Search talk: init function block

 
<< < 1 .. 33 34 35 36 > >> (Page 35 of 36)

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by salvadegianluca on How to use TON inside an FB that is instanced within a Visu page CODESYS Forge talk (Post)
Hi everyone; I'm building a project in which the drag of the mouse over some controls (or the click event) changes the background color of the control items; this change of color is made with an FB that assignes a color code to the background with MUX command based on the value of an enumerator, this part is perfectly working but, when I'm using a touchpanel instead of a web visu (controlled by a mouse) I get into some issues as it seems that the touch operations are not triggering the MouseEnter and MouseLeave properties as it's done with the mouse.... For this reason I'm trying to add a TON to my FB and, if the enum that changes color remains at the same state for more then 3s I'm automatically resetting it to it's "0" so the item gets back the not selected color. Anyhow it looks like the TON function from library is not working in these FB that are instanced in the various visualizations, as instead they do if I create some instances within the POUS. Anyone has ideas of how to make them work?
Last updated: 2024-04-15

Post by rabaggett on CODESYS control for Raspberry Pi 64 SL errors CODESYS Forge talk (Post)
Hi, I am trying to create a project using a raspberry pi, I have added the modules for the Pi and MCP3008. I have encountered som errors that I don't know how to track down. 1. The GPIOs give preprocessor errors, but I read that this does not prevent compiling. This seems to be true. I can build the empty project with no errors. 2. After adding a SPI master and MCP3008, the preprocessor errors double, but seem similar and the project again builds with no errors. 3. I add a DUT and GVL, with a function, and I get the following errors. They remain even if I delete these things. ------ Build started: Application: Device.Application ------- Typify code... [ERROR] crr: C0032: Cannot convert type 'Unknown type: 'ADR(GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7)'' to type 'POINTER TO IoConfigParameter' [ERROR] crr: C0077: Unknown type: 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7.Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' [ERROR] crr: C0046: Identifier 'GVL_Io_17160064_c083_41f8_9e53_208be7537753_HPS_7' not defined Compile complete -- 3 errors, 0 warnings I attach the project. What am I doing wrong? Thanks!
Last updated: 2024-05-02

Post by hanoues on setting date and time on CPX-E CODESYS Forge talk (Post)
Hello, Can anybody here tell me how to modify the time and date on my CPX-E? I used the code I found on CODESYS online help, but it doesn't work. What am I missing? FUNCTION current_date_time : STRING VAR stUTC_Timestamp : SysTime; //utc time // ULINT#1528280694913 stLocal_TimeStamp : SysTime; //local time but is in general equal // ULINT#1528280694913 stdNow : SysTimeDate; //local time in an object to access each number (day, month...) dtNow : DATE_AND_TIME;//DT#2018-6-6-10:24:54 todNow : TIME_OF_DAY; // TOD#10:24:54.913 datNow : DATE; // D#2018-6-6 END_VAR SysTimeRtcHighResGet(stUTC_Timestamp); // ULINT#1528273494913 SysTimeRtcConvertHighResToLocal(stUTC_Timestamp, stdNow); //convert UTC ULINT to Local SysTime // stdNow.wYear = UINT#2018 // stdNow.wMonth = UINT#6 // stdNowy.wDay = UINT#6 // stdNow.wHour = UINT#10 // stdNow.wMinute = UINT#24 // stdNow.wSecond = UINT#54 // stdNow.wMilliseconds = UINT#913 // stdNow.wDayOfWeek = UINT#3 // stdNow.wYday = UINT#157 SysTimeRtcConvertDateToHighRes(stdNow, stLocal_TimeStamp); // ULINT#1528280694913 dtNow := TO_DT(stLocal_TimeStamp / 1000 ( ms )); // DT#2018-6-6-10:24:54 todNow := TO_TOD(stLocal_TimeStamp MOD TO_ULINT(T#1D)); // TOD#10:24:54.913 datNow := TO_DATE(dtNow); // D#2018-6-6 (convert to appropriate string) current_date_time := concat('$N[', TO_STRING(dtNow)); current_date_time:= concat(current_date_time,'.'); current_date_time:= concat(current_date_time, TO_STRING(stdNow.wMilliseconds)); current_date_time:= concat(current_date_time,'] - '); RETURN;
Last updated: 2024-05-21

Post by tortilla on J1939 connection between two devices CODESYS Forge talk (Post)
Hey, I'm pretty new to CoDeSys so I don't know a lot of things yet. I have to create a connection between two devices (CANbus - J1939 connection). The idea for now is to send a message from one to another (one operates on 3.5 SP11 the other one on 2.3) I watched a few videos, worked with the documentation and worked with chatGPT 4o and was able to build the attached file. This part is about the device on 3.5.11: I'm using the J1939LocalECUDiag, TransmitParameterGroup, TransmissionTrigger Function blocks to send the message but my TransmitPG.xBusy / .xDone never turns to True and therefore my message is not sent while TransmitPG.xExcecute is True. I added the two devices in the CANbus in the J1939Manager and addapted the options like I've seen in the documentation. Can anyone explain what's wrong with my code in this casse or give me advices how to properly create a connection between my two devices? Thanks in advance!
Last updated: 2024-05-23

Post by bmatlove on Re-create CoE online window in Visu CODESYS Forge talk (Post)
Hello, I am trying to re-create the CoE online window within a Visu for purposes of checking and interacting with device parameters occasionally for maintenance purposes. To minimize reliance on using the IDE for misc interactions. Ideally, I would like to exactly mimic the CoE online window within the IDE. I assume that it uses a few tricks to minimize overhead, such as only polling registers which are within the visual scope, for example. I'm afraid it might be too much to ask for a pre-built drop-in Visu module to exist for this task. Do I have any options aside from manually re-creating all the logic to do this, relying heavily on SdoInfo function blocks? Is there a way for me to reference the device ESI file to shortcut the process of determining how many registers there are and getting the address for each?
Last updated: 2025-12-27

Post by fredashbolt on Dynamically Update JSON Payload CODESYS Forge talk (Post)
I am trying to generate a JSON payload populated with a value that updates for use with a telemetry system, the payload is to be published by MQTT. I have established the MQTT client and can publish a working JSON payload but I can't get the payload to update as the value (iValue) changes. I am using a timer to trigger the .SetValue function periodically, but the JSON will only give the value as it is when it is first initialized using xFirst IF statement. Any suggestions? Thanks VAR pJsonData : POINTER TO JSON.JSONData := factory.Create(); fb_JBuilder : JSON.JSONBuilder; diRootIndex, diObject1Index : DINT; iValue : INT := 10 ; jsonArrayWriter : JSON.JSONByteArrayWriter; wsJsonData : WSTRING(1000); xFirst : BOOL := TRUE; utf8JsonData : STRING(2000); diTempVal : DINT ; PublishTimer : TON ; END_VAR IF xFirst = TRUE THEN fb_JBuilder ( pJsonData := pJsonData , diRootObj => diRootIndex ) ; diObject1Index := fb_Jbuilder.SetKeyWithObject ( "Device" , diParentIndex := diRootIndex ) ; diTempVal := fb_Jbuilder.SetKeyWithValue ( "Temp" , iValue , diParentIndex := diObject1Index ) ; xFirst := FALSE ; END_IF PublishTimer ( IN := PublishTimer.Q = 0 , PT := T#5S ) ; IF PublishTimer.Q THEN fb_JBuilder.SetValue ( iValue , diTempVal ) ; END_IF jsonArrayWriter( xExecute := PublishTimer.Q , pwData := ADR(wsJsonData), udiSize := SIZEOF(wsJsonData), jsonData := pJsonData^, xAsyncMode := FALSE ) ; JSON.Stu.ConvertUTF16toUTF8( ADR ( wsJsonData ) , ADR ( utf8JsonData ) , SIZEOF ( utf8JsonData ) , bStrictConversion := TRUE ) ;
Last updated: 2026-03-10

Post by nickpoon on SysProcessCreate stopped working after SP21? CODESYS Forge talk (Post)
I'm going through the process of updating the CODESYS Project a machine to 3.5 SP21 (old version was 3.5 SP20). One function that stopped working when upgrading was SysProcessCreate. I need to run a .exe file that is located in C:\Program Files\MQTTStream. Some initial searching suggested that there are new security rules that prevent the SoftPLC from reading/writing files to outside of its Device folder (located here - C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770) Relocating files helped fix my JSON file reader/writer functions (which were failing previously), but not the case for SysProcessCreate. I've even attempted to just run window's cmd.exe and with: pszCommandLine = 'cd /d C:\Windows\System32\config\systemprofile\AppData\Roaming\CODESYS\CODESYSControlWinV3x64\24FD6770\PlcLogic\MQTTStream & sift-proxy.exe --grpc_uri="https://grpc-api.siftstack.com" --api_key="xxxxxxxxxxxxxxxxxxx" mqtt-client --broker_ip=10.0.10.101 --broker_port=1883 --config_file="mqtt_telemetry_config.json" --username Plantd --password 1234 --stream_metrics --storage_path="sift-proxy-logs"' I have not been able to find a lot of documentation on this, and I suspect the new update may have created a bug for SysProcessCreate. Any help would be greatly appreciated
Last updated: 2026-02-02

Post by konstantin on CAM Motion Recover after STO CODESYS Forge talk (Post)
Hello Mr. Seidel, both the master and the slave axis are modulo. Basically the situation is as follows: One master cycle is 100 units. Slave's modulo length is 2000 units. In the CAM table I defined 10 master cycles on X axis - 1000 units and on the Y axis is the slave - 2000 units. Then depending on the master position 0 to 1000 units the slave's position is plotted on the Y axis - 0 to 2000 units. For example, while the master is executing the 3rd cycle i.e. above 200 units, I trigger the STO function of the slave and it stops. The master executed his cycle but the slave was stopped during the execution. How can I set the slave to continue the CAM sequence from the point where it stopped i.e. third cycle of the master? When I reset the slave error and sync again, everyrhing starts from master's 0 position. Best Regards Konstantin Kolev
Last updated: 2026-02-13

Post by charleskirkland on Connect to Azure IoT Hub CODESYS Forge talk (Post)
It sounds like your TLS setup is basically correct, since the handshake works via OpenSSL, so the issue is likely on the CODESYS side rather than the certificates themselves. From what I’ve seen with the Azure IoT Hub Client SL library, you should double-check that the SAS token is actually being generated and passed correctly to the function blocks (especially wsDeviceSaS) and that the MQTT/HTTPS FB is really triggered cyclically-otherwise the controller won’t initiate the connection at all. Also, make sure DNS, time (NTP), and full certificate chain trust are properly configured on the controller, since IoT Hub authentication depends on them even when using SAS tokens. Another thing worth checking is the library/runtime version-there are reports that certain versions changed behavior and caused connection issues. I’d recommend starting with the official demo project (AzureMQTTDemo) and comparing it step by step with your setup to see what’s missing or not triggered. Speed Stars
Last updated: 2026-04-27

Post by tcarlbom on Read tag values using external program CODESYS Forge talk (Post)
This is my first time posting in this forum and I am new to codesys. I am a fullstack developer and I am trying to figure out how the following. What would be the best approach to create a own/custom tag browser? Either directly in codesys ide or using a separate custom program (perhaps a winforms application). 1.a. Shall I parse the .project xml file to get a list of all tags in the project? 1b. Shall I use python scripting in codesys ide to get a list of tags? Once one have selected some tags. These tags shall be exposed to a python program which will be acting as a edge computer. It’s fine to be able to import a file. 2a. I found a library called codesys plchandler which (as I understand) acts a rest api server. Is this correct? If so, can I query the api from a custom python script, ie can query what tags exist in project and or read tag values? My research so far. From earlier projects I know that using opc ua would be perfect for this but from my opinion it’s bloating the plc since it’s resource intensive. So opc ua is not an option. Codesys automation server is neat. But I don’t want to rely on some cloud services and subscription based pricing. There seem to be several interesting codesys libraries like mqtt, tcp server and NVL sender which would help me expose plc tags. But all have a common problem. One have to manually write what tags which will be used in these function blocks. I want a similar experience like “selecting” tags in the opc ua or the codesys tracing, ie a tag browser.
Last updated: 2024-06-28

Post by fmon on Modbus : dis- / re-connect cable: modbus does not re-start CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED" It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus reconnection. What is different at the first connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-14

Post by fmon on Modbus TCP client reconnection problem CODESYS Forge talk (Post)
Hello, I am using codesys Modbus TCP client (4.4.0.0) to communicate with a python modbus server (package pyModbusTCP). I first start my python server on the distant machine. After a fresh codesys compilation, a plc connection/transfer and a PLC run, the modbus connection is OK. Every time in this context the connection is created correctly. When I shut down the server, the modbus connection falls, that is normal. When I restart the python server, impossible to recreate the modbus connexion. With the client autoreconnection, I see on my server that the client tries to connect but unsuccesfully. I have the following message : DEBUG:pyModbusTCP.server:accept new connection from ClientInfo(address='192.168.1.20', port=33476) DEBUG:pyModbusTCP.server:Exception during request handling: NetworkError('recv return null') I tried to stop the codesys client and to restart it with these commands : Modbus_TCP_Client.xStop := True; // Or False Modbus_TCP_Client.Enable := True; // Or False Modbus_TCP_Server.Enable := True; // Or False I tried to confirm the error manually to force reconnection with: Modbus_TCP_Server_Motors.xConfirmError := TRUE; I tried also this command to STOP/RESET/START client and server (codesys side) but nothing happens : status_client := Modbus_TCP_Client.SetCommunicationState(eRequestedState := DED.DEVICE_TRANSITION_STATE.STOP); // .RESET & .START The answer of this function when executed is "status_client = NOT_SUPPORTED". Is it normal ? It seems that is a socket problem, but I do not understand if it is on the client or server side. I tried a modbus simulator called "ananas.exe" and the result is the same. Impossible to get a modbus client reconnection. What is different at the first client connection and at a reconnection attempt ? Thanks for your help
Last updated: 2025-03-17

Post by laurits on Max lines of code, codesys CNC ? CODESYS Forge talk (Post)
Hi, yes now its working, to get "QUEUE.bFull" to work, I've had to set the "QUEUE.nNumReservedEntries" to 3. (I tried different values here, only effect for larger values i can see is the the queue capacity gets smaller.) I've noticed the movement is slowing down when it reaches the end of the "fill Up", must be because of the "checkVelocity" can only see the current "QUEUE". Any way of solving this ? BUF : ARRAY[0..20000] OF SMC_GEOINFO; xp : ARRAY[1..100000] OF REAL; yp : ARRAY[1..100000] OF REAL; CASE iState OF 000: IF R_TRIG_bStart.Q THEN iState := iState + 1; END_IF bReady := FALSE; //initialize Queue GEO.dT1:=0; GEO.dT2:=1; GEO.dToolRadius := 0; GEO.dVel := 15000; GEO.dVelEnd := 15000; GEO.dAccel := 2000; GEO.dDecel := 2000; GEO.iObjNo := 0; GEO.piDestPos.dX := 0; GEO.piDestPos.dY := 0; QUEUE.bEndOfList := FALSE; QUEUE.nPastMarker := -1; QUEUE.nWritePos := 0; QUEUE.pbyBuffer := ADR(BUF[0]); n := 0; sMC_CheckVelocities(bExecute:= FALSE); SM3_CNC.SMC_SetQueueCapacity(ADR(QUEUE), SIZEOF(BUF)); QUEUE.nNumReservedEntries := 3; 001: FOR i := 1 TO SIZEOF(xp)/SIZEOF(xp[1]) DO xp[i] := UDINT_TO_REAL(i) * 0.01; yp[i] := UDINT_TO_REAL(i) * 0.01; END_FOR iState := iState + 1; 002: WHILE NOT QUEUE.bFull DO // when the Queue is full, wait until it has been processed by the following FBs n := n + 1; GEO.iSourceLine_No := n; GEO.piStartPos := GEO.piDestPos; // copy last destination GEO.iMoveType := LIN; // generate linear movement GEO.iObjNo := GEO.iObjNo + 1; // calculate number GEO.piDestPos.dX := xp[n]; // generate position GEO.piDestPos.dY := yp[n]; SMC_CalcLengthGeo(pg := ADR(GEO)); // calculate length of object with the help of the standard function SMC_AppendObj(poq:=ADR(QUEUE), pgi:=ADR(GEO)); //append object to queue IF n = UDINT_TO_DINT( SIZEOF(xp)/SIZEOF(xp[1])) THEN // all target positions processed QUEUE.bEndOfList := TRUE; iState := iState + 1; EXIT; END_IF END_WHILE sMC_CheckVelocities(bExecute:= TRUE, poqDataIn:= ADR(QUEUE)); bReady := TRUE; // Send message to smc_interpolator to start 003:
Last updated: 2025-06-04

Post by testlogic on Sending Sequential Modbus TCP Packets CODESYS Forge talk (Post)
I have a Modbus TCP slave device where I need to do sequential writes to the same register. The register I'm writing to is kind of like a command line, each packet is a command word encoded in Hexadecimal. I am having difficulty implementing this system in CoDeSys 3.5 SP19. I feel like the structure of the program should be something along the lines of (Pseudocode): ModbusTCPSend(Command Register, Command1) ModbusTCPSend(Command Register, Command2) ModbusTCPSend(Command Register, Command3) I have tried to implement this with a rising edge trigger wMot1OPCode := 16#E1; //Stop Motor & Kill Program xMot1SendOP := TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset wMot1OPCode := 16#9E; //Disable Motor xMot1SendOP :=TRUE; //Send OP on rising edge xMot1SendOP := FALSE; //Reset Where "wMot1OPCode" is the IO map for writing to the command register, and "xMot1SendOP" is the rising edge trigger for that modbus channel. However, this doesn't work. The device never responds to the modbus commands. It seems like the trigger variable is switched too quickly for modbus to send the packet. I know the modbus register is working, because I can set the channel to cyclic and the device will respond. However, I can't use this reliably because I need each command to be sent once, in order. Cyclic keeps re-sending the commands and seems like it could miss a command as well if one was sent in-between cycle time. I have also trying using the Application trigger as described by https://faq.codesys.com/pages/viewpage.action?pageId=24510480, but this is also not working for me. See attached picture for my FBD code. This seems like a simple function, I can't tell what I'm doing wrong here. Thanks for the help.
Last updated: 2024-03-06

Post by kishan on SMC_Interpolator / CNC Abort – ControlAxisByPos Sometimes Remains Busy and Axis Continues Moving CODESYS Forge talk (Post)
Hello, I am working with CODESYS SoftMotion CNC using a preprocessing chain, SMC_Interpolator, and SMC_ControlAxisByPos for controlling the CNC axes. I have noticed an issue when aborting CNC execution. When I execute the Abort command, I abort both the CNC preprocessing blocks and SMC_Interpolator. Normally the CNC process stops correctly. However, occasionally after the abort: SMC_Interpolator has already been aborted. CNC preprocessing has also been aborted/reset. But SMC_ControlAxisByPos.bBusy remains TRUE. The corresponding physical axis can still continue moving for some distance. This does not happen every time. My basic sequence is similar to: G-code / CNC preprocessing ↓ SMC_Interpolator ↓ Transformation ↓ SMC_ControlAxisByPos ↓ SoftMotion Axis When the operator requests CNC Abort, I set the Abort inputs of the interpolator and preprocessing function blocks. My questions are: Does SMC_Interpolator.bAbort only stop/reset the interpolator, or should it also stop the motion currently being executed by SMC_ControlAxisByPos? Can SMC_ControlAxisByPos remain Busy after the interpolator has been aborted? If bAvoidGaps = TRUE, could SMC_ControlAxisByPos still be trying to reach the last fSetPosition using the fGapVelocity / fGapAcceleration / fGapDeceleration settings after the interpolator has stopped? What is the recommended sequence for safely aborting a running CNC program? For example, should the sequence be something like: Stop / Abort Interpolator Disable SMC_ControlAxisByPos Execute MC_Stop for all physical axes Wait until all axes reach standstill Abort/reset preprocessing blocks and CNC queues Reset CNC state Re-enable axis controllers Or is there a recommended CODESYS CNC method for performing a complete CNC Abort? I would especially like to understand why SMC_ControlAxisByPos.bBusy can occasionally remain TRUE and continue moving the axis even though the interpolator and preprocessing blocks have already been aborted. CODESYS SoftMotion CNC is being used with real EtherCAT servo axes. Any explanation about the correct abort/stop sequence would be appreciated.
Last updated: 2 days ago

Post by risele on dynamic modbus devices CODESYS Forge talk (Post)
Have the same issue: I'm making a test setup for modbus devices testing and calibration. One is run for every possible address, and it starts with minimal request: if the device is found, it continue to work with it, otherwise it's set to Disabled temporary. Those state machines are running under FOR cycle, and disabled are just skipped. Every instance have its own timer for not running too frequently and a start delay, so the actual requests are separate in time. I also check not for a single error, but have some timer to allow one-two timeouts. The small program disables and re-enables devices temporary (manually, since i could not iterate over MB devices). VAR Reset:ARRAY[1..GVL_MB.MD_COUNT] OF R_TRIG; i:INT; END_VAR {IF hasconstantvalue(GVL_MB.MD_COUNT, 1, >= )} i:=1; MD_1.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_1.xReset:=Reset[i].Q; {END_IF} {IF hasconstantvalue(GVL_MB.MD_COUNT, 2, >= )} i:=2; MD_2.Enable:=GVL_MB.MDPortsEnable[i]; Reset[i](CLK:=GVL_MB.MDPortsEnable[i]); MD_2.xReset:=Reset[i].Q; {END_IF} There is also program to re-enable devices periodically. METHOD ScanBus VAR_INPUT END_VAR VAR j:INT; (*block auto scanning if calibration is running for any device since it's data-reach process that should not be interrupted with modbus timeouts *) CalibrationBusy:BOOL:=FALSE; END_VAR CalibrationBusy:=FALSE; FOR j:=1 TO GVL_MB.MD_COUNT DO CalibrationBusy:=CalibrationBusy OR MD_Calibrate.AutoTesters[j].xBusy; END_FOR; IF CalibrationBusy THEN RETURN; END_IF tBusScanSchedule(IN:=(NOT tBusScanSchedule.Q), PT:=tBusScanPeriod); IF (NOT tBusScanDelayer.Q) AND (tBusScanSchedule.Q OR (NOT xFirstScanPerforemed)) THEN xBusScanBusy:=TRUE; MissingCounter:=0; xFirstScanPerforemed:=TRUE; FOR j:=1 TO GVL_MB.MD_COUNT DO (* MD_Calibrate is main calibration program. Identifiers - is array of State machines mentioned above Phase_Faulted is a state of Identifiers where I'm sure device is missing on the bus *) IF MD_Calibrate.Identifiers[j].state=eStateMDIdentifier.Phase_Faulted THEN MD_Calibrate.Identifiers[j].Rescan(); MissingCounter:=MissingCounter+1; END_IF END_FOR END_IF tBusScanPauser(IN:=tBusScanDelayer.Q AND (MissingCounter>0),PT:=tBusScanDelay*MissingCounter); xBusScanBusy:=tBusScanPauser.Q; xFirstScanPerforemed:=xFirstScanPerforemed OR tBusScanPauser.ET>=tBusScanPauser.PT; Also the GUI have buttons for each address possible that re-enables the device if required.
Last updated: 2026-02-13

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by clesio on CAA.File.Write – Unexpected characters when writing a CSV file CODESYS Forge talk (Post)
Hello everyone, I am trying to create a routine in CODESYS to export a report to a CSV file using the CAA.File library. The file is created successfully, but I am getting some unexpected/unknown characters in the generated CSV. The problem seems to be related to the SIZEOF() function. I am using it for the szSize parameter of File.Write, as recommended in the CODESYS documentation. However, when I use SIZEOF(), the CSV contains extra characters and parts of previous strings. I also tried using LEN(), but in my application the file is created empty, even though the string and the calculated length appear to be correct. Here is the relevant part of my code: PROGRAM Relatorio VAR // Bool b_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Fecha_Arquivo : BOOL; b_Escreve_dados : BOOL; b_Erro_fb_Escreve : BOOL; //STR s_Nome_Arquivo : STRING; s_Palavra : STRING; s_Palavra_Anterior : STRING; s_Data_Atualizada_Formatada : STRING; s_Dia : STRING; s_Mes : STRING; s_Ano : STRING; s_Hora_Atualizada_Formatada : STRING; s_Hora : STRING; s_Minu : STRING; s_Segu : STRING; //INT i_modo_fb_Cria_Arquivo : INT; i_ErroID_fb_Escreve : INT; //UINT i_Tamanho_Palavra : UINT; // Blocos de Funcao fb_Cria_Arquivo : FILE.Open; fb_Fecha_Arquivo : FILE.Close; fb_Escreve : FILE.Write; // DATA E HORA sc_DataTime : SysTimeRtc.RTS_SYSTIMEDATE; // STRUCT = sc uidResultRtcGet : UDINT; //stGetDate : SysTimeRtc.RTS_SYSTIMEDATE; uidResultConvertToDate : UDINT; uidResult : RTS_IEC_RESULT; END_VAR VAR_INPUT //BOOL b_SET_Executa_fb_Cria_Arquivo : BOOL; b_RES_Executa_fb_Cria_Arquivo : BOOL; b_Executa_fb_Escrita : BOOL; // INT i_Linhas_Cabecalho : INT; i_Linhas_Cabecalho_Anterior : INT; END_VAR // Para Testes s_Nome_Arquivo := 'relatorio/Teste1M.CSV'; i_modo_fb_Cria_Arquivo := 0; // TRATAMENTO DE DATOS DATA e HORA uidResultRtcGet := SysTimeRtcGet(uidResult); uidResultConvertToDate := SysTimeRtcConvertUtcToDate(dwTimestampUtc := uidResultRtcGet, pDate := sc_DataTime); // FORMATA DATA EM UMA STRING s_Dia := UINT_TO_STRING(sc_DataTime.wDay); s_Mes := UINT_TO_STRING(sc_DataTime.wMonth); s_Ano := UINT_TO_STRING(sc_DataTime.wYear); s_Data_Atualizada_Formatada := CONCAT(s_Dia, CONCAT('/', CONCAT(s_Mes, CONCAT('/', s_Ano)))); // FORMATA HORA EM UMA STRING s_Hora := UINT_TO_STRING(sc_DataTime.wHour); s_Minu := UINT_TO_STRING(sc_DataTime.wMinute); s_Segu := UINT_TO_STRING(sc_DataTime.wSecond); s_Hora_Atualizada_Formatada := CONCAT(s_Hora, CONCAT(':', CONCAT(s_Minu, CONCAT(':', s_Segu)))); // ABRE e CRIA ARQUIVO IF (b_SET_Executa_fb_Cria_Arquivo OR b_Executa_fb_Cria_Arquivo) AND NOT(b_RES_Executa_fb_Cria_Arquivo) THEN b_Executa_fb_Cria_Arquivo := TRUE; ELSE b_Executa_fb_Cria_Arquivo := FALSE; END_IF fb_Cria_Arquivo( xExecute := b_Executa_fb_Cria_Arquivo, sFileName := s_Nome_Arquivo, eFileMode := i_modo_fb_Cria_Arquivo, xExclusive := FALSE, ); //i_Tamanho_Palavra := SizeOf(s_Palavra); // ESCREVE NO ARQUIVO fb_Escreve( xExecute := b_Executa_fb_Escrita, hFile := fb_Cria_arquivo.hFile, szSize := SIZEOF(s_Palavra), pBuffer := ADR(s_palavra) ); // FECHA ARQUIVO fb_Fecha_Arquivo( xExecute := b_Executa_fb_Fecha_Arquivo, hFile := fb_Cria_arquivo.hFile ); IF Criacao_Edicao_Arquivos.b_Escreve_Cabecalho THEN CASE i_Linhas_Cabecalho OF 1 : s_palavra := 'ESTERILIZADOR'; 2: s_palavra := 'MAQ4; $R$L'; 3: s_palavra := CONCAT(CONCAT('CLIENTE: ',GVL.sReceitaAtual), '$R$L'); 4: s_palavra := CONCAT(CONCAT('NUMERO LOTE: ',DINT_TO_STRING(GVL.Lote)), '$R$L'); 5: s_palavra := CONCAT(CONCAT('OPERADOR: ', DINT_TO_STRING(GVL.Operador)), '$R$L'); 6: s_palavra := CONCAT(CONCAT('DATA: ', s_Data_Atualizada_Formatada), '$R$L'); 7: s_palavra := CONCAT(CONCAT('HORA: ', s_Hora_Atualizada_Formatada), '$R$L'); 8: s_palavra := '$R$L'; 9: s_palavra := 'PARAMETROS AJUSTADOS $R$L'; 10: s_palavra := CONCAT('TEMPO PRE COND.: ', CONCAT(INT_TO_STRING(GVL.rc_T_PreCondicionamento), ' min $R$L')); 11: s_palavra := CONCAT('PULSOS INERTIZACAO 1: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_1), ' PULSOS $R$L')); 12: s_palavra := CONCAT('PULSOS INERTIZACAO 2: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosInertizacao_2), ' PULSOS $R$L')); 13: s_palavra := CONCAT('PULSOS AERACAO: ', CONCAT(INT_TO_STRING(GVL.rc_PulsosAeracao_2), ' PULSOS $R$L')); 14: s_palavra := CONCAT('PRESSAO DE VACUO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PV1_max), ' bar $R$L')); 15: s_palavra := CONCAT('PRESSAO DE VACUO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PV2), ' bar $R$L')); 16: s_palavra := CONCAT('PRESSAO INERTIZACAO 1: ', CONCAT(REAL_TO_STRING(GVL.rc_PN1), ' bar $R$L')); 17: s_palavra := CONCAT('PRESSAO INERTIZACAO 2: ', CONCAT(REAL_TO_STRING(GVL.rc_PN2), ' bar $R$L')); 18: s_palavra := CONCAT('PRESSAO AERACAO: ', CONCAT(REAL_TO_STRING(GVL.rc_PAR), ' bar $R$L')); 19: s_palavra := CONCAT('PRESSAO ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO), ' bar $R$L')); 20: s_palavra := CONCAT('PRESSAO Compl.: ', CONCAT(REAL_TO_STRING(GVL.rc_PressaoETO_2), ' bar $R$L')); 21: s_palavra := CONCAT('MASSA ETO: ', CONCAT(REAL_TO_STRING(GVL.rc_QuantidadeETO), ' Kg $R$L')); 22: s_palavra := CONCAT('TEMPO PRE COND. Vacuo/Vapor: ', CONCAT(INT_TO_STRING(GVL.rc_T_Vapor_1), ' min $R$L')); 23: s_palavra := CONCAT('SET-POINT: ', CONCAT(REAL_TO_STRING(GVL.ihm_SPTemperatura), ' °C $R$L')); 24: s_palavra := CONCAT('TEMPO ESTERILIZACAO: ', CONCAT(INT_TO_STRING(GVL.rc_TempoEsterilizacao), ' min $R$L')); 25: s_palavra := CONCAT('TEMPO PARADA: ', CONCAT(INT_TO_STRING(GVL.rc_T_PressaoParada), ' min $R$L')); 26: s_palavra := CONCAT('UMIDADE: ', CONCAT(REAL_TO_STRING(GVL.rc_UmidadeRelativa), ' % $R$L')); 27: s_palavra := '$R$L'; END_CASE END_IF Note: The code I am attaching does not include the execution/sequence management of the function blocks. I have omitted this part to keep the example focused on the CSV writing routine. The function blocks are triggered and managed by a separate state machine. I am not sure what the correct approach is in this case, especially since the official documentation recommends using SIZEOF() for szSize. I will attach my code and a screenshot of the generated CSV showing the issue. Has anyone experienced something similar or could suggest the correct way to write a changing STRING to a CSV file using CAA.File.Write?
Last updated: 2026-09-08

Post by paulg on RasPi CAA Serial example - unexpected behavior during debug CODESYS Forge talk (Post)
I've trimmed down the CAA Serial Codesys example to only listen on one port but, when stepping through the Case structure in debug mode, it jumps out of the structure during a specific point in every scan (I'll point it out below after describing the setup and listing the code). I'm using a Pi 4 Model B, and I have an Arduino Nano Every plugged in via USB which is streaming the following serial message at 1 Hz: Time since opening connection: 1 s Time since opening connection: 2 s ...and so on. The Pi shows the Nano at /dev/ttyACM0 so I edited CODESYSControl_User.cfg to read: Linux.Devicefile=/dev/ttyACM The code in my PLC_PRG is (ignore some of the comments, I hadn't deleted them out from the original example): PROGRAM PLC_PRG VAR xStartTest : BOOL:= TRUE; iState : INT; xTestDone : BOOL;(* True, when the test was done succesfully *) (* Settings to communicate with the COM Port *) aCom1Params : ARRAY [1..7] OF COM.PARAMETER; como1 : COM.Open; comc1 : COM.Close; comw1 : COM.Write; comr1 : COM.Read; //sWrite : STRING := 'Test String!'; sRead : STRING(25); szRead : CAA.SIZE; xCom1OpenError : BOOL; xCom1CloseError : BOOL; xCom1WriteError : BOOL; xCom1ReadError : BOOL; END_VAR //This example shows the communication of two COM Ports with each other. //The first one writes a string of characters, which is read by the second one. //After successful execution, the two COM Ports are closed and the test is done. IF xStartTest THEN CASE iState OF 0: //The parameters are set for the COM Port aCom1Params[1].udiParameterId := COM.CAA_Parameter_Constants.udiPort; aCom1Params[1].udiValue := 1; // the correct Port should be adapted aCom1Params[2].udiParameterId := COM.CAA_Parameter_Constants.udiBaudrate; aCom1Params[2].udiValue := 115200; aCom1Params[3].udiParameterId := COM.CAA_Parameter_Constants.udiParity; aCom1Params[3].udiValue := INT_TO_UDINT(COM.PARITY.NONE); aCom1Params[4].udiParameterId := COM.CAA_Parameter_Constants.udiStopBits; aCom1Params[4].udiValue := INT_TO_UDINT(COM.STOPBIT.ONESTOPBIT); aCom1Params[5].udiParameterId := COM.CAA_Parameter_Constants.udiTimeout; aCom1Params[5].udiValue := 0; aCom1Params[6].udiParameterId := COM.CAA_Parameter_Constants.udiByteSize; aCom1Params[6].udiValue := 8; aCom1Params[7].udiParameterId := COM.CAA_Parameter_Constants.udiBinary; aCom1Params[7].udiValue := 0; //The first Port is opened with the given parameters como1(xExecute := TRUE, usiListLength:=SIZEOF(aCom1Params)/SIZEOF(COM.PARAMETER),pParameterList:= ADR(aCom1Params)); IF como1.xError THEN xCom1OpenError := TRUE; iState := 1000; END_IF //After a successful opening, the next state is reached IF como1.xDone THEN iState := 15; END_IF 15: // the reading process is started comr1(xExecute := TRUE,hCom:= como1.hCom, pBuffer:= ADR(sRead), szBuffer:= SIZEOF(sRead)); IF comr1.xError THEN xCom1ReadError := TRUE; END_IF //After completion the size of the written bytes are saved IF comr1.xDone OR comr1.xError THEN szRead := comr1.szSize; iState := 20; END_IF 20: // If everything was successful the ports are closed and the handles are released comc1(xExecute := TRUE,hCom:= como1.hCom); IF comc1.xError THEN xCom1CloseError := TRUE; END_IF IF comc1.xDone OR comc1.xError THEN iState := 25; END_IF 25: // The first port is closed and the used handle released xTestDone := TRUE; xStartTest := FALSE; iState := 0; como1(xExecute := FALSE); comw1(xExecute := FALSE); comc1(xExecute := FALSE); ELSE iState := 0; END_CASE END_IF I realize as I write this that the .udiPort should be 0 and not 1, but that shouldn't be causing the issue I'm seeing. I'm forcing xStartTest:=TRUE every scan so that I can step into each line and observe what's happening. What I see is that the port parameters are set and the port is opened with no errors, but the code jumps out of the case structure to the last line every time it reaches (and I step into) the iState:=15 line (at the end of the iState:=0 block). So every scan cycle it goes through the block for iState=0 and jumps out at the same spot. I'm a little new to PLC programming so I may be misunderstanding the flow, but shouldn't this case structure keep moving down in the same scan? If it only handles one case per scan, why doesn't the value of iState persist? Thanks! Update: I restarted the Codesys control today and I was then able to see an error for como1.eError of "WRONG_PARAMETER". I tried doing some digging and another post made me think I should add another line to CODESYSControl_User.cfg, so I now have: [SysCom] Linux.Devicefile=/dev/ttyACM portnum := COM.SysCom.SYS_COMPORT1 So now when I set .udiPort to 1, I get "NO_ERROR" but I also don't read anything from the port (i.e. szRead = 0 always). If I try setting the port to 0 (which I'm confused about, because I added a COMPORT1 line but the device shows on the Pi as ACM0), I get the "WRONG_PARAMETER" error again. Is there an easier way to troubleshoot the Pi and view what ports the Codesys runtime is actually able to see while the Pi is running?
Last updated: 2024-06-06

Post by dwpessoa on CNC Jumps G20 - SMC_NCInterpreter and long time to process CODESYS Forge talk (Post)
I am studying and developing a Softmotion+CNC system for a machine that executes multiple pieces. The G code program is written by the machine operator and each cycle execute 1 piece. The programs are large, exceeding 1000 lines and using up to 8 axes (X, Y, Z, A, B, C, P and Q). The machine needs to run cyclically, executing N pieces (selected by the Operator)... so I tested it using Looping and counters (G36 G37 and G20) and it worked, but it takes a long time to process, and the more pieces I need, the longer the processing time and this is totally impracticable. I found this solution which was very good, and for a few cycles it works well, but for 99999 pieces of a program with 1000 lines, it doesn't work very well... Another solution I tested is to maintain the interpolator with an automatic restart, that is, I load the program without looping (without G20) and give it another start as soon as it finishes. This partially resolved it, but there is still a delay in processing SMC_NCInterpreter in each restart :(. Another solution I thought of is to manually create the SMC_GEOINFO structure and then reuse it, avoinding the Interpreter, but reading the documentation and checking the structure filled by standard blocks, I noticed that there doesn't seem to be a "JUMP" function in the structure! In other words, the SMC_NCInterpreter actually keeps copying and copying the program section for each jump (G20)... If I repeat a 10-line program 1000 times, I will have a structure with more than 10000 lines... possibly this is the cause of take so long to process. Has anyone ever had a problem like this? I believe the same thing happens with typical applications with manipulator robots using Codesys in continuous cycles, and I would like to know if there is any solution, or even if I am misinterpreting the G20 question in SMC_GEOINFO. Thanks!
Last updated: 2023-09-20

Post by mgabryel on Problems with CAN 2.0 comunication on Wago PLC (Codesys 3.5) CODESYS Forge talk (Post)
Hello, I am trying to program CAN Bus comunication on WAGO PLC (more precisely on WAGO Touch Monitor model TP600). I am using for this purpose library "WagoAppCanLayer2" from Wago company. My IDE for programming this device is CODESYS V3.5 SP19 Patch 2 + (64-bit). My program is written in Structured text using function blocks from previously mentioned library. Here is code of this program: 1) Variables declarations: PROGRAM PLC_PRG VAR oOpenInterface : WagoAppCanLayer2.FbCanL2Open :=( udiBaudrate := 125000 ); xInterfaceIsOpen : BOOL; sInterfaceInfo : STRING; oReceive : WagoAppCanLayer2.FbCanRx29BitFrame :=( xBufferMode := FALSE, wCanId := 16#181 ); xRecv : BOOL; sReceiveInfo : STRING; oSend : WagoAppCanLayer2.FbCanTx29BitFrame :=( dwCanId := 16#100, //was 16#201 xRtrFrame := FALSE ); xSend : BOOL; sSendInfo : STRING; oCanDiag : WagoAppCanLayer2.FbCanErrorInfo; xRst : BOOL; aSendData : ARRAY [1..8] OF BYTE; bSendLen : BYTE; TON_0 : TON; TON_1 : TON; END_VAR 2) Program body: oOpenInterface( xEnable := NOT xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE ); sInterfaceInfo := oOpenInterface.oStatus.GetDescription(); xInterfaceIsOpen S= oOpenInterface.xValid AND NOT oOpenInterface.xError; oReceive( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xRxTrigger := xRecv ); sReceiveInfo := oReceive.oStatus.GetDescription(); IF NOT xRecv THEN IF oReceive.bRxNBytes > 0 THEN oReceive.aRxBuffer[1]; oReceive.aRxBuffer[2]; oReceive.aRxBuffer[3]; oReceive.aRxBuffer[4]; oReceive.aRxBuffer[5]; oReceive.aRxBuffer[6]; oReceive.aRxBuffer[7]; oReceive.aRxBuffer[8]; END_IF xRecv := TRUE; END_IF aSendData[1] := 224; aSendData[2] := 13; aSendData[3] := 14; aSendData[4] := 15; aSendData[5] := 222; aSendData[6] := 13; aSendData[7] := 14; aSendData[8] := 15; bSendLen := 8; TON_0(IN:= NOT TON_1.Q, PT:= T#2S , Q=>xSend, ET=> ); TON_1(IN:= TON_0.Q, PT:= T#2S , Q=>, ET=> ); oSend( xEnable := xInterfaceIsOpen, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, aTxBuffer := aSendData, bTxNBytes := bSendLen, xTxTrigger := xSend ); sSendInfo := oSend.oStatus.GetDescription(); oCanDiag( xEnable := TRUE, I_Port := IoConfig_Globals.WAGO_CAN_LAYER2_DEVICE, xTriggerResetCounter := xRst, xValid=> , xError=> , oStatus=> , wBusState=> , wBusDiag=> , uiRxOverflowsL2=> , uiTxOverflowsL2=> , uiRxOverflows=> , uiMsgTimeouts=> , uiBusOffs=> , uiBusWarnings=> ); Program first opens comunication on CAN 2 device and then periodically try send one CAN data frame. After starting program CAN 2 interface is properly open. The xSend variable is toggling with period 2s. When program sends data an "Tx overflow" error appears. When I am watching CAN_H line on DSub 9 socket i am not able to see proper CAN frames - see screenshot attached to this message. Could somebody help me determine what is wrong with this program. Best regards
Last updated: 2024-08-02

Post by patrik on Wish: CODESYSControl.cfg - again CODESYS Forge talk (Post)
Really good post. I hope that it gets seen by CoDeSys staff. I often find the documentation lacking when it comes to using CoDeSys in more complex ways. If using standard "basic PLC functionality", then it's fine and functions are documented in a sufficient way. Once you go outside of that bubble then I find the documentation not enough. CODESYSControl.cfg is a good example of this. And why isn't more of this integrated in the IDE. like changing port of the webserver. Why is it hidden in this file and not accessible through the IDE. It feels like a layer of complexity purposely left in so you don't change it if you don't know what you are doing. Like the argument is if you have the know-how to find the file you have the know-how to edit it. I find the documentation lacking when it comes to more complex libraries too. Like the element collections library. there is parameters I still don't quite know what they do. I can't find any documentation about them. There is an example project to download from CoDeSys so you can see how you are supposed to set your factories up. I leave some parameters like it is in the example. Should I? I don't know. Does it work. Yes. But I could perhaps create memory leaks if I get something wrong and I don't see that until way later. In the create method of your element factory you have a function called __vfinit and you just have to accept that it works. Why can't I get insight in what it does through documentation? Don't CoDeSys want us to know how these work so we can't use them to accidentally break something? I find the error logging lacking too. I've had the CoDeSys service crash but it doesn't say why. I've seen windows noticing the crash but no error code was sent or error message. Also in my current issue where the application fails to start after power outage. I can see in the log that it fails to load retain in the application as one log entry and application failing to start as another. But why? Why does loading the retain fail? give me more information! Is it just a skill issue with me? I don't know. If it is then I'd still want CoDeSys to step up their game when it comes to documentation. I'm sorry if a lot of frustration comes though in this post. I really like the product and what I can do with it compared to other PLC brands.
Last updated: 2024-11-21

Post by rkohser on Scripted Git clone / checkout being blocked by "Project Environment" popup CODESYS Forge talk (Post)
Hi, I am trying to build a CI/CD pipeline around our codesys projects. The only entry point if the git url and branch, as we do not put our project file under source control, so we needed to find a way to git clone from the python scripting engine. This is currently how we do this : system.commands["Git", "Clone"].execute( "ProjectLocation=" + project_dir, "ProjectName=" + project_file_name, "RemoteUrl=" + project_git_remote_url, "GitProjectStoragePath=" + project_git_local_dir, ) system.commands["Git", "Checkout", "Branch"].execute( "PrimaryProjectHandle=0", "BranchName=origin/" + project_git_branch ) This works fine, except that, depending on the environment and the project, the "Project Environment" popup gets displayed to suggest for some updates, and waits for a user interaction, even with the "--noUI" flag injected as parameter. I investigated the VersionUpdateFlags, but the problem is that the git clone is an atomic operation that clones and directly opens the generated project without the possibility to inject any updateFlags argument (only used in the ScripProjects.open() function. I also tried to simulate some keyboard events acknowledge the window from script but I did not find the right location for the SendKeys statement, I think before the git clone call is too early and after is too late. So I am wondering if there would be some other way to do that. Is there some more proper scripting api for the git add on ? Is there a global configuration of the VersionUpdateFlags that would allow the popup to be disabled outside from any project context ? Is there some way to automatically acknowledge this kind of messages in a "--noUI" mode ? What do you suggest ? Thanks for your help, Roland Edit : I managed to solve my problem by following these steps in my pipeline : - create a template of a project and opt file preconfigured not to open the popup - open this project - initialize an empty git repo - add the remote, fetch and checkout the needed branch -> no popup is displayed, hourra Edit2 : The initial question was raised on a CODESYS V3.5 SP18 Patch 2 profile. Since CODESYS 3.5.19.30 a scripting API is available for Codesys Git that allows cloning a project with the support of VersionUpdateFlags https://content.helpme-codesys.com/en/CODESYS%20Git/_git_using_scripting.html
Last updated: 2024-01-19

Post by greenwood on CODESYS Control Raspberry Pi mit Servotreiber T6 von StepperOnline CODESYS Forge talk (Post)
Hallo, ich versuche, eine Modbus-RTU-Kommunikation zwischen meinem Raspberry Pi mit CODESYS Control für Raspberry Pi 64 SL und einem Servotreiber von StepperOnline, Typ T6, herzustellen. Die Verbindung ist wie folgt: RJ45-Stecker am Servotreiber -> Kabel mit RJ45 an einem Ende und USB-A-Stecker am anderen Ende -> Seriell-zu-USB-Konverter -> Raspberry Pi. Der Seriell-zu-USB-Konverter und die Kabel habe ich zusammen mit dem Motor und Treiber von StepperOnline gekauft und sie sind dafür gedacht, den Servotreiber mit einem Computer zu verbinden, auf dem deren Setup-Software läuft. dmesg | grep tty auf dem Pi sagt mir, dass der USB-zu-Seriell-Konverter auf ttyusb0 ist. Ich weiß nicht, wie man das in einen COM-Port übersetzt, ich habe COM 1 genommen. Ich habe ein Projekt in Codesys erstellt und ein Modbus_COM-Gerät hinzugefügt, einen Modbus_Master_COM_Port und einen Modbus_Slave_COM_Port angehängt. Auf der Registerkarte "Allgemein" des Modbus_COM habe ich die folgenden Werte eingestellt: Slave address 1 Baud rate 9600 Parity None Data bits 8 Stop bits 2 Ich habe den Servotreiber auf die gleichen Werte eingestellt. (Ich habe auch andere Werte getestet, aber mit dem gleichen Ergebnis). Auf der Registerkarte "Modbus Slave Channel" des Modbus_Slave_COM_Port habe ich einen Kanal hinzugefügt und die folgenden Werte eingetragen: Access type Read Holding Registers (Function Code 3) Read Register offset 0x0000 Length 1 Ich habe noch keinen Code geschrieben, weil ich noch nicht herausgefunden habe, wie man die Kommunikation programmiert. Wenn ich das Projekt zum Raspberry Pi herunterlade scheint der Modbus_Master_COM_Port zu laufen (grünes Symbol), aber der Modbus_Slave_COM_Port nicht (rotes Dreiecksymbol). Wenn ich einen anderen COM-Port eintrage, haben sowohl der Master als auch der Slave das rote Dreiecksymbol. Ich habe dies auch mit meinem Windows-PC unter Verwendung von Codesys Control Win 64 versucht und die gleichen Ergebnisse bekommen. Ich wäre dankbar für jede Hilfe oder Tipps, wie ich den Grund dafür herausfinden kann, warum der Servotreiberreiber nicht reagiert.
Last updated: 2024-05-31

<< < 1 .. 33 34 35 36 > >> (Page 35 of 36)

Showing results of 881

Sort by relevance or date