0.0" : Linux/ARMHFv7 unknown container technology. 1) The Communication Tab, device information section shows podman technology as DETECTED. 2) The Runtime Deployment menu message says: "unknown container architecture" 3) The pulldown window under the deployment tab doesn't show the options for ARMHF Virtual Edge SL and ARMHF Virtual Control SL. I hope you can fix this soon and keep up the great work!
Last updated: 2024-12-15

Post by kuapiz on Camera RTSP Feed CODESYS Forge talk (Post)
Hello, I'm facing the same problem, I can access the FLIR AX Series camera through the IP converter software (go2rtc). In the CODESYS 3.5.19 patch 7 software, the streaming does not appear in the webvisu even using the URL "http://xxx.xxx.x.xxx:1984/stream.html?src=flirr". I used the "RTC" and "MJPG" modes. HW: PFC200 750-8217/600-000. FW: v27. If anyone has a solution, could you help us?
Last updated: 2025-03-05

Post by wayne-riesterer on Assignment Efficiency - Repetitive Assignment vs IF statement CODESYS Forge talk (Post)
Hello Can anyone see any problems with constant assignment as in the following statement: Coils[0] := Coils[0] OR (Buttons[0] AND Sensors[0] > 6); Rather than using the more verbose and vertically-larger: IF NOT Coils[0] AND Buttons[0] AND (Sensors[0] > 6) THEN Coils[0] := TRUE; END_IF Also, is the test expression short-circuited in the latter case? In other words, will the runtime move on after it sees Coils[0] = FALSE AND? Thanks
Last updated: 2025-03-07

Post by schorge on Modbus RTU Slave CODESYS Forge talk (Post)
Ich würde gerne bestimmt Modbus RTU Slave Adressen auslesen, leider bekomme ich keine Werte vom Bus. Verbindung erfolgt über einen Raspberry mit Modbus RS485 Adapter, welcher erfolgreich verbunden ist. Mit einem IOBroker kann ich die Daten erfolgreich auslesen. In der Modbus_COM_Port => Modbus_Serial_Device habe ich Input Register 4000 %QW und Startadressen auf Input Register 3000, als Variable ein Array[0..2999] of Word, kann aber keine Werte auslesen.
Last updated: 2023-12-06

Post by theo on Error codesys raspberry CODESYS Forge talk (Post)
Bonjour a tous je souhaiterai connecter mon Raspberry a codesys en tant qu'automate cependant lorsque je enterent l'IP dans le encadré et que je fais entrer voici le message qui apparait, je suis français mais en anglais ça signifie : " vous n'êtes actuellement pas autorisé a exécuter cette action sur l'appareil. Please enter the username and password of a user account with the required access rights.
Last updated: 2023-12-08

Post by preimesbergert on Codesys Control for Raspberry Pi 4.10.0.0 - Raspberry Pi OS > 2023-12-05 CODESYS Forge talk (Post)
Same issue here: Raspberry Pi 4 Model B HW 1.5 Regardless of the image (tried 32bit / 64bit version from Raspberry Pi Imager- all the "standard version") and with all tested Codesys Control versions (4.2.0, 4.8.0, 4.10.0) and regardless if single core / multicore / 64 bit variant.
Last updated: 2023-12-21

Post by martinlithlith on Raspberry Pi: List of available drivers / libraries CODESYS Forge talk (Post)
Hi! I'm still on the hunt for drivers for example TCA9548 and a list or somewhere where all devices for raspberry is gathered. as this post is quite old I'm hoping/gussing that there is somewhere where work after 2021 is gathered? Or has the raspberry part if the community slowed down on creating device drivers?
Last updated: 2023-12-31

Post by dhumphries on Rounding error in simple addition CODESYS Forge talk (Post)
I have discovered a rounding error, either in Codesys or in my understanding of numbers. The attached ladder shows that when the up button is pressed the number increases by 0.1, when the down button is pressed number decreases by 0.1, after several button presses the number isn't equally divisible by 0.1. Have I discovered a bug or am I doing something wrong?
Last updated: 2024-04-27

Post by hua-huang on Compile problem - can't get .bin or .h86 file CODESYS Forge talk (Post)
Hello, I am programming for IFM controller CR7132, after I check 'create binary file of the application' and 'rebuild all', there is no error when compiling but no .bin or .h86 file generated. Could someone please inform the correct way? Thanks in advance! BR, Hua
Last updated: 2024-09-12

Post by tortillamarcal on TargetVisu Freezing CODESYS Forge talk (Post)
Hi, I have project that worked during months. This one have targetvisu where I move between screens with a frame using the function flick/slide. The last weeks when i move sliding the screen freeze but the comutation tag of the frame continue registration the movements. The program continue working at the background but the screen freeze. Has anyone encountered something similar? Thanks!
Last updated: 2024-09-12

Post by nano on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
the codemeter deb files are part of the runtime-sl-installatonfiles. so u can download the whole raspberry pi package from store-page, unzip it with a progam like 7zip, there you'll find a folder called dependencys i thing. here should the deb files placed
Last updated: 2024-09-18

Post by cakar16 on Looking for BL20-PG-EN-V3, V3.5.11.20 Device Driver CODESYS Forge talk (Post)
Hi Everyone, I am Karnadi I am looking for device driver for the following Turk devices and version: - BL20-PG-EN-V3, V3.5.11.20 (Turk) - BL20-2RFID-S, V1.1.3.0 (Turk) - BL20-1RS485/422, V1.1.3.0 (Turk) - BL20-4DO-24VDC-0.5A-P, V1.1.3.0 (Turk) - Ethernet, 3.5.11.20 (Turk) Appreciate if anyone of you can share the device driver (config package) above Thanks and Regards Karnadi
Last updated: 2024-10-04

Post by spoun on Problem with edge gateway config mode CODESYS Forge talk (Post)
I installed patch 3 now and i get a new message, although i located and modified the files in system32 and sysWOW64 still doesn't work. One thing i noticed is thta in system32 folder CODESYSGatewayV3 now i have two different XXXXXXXX files with the latest being created today at the time of installation
Last updated: 2024-10-21

Post by pascaljt on Warning code C0373 CODESYS Forge talk (Post)
Hello, I wrote a function block for a controller but I have a warning code C0373 "expression or part of it has no effect" and the sub routine which contain my function block is underlined in blue. Despite, the FB works perfectly. Do you know why I have this warning ? Thanks. Pascal.
Last updated: 2024-10-30

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by reinier-geers on Energie price CODESYS Forge talk (Post)
On a website i can get the energie price. But how does that work in codesys? There is a video of Rest client. But i can find the HTTP library. If i type on my browser : https://enever.nl/api/stroomprijs_vandaag.php?token=ANWB i get {"status":"true","data":"Please provide a valid API token. More information at https:\/\/enever.nl\/prijzenfeeds\/","code":"2"}
Last updated: 2024-12-03

Post by ekristoffe on Modbus UDP CODESYS Forge talk (Post)
UDP has no packet ordering mechanism, and Modbus protocol has no order checking mechanism nor session establishment. I'm sorry but this is false, Modbus IP based have the Transaction Identifier. Transaction Identifier - It is used for transaction pairing, the MODBUS server copies in the response the transaction identifier of the request. Modbus UDP make more sense than Modbus TCP in a local environment.
Last updated: 2025-01-14

Post by gseidel on Dynamic limits invaild CODESYS Forge talk (Post)
Hi jbu0105, which error doe you get, exactly? Is it error 11008, SMC_MOVE_INVALID_DYNAMICS? (It might help if you check the "Log" tab in the PLC device and copy the exact error.) Please double-check whether the inputs Velocity, Acceleration, Deceleration, and Jerk of MC_MoveCircularAbsolute have correct (positive) values. Best regards, Georg
Last updated: 2025-04-07

Post by esave on Stepper Drive with Ethercat CODESYS Forge talk (Post)
Hello everybody I am new into Codesys. I have a stepper driver (EM3E-556E) from Leadshine. I want to controll the stepper driver via EtherCat to a ST programm but I dont have any function block or anything that i can use. I only have the XML-File wich I loaded. With it I implemented the drive as a Ethercat slave and now I see these variables. (See picture) I dont know how to controll the stepper drive. And the manufacturer doesnt provide support for me. Can anybody help me or atleast tell me how they would do it?
Last updated: 2024-03-14

Post by yannickasselin on codesys VLAN tagging CODESYS Forge talk (Post)
I ordered a cheap managed switch and tested it as soon as I received the switch. It works great! I even went a bit further. As you can see in the screenshot, I created 2 Codesys containers. Each one having 2 fieldbuses. The first one has EtherCAT and EtherNet/IP and the second one has EtherCAT and Modbus/TCP. All going through the same ethernet port from the PC to the switch. The switch splits it up into 4 different networks. The hardest part was to figure out how to configure the switch. @eschwellinger, thank you very much.
Last updated: 2024-09-17

Post by mazino on How to download dependencies packages for CODESYS Control for Raspberry Pi SL ? CODESYS Forge talk (Post)
Hi starmaxou, I’m facing the same issue you mentioned with the dependencies for the CODESYS Control for Linux SL installation. I was able to find the manual downloads for the CODESYS Edge Gateway and CodeMeter, but I’m still stuck on the other two dependencies: CODESYS Control SL Extension v4.0.0.0 CODESYS Control SL Deploy Tool v4.10.0.0 Since you’ve encountered the same problem, I’d really appreciate any help or insights you can share on how you were able to resolve it. Any tips or suggestions would be greatly appreciated! Thanks in advance!
Last updated: 2025-03-07

Post by pauloricardoss on Codesys Control Raspberry PI 4.10.0 - missing 'Update Raspberry PI' option CODESYS Forge talk (Post)
I am having the same problem. 'Update Raspberry PI' disappeared from the 'Tools' menu. Using RaspberryPI 3B+, Codesys V3.5 Sp21 + RaspberryPI Package 4.16. I installed the package as Administrator, executed Codesys as Administrator I also tried to connect using the deploy (even with ssh and everything enabled on the RaspberryPi I received password denied). I used in the past the same equipment with Codesys V3.5 Sp18 and RaspberryPI Package 4.08, it was really easy. (I also did a brand new RaspbianOs installation to make sure that nothing affect the connection). Anyone, knows how to fix it? Thanks,
Last updated: 2025-06-13

Post by timl on BacNet "Unaufgelöste Referenz" CODESYS Forge talk (Post)
Hallo, ich habe Probleme beim nachbauen des BacNet2 Tutorials "Erste Schritte" aus der CODESYS Online Help. https://content.helpme-codesys.com/de/CODESYS%20BACnet/_bacnet_first_steps.html Das Anlegen des BacNet2 Servers und der danach folgenden BacNet Datenpunkte erfolgt ohne Probleme. Der Code lässt sich mit F11 auch Fehlerfrei generieren. Beim Download auf die SPS tritt dann der Fehler auf dem Bild auf. Anbei auch ein Bild des Logs nach dem Download. CODESYS BACnet 2.0.0.0 ist über den Installer runtergeladen. Device: CODESYS Control Win V3 x64 Version 3.5.19.40 CODESYS 3.5.19.40 Im Bibliotheksverwalter ist BACnet2 2.0.0.0 aufgeführt Die Konfigurationsdatei habe ich mit folgenden anpassungen abgespeichert: [ComponentManager] Component.1=CmpTargetVisuStub Component.2=CmpWebServer Component.3=CmpWebServerHandlerV3 Component.4=SysCpuMultiCore Component.5=SysReadWriteLock Component.6=SysCpuBreakpoints Component.7=SysPipeWindows ;Component.8=CmpHilscherCIFX ;Component.9=CmpPCANBasicDrv ;Component.10=CmpCANFoxDrv ;Component.11=CmpIxxatCANDrv ;Component.12=CmpBlkDrvCanServer ;Component.13=CmpBACnet Component.14=CmpBACnet2 [CmpBACnet2] ;configuration file of the BACnet stack IniFile=$PlcLogic$/bacstac2.ini ;task priority of the BACstack process task, default: TASKPRIO_NORMAL_END (159) TaskPrio=128 ;name of the named pipe for the communication with the BACstack AppName=/tmp/BACnetServer Habe ich etwas vergessen?
Last updated: 2024-02-16

Post by c3po on Von SNMP auf IIoT wechseln CODESYS Forge talk (Post)
Hallo, 1. ich bin komplett NEU was Codesys angeht 2. ich muss direkt ein Retrofit machen von V2 auf V3 3. Neue Steuerung: WAGO 750-8211 PFC200. 4. das Projekt in V2 hat über SNMP daten im Netzwerk zur Verfügung gestellt, oder diese gelesen 5. das Projekt in V3 kann SNMP nur noch eingeschränkt nutzen, deswegen wurde mir vom WAGO Support nahegelegt die IIoT Lib zu verwenden. Frage: Wie mach ich das? Konkret: Ich habe die WagoAppSNMP Bibliothek installiert, damit kann ich schon mal Set und Get nutzen (hoffentlich, hab es ja noch nicht getestet, sondern nur programmiert). Ist das ein schlauer Weg, das über diese Lib zu machen? Denn: was macht der SNMP_SET_PLCDATA_WRITEAREA ? Den kann ich über die Wago Lib nicht nutzen und weiß auch nicht, was dieser Baustein konkret tut (Bild im Anhang). Es scheint mir, hier werden Daten auf ein Word im Netzwerk geschrieben? Aber geht das nicht auch einfacher? Es ist ja keine Adresse hinterlegt, wo das hin gehen soll oder? Also, ich verstehe den Baustein nicht so ganz und konnte bisher auch keine Erklärung dazu finden. Vielen Dank schon mal für eure Unterstützung, K.
Last updated: 2024-08-19

Post by svn123 on Can V3.5.19 and V2.3.9 be installed on same Windows10 PC without affecting each other? CODESYS Forge talk (Post)
Hi All, Seasons Greetings! I have Codesys V3.5.19 patch 5 installed on a Windows 10 PC. I have received a program which is for Codesys V2.3.9. First I tried to convert it but had many conversion errors. I am wondering if it is possible to install Codesys V2.3.9 on same PC without affecting the V2.5.19 installations. Is this possible? SVN123
Last updated: 2023-12-28

<< < 1 .. 255 256 257 258 259 .. 268 > >> (Page 257 of 268)

Showing results of 6677

Sort by relevance or date