Search talk: %I %s

 
<< < 1 .. 28 29 30 31 32 .. 94 > >> (Page 30 of 94)

Post by edepalos on Text list from sd card CODESYS Forge talk (Post)
Hi guys, I have a textlist in my project which is working just as expected in a drop down list. I would like to move this text list to a sd card and access it from there, because I want to ease the editing of the contents of this textlist. I'm imagining a solution like the operator shuts down the plant, takes the sd card out, edits the textlist on the card with a windows machines notepad, then reinserts the card in the PLC and restarts the plant, having the new content of the textlist populating the dropdown list. I'm sorry that I'm asking you to spoonfeed me, but I did not find anything straightforward to do this... I saw in the Project>Project settings>Visualisation a relative path thingy, but I have the plant in operation and I would not like to make 100 trial and errors right now... I'm also not interested in SysLib file read commands and stuff, I would just like to access the file from the cards part, I don't want to replace its contents dynamically or such... nor I have language files or recipes... Thank You in advance! Br, Ede
Last updated: 2024-01-16

Post by sigurdrb on send appliaction files to wago plc (codesys 3.5) via ssh CODESYS Forge talk (Post)
Hi, I was hoping I could send the two files "application.app" and "application.crc" directly to the directory "/home/codesys/PlcLogic/Application" instead of logging into the device with codesys, downloading the program to the controller and then do the "create boot application", so it will reboot with the correct program running. I think i also need to edit the file "eRUNTIME.cfg" located in the "/home/codesys/ folder, because when I create the boot application from the codesys IDE, these lines are added to the file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app=0x212520, 0x2DBC747E, 2DBC747E.app I think the "eRUNTIME.cfg" file is the same as CODESYSControl.cfg I also dont know the purpose of the hexadecimal numbers etc. that is generated. When I tried to replicate what codesys was doing, I placed the same files in the same folder as when codesys generated the boot file. And also added the lines in the eRUNTIME.cfg file: [CmpApp] Application.1 = Application [SysFileMap] /home/codesys/PlcLogic/Application/Application.app The controller did not boot up with any program, so my method did not work at all. I guess these lines tells the controller to run an application and where to find it? Could any of you help me with the best way to get the compiled program to the controller without using codesys or wago-software?
Last updated: 2024-05-28

Post by ricola on ERROR: CodeMAccess2: Used CmRuntime 2.61.2705.500 is too old CODESYS Forge talk (Post)
hi there , can someone tell me how to deal with this error , please? I use the Linux ARM64SL (4.11) on a bullseye distro and when I want to update or install some package, I have the following reply : pi@NanoPi-R5C:~$ sudo apt upgrade Reading package lists... Done Building dependency tree... Done Reading state information... Done You might want to run 'apt --fix-broken install' to correct these. The following packages have unmet dependencies: ** codesyscontrol : Depends: codemeter but it is not installable or codemeter-lite but it is not installable** E: Unmet dependencies. Try 'apt --fix-broken install' with no packages (or specify a solution). and if I try apt --fix-broken install as suggested, I have a proposal to uninstall codesyscontrol ... :-D so I tried to search if there is some Codesys repo: nothing, then I tried to see if ther was something inside Codesys dev (V3.5.20) and I only found that by reading/requesting my device, i spoted that codemeter was too old . I don't see how to deal with this issue. is there a codemeter.deb somewhere ? thanks in advance for any help.
Last updated: 2024-09-17

Post by maldus512 on How to adapt Codesys Control SL to custom board CODESYS Forge talk (Post)
Hello everyone, I have been given the task to develop I/O drivers for a custom made, Linux based board to allow for Codesys applications to run and control the hardware. I have successfully installed Codesys Control SL for ARM/Linux and tested it with a simple demo application. Now I should start interfacing the runtime to the actual hardware; I should be able to interact with 2 RS485 serial ports, a few GPIOs and an I2C port, all of which already have the corresponding /dev/ interface in the Linux system. I am having trouble understanding how it should be approached. I have found sporadic references that fail to lead to a really comprehensive documentation. For example: The store page (https://store.codesys.com/en/codesys-control-for-linux-arm-sl-1.html#options) mentions a "runtime package" that should allow "Integration of existing C code" and "Usage of local I/Os", which seems exactly what I need to interact with custom peripherals. I have found no further reference to Codesys-C interpop. The Codesys Help page for the runtime package has a page on the "Development of Drivers" (https://content.helpme-codesys.com/en/CODESYS%20Control/rtsllinuxrbpdriverdevelopment.html) that suggests to either "Implement a function block" or "Implement I/O drivers". Those in turn lead to this page (https://forge.codesys.com/drv/io-drivers/doc/Generic/) which describes briefly an XML schema to describe new devices; unfortunately, it doesn't mention what to do with such a description (i.e. how does the runtime know about it) or how it is in any way connected to the actual hardware. Could anyone give me some pointers? I should also mention I have no prior experience with Codesys, so maybe I'm missing an obvious answer.
Last updated: 2024-08-09

Post by rossanoparis on Upgrading CODESYS runtime from v4.7 to v4.9 using a bash script leads to lose the licences stored in the soft container CODESYS Forge talk (Post)
System information - Controller: KUNBUS RevPi CONNECT-S - OS: Linux buster 32bit 5.10.103-rt62-v7l #1 SMP PREEMPT_RT armv7l GNU/Linux - CODESYS v3.5 SP19 Patch 2 I'm facing a problem related to codesys licences using a procedure based on a bash script. Such bash script detect the presence of new .deb files and install them on system. My automation solution don't allow to be maintained by dedicated personal, thus even the CODESYS runtime SW must be installed using an "automatic" procedure instead of using the CODESYS tool. remark I've been using the following procedure since the runtime v4.5 without any issue. Before installing the new runtime packages, I need to copy the file CODESYSControl_User.cfg (here attached) because of new section which is necessary to add in order to allow some folders to be written by CODESYS runtime v4.9 Up to now, this has been unnecessary, this is the main difference between my previos bash file and the new one. remark If I skip this action, everythings goes fine, but my CODESYS application can't work as it needs to access some folders on controller's file system. Process - Before the procedure: the licenses are OK (see attached file lic-01.png) - After the procedure: the new CODESYS runtime version is correctly installed, but the software container with v1.19 and all licences disappear (see attached file lic-02.png) This is the synthetic content of bash script I'm using. # Stop runtime sudo service codesyscontrol stop sudo service codesysedge stop # Move the new CODESYSControl_User.cfg file # New configuraton with folders declared sudo mv -f CODESYSControl_User.cfg /etc # Install runtime package echo N | sudo apt-get install -y --allow-downgrades codesyscontrol_raspberry_4.9.0.0_armhf.deb # Install edge gateway package echo N | sudo apt-get install -y --allow-downgrades codesysedge_edgearmhf_4.9.0.0_armhf.deb # Reboot controller sudo reboot Thanks in advance
Last updated: 2023-09-19

Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5) CODESYS Forge talk (Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02

Post by jackbrady on Function Blocks and arrays of function blocks CODESYS Forge talk (Post)
Hello, I am new to Codesys and PLC programming in general (please go easy ha!) I'm not looking for code to be written for me just some help and pointing in the right direction. I am writing some code to send commands to a relay based on input values (to put it simply). Quite basic stuff. I have wrote a function block that takes a global variable (Open_command:BOOL) and outputs to another global variable (Opened : BOOL). The function block is simulating a device so I'll eventually get the globals from that. I now need to create multiple versions of this function block/ device (lets say 100) but I need each iteration of that function block to reference it's own relevant global variable. I think that the best way of doing this would be to use arrays, although I could be wrong. I am aware that for up to 100 instances I could very well manually assign everything but that seems rather time consuming and I want a fancier way of doing it. Here is a very basic example of what I am looking to do, please note I have not written this in proper code it's just to show what I mean. Global Variables V[0-100] int Open_command [0-100] Bool Opened [0-100] Bool Function Block var input x : BOOL Var output y : BOOL if x then y = TRUE ELSE y = FALSE The input to my function block will be Open_command, output will be Opened Example code. If V[x] > 10 then Open_command [x] = TRUE ELSE Open_command [x] = FALSE (So when V1 goes above 10 I need Open_command1 = TRUE therefore initiating FB1 output. V2 > 10, open_command2 = True > FB2 output V3 > 10, open_command3 = True > FB3 output ... ... ) What I can't seem to figure out is how to tie all this together, I have read through the codesys documentation and if anything it has confused me more! ha. Apologies for the poorly written post but hopefully you understand what I am trying to get at. Thanks, Jack
Last updated: 2024-02-14

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19

Post by matthew on Persistence Manager Backup CODESYS Forge talk (Post)
Hi, Is there a process to restore Persistence Manager files? I have backups of persistence variables used in a machine that is currently operating and tuned and all set points adjusted. There are about 500 persistence variables, they are building another identical machine. I would like to use Persistence Manager files from the first machine in the second also. I have tried copying the files and replacing them on the new RPI but then the Persistence Manager gets errors and then they are all reset to 0 etc I have tried adjusting the times to match. Instead of replacing whole file, I tried just changing the contents inside the file, but still does not work. I may be missing something here, but surely there must be a way to load a backup. Thanks!
Last updated: 2023-10-18

Post by felipemsgarcia on Edge Gateway online, but PLC is not online CODESYS Forge talk (Post)
Hello, Up until yesterday (2023/11/20) I was able to connect to the PLC remotely with no issues through Edge Gateway. However, today I can see the Edge Gateway online but I can find the PLC even if I do a network scan. Following the same path as janber0206 @ https://forge.codesys.com/forge/talk/automation_server/thread/e78b11d7e9/, I looked into certificates and found that one of the Trusted publisher certificates has expired earlier today (2023/11/21). Please see image. Questions are: Does it affect the connection to the PLC through Edge Gateway? How do I fix it? Thank you very much in advance!
Last updated: 2023-11-21

Post by tomgr on Codesys 3.5.19 Control Win x64 - network adapter for EtherCAT master not working CODESYS Forge talk (Post)
Hi guys I am trying to run on my laptop Codesys 3.5.19 Control Win x64 where I created a EtherCAT master. I have defined the controler, specified network adapter (my docking station) and everything worked as expected. Later I needed to test it on site (without docking station) so I changed the network adapter by EC master to my laptop network card. After that it shows "Network adapter opened" but no device can be found by scanning and in LOG is saying "SysEthernet: packet could not be sent, error code: -1". Same error with USB network card, but if I switch back to docking station, all is working again... Any idea what I'm doing wrong?
Last updated: 2023-11-22

Post by seppi on Establishing communication between a Raspberry Pi 4 and an Arduino UNO R3 using I²C. CODESYS Forge talk (Post)
Hello everyone, I want to establish communication between my Arduino and my Raspberry Pi via I²C, but I have no idea how to make it work. However, it should work because there are many examples available, although none of them were programmed using Codesys, but rather using Python. My Raspberry Pi will be the master and is supposed to exchange measurement data such as speed and battery capacity with the slave (Arduino). I would be very grateful if someone could help me with my problem. Here is another link that could be helpful. However, I can't find the mentioned libraries
Last updated: 2023-12-03

Post by budd7566 on Text size suddenly changed CODESYS Forge talk (Post)
Iv been working with a Deep Sea Electronics DSE840 for about 6 months. I have a development version of my program working with a state machine and a basic gui interface. I went to implement CAN and suddenly the text on the gui on the controller is much larger than before. I could flash old versions of my project and the text was the correct size, but if i renamed the project file, the text displayed would be large. The visualization in CODESYS always shows the expected size, but not the controller. I did a fresh install of CODESYS and even a new project with only one text box, I cant get the text size on the controller to match what is displayed in codesys to match. Any advice?
Last updated: 2023-12-09

Post by vformanek on irq-set piority is not working in plc-shell CODESYS Forge talk (Post)
Hello, I am currently having issues on CODESYS Control for linux SL with DTH expiring. I have followed several tutorials of creating a proper RT linux. Then I further configured the linux based on this tutorial: https://content.helpme-codesys.com/en/CODESYS%20Control/_rtsl_performance_optimization.html Currently I am getting DHT expires in the communication and I am trying to increase of the priority of the network task which manages the PROFINET network adapter. I am following this tutorial: https://content.helpme-codesys.com/en/CODESYS%20PROFINET/_pnio_trouble_connection_failure.html But the irq-set is not changing the priority. See the image bellow....
Last updated: 2024-01-05

Post by riccardo on Error while processing the visualization: Client id not present or no longer valid CODESYS Forge talk (Post)
Hallo goodmorning, I am using codesys 3.5 sp19 with Weidmueller PLC. I created a page with several checkbox to manage an array of bool. When I build the project the system doesn't signal any error, when I go in simulation mode everything works until I click on checkbox to toggle the variables. Other visu elements works proprerly (e.g. bottons, lights, ect, ect) but the check boxes cause a crash giving the following error: Error while processing the visualization: Client id not present or no longer valid I serched to figure the problem out and to search a solution on the web but nothing. Can someone help? Thanks and Regards, Scanu
Last updated: 2024-01-23

Post by amy123 on codesys mqtt publish serialization CODESYS Forge talk (Post)
Hello, I am using the CODESYS IIoT Libraries SL MQTT Publish. Does this publish block only support publishing STRINGS as a readable format? I can publish ENUM, STRUCT, BOOL; however, MQTT Explorer will only display strings. When I use Wireshark, I can see that it is publishing something, but it looks to be publishing a serialized version which is a bunch of 0s or random text. If so, is there any way to deserialize this information back into a readable format? See pictures, where I have a BOOL TRUE that gets published as 001. Then see where I publish a STRUCT and it's an incomprehensible combination of 0s - only the string variable is displayed. Or, is it expected that you convert everything to a string before publishing? Any help is greatly appreciated! :)
Last updated: 2024-02-16

Post by nmcc on Viewing PDF in WebBrowser Visual Element CODESYS Forge talk (Post)
I am trying to show a PDF in a WebBrowser element. I have the file saved to the drive of the HMI/PLC. I am linking it in the URL parameter of the WebBrowser using the following directory link. 'http://localhost:8080/$$sdcard$$/FileName.pdf'. This allows for the program to download without any errors. When I navigate to that screen it is just a white box and nothing shows. I attempted putting the same link in the show parameter and I get a loading icon on my cursor when monitoring the HMI with my PC. Any help is appreciated. Thank you.
Last updated: 2024-02-29

Post by valenting on Runtime not working on raspberry pi Bullseye CODESYS Forge talk (Post)
Hello I have a problem with Codesys on Raspberry pi with Bullseye The device is not recognized as a Raspberry pi, as I get this error : ooops... this runtime was built for RASPBERRYPI. Hardware version or firmware version not supported! (-18, 0x00000BB8, 0xFFFFFFFB) I'm running Codesys on a compute module 4S with Raspbian GNU/Linux 11 (bullseye), my kernel version is Linux 5.10.90-v7l+ Codesys version is the latest, released last week (4.11.0.0, CODESYS Control V3.5.19.61 for ARM-32Bit - build Feb 22 2024) I know it works on the same device if I use Raspbian 10 (Buster) with Linux 5.4.81-v7l+ kernel, but for some other reasons I have to use Bullseye. What can I do ?
Last updated: 2024-03-01

Post by mp9876 on Problems with simulation in Window 10 CODESYS Forge talk (Post)
Hi Automa, it seems the solution you were bringing up on 2022-04-06 could really help me as I did not remember the password I initially set. My problem though is that I am using Codesys Control Win V3.5 SP19/60 (64 bit) and I cannot locate any of the files you listed up there. I have been looking inside folder: C:\Program Files\CODESYS 3.5.19.60\CODESYS\ and they appear not to be present at all neither in the CODESYS folder or any sub-folders. Uninstalling and re-installing unfortunately does not do the trick. Any idea how I could get out of the ditch on this issue ? Anyone else maybe ? Thanks
Last updated: 2024-03-18

Post by ragarcia on Error while using Codesys SP19 Patch 4 on Windows 11 CODESYS Forge talk (Post)
Hello everyone, I just installed Codesys SP19 Patch 4 on Windows 11 and every time I open Codesys I get an error that says (Attached image): 'One or more issues ocurred with the current versio profile. Please contact the vendor to resolve these problems. The plug-in {....} (Exactly 4.15.0.0) is required by the current version profile., but has not been installed. It is highly recommended that the tools is terminated. Do you wanto to terminate now?' I cannot install any package since I get this error everytime I open or try to install any package. Can someone help me please, thanks in advanced
Last updated: 2024-03-26

Post by wiresplus on How to Connect / Go Online without re-downloading the project CODESYS Forge talk (Post)
Hello, I have a PLC in a remote location. I can connect to it, but when I use a different PC, it asks me to re-download to the PLC - which will a) interrupt production and b) cause version issues. Codesys being open-source, if someone else has made changes, I need to be able to connect, upload the current project, compare it with mine and then decide what next. Every time I connect, it says Warning: An application 'Application' is currently in RUN mode on the PLC. As there is no matching compile information, this existing application needs to be replaced. Click 'Yes' to download the latest code or 'No' to abort. What am I doing wrong?
Last updated: 2024-04-13

Post by m83coding on Raspberry Pi Codesys SPI Master CODESYS Forge talk (Post)
Hello, I am trying to control shift registers 74HC596 and 74HC165 via Raspberry PI with SPI interface. So far I did it with a Microcontroller and now I wanna upgrade my Projekt with Raspberry Pi and Codesys Software to be more flexible. I tried to adapt PiFace Function Block to just send or recive a 8 bit via SPI interface of the my Raspberry Pi. With following code (see attached screenshots) * PLC_PRG * PiFaceDigital * PiFaceDigital.write8 * PiFaceDigital.read8 I have a signal at SCK and MOSI pin of the PI, so far so good. But I really struggle with the unterstanding of the code. Is there some detailed description of each line of code? Or is there somebody in the community who can explain each line of code? Or is there a more simple way to send / recive 8 bit via SPI? Manuel
Last updated: 2024-04-23

Post by garrian on How to sort JSON object in codesys CODESYS Forge talk (Post)
Hi there, I'm testing out MQTT from my Wago PLC using JSON object. I have managed to publish this {"Temperature":15.6,"Setpoint":38.0} to my broker. Now I', trying to subscribe to the same message. The result is this: '{"Temperature":15.6,"Setpoint":38.0}95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' First, why do I see 95}ê$10šå$04$Nå$08²Ÿå$0B` á$08@šå' at the end of the message? Second, how Can i sort out this data to use it in my program? I followed a youtube tutorial which gave me the attached result, which works. But I need some other smart way of doing this when the object gets even more data in it. Any help is very appreciated :)
Last updated: 2024-05-04

Post by fpawlak on KNX SL on stock PFC200 firmware CODESYS Forge talk (Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23

Post by ragarcia on How to change login visualization for other visualization after user logged in CODESYS Forge talk (Post)
Hello everyone, I have a web visualization on Codesys and to be able to use the web visualization first an user and a password is requested. After the user logged in, I want to automatically change the visualization to the 'Home' visualization but I am not sure how to do this. In the login visualization I basically have a button with the input configuration to execute the action 'Login' after a click. Once the user is logged in, the visualization is still stuck in the login page and I want to automatically change to Home visualization if the user was succesfully logged in. How can I know the number of web visualization clients connected to my PLC? Thanks in advance
Last updated: 2024-06-04

<< < 1 .. 28 29 30 31 32 .. 94 > >> (Page 30 of 94)

Showing results of 2335

Sort by relevance or date