Post by thomaspfrimmer on Can't import enums OnlineChangeOption / ResetOption
CODESYS Forge
talk
(Post)
Hello Jusito, Can you share your final code, please ? I tried to implement a similar feature (going online, doing the reset and the start). But I get a timeout on the reset/start when I'm testing the script. If you got something working, I would appreciate to see it.
Last updated: 2024-04-11
Post by danwoodlock on Rpi zero w lost license after 4.11 update
CODESYS Forge
talk
(Post)
Just adding some info: Today I found this post: https://forge.codesys.com/forge/talk/Runtime/thread/264bd530d4/ followed the steps suggested started with a fresh install of raspbian lite, installed 4.11, and then attempted to import my license update file. I get this when I do: Any help is appreciated.
Last updated: 2024-04-15
Post by michelebianchi on cm4 runtime problem
CODESYS Forge
talk
(Post)
hello i have installed codesys runtime mc sl and sl on a CM4 but after 30 second process exit. have tried those runtime versions: 4.08 4.09 4.10 4.11 i get this message in all situations: ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) os version is raspbian bullseye
Last updated: 2024-05-02
Post by andrej on Channel timeout CmpChannelMgr
CODESYS Forge
talk
(Post)
Hello, I use Codesys RTE 3.5.16.5. If I connect to the PLC I often get the following message: (see printscreen) 1. Channel timeout CMpChannelMgr. 2. Closing connection CmpChannelMgr. Can you tell me, what the meaning of this is? What does the number 1250030,1220020 resp. c400:0a0a:015a:0301 refer to? I could find any information in the online help. Thanks a lot.
Last updated: 2024-05-08
Post by walkercope on Ethercat bus on Beckhoff CX with Codesys for Linux
CODESYS Forge
talk
(Post)
Has anyone figured out a way to use the ethercat bus on a beckhoff CX using codesys running on linux? Using ethercat on the native NICs works fine but I get a "packet could not be sent" error when trying to scan the ethercat bus device. Errors and hardware in attached image.
Last updated: 2024-05-13
Post by micik on CAA File- FILE_OPERATION_DENIED error
CODESYS Forge
talk
(Post)
Hello, I'm trying to use FILE.Open to open file that exists in the given location. sFileName is formed from "Copy as path" in Windows. So I'm sure file exists and it is in the given location. And still, I get thiss denied error. What could be the problem here? Attached is a screenshot with current implementation.
Last updated: 2024-05-16
Post by mgengler on Recipe Manager - Not Creating Recipe Files
CODESYS Forge
talk
(Post)
Thanks for info... However, I changed the directory to: C:\ProgramData\CODESYS\CODESYSControlWinV3x64\58719825\PlcLogic\Recipes It still displays the content of this folder OK, however still will not write or read files. Is this the PLCLogic area you speak of? I also tried adding this path the the CodesysControl.cfg file. But still can't get it to work. Any additional direction would be appreciated!
Last updated: 2024-05-20
Post by totorovic on IO-LINK Package - new license model
CODESYS Forge
talk
(Post)
Hello, I'm using th IDE Combivis studio 6 (codesys based) and I get an error message when I use IO-link. "The license is missing or invalid. The API is running in demo mode." However the package Manager indicates that no licence is required. It used to work, it seems that the free package has become a paying one. Can Codeys confirm this? BR
Last updated: 2024-06-06
Post by mos89p on how to use UseDataExpanding() in datasource
CODESYS Forge
talk
(Post)
Hi I need to update by software some structures in my datasource, i found this example: https://content.helpme-codesys.com/en/CODESYS%20Communication/_cds_update_data_interface.html it seems that because i use complex variable structure i need to use UseDataExpanding() instead of use data, the question is how to get an instance of IDatasourcesMgr3 i have the global variable g_Datasources is instantiated automatically
Last updated: 2024-06-18
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by pharus on Setup problems with PiXtend
CODESYS Forge
talk
(Post)
Hello all, I have an PiXtend V2L complete kit and installed everything like in the manual. Ive installed Codesys V3.5 S20 Codesys Control for Raspberry Pi PiXtend_V2_Professional_for_CODESYS.package But as soon as i Create a Project, i get a lot of error messages, and i cant find the PLC via Ethernet Thanks a lot
Last updated: 2024-06-19
Post by trannhantxqt on Tripod rotary coordinate is not correct with right hand rule
CODESYS Forge
talk
(Post)
Hi all, I work with tripod rotary kinematics in codesys robotics lib and I got a problem with WCS coordinate. My robot WCS dont look like right hand rule, you can see in the image. (WCS Y axis is negative) Anyone here get the same problem? :D It make me so confuse.
Last updated: 2024-06-22
Post by rschwager on GVL to SHMem
CODESYS Forge
talk
(Post)
Hallo! Have some any idea to transfer whole GVL to Shared Memory? I also shared REATIN memory to shraed meory for making a Retain Backup System without USP in Linux on a FRAM. For an other Application we want to shared the whole GVL off obne part (e.g. GVL_Test). How cvan I get easy the Size and the Address for meory copy?
Last updated: 2024-07-09
Post by trusty-squire on CNC - How to manipulate SMC_GeoInfo objects
CODESYS Forge
talk
(Post)
Sometimes you just need to pose a question on a forum and re-read it to get clarity. pGeoInfo := SMC_GetObj(poq:=ADR(fbCncInterpreter.poqDataOut), n:=1); This won't work, I'm providing a pointer to a pointer, as poqDataOut is already a pointer! I just need to remove the ADR() and it works. pGeoInfo := SMC_GetObj(poq:=fbCncInterpreter.poqDataOut, n:=1);
Last updated: 2024-07-26
Post by haiderm on MultiTouch : Two fingers pinch to Z00M in/out and rotation gesture.
CODESYS Forge
talk
(Post)
Hello, I am currently trying to implement the Pan gesture and if possible, also the spread-pinch gesture in my project. The Pan gesture seems to work. Was the spread pinch gesture in the meantime fully released, because i haven't been able to get it called? Best Regards, Michael
Last updated: 2024-08-02
Post by lukebouchard on IFM-Sensor ADC READ
CODESYS Forge
talk
(Post)
Get a different sensor that is 0-10V and 0-350 Bar. There is nothing you can reasonably do to boost the range of the sensor, and the PLC will only ever be 0-10V. Take away is to always be careful to match the sensor and PLC input ranges in the future.
Last updated: 2024-08-24
Post by dengsberg on Disable Communications to 'Modbus_Server_COM_Port' from the logic
CODESYS Forge
talk
(Post)
I have a serial Modbus RTU communicating to the Slave device. But when the control system is not in Run there is no power applied to one of the Modbus Devices. Can I enable / disable the communications to that Modbus Slave in the code based on my running mode, so I don't get all the errors?
Last updated: 2024-08-29
Post by codesysdave on CoDeSys 3.5 SP20 "No Offline Help installed"
CODESYS Forge
talk
(Post)
What does this message mean, in the Errors/Messages box? "[ERROR] MyProjectName: No Offline Help installed" In CDS23, I used to be able to select a system function with the mouse, and press F1. Help and description would popup. How do I get so-called On-line Help installed?
Last updated: 2024-09-06
Post by dengsberg on Check Connection Status of the OPC-UA Server for Data Source Manager with OPC-UA Client
CODESYS Forge
talk
(Post)
I am using the Data Source Manager with OPC-UA Client to get data from another CodeSys application in the same Project. How can I check in the PLC_PRG structured text if the connection is ok or not?
Last updated: 2024-09-07
Post by hua-huang on Compile problem - can't get .bin or .h86 file
CODESYS Forge
talk
(Post)
Hello, I am programming for IFM controller CR7132, after I check 'create binary file of the application' and 'rebuild all', there is no error when compiling but no .bin or .h86 file generated. Could someone please inform the correct way? Thanks in advance! BR, Hua
Last updated: 2024-09-12
Post by garmusd on Raspberry Pi 5 GPIO not working.
CODESYS Forge
talk
(Post)
Hi, Codesyscontrol 4.13.0.0 Raspberry Pi5 64bit with latest updates. Cant get working GPIO - no output and no input. SPI/I2C not tested. GPIOs B+/Pi2, Input/Output is set in the parameters, assigned variables int the Mapping. Absolutely no reaction. Do I need to configure anything else to make it work? Thanks!
Last updated: 2024-09-26
Post by davidbo on Modbus: Is there a way to get the channel index from the channel name?
CODESYS Forge
talk
(Post)
When I use the FUNCTION_BLOCK ModbusChannel I have to sepcify the integer iChannelIndex It can easily go wrong if one has many channels. It would be better if one could use the name. Is that possible? Attached a snippet of the channel name and the channel index to the left.
Last updated: 2024-10-21
Post by spoun on Problem with edge gateway config mode
CODESYS Forge
talk
(Post)
I installed patch 3 now and i get a new message, although i located and modified the files in system32 and sysWOW64 still doesn't work. One thing i noticed is thta in system32 folder CODESYSGatewayV3 now i have two different XXXXXXXX files with the latest being created today at the time of installation
Last updated: 2024-10-21
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND
or OR
.