Array of Bits
CODESYS Forge
talk
(Thread)
Array of Bits
Last updated: 2023-07-11
Out of persistent memory
CODESYS Forge
talk
(Thread)
Out of persistent memory
Last updated: 2021-03-22
Change Velcoity of MC_MoveAbsolute
CODESYS Forge
talk
(Thread)
Change Velcoity of MC_MoveAbsolute
Last updated: 2018-06-28
Array of FB initialization
CODESYS Forge
talk
(Thread)
Array of FB initialization
Last updated: 2018-02-15
Two version of codesys
CODESYS Forge
talk
(Thread)
Two version of codesys
Last updated: 2019-11-13
Testing of Codesys program
CODESYS Forge
talk
(Thread)
Testing of Codesys program
Last updated: 2023-12-08
Inheritance of axis
CODESYS Forge
talk
(Thread)
Inheritance of axis
Last updated: 2024-01-12
History of Alarms
CODESYS Forge
talk
(Thread)
History of Alarms
Last updated: 2026-01-07
History of Alarms
CODESYS Forge
talk
(Thread)
History of Alarms
Last updated: 2026-01-05
Post by dkugler on Webvisu client connection monitoring
CODESYS Forge
talk
(Post)
is your pointer set to the correct visu client? set a breakpoint in your client iteration and step through the active visu clients like programming system, targetvisu, webvisu,... and check the last usage value of each client
Last updated: 2024-08-30
Post by timvh on Help with DynamicTextGetTextW
CODESYS Forge
talk
(Post)
First of all you need to enable "Use unicodestrings" in the Visualization Manager. This function returns a pointer to a WSTRING (not STRING). To get this wstring value, do something like this: VAR myWstringVariable : WSTRING(255); END_VAR myWstringVariable := myResult^; // this is dereferencing the pointer to the WSTRING.
Last updated: 2024-09-03
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Easier that I thought, by ALIAS TYPE log_item_val_type : ( BOOL_ := 0, INT_, REAL_, STRING_ ); END_TYPE TYPE LOG_DATA_BASE STRUCT val_type : log_item_val_type; (* value, name etc *) ENDSTRUCT ENDTYPE TYPE LOG_DATA_BOOL : LOG_DATA_BASE := (val_type := log_item_val_type.BOOL_); END_TYPE TYPE LOG_DATA_INT : LOG_DATA_BASE := (val_type := log_item_val_type.INT_); END_TYPE TYPE LOG_DATA_REAL : LOG_DATA_BASE := (val_type := log_item_val_type.REAL_); END_TYPE TYPE LOG_DATA_STRING : LOG_DATA_BASE := (val_type := log_item_val_type.STRING_); END_TYPE
Last updated: 2025-03-05
Post by dim54 on MBChannel
CODESYS Forge
talk
(Post)
Hello! I am interested in the Modbus Slave channel parameter uiReadLength to use in the ST-program (see picture). How to read the value of uiReadLength in a ST-program? Only Edwin the Great and Terrible can answer this question.
Last updated: 2024-01-22
Post by tomas111 on Text List Fallback Value
CODESYS Forge
talk
(Post)
What version of codesys? Need to avoid in any specific element? Try writing %s in the text, it should work. Or better yet, attach a screenshot.
Last updated: 2024-04-17
Post by sigurdrb on OPC server in "Communication manager"
CODESYS Forge
talk
(Post)
Hi! I was thinking of switching the OPC server config from "Symbol Configuration" to the "Communication manager" in the device tree. I Have a lot of arrays of structs that I have previously declared in the "Persistent Variable" object in the device tree. It seems as it is not supported to directly expose persistant variables to the OPC server like the "older" way of doing it in the symbol config. Is this correct? Do you recommend to just do it the old fashioned way, or should I edit the structure of the global variable list / persistant data / OPC server and set up the OPC server from the "Communication manager" object?
Last updated: 2025-01-20
Post by davidbo on RETAIN PERSISTENT only stored at gracefully shutdown?
CODESYS Forge
talk
(Post)
I have {attribute 'checksumnoinit_override' := '2629838988'} {attribute 'init_related_code' := '5c6efcf8-e0f4-4166-a9fa-17eadd8908df'} VAR_GLOBAL RETAIN PERSISTENT {attribute 'order_in_persistent_editor' := '0'} segmentValue: ARRAY[0..49] OF REAL; {attribute 'order_in_persistent_editor' := '1'} segmentTime: ARRAY[0..49] OF REAL; // Generated instance path of persistent variable PRG.test: INT; // Generated instance path of persistent variable PRG.nw_storage: SysSocket_Implementation.SysSocket_Interfaces.SOCK_ADAPTER_INFORMATION2; END_VAR When I have changed PRG.nw_storage it will not be stored at a power off, but if I do a: sudo systemctl restart codesycontrol and then a power off it will be stored. Is there a way to store persistent variables without a restart of codesyscontrol? Can anyone explain how and when CODESYS store persistent variables?
Last updated: 2025-11-17
Post by simotion on Axis_Ref_SM3.perfTimers
CODESYS Forge
talk
(Post)
Yes but what exactly does each of them stand for?
Last updated: 2023-11-24
Post by vsgn on Passing properties as VAR_IN_OUT variables.
CODESYS Forge
talk
(Post)
Hi, in my experience, the best options for such a case could be: 1. Pass a FunctionBlock via VAR_IN_OUT, containing all variables, mehods and properties needed for the logic of this graphic element (be aware of implementing correcly both get and set accessor for properties) 2. Pass an Interface via VAR_INPUT, of which you can use obviously only Properties and Methods. This is much more elegant for me. Here, you can just pass directly the instance of a FunctionBlock implementing such Interface as input. Hope you'll find this suggestions useful.
Last updated: 2025-05-13
Post by jackbrady on Function Blocks and arrays of function blocks
CODESYS Forge
talk
(Post)
Thanks for the reply. Much appreciated.
Last updated: 2024-02-15
Automation Server π¬π§
CODESYS Forge
talk
(Discussion)
The Industry 4.0 administration platform for users and operators of CODESYS compatible controllers
Last updated: 2026-06-16
Post by umdee on Error when monitoring LAD programs
CODESYS Forge
talk
(Post)
I get the following error when monitoring my program (see attached screenshots): "Unhandled exception has occured in your application. If you click Continue, the application will ignore this error and attempt to continue. If you click Quit, the application will close immediately. Value cannot be null. Parameter name: source. And the details say: See the end of this message for details on invoking just-in-time (JIT) debugging instead of this dialog box. ** Exception Text ** System.ArgumentNullException: Value cannot be null. Parameter name: source at System.Linq.Enumerable.Any[TSource] (IEnumerable1 source, Func2 predicate) at _3S.CoDeSys.NWLEditor.NWLTextCell.OnPaintCellLayer(PaintEventArgs e) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.PaintCellCellLayer(PaintEventArgs e, GfxCell cell) at _3S.CoDeSys.Controls.Controls.GfxEdControl.OnPaint(PaintEventArgs e) at System.Windows.Forms.Control.PaintWithErrorHandling(PaintEventArgs e, Int16 layer) at System.Windows.Forms.Control.WmPaint(Message& m) at System.Windows.Forms.Control.WndProc(Message& m) at System.Windows.Forms.UserControl.WndProc(Message& m) at _3S.CoDeSys.Controls.Controls.GfxEdControl.WndProc(Message& m) at System.Windows.Forms.NativeWindow.Callback(IntPtr hWnd, Int32 msg, IntPtr wparam, IntPtr lparam) ** Loaded Assemblies ** (3000 lines of assemblies) ** JIT Debugging ** To enable just-in-time (JIT) debugging, the .config file for this application or computer (machine.config) must have the jitDebugging value set in the system.windows.forms section. The application must also be compiled with debugging enabled. For example: <configuration> <system.windows.forms jitdebugging="true"> </system.windows.forms></configuration> When JIT debugging is enabled, any unhandled exception will be sent to the JIT debugger registered on the computer rather than be handled by this dialog box The windows show red X's where the networks should be. Any advice on how to fix this? Additional Information PLC used: Wago 750-8212, Firmware FW26 Startup profile: CODESYS V3.5 SP19 Patch 5 OS version: Microsoft Windows NT 10.0.22631.0 .NET version: 4.0.30319.42000 Full Version info attached as .txt
Last updated: 2024-03-17
Post by vladimirsmall on Send data to USB
CODESYS Forge
talk
(Post)
Hello/ Need send some file ( for example Array of string) to USB. Which library need used for this. Thank you
Last updated: 2024-07-20
Post by pernockham on Inheritence of struct,
CODESYS Forge
talk
(Post)
Apparently my construction will not work as any of the sub-types are not be able to accept any (further) value-initiation. Ie: string_item : log_data_base := (string_value := 'test', val_type := STRING_); is not eq to (the string_value will not be assigned): string_item_2 : log_data_string := (string_value := 'test'); Because effectively for the compiler this is eq. to a "double" assignment where the compiler sees only the first assignment (my guess). string_item_2 : log_data_base := (val_type := STRING_) := (string_value := 'test'); Im not sure this should be treated as a bug, but it would surely be nice to be able to use this construction (compiler is 3.5.20.40). Anyone see any other alternative for solution (other than 4 complete STRUCTS with all fields individually defined)?
Last updated: 2025-03-07
To search for an exact phrase, put it in quotes. Example: "getting started docs"
To exclude a word or phrase, put a dash in front of it. Example: docs -help
To search on specific fields, use these field names instead of a general text search. You can group with AND or OR.