Post by john-martin on Control SL Extension Package doubts CODESYS Forge talk (Post)
Hello everybody, I'm trying to understand the SL control extension package, more specifically, the external IODriver example, because C integration is very easy and I just made my first C component successfully. Ther External IODriver has no documentation and it's not clear how to proceed. Furthermore, there is no information on how to modify the device descriptor, which is necessary to import the device into the Codesys repository. Any advice ? Thank you in advance and best regards.
Last updated: 2024-02-28

Post by elektron785 on Dongle von Linux-Modul (ARM64) nicht erkannt CODESYS Forge talk (Post)
Die Ausgabe bei lsusb ist im ersten Post im Bild usb.png zu sehen - der Dongle wird als WIBU Systems CmStick erkannt. Um Codesys als Soft-PLC darauf zum laufen zu bekommen habe ich das Addon Codesys Control for Linux ARM SL installiert und mir einen Docker gebaut mit den Dateien: codesyscontrol_linuxarm64_4.10.0.0_arm64.deb und codemeter-lite_7.60.5625.503_arm64.deb Wenn ich den Docker ausführe sind die beiden Programme ja inbegriffen und Codemeter sollte eigentlich die Erkennung des Dongles sicherstellen. Gibt es eine Möglichkeit festzustellen, dass Codemeter korrekt ausgeführt wird?
Last updated: 2024-09-05

Post by eschwellinger on Changed Device of Rapberry Pi to MC SL instead of standard SL and cannot connect anymore CODESYS Forge talk (Post)
1) https://store.codesys.com/en/codesys-control-for-raspberry-pi-sl.html -> SL: Restrictions The combination of Raspberry Pi and a CODESYS Runtime is for private use, test and teaching purposes. Commercial use is not permitted. 2) you could switch between them by /etc/codesyscontrol/CODESYSControl_User.cfg [CmpRasPi] Architecture=armv7l for MC: armv7l for SC: armv6l for 64Bit: aarch64 or in the Deploytool:
Last updated: 2025-08-06

Post by manuknecht on Using an Axis of an Axis Group in Torque Conctrol CODESYS Forge talk (Post)
I don't seem to be able to use an axis, which is part of an Axis Group in torque control mode. I call the SMC_SetControllerMode FB to switch from position to torque control mode, followed by the SMC_SetTorque FB to set the desired torque. This works flawlessly for most axes, however if an axis is part of an axis group, switching the controller mode seems to work without any issues, but the desired torque is never set. SMC_SetTorque does not return an error, but fSetTorque of the axis is never changed. Disabling the axis group before does not change anything, but if I use MC_UngroupAllAxes before changing the controller mode, it all works as it should. Is there no way to control a single axis in torque control, if it is part of an axis group?
Last updated: 2025-07-17

Post by ranadheer on PHOENIX CONTACT Axioline PLCnext project in CodeSys SodftPLC CODESYS Forge talk (Post)
Thank you Pernockham, I am using Windows SoftPLC and the device is CODESYS Control Win V3 x64. In the above attached example, the file is Linux-based. This is an external add-on file in the CODESYS installer (CODESYS Control for PLCnext SL). I am trying to implement it without this add-on file.
Last updated: 2025-09-09

Post by dhumphries on Control Runtime Toolkit CODESYS Forge talk (Post)
I have a video demonstrating the procedure to install the runtime on a linux device. https://youtu.be/rj0dOhgnGjs?si=OJoA-kgc1saxIweR This demonstration shows how to install the runtime on a X86 based controller, it should be the same for an ARM based device, but you'll need to install the add-in for Codesys control for Linux ARM SL (or the 64 bit add-in.)
Last updated: 2023-12-30

Post by dhumphries on install codesys runtime on linux CODESYS Forge talk (Post)
Adding the command worked. I was able to deploy the runtime on an ubuntu server installation. Thanks!
Last updated: 2023-11-04

Post by eschwellinger on TargetVisu on Raspberry? CODESYS Forge talk (Post)
install this: https://store.codesys.com/de/codesys-targetvisu-for-linux.html via CODESYS Installer and deploy it by update command
Last updated: 2024-07-26

Post by eschwellinger on Update Raspberry Pi option is missing under Tools menu CODESYS Forge talk (Post)
The new Deploy Tool 4.14.0.0 contains all devices. Raspberry PI virtual plc etc.
Last updated: 2024-12-13

Post by eschwellinger on No Visu on RasPi CODESYS Forge talk (Post)
..on 4.12.0.0 release there it will be possible to deploy RemoteTargetvisu which is what you expect now. (next week)
Last updated: 2024-06-20

Post by eschwellinger on search runtime 4.9.0.0 for pi 3 CODESYS Forge talk (Post)
runtime could always be in latest version. just keep everything in CODESYS stable and deploy the latest runtime. This will work.
Last updated: 2025-10-25

Post by chris12345 on IO-Link Lizenz CODESYS Forge talk (Post)
Moin, IO-Link läuft nur 30 Minuten im Demo Modus. In meinem Fall, brauch ich zusätzlich zur "CODESYS Control for Raspberry Pi MC SL" diese Lizenz :- https://store.codesys.com/de/codesys-io-link-master-for-el6224-sl.html Gruß Chris
Last updated: 2023-10-11

Post by eschwellinger on Migration von "CODESYS Control for PFC200 SL" zu WAGO FW26 "CODESYS V3.5.19.2" CODESYS Forge talk (Post)
Ich fürchte fast, das musst du mal an den Wago Support adressieren.. oder vielleicht ließ hier einer mit?
Last updated: 2023-11-17

Post by ggis on Rasperry Control Debian 12 CODESYS Forge talk (Post)
From bash I usually see codesyscontrol.service as the runtime service. Taking a step back, I guess you used Tool > Update RaspberryPi SL interface to install the runtime: what does the info popup window tells you about your destination system?
Last updated: 2023-11-26

Post by damian177 on Codesys Control for Linux SL CODESYS Forge talk (Post)
In /etc/CODESYSControl.cfg I only added: [SysCom] Linux.Devicefile=/dev/ttyS Is ok ? Now in Codesys I should have mapping like below : COM1 - ttyS0 COM2 - ttyS1 ?
Last updated: 2024-09-08

Post by dangjoris on raspistepper error after install CODESYS Forge talk (Post)
Ok with the new Release of SM3RaspiStepper 0.0.0.6 it is fixed. Everything works fine with CODESYS Control for Raspberry Pi SL 4.13.0.0 and CODESYS SDK 3.5.20.20
Last updated: 2024-09-30

Post by dangjoris on Missing function for ConfigGetParameterValueBool (SM3RaspiStepper) CODESYS Forge talk (Post)
Ok with the new Release of SM3RaspiStepper 0.0.0.6 it is fixed. Everything works fine with CODESYS Control for Raspberry Pi SL 4.13.0.0 and CODESYS SDK 3.5.20.20
Last updated: 2024-09-30

Post by albertocamina on Login problem with FileTransfer on Raspberry Pi 5 CODESYS Forge talk (Post)
Dear eschwellinger, sorry for the late repply. Just saw your answer nor. We are using: -CODESYS V3.5 SP19 Patch 2 -Compiler version - 3.5.19.20 -Visulaization Profile: 4.6.0.0 -CODESYS Control for Raspberry Pi 64 SL 4.12.0.0 All the best!
Last updated: 2024-10-23

Post by winki on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
I do not have error anymore using nic with eth0 value. But my network it still 172.17.0.3 like the first picture.
Last updated: 2024-10-23

Post by tmo21 on Automation server - trends stop recording - need to manually reconnect CODESYS Forge talk (Post)
Hi Edwin, Thanks for your message. Edge controller Version: 4.4.0.0 based on 3.5.17.30 PLC version: Device Identification Name CODESYS Control for Raspberry Pi MC SL Vendor 3S - Smart Software Solutions GmbH Device type Softmotion3S Firmware version 4.4.0.0
Last updated: 2024-10-23

Post by timvh on Modbus TCP & RTU with Control for Linux SL CODESYS Forge talk (Post)
Most likely your IP address is set to 172.... because you use a VPN connection to your device. Probably best to use the other Ethernet interface for your modbus communication.
Last updated: 2024-10-24

Post by rh-cs-234 on Codesys Tools Update Raspberry ist nicht vorhanden aktualisieren im Geraete ansicht geht auch nicht CODESYS Forge talk (Post)
Hallo Daniel, da wurde in der Runtimeversion 4.14.0.0 etwas geändert. Du findest jetzt die Funktion zum Updaten des RasPis unter Tools/Control Sl ausrollen Grüße Reinhard
Last updated: 2024-12-13

Post by eschwellinger on Not Possible to connect using control SL CODESYS Forge talk (Post)
should work, could you please check on the target: top if the the gateway is running -> you should see codesysedge.bin and cat /var/opt/codesysedge/codesysedge.log
Last updated: 2025-01-07

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Thx for your help, I just Uninstall and install again codesys. I did it as admnistrator and now it is working... I did not change anything into the target configuration. Only my codesys on my computer. Loic,
Last updated: 2025-01-10

Post by winki on Not Possible to connect using control SL CODESYS Forge talk (Post)
Thx for your help, I just Uninstall and install again codesys. I did it as admnistrator and now it is working... I did not change anything into the target configuration. Only my codesys on my computer. Loic,
Last updated: 2025-01-10