Post by imdatatas on TO_STRING operator not working for IMPLICIT ENUM
CODESYS Forge
talk
(Post)
Hi Everyone, It is a very useful feature to be able to obtain the enum value as a string with the TO_STRING operator by defining {attribute 'to_string'}. However, unfortunately the same function does not work for IMPLICIT ENUMs. I hope that {attribute 'to_string'} behavior can also work for Implicit Enumeration data types in one of the upcoming Codesys versions. https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_pragma_attribute_to_string.html https://content.helpme-codesys.com/en/CODESYS%20Development%20System/_cds_datatype_implicit_enumeration.html Best regards, Imdat
Last updated: 2025-03-27
Post by andrej on Creating, using an external Function.
CODESYS Forge
talk
(Post)
Hello all, could you tell me whether I need an additional license in order for v3x64 to execute the DLL? Is there some manual on how to proceed? Other than the rather generic message loading Component failed Lib_XMATH.dll I have no further hints. Many thanks for your feed back. PS: I tried a similar experiment (i.e. generating a native dll for windows and having it executed by the Python VM this worked without an issue).
Last updated: 2025-05-05
Post by sercan on Connecting Parameter 'A' in G-Code to Physical Axis in CNC Project
CODESYS Forge
talk
(Post)
I want to run the following command by linking it to the A-Axis: G01 A45.0 Which TRAFO should I use to do this? SMC_TRAFO_5Axes and SMC_TRAFO_GantryCutter3 function blocks did not work! For example, when SMC_TRAFO_5Axes is used, parameters B and C can be resolved by the transformer. However, parameter A cannot be resolved. Only SMC_Interpolator displays the value of parameter A in the SMC_Interpolator => piSetPosition.dA output. Should I drive this axis with SoftMotion commands (MC_MoveAbsolute etc.)?
Last updated: 2025-05-07
Post by nz-dave on Custom library, ethernet/ip adaptor
CODESYS Forge
talk
(Post)
Im Putting alot of my custom functions blocks into a library I have a EthernetIP VSD FB that i would like to get Status from the adaptor. EthernetIP_remote_adaptor.estate is one what i want to get. so anyone know how to point that to my function block? when i use the block i just want to have an input "Drive" that would point to the adaptor. like in softmotion when you just put the axis name in the FB to point the FB to a certain axis. Hope that makes sense, cheers
Last updated: 2025-05-21
Post by romrot on MS SQL Compact cutting off Database name?
CODESYS Forge
talk
(Post)
I'm trying to use an fbMsSQL_compact function to read data from an SQL database. It works with some databases, but there is one database that I can't seem to get it to work on. It's set up the same as the other databases that I've tested with the only difference I see is that the name of the database is cut off in the status message. I'll get a message like "User: User logged out succesfully from database: 12345" But the whole name of the database is something like 1234567.
Last updated: 2025-08-21
Post by sandro66 on Application-based license Modbus Channels
CODESYS Forge
talk
(Post)
Hi Gatto, Using version 3.5.21.xx, it is no longer possible to use Modbus function blocks (I make extensive use of these FBs.)as shown in the example. https://content.helpme-codesys.com/en/CODESYS%20Examples/_ex_modbus_example.html The compiler detects one Modbus instance for each instance of the communication FB block. The example program above, although simple, reports 8 Modbus instances when compiled with the latest version. Codesys Support says that you must use fieldbus I/O mapping, but this will result in the loss of the ability to programmatically modify communication parameters. Sandro
Last updated: 2025-09-04
Post by bmatlove on AXIS_REF_SM3 Error Codes?
CODESYS Forge
talk
(Post)
I'm trying to firm up alarming of axis faults. Declutter the code and figure out what's what. Diving into it, I see the AXIS_REF_SM3 function block provides uiDriveInterfaceError and dwErrorId, but I can't find any significance of these further than Drive interface error number Parameter number: 1014 and Drive specific error identifier, parameter number: 1031, respectively. Is there some corresponding appendix I could use to decode these? Also, is there any relation to the Error ID (of type SMC_Error) of the MC POUs? MC_Jog, MC_Reset, MC_MoveRelative, etc? If so, are the above errors redundant? Thanks in advance.
Last updated: 2025-09-22
Post by nathant on Some visualization objects disappear when user is logged in?
CODESYS Forge
talk
(Post)
I am deploying a webvisu on Codesys 3.5 SP 19.2 with legacy user management. I noticed that when a user logs in, some text and a rectangle I have (for aesthetics) both disappear. I made sure that none of the objects in question are linked to a state variable. Anyone know the cause/solution to this? Nothing crucial to the machine's function is lost, but it is a little annoying.
Last updated: 2023-12-15
Post by paro on Client Independent Visualization Switching
CODESYS Forge
talk
(Post)
Hi, can you please provide a new example for the topic at CODESYS "Client Independent Visualization Switching" https://forge.codesys.com/prj/codesys-example/client-independ/home/Home/ Since a few versions, the functions used cause warning messages. Examples for the use of all function blocks from the Visu Utils would generally be very helpful! Several people have put together an example here: https://forum-de.codesys.com//download/file.php?id=2240 BR Patrick
Last updated: 2023-12-20
Post by wiresplus on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
Hello, I need to take an INT input, and convert it to a WORD value. VAR DRV2Speed : WORD; //IO card takes a WORD where 16000 = full 10V output (equivalent to 50Hz) PumpFillSpeed : INT; //Users enter a value between 0 and 50 END_VAR IF <conditions> THEN DRV2Speed :=INT_TO_WORD((PumpFillSpeed/50)*16000); END_IF </conditions> According to me this should work - but it stays at 0, no matter what. What am I doing wrong?
Last updated: 2024-01-26
Post by ojz0r on INT_TO_WORD function not working
CODESYS Forge
talk
(Post)
That calculation will not work the way you expect it to. If PumpFillSpeed is limitied to 0-50 then the only whole number would be 50/50 = 1 everything else is 0.0-0.9999... and since you are using word and integer only 50 would work since there is no representation for mantissa in integer values. Declare a temporary real variable and do the calculation and then do a REAL_TO_WORD in the DRV2Speed assignment.
Last updated: 2024-01-26
Post by thomas-moba on "sudo"-Befehle über die Funktion "SysProcessExecuteCommand2"
CODESYS Forge
talk
(Post)
Hello, I need to execute "sudo" commands via CoDeSys 3.5 SP 19 P5 using the "SysProcessExecuteCommand2" function. Commands without sudo are no problem, but as soon as sudo is used in a .sh or a single command, it does not work. Command=AllowAll is entered under "SysProcess" in CODESYSControl.cfg. Nevertheless it does not work. Does anyone know what the problem could be? Greetings, Thomas
Last updated: 2024-02-01
Post by kleeswi on SysFileOpen does not work after update to V3.5 SP19 Patch 5
CODESYS Forge
talk
(Post)
I use the function SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_WRITE, pErrorFileOpen); to open and write a file. Since the update from Codesys V3.5 SP17 to V3.5 SP19 Patch 5 it does not work anymore. I first had SysFile.SysFileOpen(sFileNamePara, SysFile.ACCESS_MODE.AM_APPEND_PLUS, pErrorFileOpen); in both versions. hFile_Test is a pointer to byte. It gives an exceptional error when dereferencing the hFile_Test pointer. Edit: I use Codesys on a Raspberry pi
Last updated: 2024-02-19
Post by andrej on POU - Access to runtime
CODESYS Forge
talk
(Post)
Hello all, when creating a POU, the Codesys IDE allows the setting "Enable System Call" (in the Settings, Property -> Build), see picture. The name suggest, that runtime functionalities i.e. functions of codesyscontrol such as "stop plc" etc. can be directly called. I tried various approches without success, the following does, unsurprisingly not work. FUNCTION accessRTE: BOOL; ****************************** codesyscontrol.stop(); Can you please tell me how I can make a system call to codesyscontrol from a POU. Or could you provide me with a use case for this setting. Many thanks for your feedback and kind regards Andrej
Last updated: 2024-03-02
Post by ofey on EtherCAT fieldbus
CODESYS Forge
talk
(Post)
Okey, thank you! Do you think it is something in this library, that makes it possible to do the configuration in a PRG? https://content.helpme-codesys.com/en/libs/IODrvEtherCATDriver/Current/IoDrvEtherCAT.html#id1 I think the codesys modbus libraries support configuration and connection to modbus slaves without having to add the slave devices in the device tree. Just do it from function blocks inside the program. I was hoping for something similar with EtherCAT.
Last updated: 2024-04-10
Post by gseidel on CNC - system goes to X=0 Y=0 before CNC file execution starts, how to avoid that?
CODESYS Forge
talk
(Post)
Hi peterned, the start position given in the CNC properties is only used if you use the compile mode OutQueue. With compile mode SMC_CNC_REF, you need to provide the start position in the IEC application. The function block SMC_NCInterpreter has an input piStartPosition. You can initialize it with the output of the forward kinematic transormation FB for your machine. In your case probably SMC_TRAFOF_Gantry2. Best regards, Georg
Last updated: 2024-04-30
Post by plunje on Sensor not set
CODESYS Forge
talk
(Post)
A got a larger project but this very small example makes it clear. I have a button, and after it's clicked a lamp should flip on and stays on, and when the mouse-button is released it should stay on. When I try that in the PLC_PRG it works, but when I change it to a function block (seet attched demo proj) it isn't. I'm fairly new to PLC programming but are very experienced C# engineer, but this goes above my head...
Last updated: 2024-05-26
Post by joep on Custom robotics kinematics model debugging
CODESYS Forge
talk
(Post)
When trying to move my axis using any group move instruction I get the following error: SMC_CP_INVALID_PATH_ELEM and axisgroup goes into errorstop state. I tested my methods thoroughly which makes it hard for me to debug. Are there some hidden rules I need to abide to? How would one go about debugging a custom robotics model, since the information inside isn't accesible. Is it possible to find the source of where the function breaks? Any hint in the right direction would be appreciated. Best regards
Last updated: 2024-06-08
Post by timvh on OSCAT Scale_r function not working in LD 4.60 works in LAD2 on 3.5.21sp3
CODESYS Forge
talk
(Post)
It seems like a bug in FBD. Work-around: If you click on the small line between the box and the output variable and delete this, the variable is removed. When you then assign a variable again (Ctrl-A), then you will see that the line will be a bit longer. If you then select the previous variable, you will see that it works.
Last updated: 2025-10-26
Post by rossanoparis on After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working
CODESYS Forge
talk
(Post)
Hello at all. After un upgrade of "CODESYS Control for Raspberry Pi MC SL" from v4.7 to v4.9 SysFileOpen function stopped working. I'm not able to read or write files from the PLC application. Before this upgrade all worked fine. I've read this thread [ https://forge.codesys.com/forge/talk/Engineering/thread/3da9ded84e/ ] Despite I followed that indications I couldn't get my code working again. Perhaps I'm missing something or I didn't understand how to use placeholders at all. Is there a different syntax to use for "SysFileOpen" in order to use placeholders? Thanks in advance for your help. Information Compiler: CODESYS V3.5 SP19 Patch 2 Runtime: codesyscontrol 4.9.0 HW: KUNBUS RevPi Connect S Below the paths I want to access (The entire CODESYSControl_User.cfg file is attached) [SysFile] PlaceholderFilePath.1=/home/pi/hpca/bin, $hpcabin$ PlaceholderFilePath.2=/home/pi/hpca/cfg, $hpcacfg$ PlaceholderFilePath.3=/home/pi/hpca/logs, $hpcalogs$ PlaceholderFilePath.4=/home/pi/hpca/resources, $hpcares$
Last updated: 2023-08-22
Post by sturmghost on Visualization using methods and cyclic ST-calls
CODESYS Forge
talk
(Post)
Im looking for a way to implement ST-code into the visualization element without creating a helper POU or method in my device/application tree. Like visualization properties are evaluated at each VISU_TASK cycle I want to be able to create own ST code which interacts with the visualization interface variables. To be more specific I want to have a property which executes user defined ST-code at each VISU_TASK cycle exactly like its already possible for Input Configuration on various mouse and dialog events. Also a property for initialization (so only executed once) and a timed property would be nice. With the situation right now I'll have to create a POU function which handles the ST-code and misuse a property, like the text variable, to execute this POU function at each VISU_TASK cycle. Or does it exist and I don't know it?
Last updated: 2023-10-02
Post by julianramirez on ModbusFB write update
CODESYS Forge
talk
(Post)
Hello everyone, I am testing the ModbusFB library tcp server and so far I am able to create holding registers successfully, however, I am trying to identify after each write which registers got updated (i.e. function code, write value). I can even see the var udiNumWriteRequests, which increases with every write. I noticed that there is logging with the LogStatusInfo method. After I call it I am able to read in the console stuff that I want. Nevertheless, this is only available at the logs and is not easy to decode because it consists on several messages, I would like to know if there is a way for me to retrieve this information from the function itself with pointers or if there is any way to copy the logs messages (assuming that I can filter them with the LoggingOptions to only show what I need) inside the runtime code and not in the console. Thanks for your help :)
Last updated: 2024-09-16
Post by hyys12 on Help understanding analog in-/outputs
CODESYS Forge
talk
(Post)
Hello. I am currently working on a WAGO PLC, where I am trying to wrap my head around how the analog inputs and outputs work in codesys. I have looked far and wide on the internet, for a general introduction to the whole concept, but I have not had any luck with finding anything that helped me understand it better. The whole goal is for me to be able to read an analog input from a temperature sensor, as well as using an analog output, to control a frequency inverter. I know these have nothing to do with each other, but that is all I have on hand right now. I am trying to program this using Ladder Diagram. The only thing is, that every video/guide I have seen/read using LD, just adds a whole lot of function blocks, to do all kinds of stuff they don't explain. My general question is, how would one go ahead and read the analog input, as well as transmit an analog output? Is there some kind of specific function block I would have to use for this, or some great video I can watch, to understand the inner workings. Is it somehow possible to see the values the PLC recieved/sends? Regards.
Last updated: 2024-12-11
Post by trusty-squire on Strange problem with the ‘MC_SetPosition’ function
CODESYS Forge
talk
(Post)
Here, it seems to me that we are getting completely off track with the observed problem. If questions clarifying the details of the installation are problematic, it's best to include those details in the original question then... I had already written this elsewhere. The program before being brought into machines was exhaustively tested in SW emulation and the problem did not occur. Testing the full program in emulation is entirely different from creating a simplified program to isolate the function causing problems in the real world. I would recommend trying it to isolate the issue. The drive and motor have been working fine for about 10 years. In replacing the machine control system, I opted for CoDeSys where before there was something else. But this is not the subject of the problem A simple "yes" is the correct answer to my question here... Anyways, you seem to be a very knowledgeable expert, good luck on your problem!
Last updated: 2025-01-18
Post by atcprojectteam on Modbus Function Code 15, writing multiple coils
CODESYS Forge
talk
(Post)
Hi all, I am using an RSTI-EP I/O card along with the EPXMBE101 Modbus/TCP network adapter. I have a Control Standard L license. I successfully connected to the I/O card via Modbus and can read inputs without any issues. However, when I try to write to the digital output modules using function code 15, I am unable to make any changes. Here’s what I have done so far: I created a small project using Structured Text. I set up Modbus channels (as shown in the attached image) and mapped the pins. When I use cyclic mode, the connection results in an error. However, when I use the rising edge, the connection works, but I don’t see any changes on the I/O card. For the output module, I assigned one bit to high. After that, I ran CODESYS Control Win V3. (Should I be running the PLC as well?) I built the program, but I am not receiving any response from the I/O card. Could you please advise on what might be causing this issue?
Last updated: 2025-02-26