Post by struccc on Release SP20 - Changes in behaviour?
CODESYS Forge
talk
(Post)
Dear all, I've just started to migrate some of my ancient projects to SP20. There is one strange error (?) I have noticed so far. In a method call, depending on the circumstances I would like to return reference to an object, or an invalid reference: METHOD Add_EVT_OUT : REFERENCE TO FB_MSG VAR END_VAR IF __ISVALIDREF(refMSG_Entry) THEN Add_EVT_OUT REF= MANAGER.AddMsg_EVT_OUT( refMSG_Entry, _Get_EVT_Message(MSG_EVENT.OUT), _Get_EVT_AddCode(MSG_EVENT.OUT) )^; ELSE Add_EVT_OUT := 0; END_IF So far setting a reference variable to 0, did this. But now, the expression Add_EVT_OUT := 0; gives an error: [ERROR] DB_WTP_370: Add_EVT_ACK MSG_TRIGGER_EXT: C0032: Cannot convert type 'BIT' to type 'REFERENCE TO FB_MSG' Naturally... I can write: Add_EVT_OUT := DWORD#0; But is this the correct way? Is there any constant I could use instead, like "NULL"? Or this is totally wrong and to be avoided?
Last updated: 2024-03-24
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
I have a Array of constant size defined like this Var Constant MAX_SIZE :UINT := 10; End_var VAR array : ARRAY[0..MAX_SIZE] OF INT; END_VAR Now I want to pass this array to a function by reference, Function fun : INT VAR_IN_OUT CONSTANT MAX_SIZE : UINT; END_VAR VAR_INPUT array : REFERENCE TO ARRAY[0..MAX_SIZE] OF INT; END_VAR but when I run this it gives strange Errors Error : Cannot Convert type 'ARRAY [0..MAX_SIZE] OF INT' to type 'ARRAY[0..MAX_SIZE] OF INT'
Last updated: 2024-01-07
Post by sunfloweeerrry on Edgelogix-rpi-1000-cm4102032 SPI port connection to PiFace I/O Driver in CodeSys.
CODESYS Forge
talk
(Post)
Please anyone help there is not a lot reference about this.
Last updated: 2023-08-21
Post by olemart on Set REFERENCE to 0 (null) when no longer used
CODESYS Forge
talk
(Post)
Did you find out if this work?
Last updated: 2024-10-02
Post by simotion on Property
CODESYS Forge
talk
(Post)
Why can't a property be of type REFERENCE TO? Plc goes to stop if I try that.
Last updated: 2023-12-14
Post by dkugler on Direct Pointers in IOMapping for EtherCAT with IoDrvEthercatLib.ETCSlave_Dia
CODESYS Forge
talk
(Post)
rmaas: how do you get the reference of the slave?
Last updated: 2024-02-13
Post by awatson on User Management - REFERENCE TO VisuUserMgmtProvider
CODESYS Forge
talk
(Post)
Hello Guys I have IFM CR1140 screens that I want to use the basic user management Elements on - But I am trying to figure out where I am going wrong with the References "REFERENCE TO VisuUserMgmtProvider" The Device will look after the security itself - I have enabled the User Management in Visualization Manager and added an admin user to the device and sync'd.
Last updated: 2023-11-17
Post by tvm on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
It will be a reference, because it's a VAR_IN_OUT. it's a little weird debugging the array online. It just shows as a POINTER TO INT, and you can't actually see the array from the function side. But you can still work with it as a normal array, not a pointer.
Last updated: 2024-01-09
Post by fpawlak on KNX SL on stock PFC200 firmware
CODESYS Forge
talk
(Post)
Hi All. Is it possible to use CODESYS KNX SL on stock Wago firmware (Codesys version, not e!Cockpit). I have Wago 750-8212 with firmware 0.4.04.03(26). When I tried to run 'KNX SL' or even 'Device Reader', I have got [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE3' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' [FATAL ERROR] Unresolved reference: 'CODEMGETCONTENTBYFIRMCODE2' What probbalby means that there is no running CodeMeter component on PLC. I have checked /etc/codesys3.d/CODESYSControl.cfg [CmpWebServer] WebServerPortNr=58080 [CmpSecureChannel] CertificateHash=86ccf31839a098ee32067179e26600f1bd6b36f8 [CmpUserMgr] AsymmetricAuthKey=a9d38381e75bbf1bbfc8749e97f536f68238a2ce So the question is if I can somehow add Codemeter to stock firmware? Or should I switched to CODDESYS Control for PFC200 SL or application-base runtime licence?
Last updated: 2024-05-23
Post by dclements on Feature Request: Read-Only References / Pointer-to-Const Support
CODESYS Forge
talk
(Post)
I would like to suggest adding support for persistent read-only references or pointers in CODESYS, similar to a C++ pointer-to-const (const T*). For example, something conceptually similar to: POINTER TO CONSTANT ST_MyData or REFERENCE TO CONSTANT ST_MyData The important distinction is that the reference itself may still be passed around or reassigned, but the referenced object cannot be modified through that reference. CODESYS currently supports VAR_IN_OUT CONSTANT, which provides read-only reference semantics for parameters, but there does not appear to be an equivalent type that can be stored in a variable or returned from a method. A practical use case is a registry that owns long-lived definitions. The registry needs to retain ownership of the data while downstream systems maintain persistent references to it. Currently, the main options are: Return the struct by value, which loses reference semantics and requires a copy. Return POINTER TO ST_Definition, which allows consumers to modify registry-owned data. Convert the structure into a Function Block and expose a getter-only interface, which provides the desired encapsulation but introduces more complexity and memory overhead. A read-only reference/pointer type would allow libraries to expose persistent, zero-copy access to internally owned data while preserving encapsulation. This would be particularly useful for library APIs and object-oriented CODESYS architectures where ownership of data should remain with one component while other components are allowed to observe it. Similar requests for constant references/pointers have been discussed on CODESYS Forge previously, so this appears to be a recurring use case rather than something specific to one application.
Last updated: 2026-09-01
Post by macros8 on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Hi all, I need a help. I want to create Frame where some parameters are done via reference input to this frame. What I have realized that if I use for Label/Caption etc. string variable (%s) it is not included in translation list. This is a quite a big deal and I did not find way how to add text to the list manually. Would you give me a hint how to proceed? I hope there is a way (workaround) how to do it. Thanks a lot. M.
Last updated: 2023-12-01
Post by timvh on Troubles with using CAN API
CODESYS Forge
talk
(Post)
In the example project, you can see that a CAN.CANAreaReceiver is used which has an VAR_IN_OUT reference to a RECEIVER_AREA structure. This structure has a dwIdStart and dwIdEnd to filter a range of ID's and process them through the referenced msgProcessor.
Last updated: 2023-09-19
Post by tvm on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
Use a VAR_INPUT for properties. The reason for the error is that you can't get a reference to a property. Using a VAR_INPUT will copy the property to an input variable.
Last updated: 2025-03-06
Post by felipemsgarcia on Axis EtherCAT address
CODESYS Forge
talk
(Post)
Hello, I'd like to write some parameters to axes from inside a function block where I passed axis by reference, using ETC_CO_SdoWrite. Is it possible to get the device address from inside the function block? Please see example below. Thank you!
Last updated: 2025-03-06
Post by avenue68 on REFERENCE TO in an array
CODESYS Forge
talk
(Post)
That's because the array only contains structures themselves, not references. It doesn't matter that what consists of each struectures unless they are not pointers.
Last updated: 2025-05-21
Post by thomasfrank on TCP Server
CODESYS Forge
talk
(Post)
You can use function blocks like TCPServer to start the Retro Bowl College server and TCPAccept to handle incoming connections, with CAA.Handle simply acting as a reference ID for each resource.
Last updated: 2025-06-03
Post by timothyzalusky on Missing Device Descriptions in Repository
CODESYS Forge
talk
(Post)
For reference this is fixed by installing the new codesys install with a separate repository folder. Completely resolved. If anyone else sees this. I would like to know why the persistent devices repository folder does not properly retain between installs though.
Last updated: 2025-06-12
Post by timothyzalusky on Missing Device Descriptions in Repository
CODESYS Forge
talk
(Post)
For reference this is fixed by installing the new codesys install with a separate repository folder. Completely resolved. If anyone else sees this. I would like to know why the persistent devices repository folder does not properly retain between installs though.
Last updated: 2025-06-12
Post by timothyzalusky on Missing Device Descriptions in Repository
CODESYS Forge
talk
(Post)
For reference this is fixed by installing the new codesys install with a separate repository folder. Completely resolved. If anyone else sees this. I would like to know why the persistent devices repository folder does not properly retain between installs though.
Last updated: 2025-06-12
Post by rckalex on Adjusting Ethernet Settings from Visualization
CODESYS Forge
talk
(Post)
Could someone please share reference documentation for interacting with a device's IP settings from a visualization/webvisu? Is what is outlined here still valid? https://forge.codesys.com/forge/talk/Engineering/thread/ad11c199a2/
Last updated: 2025-06-26
Post by sharer on Recipe Manager - RecipeManCommands, load & write wrong values, Bug?
CODESYS Forge
talk
(Post)
With reference to the release note for "CODESYS Recipe..." from CoDeSys (https://www.codesys.com/ecosystem/release-lifecycle/releases-updates/recipes/). After updating that software module to v4.6.0.0 on CoDeSys 3.5.21.1 I am no longer able to reproduce the problem.
Last updated: 2025-09-16
Post by marekxc on Translation - How to get text as reference in Frames translated?
CODESYS Forge
talk
(Post)
Show a simple example of what you're doing. What and where are you changing? Maybe this link will be useful to you" https://content.helpme-codesys.com/en/CODESYS%20Visualization/_visu_using_visu_as_element.html
Last updated: 2023-12-29
Post by apurv on Cannot pass array of constant size to a function as a reference
CODESYS Forge
talk
(Post)
Could not find the solution to this issue but I have side stepped this by creating a global variable MAX_SIZE.
Last updated: 2024-01-08
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I put the cross reference at the bottom of the pictures. It is not being written to elsewhere. I have tried the execute block too.
Last updated: 2024-01-26
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I put the cross reference at the bottom of the pictures. It is not being written to elsewhere. I have tried the execute block too.
Last updated: 2024-01-26