Post by pernockham on Control for linux SL, 4.14.0.0 -> 4.15.0.0 breaks web page access. URL requires authentication
CODESYS Forge
talk
(Post)
I have a problem which I have identified with a device-update from 4.14.0.0 to (4.15.0.0-4.17.0.0) where the newer versions will stop any local access to the internal web page with the browser responding "The requested URL requires authentication". Setting the device back to 4.14.0.0. the web page will respond. Access to web page through Automation server is possible also for the newer version, but not "local" access. Runtime (Codesys control for linux SL) is on 4.17.0.0. I have tried to manipulate settings for 'Access-Control-Allow-Origin' '*' always; through nginx (normally a proxy_pass to localhost:8080). Also tested bypassing nginx by accessing 8080 directly with the same result.
Last updated: 2025-09-08
Post by pernockham on *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv
CODESYS Forge
talk
(Post)
*** The system may be in an inconsistent state, please reboot *** *Exception* Async service: ServiceGroup=17, IP=0x5fa45617, Component=CmpSrv Every time at the instant that I Login to the system a message that the "system may be in an inconsistent state, please reboot" is written in the log. If I logout and repeat login a new entry is set. My system is a "Control for linux SL" running on a debian linux host. Im running it on my desk without any IO attached so message might be caused from that, but I doubt i have seen it before. Rebooting makes no difference. Anyone that have a clue of how I should interpret this error message?
Last updated: 2025-09-26
Post by arjunk on How to correctly create a device descriptor (.devdesc.xml) for a custom Linux ARM64 PLC in CODESYS 3.5.21.20?
CODESYS Forge
talk
(Post)
I’m trying to integrate a custom PLC into CODESYS so that it appears under the Device section. From what I understand, this requires a .devdesc.xml device descriptor file. I attempted to create the XML manually, but whenever I try to install it in order to generate a .package file, CODESYS crashes. CODESYS version: 3.5.21.20 Target PLC: Linux ARM64–based My questions are: Is there an official or easier way to generate a valid .devdesc.xml file for a custom PLC? Are there tools, templates, or examples that can help ensure the XML is structured correctly and won’t cause crashes? For Linux ARM64 targets specifically, is there a recommended starting point (e.g., modifying an existing device descriptor)? Any guidance or best practices for creating and packaging custom device descriptors would be greatly appreciated.
Last updated: 2025-10-06
Post by budd7566 on Text size suddenly changed
CODESYS Forge
talk
(Post)
Iv been working with a Deep Sea Electronics DSE840 for about 6 months. I have a development version of my program working with a state machine and a basic gui interface. I went to implement CAN and suddenly the text on the gui on the controller is much larger than before. I could flash old versions of my project and the text was the correct size, but if i renamed the project file, the text displayed would be large. The visualization in CODESYS always shows the expected size, but not the controller. I did a fresh install of CODESYS and even a new project with only one text box, I cant get the text size on the controller to match what is displayed in codesys to match. Any advice?
Last updated: 2023-12-09
Post by royw on Profinet library for C#
CODESYS Forge
talk
(Post)
Hi, I don't know if I'm in the right place or if it's even possible... I'm looking for a way to address a Profinet device with Record Read and Write from my own PC. I actually only need very few commands to configure our device. This means setting the MAC address and a serial number. We would like to do this from a C# program. Now we are looking for a library or something similar. Since you can do it from Codesys, I thought there might be a DLL or something similar that you could use for this. As I said, we don't want real-time queries of the cyclic data but only record read/write. Does anyone have any helpful hint? Thanks in advance
Last updated: 2023-12-22
Post by andrax on Save Recipe on Paspberry
CODESYS Forge
talk
(Post)
Unfortunately not. The folder does not work. There are neither error messages nor any other indication that this may be due to missing rights. I have searched the entire forum and also tested the Codesys example. The simple recipe management generally does not work! The Raspi crashes with the extended recipe management from the example. I have now found another sample that works. https://forge.codesys.com/forge/talk/Engineering/thread/61c6a04b79/ Many thanks to mcodem. After some trial and error I have found out: xcreate must be called at least once at runtime. After that xload_write and xread_save work All other functions do not work. It is also possible to save to the /home/Documents folder. So it is not due to the rights. It would be nice if Codesys would check where the problem really lies.
Last updated: 2023-12-30
Post by jdjennings1962 on Trouble accessing Math functions in OSCAT library
CODESYS Forge
talk
(Post)
Hi all, I am trying to utilize the ARRAY_SDV standard deviation function, part of the Math group in the OSCAT library downloaded from the CODESYS store. My Codesys version is 3.5.19.10. When I add the OSCAT to my Library, it shows a subset of the library (Standard) as fully installed and signed (see pic). However, the Math functions are not in this Standard group. The Math functions I need can be viewed as source code in the full OSCAT_BASIC, though this the symbol next to this library suggests it is source only and not fully installed. When I try to declare an instance of the ARRAY_SDV function in a program, it is not known. I have tried reinstalling and Building . . . Any help would be greatly appreciated. Jeff
Last updated: 2024-01-06
Post by askjong on Update variables when OPC UA Client updates. Error ID: 268468277 BadAttributeIdInvalid
CODESYS Forge
talk
(Post)
Hi, I'm connecting to a OPC UA Server using the Data Soruce Manager OPC UA Client. This works well until the OPC UA Server updates and the OPC UA list doesn't match up when i did last clicked the "Update variables" to add variables. All the variables are still the exists and none are removed from the server, but more are added during the engineering process. The error message i get in CODESYS is "Error in OPC UA call BadAttributeIdInvalid, Error ID: 268468277". The issues is fixed when i press the "Update variables" button and just press ok without adding or removing any variables in the list. Is there a way to either automatically update the browsepath if it fails or on startup, or to trigger it by code?
Last updated: 2024-01-08
Post by jeroen on Ramp function
CODESYS Forge
talk
(Post)
Hi, Found a nice ramp function in the OSCAT lib (FT_RMP), but is there a nice way to 'set' the output to the current input as form of a reset. The reason for this, is that I want to set up a ramp for a pressure control input that should have x Bar/sec linear rise input. The only option (or code it by hand) I found is this OSCAT FB. Any other options? Just need to increase a value by x Bar/sec from let's say 250Bar (as start) to end 1500Bar. The Oscat ramp will always start at 0 when enable is off (FT_RMP.Rmp := FALSE)
Last updated: 2024-01-09
Post by gallusrrr on usb2can in Codeysy 3.5 Can Gateway
CODESYS Forge
talk
(Post)
Hallo Forum das ist mein erster Post bei euch also bitte seit nachsichtig :) ich habe mir den: USB zu CAN Konverter Kable for Raspberry Pi4/Pi3B+/Pi3/Pi Zero(W)/Jetson Nano/Tinker Board and Any Single Board Computer Support Windows Linux and Mac OS (USB2CAN-C) Gekauft da er in Linux arbeiten soll dachte ich man kann den so in codesys einbinden da es auf einen Rasperry Pi lauft. Erkannt wird der Adapter als Bus 001 Device 004: ID 1d50:606f OpenMoko, Inc. Geschwister Schneider CAN adapter Wie bekomme ich den in Codesys mit einen Rasperry pi eingebunden. (Im Internet habe ich nichts gefunden.) ich bedanke mich. euer Martin
Last updated: 2024-01-16
Post by riccardo on Error while processing the visualization: Client id not present or no longer valid
CODESYS Forge
talk
(Post)
Hallo goodmorning, I am using codesys 3.5 sp19 with Weidmueller PLC. I created a page with several checkbox to manage an array of bool. When I build the project the system doesn't signal any error, when I go in simulation mode everything works until I click on checkbox to toggle the variables. Other visu elements works proprerly (e.g. bottons, lights, ect, ect) but the check boxes cause a crash giving the following error: Error while processing the visualization: Client id not present or no longer valid I serched to figure the problem out and to search a solution on the web but nothing. Can someone help? Thanks and Regards, Scanu
Last updated: 2024-01-23
Post by matt-s on HMI Pushbutton/Move Instruction
CODESYS Forge
talk
(Post)
I am having an issue where the manual start/stop push buttons on the HMI are supposed to take the pumps/blowers out of auto. The logic I have attached works for the pumps, but not the blower. From what I can tell it is the exact same logic, but it is not writing a 0 to the Auto PB variable. Attached is the logic, cross reference list to show nothing else is writing to it, and the HMI screen. Any help? Am I missing something? I am using a Groov Epic PR1, my software version is 3.5 SP19 Patch 5 32 Bit.
Last updated: 2024-01-25
Post by mondinmr on Shared Memory Access Issues
CODESYS Forge
talk
(Post)
In Windows I need create shared memory in PC software and connect from CODESYS. If shm is not GLOBAL doesn't work due different users between runtime and PC software. PC software need admin privileges. Name need "Global\\" before key. Very unsafe!!! If CODESYS create shared I cannot find key PC side. In Linux I can create shared memory as standard user, bind in the runtime docker, use keys without any "Global\\". Much more safe!!! If CODESYS create shared you need play with permissions to use app as standard user. I prefer create form PC software as standard user.
Last updated: 2024-01-30
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by nmcc on How to address visualization change with button press...
CODESYS Forge
talk
(Post)
Hello all, I am extremely new to Codesys and to programming with these languages in general. I have an HMI panel with 8 physical buttons to the right side of it. I am trying to have these set to change the visualization to a specific screen which I have designed 8 of. I currently have "use CurrentVisu" enabled in the visualization manager. I also have input blocks with all of the buttons being directed to output blocks which I want to have as the switcher for the visualization. Picture is attached for what I have currently. This could be the wrong approach to this issue. Any help is much appreciated.
Last updated: 2024-02-13
Post by mp9876 on Attempting customizing menus fails in LADDER environment; due to free CODESYS version ?
CODESYS Forge
talk
(Post)
Hello, I am attempting to get started here and bumping into this funny issue. I am using this version of CODESYS: ============================== DETAILED VERSION INFORMATION Created at 2024-03-10 ============================== Startup profile: ............................................................... CODESYS V3.5 SP19 Patch 6 OS version: .................................................................... Microsoft Windows NT 10.0.19045.0 .NET version: .................................................................. 4.0.30319.42000 When attempting to customize the menus or toolbar it does not work. The additional commands, Insert TON box & Insert TOFF box, are present in the Customize Menus or Toolbars when re-opening the Customize options but neither the menu or the toolbar gets updated with these. Would also like to add them in the Ladder Toolbox as there are only 9 items in there which does not include the one mentioned above. Due because of the version I am using ? Any assistance would definitely be appreciated. Thank you Mike
Last updated: 2024-03-10
Post by esave on Stepper Drive with Ethercat
CODESYS Forge
talk
(Post)
Hello everybody I am new into Codesys. I have a stepper driver (EM3E-556E) from Leadshine. I want to controll the stepper driver via EtherCat to a ST programm but I dont have any function block or anything that i can use. I only have the XML-File wich I loaded. With it I implemented the drive as a Ethercat slave and now I see these variables. (See picture) I dont know how to controll the stepper drive. And the manufacturer doesnt provide support for me. Can anybody help me or atleast tell me how they would do it?
Last updated: 2024-03-14
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
If support for a containerized CODESYS runtime with a license isn't feasible, then I've considered an alternative approach: I've purchased and activated a "CODESYS Control Basic S" license on my Windows notebook, where I already have the Codemeter Control Center installed. Upon activation, I can see the CODESYS license as active on my notebook. Subsequently, I followed the instructions provided in this link (https://faq.codesys.com/display/CDSFAQ/How+to%3A+Setup+a+Wibu+Network+Server+Access+for+Licenses) to configure the Wibu runtime in the CODESYS container to access my external license server hosted on my notebook by editing the CODESYSControl_User.cfg file accordingly. However, it's worth noting that I'm still receiving a response from the Licensing Manager indicating that the runtime is persistently searching for a dongle instead of recognizing the soft container. So how can I get my runtime licensed now? Any ideas?
Last updated: 2024-03-20
Post by superjojo2002 on Licensing info not available.
CODESYS Forge
talk
(Post)
I recognized that I have to start the two services "/etc/init.d/codemeter" and "/etc/init.d/codemeter-webadmin" in the docker container as well. If I do so, then the command "cmu -x" returns root@sensoredge-field-netfield-produktmanagment:/# cmu -x cmu - CodeMeter Universal Support Tool. Version 7.60c of 2023-Aug-09 (Build 5625) for Linux/ARMHF 64-Bit Copyright (C) 2007-2023 by WIBU-SYSTEMS AG. All rights reserved. So this time there is no indication any more that "Codemeter is not running". But still we are getting the error when using the license manager in CODESYS development system.
Last updated: 2024-03-21
Post by phoward131 on Text List Fallback Value
CODESYS Forge
talk
(Post)
I am relatively new to Codesys and I'm trying to develop an HMI that displays what mode a particular device is in based on an integer value. I am currently using dynamic texts with a text list which works fine but I am looking for a way to display a particular string (ie 'Unknown') when the index doesn't match any of of the indices in the text list. I can enter 'Unknown' in the text property of the text field element which works as expected but it displays the single quotes on the visualization. How can I escape these quotes to simply display the word Unknown? Thanks!
Last updated: 2024-03-22
Post by mwandy on Codesys Project Protection
CODESYS Forge
talk
(Post)
I'm having trouble finding clear answers on this. I'm looking for a way to make a Codesys project password protected so that if the project is distributed it can be used to log into a controller to view and debug logic. At this same time I want to prevent the project from being saved as well as edits being downloaded to the controller. Basically I want to make a whole project view-only. What is the beat way to achieve this? I have had minor success with access rights, which solves the problem with trying to login if the project doesn't match what is in the controller. However with this solution, edits can still be made and saved, possibly corrupting the core project, preventing future logins. Any suggestions?
Last updated: 2024-03-29
Post by hafizapik99 on Webvisu not showing Codesys V3.5 SP13 Patch 4
CODESYS Forge
talk
(Post)
Hello, I am using a Hitachi Micro EHV+ for a small project, and I wanted to have a Web visu, done with Codesys V3.5 SP13 Patch 2. I test the Visu screen and it works well in Codesys, but I get a blank page when i enter the web visu in a browser. Here is the setting under web visualization: Update rate (ms): 5000 (previously set to 2500 also not working) Default communication size: 100000 (previously set to 50000 also not working) Under Visu_Task tab: Priority: 3 The Visu_Task interval is set to 2500ms (previously set to 200ms also not working) I'm using Google chrome with the latest update, the Javascript is enabled with HTML5. Any advice?
Last updated: 2024-04-06
Post by hafizapik99 on Webvisu not showing Codesys V3.5 SP13 Patch 2.
CODESYS Forge
talk
(Post)
Hello, I am using a Hitachi Micro EHV+ for a small project, and I wanted to have a Web visu, done with Codesys V3.5 SP13 Patch 2. I test the Visu screen and it works well in Codesys, but I get a blank page when i enter the web visu in a browser. Here is the setting under web visualization: Update rate (ms): 5000 Default communication size: 100000 Under Visu_Task tab: Priority: 3 The Visu_Task interval is set to 2500ms I'm using Google chrome with the latest update, the Javascript is enabled with HTML5. Any advice?
Last updated: 2024-04-06
Post by mbmik on IoDrvModbusTCP_Diag not defined when using MODBUS
CODESYS Forge
talk
(Post)
Hi Im trying to setup a Weidmüller WL2000 to run with MODBUS, to get some data from a server. Codesys V3.5 SP20. The issue is, that whenever i attach an ethernet port and add MODBUS Master und also a Slave, codesys will compile the project, but there always seem to be some remaining errors, which or only visible, when setting the messages window to "Pre-Compiled". I tried a lot of stuff to get rid of these errors, but cant find to seem the reason. New installation of codesys, cleaned project, setup completely empty new project, manually adding libs. Nothing helps. Any help is apreciated. Maybe we are doing something wrong.. Example Project is available, if somebodey wants to take a look. Greetings and thanks alot
Last updated: 2024-04-15
Post by ac-spr on Runtime variable that indicates a user is online to the code
CODESYS Forge
talk
(Post)
Looking to access a variable at runtime that indicates a user is online to the code. essentially want to use this value to feedback to the user on the HMI. we use turck and bosch rexroth devices if this information helps. I was hoping there was a variable at the application level, or a library that could be used but I was unable to find anything. I know there's a pop up when you try to login/ go online to the code when a user is already logged in, so the system does provide an indication that it knows already online, but has no access to a value from what I can see. Any help is appreciated
Last updated: 2024-04-22