Post by wedahitha on Could not open library 'SysSocket23, CODESYS Forge talk (Post)
Hi there, I am trying to open a codesys project done by someone else and Once I install all the libraries I get this error [ERROR] : Library Manager [PROJECT 01: PLC Logic: Application]: Could not open library 'SysSocket23, * (System)'. (Reason: The library 'SysSocket23, * (System)' has not been installed to the system.) SysSocket23 is a standard library and I also tried using the same OSCAT library which was from the original computer that made this code. Using CODESYS V3.5 SP18 Patch 2 Please help me how to solve this problem.
Last updated: 2023-12-19

Post by rpostwvu on Shared Memory Access Issues CODESYS Forge talk (Post)
I got the shared memory example. I'm pretty sure I'm successfully created a memory space, CreateResult returns 18. szName:='CodesysDataShare'; hShm := SysSharedMemoryCreate(szName, 0, ADR(uxiSize), ADR(CreateResult)); I'm trying to access this memory with a C# application, but I get "Unable to Find Specified File". I suspect that Codesys and/or Visual Studio code alters the name I choose? Being in Windows, I cant find a way to see the mapped memory list. ~~~ using (var mmfRead = MemoryMappedFile.OpenExisting("CodesysDataShare",MemoryMappedFileRights.ReadWrite)) ~~~
Last updated: 2024-01-29

Post by riccardo on Web Browser special tools errors CODESYS Forge talk (Post)
Nano goodmorning and thanks for the reaply, the links I have to manage are links as the following: https://192.168.1.101/u-os-app-codesys/application/visualization/webvisu.htm I saw that with Wikipedia or other web sites the tool works but not the link above. "google and some other providers, prevent from using as iframe and similar injections." The goal I'm pursuing is to display remote graphical user interfaces from a local graphical user interface over a local network. thanks in advance, Riccardo
Last updated: 2024-03-06

Post by niallel on How to change bHiresMode CODESYS Forge talk (Post)
Hi, I'm trying to get Scaling working on my axis. An increment produces 36.6mm of movement, so I want to put the units in application as 36.6. However the docs say that I need to change bHiresMode as it doesn't show me the option for Precision in the User Interface. I'm thinking that I need to change the precision so I can enter decimal places. How can I do this, or is my thinking wrong? Thanks,
Last updated: 2024-03-11

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, When I try to install my codesys program with the new application-based licensing, I have an error "it exceeds the scope of the license agreement. See Device > Licensed Software Metrics" In the Licensed Software Metrics section, I see a code size < 3MB and less than 2700 variables in visualiaztions. I'm using a license "Control Basic L" with "Codesys Visualization L" option, so it should be enough with these metrics. What can I do ?
Last updated: 2024-04-22

Post by valenting on Problem with Licenced Software Metrics CODESYS Forge talk (Post)
Hi, I tried with another project, using codesys SP20 with the latest visualization installed, I can install the application on my device but it doesn't work I get an exception "invalid license metrics" and the app won't run See attached the metrics in project and allowed by license, and the logs What am I supposed to do ? Everything is in the newest version and the values are lower than allowed and nothing works...
Last updated: 2024-04-26

Post by micik on CAA File, how to check whether file exists or not CODESYS Forge talk (Post)
Hello, what would be the most efficient way to check whether the file exists or not. I don't want to use file.Open function, it seems like rather inefficiet operaton. I considered GetAttribute function, but this function doesn't accept filename (with path) as an input. Basically I need to check first time when program is loaded to the runtime i.e. when application is started for the first time, whether a file exists on the specific location or not.
Last updated: 2024-05-16

Post by installwhat on What is the solution for "Application stopped on recovery switch request"? CODESYS Forge talk (Post)
<Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:47" infoId="1">Axis#=121 , Error=30014 , Emergency 2 <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : WaitClient <Entry severity="information" component="<10>" user="nobody" timestamp="2024-07-04 ?? 5:10:23" infoId="1">TCP Server : Init What is "component="<10>"? Is this system a vanilla CODESYS RTE or is it a modified installation. I think more details are required.
Last updated: 2024-07-08

Post by nano on Issues with Modbus Slave with Raspberry Pi CODESYS Forge talk (Post)
in the codesyscontrol.cfg or codesyscontrol_user.cfg you have to declare whoch comport-ports from runtime are used. please tell us how the comport is called in linux an post the codesyscontrol.cfg files also write down here, which parameters are used in the python-script and what is parameteized in the modbus-master-comport of your codesys-application. mostly the errors occurs in ine of these areas
Last updated: 2024-07-11

Post by gepert on parker servo and position CODESYS Forge talk (Post)
Hello, Thank you for your response. In my application i use ethercat and while work i do not turn off power. After relative move motor is in standstill. As you suggest I suppose that problem is in drive setting but i do not see any option about increase standstill torque. Below i posted some photos from drive setting manager - PSD Servomanager Do you see any settings responsible for standstill torque? thank you
Last updated: 2024-08-05

Post by joep on overruling kinematic limits of [-90°, 90°] in bipod_rotary CODESYS Forge talk (Post)
Hi All, for my robotics application we are building a 2-axis parallel scara using the kin_bipod_rotary kinematics. Codesys implemented limits of [-90°, 90°] according to the documentation: https://content.helpme-codesys.com/en/libs/SM3_Transformation/Current/SM3_Transformation/Function-Blocks/Positioning-Kinematics/Parallel-Systems/Kin_Bipod_Rotary.html Would it be possible to overrule these limits somehow, our mechanical limits are more in the range of [-110°, 135°] In this range we also don't encounter point where singularity is an issue. Hopeful someone knows a solution, Best regards, Joep
Last updated: 2024-09-04

Post by naps on Welchen I-Port benötige ich? CODESYS Forge talk (Post)
Hallo, ich versuche eine 750-653(konfiguriert per iocheck) über die Wago Modbus Lib einzusetzen. Ich scheitere im moment an dem Korrekten I-Port. Ich habe es mit 75x_653 und IoConfig_Globals.75x653 versucht, jedoch bekomme ich folgenden fehler: ------ Übersetzungslauf gestartet: Applikation: Device.Application ------- Code typisieren... Code erzeugen... [FEHLER] Unbenannt7: POU_1 Device: SPS-Logik: Application: C0032: Typ 'DED.CAADiagDeviceDefault(caa device diagnosis, 3.5.20.0 (caa technical workgroup))' kann nicht in Typ 'WagoTypesCom.I_WagoSysComBase(wagotypescom, 1.6.2.3 (wago))' konvertiert werden Übersetzung abgeschlossen -- 1 Fehler, 0 Warnungen : Kein Download möglich Wie kann ich den die Karte benutzen?
Last updated: 2024-10-01

Post by cillian on Error when opening HTML5Control Editor CODESYS Forge talk (Post)
Hello, I am new to this forum so apologies if this is posted in the incorrect area. I am getting an error when trying to open the HTML5 Control Editor - this was working fine previous days. I am using Codesys V3.5 SP20 Patch 3. I have reinstalled the application. Below is a screenshot of what shows when I attempt to open HTML5 Control Editor. Would anyone know the solution to rectifying this problem? Thanks in advance. Edit: This is now fixed.
Last updated: 2024-10-22

Post by derpaul on Official MQTT-Client: MAX_RECEIVE_BUFFER_SIZE_EXCEEDED CODESYS Forge talk (Post)
Here is the output Codesyscontrol.log ;**************************************************************** ;<loggername>/tmp/codesyscontrol.log</loggername> ;<logoptions> ; <enable>1</enable> ; <type>normal</type> ; <timestamp>rtc</timestamp> ; <deactivatable>0</deactivatable> ; <dump>always</dump> ; <filter>0x0000000f<filter> ; <maxentries>1000</maxentries> ; <maxfiles>1</maxfiles> ; <maxfilesize>1000000</maxfilesize> ;</logoptions> ;<entries> ;Timestamp, CmpId, ClassId, ErrorId, InfoId, InfoText ;ClassId: LOG_INFO =1 ;ClassId: LOG_WARNING =2 ;ClassId: LOG_ERROR =4 ;ClassId: LOG_EXCEPTION =8 ;ClassId: LOG_DEBUG =16 ;ClassId: LOG_PRINTF =32 ;ClassId: LOG_COM =64 ;</entries> ;**************************************************************** 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <logoptions> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <bEnable>1</bEnable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <type>normal</type> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <timestamp>rtc</timestamp> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <disableable>0</disableable> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <Filter>0x0000000f</Filter> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxEntries>1000</MaxEntries> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFiles>1</MaxFiles> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, <MaxFileSize>1000000</MaxFileSize> 2023-09-12T21:11:41Z, 0x00000013, 1, 0, 0, </logoptions> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, CODESYS Control for PFC200 SL 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 4, OS=Linux, CPU=ARM, Arch=32Bit, Coding=C 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 6, <version>3.5.16.40</version> <builddate>Mar 2 2021</builddate> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 5, Copyright (c) 3S - Smart Software Solutions GmbH 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CM</cmp>, <id>0x00000001</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpMemPool</cmp>, <id>0x0000001e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpLog</cmp>, <id>0x00000013</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>CmpSettings</cmp>, <id>0x0000001a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysFile</cmp>, <id>0x00000104</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCom</cmp>, <id>0x00000100</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysCpuHandling</cmp>, <id>0x00000101</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysDir</cmp>, <id>0x0000011b</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEthernet</cmp>, <id>0x0000011c</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysEvent</cmp>, <id>0x00000102</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysExcept</cmp>, <id>0x00000103</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysInternalLib</cmp>, <id>0x00000107</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMem</cmp>, <id>0x00000108</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysModule</cmp>, <id>0x00000109</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMsgQ</cmp>, <id>0x0000010a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysMutex</cmp>, <id>0x0000013a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysOut</cmp>, <id>0x0000010b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysProcess</cmp>, <id>0x0000010e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSem</cmp>, <id>0x0000010f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemCount</cmp>, <id>0x00000139</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSemProcess</cmp>, <id>0x00000119</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysShm</cmp>, <id>0x00000110</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysSocket</cmp>, <id>0x00000111</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTarget</cmp>, <id>0x00000112</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTask</cmp>, <id>0x00000114</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTime</cmp>, <id>0x00000115</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimeRtc</cmp>, <id>0x00000127</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, System: <cmp>SysTimer</cmp>, <id>0x00000116</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAlarmManager</cmp>, <id>0x0000007c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpApp</cmp>, <id>0x00000002</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppBP</cmp>, <id>0x00000073</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAppForce</cmp>, <id>0x00000074</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpAsyncMgr</cmp>, <id>0x0000005f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtil</cmp>, <id>0x00000004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBinTagUtilIec</cmp>, <id>0x0000005c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBitmapPool</cmp>, <id>0x00000050</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvTcp</cmp>, <id>0x00000030</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpBlkDrvUdp</cmp>, <id>0x00000007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAAsyncMan</cmp>, <id>0x00004007</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAABehaviourModel</cmp>, <id>0x00004015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACallback</cmp>, <id>0x00004001</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAACanL2</cmp>, <id>0x00004004</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAADTUtil</cmp>, <id>0x00004013</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAFile</cmp>, <id>0x00004008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAMemBlockMan</cmp>, <id>0x00004003</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAANetBaseServices</cmp>, <id>0x00004018</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAARealTimeClock</cmp>, <id>0x00004014</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoClient</cmp>, <id>0x00004011</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASdoServer</cmp>, <id>0x00004017</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASegBufferMan</cmp>, <id>0x00004019</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAASerialCom</cmp>, <id>0x00004012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAAStorage</cmp>, <id>0x0000007e</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATick</cmp>, <id>0x00004009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATickUtil</cmp>, <id>0x00004010</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATimer</cmp>, <id>0x00004016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCAATypes</cmp>, <id>0x00004006</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClient</cmp>, <id>0x00000008</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelClientIec</cmp>, <id>0x0000005d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelMgr</cmp>, <id>0x00000009</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChannelServer</cmp>, <id>0x0000000a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCharDevice</cmp>, <id>0x00000300</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpChecksum</cmp>, <id>0x0000000b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCodeMeter</cmp>, <id>0x0000007a</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCommunicationLib</cmp>, <id>0x0000000c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCoreDump</cmp>, <id>0x00000083</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpCryptMD5</cmp>, <id>0x0000006a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDevice</cmp>, <id>0x0000000e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpDynamicText</cmp>, <id>0x00000051</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEL6751CanDrv</cmp>, <id>0x00005f0b</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpEventMgr</cmp>, <id>0x0000005b</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpFileTransfer</cmp>, <id>0x0000005e</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecStringUtils</cmp>, <id>0x0000007f</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecTask</cmp>, <id>0x00000011</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIecVarAccess</cmp>, <id>0x00000060</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoDrvIec</cmp>, <id>0x0000005a</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpIoMgr</cmp>, <id>0x00000012</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKbus</cmp>, <id>0x0000008a</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpKnxStack</cmp>, <id>0x0000004d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpMonitor2</cmp>, <id>0x00000032</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClient</cmp>, <id>0x00000015</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceClientIec</cmp>, <id>0x0000011d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpNameServiceServer</cmp>, <id>0x00000016</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAClient</cmp>, <id>0x00000096</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAProviderIecVarAccess</cmp>, <id>0x00000126</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAServer</cmp>, <id>0x00000124</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOPCUAStack</cmp>, <id>0x0000008d</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpOpenSSL</cmp>, <id>0x00000033</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPfcx00</cmp>, <id>0x00000088</id> <ver>4.0.1.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpPlcShell</cmp>, <id>0x00000128</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancy</cmp>, <id>0x00000129</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRedundancyConnectionIP</cmp>, <id>0x0000ff03</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRetain</cmp>, <id>0x00000017</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpRouter</cmp>, <id>0x00000018</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSchedule</cmp>, <id>0x00000019</id> <ver>3.5.16.30</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecureChannel</cmp>, <id>0x00000090</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSecurityManager</cmp>, <id>0x0000008e</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSessionInformation</cmp>, <id>0x00000097</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSocketCanDrv</cmp>, <id>0x00005f0d</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpSrv</cmp>, <id>0x0000001c</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpTraceMgr</cmp>, <id>0x00000070</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserDBFile</cmp>, <id>0x00000098</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserGroupsDBFile</cmp>, <id>0x00000099</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserMgr</cmp>, <id>0x00000061</id> <ver>3.5.16.40</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpUserObjectsDBFile</cmp>, <id>0x0000009c</id> <ver>3.5.16.20</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuHandler</cmp>, <id>0x00000054</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpVisuServer</cmp>, <id>0x00000057</id> <ver>3.5.16.10</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServer</cmp>, <id>0x00000071</id> <ver>3.5.16.0</ver> 2023-09-12T21:11:41Z, 0x00000001, 1, 0, 10, <cmp>CmpWebServerHandlerV3</cmp>, <id>0x00000072</id> <ver>3.5.16.0</ver> 2023-09-12T21:12:16Z, 0x00000007, 1, 0, 6, Network interface: <ipaddress>192.168.1.17</ipaddress>, subnetmask <subnetmask>255.255.255.0</subnetmask> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>ether 4</interface> at router <instance>0</instance> registered 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 2, Running as network server 2023-09-12T21:12:16Z, 0x00000009, 1, 0, 1, Running as network client 2023-09-12T21:12:16Z, 0x0000000a, 1, 0, 0, <NumOfChannels>4</NumOfChannels> channels available, each of the size <BufferSize>100000</BufferSize> Bytes 2023-09-12T21:12:16Z, 0x00000129, 1, 0, 0, Debug Messages not activated 2023-09-12T21:12:16Z, 0x0000ff03, 1, 0, 0, Read connection settings... 2023-09-12T21:12:16Z, 0x00000030, 1, 0, 6, Local network address: <ipaddress>192.168.1.17</ipaddress> 2023-09-12T21:12:16Z, 0x00000018, 1, 0, 4, Network interface <interface>BlkDrvTcp</interface> at router <instance>2</instance> registered 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, No certificate for the OPC UA server available. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Security policy allows plain text communication. Secure communication is deactivated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, OPC UA Server Started: 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Hostname: PFC200, Port: 4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, URL: opc.tcp://PFC200:4840 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Loopbackadapter activated. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, All available networkadapters are used. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, ************************************************************** 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CODESYS_DefaultProvider with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:16Z, 0x00000124, 1, 0, 0, Provider CmpOPCUAProviderIecVarAccess with Version 0x3051028 registerd at the OPC UA server. 2023-09-12T21:12:17Z, 0x00000126, 1, 0, 0, Valid license found for OPC UA IecVarAccess provider. 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 7, Retains matched to bootproject of application [<app>Application</app>] 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 6, Bootproject of application [<app>Application</app>] loaded 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>0</instance> address to <address>(0011)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 16, 8, Network interface for mainnet=<mainnet>ether 5</mainnet> not found 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>1</instance> address to <address>(0000)</address> 2023-09-12T21:12:17Z, 0x00000018, 1, 0, 1, Setting router <instance>2</instance> address to <address>(2ddc:c0a8:0111)</address> 2023-09-12T21:12:17Z, 0x00000002, 1, 0, 10, Application [<app>Application</app>] started 2023-09-12T21:12:17Z, 0x00000001, 1, 0, 34, CODESYS Control ready 2023-09-12T21:13:37Z, 0x00000001, 1, 0, 0, runtime licensed 2023-09-12T21:17:17Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Channel timeout (<curtime>16012264</curtime>, <lasttime>15982259</lasttime>) 2023-09-13T01:38:17Z, 0x00000009, 1, 418, 0, Closing connection to <address>0329:032e</address> 2023-09-23T14:46:00Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange] 2023-09-23T14:48:57Z, 0x00000002, 1, 0, 2, Application [<app>Application</app>] loaded via [OnlineChange]
Last updated: 2023-09-27

Post by fredsta on Unable to load dynamic modules (Download failed: Application=Application) CODESYS Forge talk (Post)
Hey there, I am currently trying to find a good solution for the communication between CODESYS Control on Raspberry Pi and "the rest of the world", i. e. the things apart from CODESYS on my linux. My first approach was to use the c-integration. So I created a lib, defined extern fbs, compiled the code on my Pi using the SDK and put the .so into my lib project. When I try to log into the Pi and load the program, I get the error message which you can see in the attached picture. "Die dynamischen Module der C-Integration konnten nicht auf das Laufzeitsystem geladen werden" is german and means roughly "the modules from the c-integration could not be loaded onto the runtime system." Is this normal? Am I doing something wrong? I will have a look at the unix domain socket thing next, as I am still in the process of finding the best solution for the communication.
Last updated: 2024-02-15

Post by dominggus on when going online, stuck on "Syncing file "visuelemsdatetime.tl_datetime.txt" CODESYS Forge talk (Post)
Hi, We are currently using a Raspberry Pi 4 CM4 module in a EdgeBox RPI 200 - Industrial Edge Controller running the latest CODESYS Runtime Package 4.11.0.0. On the PC (actually an Intel Macbook Pro running Windows 10 in Parallels) we run CODESYS V3.5.19.50. Yesterday end of day when I was about to logoff and head home, I wanted to send the latest build to the Raspberry I clicked the Login button to compile a new version and then sync the application and all the files, it get's stuck on the last file to sync (see attached screenshot). This takes eternally, although sometimes, when I use my SFTP client (Cyberduck) and go into the raspberry and refresh the directory /var/opt/codesys/PlcLogic/visu/, or when I open the actual file visuelemsdatetime.tl_datetime.txt, it gets un-stuck (forcing a refresh, which might fix the syncing issue) and CODESYS continues and I can click the Start button to start the application. But this SFTP force refresh trick does not always help either... What could be the issue here? network connectivity? Can someone please help me out?
Last updated: 2024-03-02

Post by umdee on Error when monitoring LAD programs CODESYS Forge talk (Post)
System Information from the computer being used: OS Name Microsoft Windows 11 Pro Version 10.0.22631 Build 22631 Other OS Description Not Available OS Manufacturer Microsoft Corporation System Manufacturer Dell Inc. System Model Latitude 5500 System Type x64-based PC System SKU 08B9 Processor Intel(R) Core(TM) i7-8665U CPU @ 1.90GHz, 2112 Mhz, 4 Core(s), 8 Logical Processor(s) BIOS Version/Date Dell Inc. 1.3.11, 6/11/2019 SMBIOS Version 3.2 Embedded Controller Version 255.255 BIOS Mode UEFI BaseBoard Manufacturer Dell Inc. BaseBoard Product 0M14W7 BaseBoard Version A00 Platform Role Mobile Secure Boot State On PCR7 Configuration Elevation Required to View Windows Directory C:\WINDOWS System Directory C:\WINDOWS\system32 Boot Device \Device\HarddiskVolume1 Locale United States Hardware Abstraction Layer Version = "10.0.22621.2506" User Name CARDASSIA-IX\Engineer Time Zone Eastern Daylight Time Installed Physical Memory (RAM) 16.0 GB Total Physical Memory 15.8 GB Available Physical Memory 4.67 GB Total Virtual Memory 18.5 GB Available Virtual Memory 2.52 GB Page File Space 2.63 GB Page File C:\pagefile.sys Kernel DMA Protection Off Virtualization-based security Not enabled Windows Defender Application Control policy Enforced Windows Defender Application Control user mode policy Off Device Encryption Support Elevation Required to View Hyper-V - VM Monitor Mode Extensions Yes Hyper-V - Second Level Address Translation Extensions Yes Hyper-V - Virtualization Enabled in Firmware Yes Hyper-V - Data Execution Protection Yes
Last updated: 2024-03-19

Post by fajean on CODESYS control on RPi starts, shortly runs, then exits CODESYS Forge talk (Post)
I have a Raspberry Pi 4 we have been using for years to run CODESYS for development purposes. I recently have had to re-install the OS (Raspberry OS lite). The only change to the default configuration is not creating the "pi" user during install. I (apparently successfully) installed the 4.10.0.0 control on the Raspberry Pi. We have licences on a dongle. I am able to start the control. systemctl status shows it as running for a little while (exactly, precisely 30 seconds as per my tests, every time), then it becomes exited. I can restart the control, and the same thing happens again. Every time. In the brief moments it is running, I can log in to the PLC. Working fast and restarting the control many times, I have been able to configure users. I have been able to download my application. I have been able to run the application, and stop on a breakpoint. I have been able to connect with the licence manager and confirm the dongle is detected and licences are listed as OK. I see nothing wrong until the service just exits. I have found nothing in the logs. It is like the runtime just terminates with no error code or message after exactly 30 seconds. Any help would be appreciated.
Last updated: 2024-06-13

Post by rossanoparis on How to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server CODESYS Forge talk (Post)
Hello at all I'd like to know how to configure CODESYSControl_User.cfg in order to use a specific network card for OPCUA Server. In the past, I tried to ask in "Forge" about this topic, but I could find neither help nor document informations about it. Reading the file "codesyscontrol.log" I see these logs OPC UA Server Started: Hostname: NTLRPICTRL01, Port: 4840 URL: opc.tcp://NTLRPICTRL01:4840 Loopbackadapter activated. **All available networkadapters are used.** Multithreading activated. 3 workers used. My controller, which is a Linux PC, has got two network cards eth0 and eth1 I whant to use the card with name "eth0" as a server for OPCUA and keep the "eth1" free for other stuffs. Is it possible ? Best regards Rossano
Last updated: 2023-08-25

Post by janber0206 on Lizenz lässt sich nicht aktivieren für Revolution Pi CODESYS Forge talk (Post)
Ich versuche grade die Lizenz für den Revolution Pi zu aktivieren, das hat auch schon im Laufe eines Jahres 20 mal geklappt, jetzt bekomme ich grade nur die Fehlermeldungen zu sehen in den angehängten Screenshots. Die Aktivierung der OPC-Client Lizenz lief ohne Probleme geht nur um die aktivierung für die Codesys Control for Raspberry Pi MC SL. Ich habe sowohl die Webaktivierung versucht als auch in der Codesys IDE, im Lizenz Manager versucht die Lizenz zu aktivieren. Aktivierung mit Dongle kommt nicht infrage da die bei Endkunden eingebaut werden. Hatte jemand ähnliche Probleme, bzw. weiß jemand wie das zu beheben ist? MfG Jannis
Last updated: 2023-10-27

Post by sachem on Problem retain values Weidmuller UC20-WL2000 CODESYS Forge talk (Post)
Good afternoon. I am working with a weidmuller uc20-wl2000 controller, using a codesys license. We made a ladder code to control a process, and it works well, but we want some variables to remain stored even when the controller is turned off. We tried to use retain variables, but at the time of loading the program, when we went offline from the controller, the program was deleted, it did not remain in the controller, and in the same way if we turned off the controller. In addition to this, when we tried to program it again, the program would not stay loaded and began to present errors with the opc-ua communication. What could be causing this problem? How can we maintain the values of the variables without damaging the program or affecting the controller? thank you
Last updated: 2024-04-10

Post by viksym on Get text from textlist CODESYS Forge talk (Post)
Does anybody know how to get a specific text from a text list within a program. Obviously it works in a visualization, but because I will have an HMI that has it's own system and I will have to send variables to this HMI via an OPC UA connection, I need to be able to get a text into a string. I tried using the VisuElems like this, but it only returns an empty "" and nothing else. IF trig THEN sText := VisuElems.cmpDynamictext.DynamicTextGetDefaultText(ADR(sTextList), ADR(sAlarmID))^; //sText := VisuElems.cmpDynamictext.DynamicTextGetText(ADR(sTextList), ADR(sAlarmID))^; trig := FALSE; END_IF Any help and idea is highly appreciated because I am getting desperate here.
Last updated: 2024-05-31

Post by khaledkhalil on Question about the hairaichy of UaExpert CODESYS Forge talk (Post)
Hello, I am Examining this Example from Codesys Tutorial about OPC-UA server here https://www.youtube.com/watch?v=aJhzN3Uk-Do&list=PLWtD08CpmZcSV26aWh1axCAef5c5HxX-3&index=1&t=1167s. Now i am running to problem, when i create instances and i want them to appear directly under the object directory, However, it always appear with me under Objects >> Device set >> Device Name in CODESYS. I need to know how i can change the directory of my instances 'inst_3' and so on. So they can be under objects directly. I tried to modify the settings, but couldn't find any leads till now. Thanks in advance for helping
Last updated: 2024-09-12

Post by eschwellinger on Zielsystem stimmt nicht mit dem verbundenen Gerät überein CODESYS Forge talk (Post)
na ja es gibt halt einfach die Möglichkeiten: 1. Man installiert Raspberry PI OS 32Bit -> dann geht PI SL und PI MC Multicore als Target 2. Man installiert Raspberry PI OS 64Bit dann muss es PI64Bit sein falls der Übersetzungsfehler nicht in einer Bibliothek ist (die du vielleicht nicht ändern kannst) https://faq.codesys.com/pages/viewpage.action?pageId=128253958 Hier der Hinweis was man tun muss das dein IEC Code für 32Bit als auch 64Bit Targets funktioniert Also entweder zurück auf Raspberry PI OS 32 Bit: nur zur Info noch was im Config file steht für welche Plattform/Produkt [CmpRasPi] Architecture=aarch64 (-> 64Bit PI) oder Architecture=armv7l (-> PI MC Multicore) oder Architecture=armv6l (-> PI SL Single Core)
Last updated: 2024-03-11

Post by naks on Change IP address from IEC code CODESYS Forge talk (Post)
Hi, I'm working with wago 750-8212 controller. I want to change the IP address of the Ethernet adapter from webvisu. I have read some other threads in this forum and I have tried the following: Added the following text to the config file CODESYSControl.cfg: [SysSocket] Adapter.0.Name="br1" Adapter.0.EnableSetIpAndMask=1 Used the below code : IF xUpdateEthernet THEN Ethernet.Enable := FALSE; Reconfig ( xExecute := TRUE, itfNode := Ethernet, eError => ErrorReconfig, xBusy => xBusy, xDone => xDone, xError => xErrorReconfigure); IF Reconfig.xDone THEN ErrorCode := Ethernet.UpdateConfiguredIPSettings(IpAddress := NewIp, gateway := newGateway, subnetmask := newSubnetmask); END_IF IF Reconfig.xDone OR Reconfig.xError THEN reconfig(xExecute := FALSE); END_IF Ethernet.Enable := TRUE; Reconfig(xExecute := TRUE, itfNode := Ethernet ); END_IF I could change the IP address but when i restart my Controller then the IP address resets to the original, Is there anything I have missed, what else can i try ? Thank you in advance.
Last updated: 2024-07-08